Dell™ 2161DS Console Switch Hardware and OSCAR® User's Guide Model: 2161DS Console Switch www.dell.com | support.dell.com - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 2
and tells you how to avoid the problem. CAUTION: A CAUTION indicates a potential Dell, PowerEdge, Powervault, PowerApp, and the DELL logo are trademarks of Dell products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own. Model: 2161DS Console Switch July - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 3
1 Product Overview Features and Benefits 9 SIP Intelligent Cabling 9 Interoperability with Avocent® AVRIQ Intelligent Cabling 9 Access Via Network Connection 10 Point and Click Control With the Remote Console Switch Software . . . 10 Interoperability with Avocent A1000R/A2000R Switches 11 - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 4
Set/Change Passwords 60 Restore Factory Defaults 61 Reset Appliance 61 Display Diagnostic Report 61 Exit 61 5 Appendices Appendix A: Flash Upgrades 63 Upgrading the Dell™ 2161DS Console Switch 63 Upgrading the SIP 64 Upgrading Cascaded Dell 8-port and 16-port Console Switch 67 4 Contents - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 5
Only). . . . 73 Total Satisfaction Return Policy (U.S. Only 76 Limited Warranty Terms for Dell-Branded Hardware Products (Canada Only) 76 Total Satisfaction Return Policy (Canada Only 79 Dell Software and Peripherals (Canada Only 80 1-Year End-User Manufacturer Guarantee (Latin America and the - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 6
Status Dialog Box 46 Disconnect Dialog Box 46 Preempt Dialog box 48 Diagnostics Dialog Box 49 Suspect SIPs Dialog Box 51 Version Dialog Box 52 Digital Version Dialog Box 52 SIP Selection Dialog Box 53 SIP Version Dialog Box 54 Main Dialog Box 55 Scan Dialog Box 56 Command Dialog Box - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 7
SIP Load Dialog Box 69 OSCAR Status Symbols 34 Keyboard and Mouse Navigation 36 OSCAR Status Flags 43 LAN Connection Test Icons 51 Diagnostic Test Details 51 Technical Specifications 73 Contents 7 - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 8
8 Contents - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 9
1 Product Overview Features and Benefits The Dell™ 2161DS Digital Console Switch combines analog and digital technology to provide flexible, centralized, control of data center servers. This solution delivers a significant reduction in cable volume, as well as secure digital access, and flexible - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 10
www.dell.com | support.dell.com Access Via Network Connection No special software or drivers are required on the attached computers. Users access the 2161DS Console Switch unit and all attached systems via Ethernet from a PC running the Remote Console Switch Software application. This software - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 11
disconnect all power supply cables before servicing the system. This document pertains only to the Dell 2161DS Console Switch. You should also read and follow the additional safety instructions contained elsewhere: • The 2161 DS Console Switch Installation Guide included with your rack solution that - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 12
instructions. • Keep your system away from radiators and heat sources. Also, do not block cooling vents. • Do not spill food or liquids on your system components, and never operate the product in a wet environment. If the system gets wet, see the appropriate section in your troubleshooting guide - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 13
service provider or local power company. NOTICE: To help avoid damaging your system, be sure the voltage selection switch total ampere rating of all products plugged into the power strip does service technicians. If a nonDell rack is utilized, be sure that the rack meets the specifications of a Dell - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 14
www.dell.com | support.dell.com 14 Product Overview - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 15
Console Switch: • 2161DS Console Switch unit • Local country power cord • Rack mounting brackets • Serial cable • 2161DS Console Switch Hardware and OSCAR User's Guide on CD • 2161DS Console Switch Remote Console Switch Software User's Guide on CD • 2161DS Console Switch Installation Instructions - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 16
uses IP addresses to uniquely identify the 2161DS Console Switch units, Avocent A1000R/A2000R units and the computers running Remote Console Switch Software. The 2161DS Console Switch supports BootP (Bootstrap Protocol) and static IP addressing. Dell recommends that IP addresses be reserved for each - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 17
six rack nut/holders to the mounting rail of the rack so that the nut is positioned on the inside of the rack. 4 Mount the switch assembly to the rack by matching the holes in the "short side" of each bracket to an appropriate set of matching holes on your equipment - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 18
| support.dell.com Figure 2-4. IU Installation Installing the 2161DS Console Switch Unit The diagram below illustrates one possible configuration for your 2161DS Console Switch appliance. Follow the detailed set of procedures following Figure 2-5 to successfully install your 2161DS Console Switch - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 19
is easily accessible at all times problems. NOTE: The maximum supported cable length from switch to server is 10 meters. To install the 2161DS Console Switch hardware: 1 Remove the 2161DS Console Switch unit from the packing material. 2 Connect a terminal or PC running terminal emulation software - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 20
dell.com | support.dell.com 3 Plug the supplied power cord into the back of the 2161DS Console Switch unit and then into an appropriate power source. 4 When the power is switched , press the key to access the main menu. To configure the 2161DS Console Switch hardware: 1 You will see the - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 21
Remote Console Switch Software User's Guide. Mouse Acceleration To adjust the mouse acceleration: NOTE: Dell highly recommends that all Microsoft® Windows® systems attached to the 2161DS Console Switch account that will be accessing the NT system through the 2161DS Console Switch. Installation 21 - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 22
. Always disconnect the power cord from the wall outlet.Power down the 2161DS Console Switch unit before servicing. Always disconnect the power cord from the wall outlet. NOTE: In addition to Dell SIPs, the 2161DS Console Switch may also be connected to servers using Avocent AVRIQ, including Sun and - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 23
. 4 Connect the other end of the CAT 5 cable to the first of the SIPs. 5 Repeat steps 3-4 for all servers you wish to attach. Figure 2-7. 2161DS Console Switch Configuration With a PEM Installation 23 - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 24
www.dell.com | support.dell.com Figure 2-8. PEM Rack Installation Adding a Cascade Switch (Optional) You can add your cascade switches in the 2161DS Console Switch system. Each ARI port will then accommodate up to 16 servers, increasing the total number of servers you can add to 256. To add a - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 25
Connecting to the Network To connect the network and power up your 2161DS Console Switch: 1 Connect your network cable to the LAN port on the rear of the 2161DS Console Switch to your network. 2 Power up all attached systems. To connect the analog port monitor and PS/2 keyboard and mouse: Attach - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 26
www.dell.com | support.dell.com To install a SIP in a 1U or 2U cable management arm: Route the SIP through the cable management arm. The following series of figures demonstrate - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 27
system. Proceed to "Analog Port Operation" in this user's guide for detailed instructions on OSCAR setup and configuration. Once your servers are named, you will want to go to a digital station and configure the Remote Console Switch Software. For more information, see "Installation" for an overview - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 28
www.dell.com | support.dell.com 28 Installation - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 29
Controlling Your System at the Analog Port The Dell™ 2161DS Console Switch includes an analog port on the back of the unit that allows you to connect a monitor, a PS/2 keyboard, and a mouse for direct analog access. The 2161DS Console Switch uses the On-Screen Configuration and Activity Reporting - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 30
www.dell.com | support.dell.com Figure 3-15. Example of Configured Main Dialog Box NOTE: You can also press the key twice within one second to launch OSCAR. You can use this key sequence in any place you see throughout this User's Guide. NOTE: To clear an offline Server - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 31
Selecting Servers Use the Main dialog box to select servers. When you select a server, the 2161DS Console Switch reconfigures the keyboard and mouse to the proper settings for that server. To select servers: Double-click the server name, EID or port number. -orIf - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 32
www.dell.com | support.dell.com To soft switch to a server: 1 To select a server, press - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 33
OSCAR. Select the Names button when initially setting up your 2161DS Console Switch system to identify servers by unique names. Select the other setup features to manage routine tasks for your servers from the OSCAR menu. To access the Setup menu: 1 Press to launch OSCAR. The Main - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 34
. For information, see Figure 3-18. To access the Names dialog box: 1 Press . The Main dialog box will appear. 2 Click Setup - Names. The Names dialog box appears. Figure 3-17. Names Dialog Box NOTE: If new SIPs are discovered by the 2161DS Console Switch, the on-screen list will be - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 35
To assign names to servers: 1 In the Names dialog box, select the name or port number you wish to change and click Modify. The Name Modify dialog box appears. Figure 3-18. Name Modify Dialog Box 2 Type a name in the New Name box. Names of servers may be up to 15 characters long. Legal characters - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 36
www.dell.com | support.dell.com Assigning Device Types While the 2161DS Console Switch unit automatically discovers cascade switches attached to your unit, you will need to specify the number of ports on the cascade switch though the Devices dialog box. The 2161DS Console Switch intially recognizes - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 37
. Device Modify Dialog Box 3 Choose the number of ports supported by your switch. 4 Click OK. 5 Repeat steps 2-4 for each port box to change the display order of servers and set a screen delay time for OSCAR. To access the Menu dialog box: 1 Press to launch OSCAR. The Main dialog box - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 38
www.dell.com | support.dell.com Figure 3-21. Menu Dialog Box To choose the display order of servers in . 2 Click OK. Setting a time to delay display of OSCAR allows you to complete a soft switch without OSCAR displaying. To perform a soft switch, see "Soft Switching". 38 Analog Port Operation - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 39
name Flag type by EID number Flag indicating that the user has been disconnected from all systems Flag indicating that Broadcast mode is enabled To access the Flag dialog box: 1 Press . The Main dialog box will appear. 2 Click Setup - Flag. The Flag dialog box appears. Analog Port - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 40
.dell.com | support.dell.com Figure 3-22. Flag Dialog Box To determine how the status flag is displayed: 1 Select Name or EID to determine what information will be displayed. 2 Select Displayed to show the flag all the time or select Timed to display the flag for only five seconds after switching - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 41
then need to type in your password to continue. Use the Security dialog box to lock your console with password protection, set or change your password and enable the screen saver. To access the Security dialog box: 1 Press . The Main dialog box will appear. 2 Click Setup - Security - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 42
www.dell.com | support.dell.com To password protect your console: 1 Set your password as described in the previous seconds then returns you to the Security dialog box. 6 Click OK. To log in to your console: 1 Press to launch OSCAR. The Password dialog box appears. 2 Type your - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 43
does not require a password to gain access to the Security dialog box, go to step 2. - or If your console is password protected, see the previous timeout in the Security dialog box. For more information, see "Setting Console Security". To view current user connections: 1 Press . The - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 44
www.dell.com | support.dell.com 2 Click Commands - User Status. The User Status dialog box appears. Figure 3-25. User Status Dialog Box 3 Click the letter of the user you wish - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 45
be accepted until the list update is complete. Preemption Preemption of a Local User by a Remote Administrator This occurs when a remote administrator attempts to take control of a server that is being accessed by a local user. If a preemption timeout value has been set, a message appears warning - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 46
www.dell.com | support.dell.com Figure 3-27. Preempt Dialog box NOTE: Typing a value of less than five will disable preemption timeout and will result in preemption without warning if the administrator preempts the local user. 4 Click OK. Preemption of a Remote Administrator by a Local User This - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 47
) or fail (red x) symbol appear to the left of each item as that test finishes.Table 3-5 details each of the tests. Figure 3-28. Diagnostics Dialog Box Table 3-5. Diagnostic Test Details Test Description Memory Test Reports on the condition of the main board RAM Firmware Cyclical Redundancy - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 48
www.dell.com | support.dell.com Table 3-5. Diagnostic Test Details Test Comm Interfaces Switch Controller Local and Remote Video LAN Connection On-line SIPs Offline SIPs Suspect SIPs Description Verifies that inter-board communication sub-systems are accessible and functional Verifies the switch - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 49
inactive. Make a note of each SIP in the suspect SIP list. You may want to troubleshoot each of these SIPs. Displaying Version Information Use the Version dialog box to display the 2161DS Console Switch and SIP firmware versions, as well as keyboard and mouse information for the currently selected - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 50
www.dell.com | support.dell.com Figure 3-30. Version Dialog Box 3 Click Digital to view the Digitizer unit firmware versions. The Digital Version dialog box appears. The top section identifies the digitizer subsystem versions. The center section identifies the current network settings. Click X or - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 51
. On these occasions, it may be necessary to reset the SIP when the tiered switch is not recognized. NOTE: If a reset is performed, when a 2161DS Console Switch is connected directly to a server, and not a Cascade Switch, the mouse/keyboard may fail to respond. When this occurs, the target server - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 52
dell.com | support.dell.com Figure 3-33. SIP Version Dialog Box 5 Click Reset. A warning message appears, warning that the function is for tiered switches sent to the 2161DS Console Switch. With communication re-established between the server and the 2161DS Console Switch, functionality is restored - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 53
Figure 3-34. Main Dialog Box Scanning Your System In scan mode, the 2161DS Console Switch automatically scans from port to port (server to server). You can scan up to 16 servers by specifying which servers you want to scan and - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 54
www.dell.com | support.dell.com Figure 3-35. Scan Dialog Box 3 The dialog box contains a listing of all the servers attached to your unit. Click to enable the check box - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 55
can choose to broadcast keystrokes and/or mouse movements independently. NOTE: You can broadcast to only one server per ARI connection. To access the Broadcast dialog box: 1 Press . The Main dialog box will appear. 2 Click Setup - Broadcast. The Broadcast dialog box appears. Analog - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 56
www.dell.com | support.dell.com Figure 3-37. Broadcast Dialog Box NOTE: Broadcasting Keystrokes - The keyboard state and Num Lock modes must be the same on all keyboards. While the 2161DS Console Switch attempts to send keystrokes to the selected servers simultaneously, some servers may inhibit and - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 57
To turn broadcasting off: In the Command dialog box, click to disable the Broadcast Enable check box. Figure 3-38. Command Dialog Box Analog Port Operation 57 - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 58
www.dell.com | support.dell.com 58 Analog Port Operation - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 59
Each individual Dell™ 2161DS Console Switch may be configured at the unit level through the configuration port on the back of the switch. All Terminal commands are accessed through a terminal or PC running terminal emulation software. Configuring the Terminal Menu The 2161DS Console Switch Terminal - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 60
www.dell.com | support.dell.com To access the Terminal menu: 1 Connect a terminal or system running terminal emulation software (such as HyperTerminal) to the configuration port on the back panel of the 2161DS Console Switch using the supplied serial cable. The terminal should be set to 9600 baud, - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 61
will be prompted to type the old password and a new one. 3 Re-enter the new password to verify. NOTICE: This password places your 2161DS Console Switch terminal in a secure mode. This password should be guarded like any network password and care should be taken to avoid forgetting or misplacing it - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 62
www.dell.com | support.dell.com 62 Terminal Operations - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 63
Dell at support.dell.com. Save the FLASH upgrade file to the appropriate directory on the TFTP server. Once this is complete, the following steps will upload the new FLASH file. To upload a new FLASH file to the 2161DS Console Switch: 1 Connect a terminal or PC running terminal emulation software - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 64
support.dell.com 9 The 2161DS Console Switch will begin the FLASH upgrade process. On-screen indicators will display the upgrade progress. When the upload is complete, the 2161DS Console Switch will reset and upgrade the internal subsystems. CAUTION: Do not cycle power to the 2161DS Console Switch - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 65
Figure 5-41. SIP Load Dialog Box 4 Click OK to initiate the upgrade and return to the SIP Status dialog box. To upgrade SIP firmware individually: 1 Press . The Main dialog box will appear. 2 Click Commands-Display Versions. The Version dialog box appears. Figure 5-42. Version Dialog - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 66
www.dell.com | support.dell.com Figure 5-43. SIP Selection Dialog Box 4 Select the SIP that you wish to upgrade and click the Version button. The SIP Version dialog box appears. Figure 5-44. SIP Version Dialog Box 5 Click the Load Firmware button. The SIP Load dialog box appears. 66 Appendices - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 67
Dell 8-port and 16-port Console Switch Visit the support.dell.com web switches is shown in the F: field. The minimum version required for the 8-port is version 2.1.3 and version 1.3.3 for the 16-port switch. 2 Go to support.dell.com. 3 Search using the keywords Console Switch. 4 Follow instructions - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 68
are version shown in the S: field. The minimum version required for the 8-port is version 2.1.2.1, and version 1.3.2.0 for the 16-port. e Go to support.dell.com. 2 Search using the keywords Console Switch. 3 Follow instructions to download the latest upgrade for your cascaded unit. 68 Appendices - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 69
Specifications Server Ports Number 16 SIP Types PS/2 and USB, Dell branded or Avocent. Sun and Serial, Avocent AVRIQs only. and vertical Plug and Play DDC2B Video Resolution Analog Port Maximum 1600x1280@ 75 Hz. Digital Port Maximum 1280 x 1024 @ 75 Hz Analog Port Maximum 1600 x 1200 @ - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 70
www.dell.com | support.dell.com tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 71
Agency Approvals UL 1950, CSA C22. 2 No. 950, EN60950, IEC 950 FCC part 15A, EN55022, EN50082 Republic of Korea EMI Standard Certificate Number: E-F900-01-2012 (A) Appendices 71 - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 72
www.dell.com | support.dell.com 72 Appendices - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 73
of software • Non-Dell-branded and Solution Provider Direct products and accessories • Problems that result from: - External causes such as accident, abuse, misuse, or problems with electrical power - Servicing not authorized by Dell - Usage that is not in accordance with product instructions - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 74
warranty period is not extended if we repair or replace a warranted product or any parts. Dell may change the availability of limited warranties, at its discretion, Dell Service Tag or order number available. Individual Home Consumers: U.S. Only Technical Support 1-800-624-9896 Customer Service - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 75
price details on how to obtain service. How will you fix my product? We use new and refurbished parts made by various manufacturers in performing warranty repairs and in building replacement parts and systems. Refurbished parts and systems are parts or systems that have been returned to Dell - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 76
will be subject to the terms and conditions of the original service or limited warranty agreement and Dell's terms and conditions of sale located at www.dell.com. Dell cannot guarantee the authenticity of the products, limited warranties, service or support or the accuracy of the listings of - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 77
of the software • Non-Dell branded and Solution Provider Direct products and accessories • Problems that result from: - External causes such as accident, abuse, misuse, or problems with electrical power - Servicing not authorized by Dell - Usage that is not in accordance with product instructions - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 78
Support 1-800-387-5757 Customer Service 1-800-326-9463 (Extension 8221 for Individual Consumers) Dell-Branded Memory 1-888-363-5150 What will Dell product to you freight collect. If we determine that the problem is not covered under this warranty, we will notify you and inform you of service - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 79
product(s). We are not responsible for lost or corrupted data. What if I purchased a service contract? If your service contract is with Dell, service will be provided to you under the terms of the service contract. Please refer to that contract for details on how to obtain service. Dell's service - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 80
or invoice; you are responsible for those. To return products, you must call Dell Customer Service at 1-800-387-5759 to receive a Credit Return Authorization Number. You must ship the Dell Software and Peripherals products back to Dell in their original manufacturer's packaging (which must be in - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 81
number, name and address of the customer, and details of symptoms and configuration at the time of malfunction, including peripherals and software used. Otherwise, Dell may refuse the guarantee claim. Upon diagnosis of a warranted defect, Dell will make arrangements and pay for ground freight and - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 82
dell.com | support.dell.com Dell of hardware and/or software; OR • REPLACE the problems with electrical power, usage not in accordance with product instructions, misuse, neglect, alteration, repair, improper installation, or improper testing. How to Obtain Warranty Service To obtain warranty service - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 83
card for complete warranty details. Intel's Commitment to products. If necessary, special software or hardware solutions (sometimes known as "work arounds") are implemented in the system design to prevent computer users from encountering the problem our Technical Documentation Service. At Intel, - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 84
www.dell.com | support.dell.com 84 - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 85
Numerics 2161DS Console Switch Configuring, 20 Installing, 19 2161DS Console Switch Unit Installing, 18 A Address Resolution Protocol. See ARP. analog port, 29 ARI, 22, 34, 55 ARP, 21 Auto-Negotiate, 21 AVRIQ, 15 B BootP, 20 Broadcast dialog box, 55 Broadcasting, 55 C Cascade Switch Adding, 24 - Dell PowerEdge 2161DS | Dell 2161DS Console Switch Hardware and
OSCAR User&am - Page 86
PEM. power indicator, 20 Preemption, 43 Timeout, 45 R Rack Mounting, 16 Remote Console Switch Software, 10, 15-16 S Scan dialog box, 53 Scan mode, 54 Cancelling , 48 Switch Controller, 48 System Diagnostics Running, 46 T Terminal Applications, 20, 59 Terminal Menu, 59 Terminal menu Accessing, 60 TFTP