Dell PowerEdge 2950 Hardware Owner's Manual (PDF) - Page 22
CPU Machine Chk, PS # Missing, PS # Status, PS # Predictive, E161C, PS # Input Lost, PS # Input Range - lcd
View all Dell PowerEdge 2950 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Table 1-6. LCD Status Messages (continued) Code E1422 E1610 E1614 E1618 E161C E1620 E1624 E1710 Text Causes Corrective Actions CPU Machine Chk The system BIOS has reported a See "Getting Help" on page 147. machine check error. PS # Missing No power is available from the specified power supply; specified power supply is improperly installed or faulty. See "Troubleshooting Power Supplies" on page 118. PS # Status No power is available from the specified power supply; specified power supply is improperly installed or faulty. See "Troubleshooting Power Supplies" on page 118. PS # Predictive Power supply voltage is out of See "Troubleshooting Power acceptable range; specified power Supplies" on page 118. supply is improperly installed or faulty. PS # Input Lost Power source for specified power supply is unavailable, or out of acceptable range. Check the AC power source for the specified power supply. If problem persists, see "Troubleshooting Power Supplies" on page 118. PS # Input Range Power source for specified power supply is unavailable, or out of acceptable range. Check the AC power source for the specified power supply. If problem persists, see "Troubleshooting Power Supplies" on page 118. PS Redundancy The power supply subsystem is no See "Troubleshooting Power longer redundant. If the last Supplies" on page 118. supply fails, the system will go down. I/O Channel Chk The system BIOS has reported an See "Getting Help" on page 147. I/O channel check. 22 About Your System