Table 1-5. LCD Status Messages (continued) Code Text Causes Corrective Actions E201F DRAC Config Dell remote access controller (DRAC) configuration failure. Check screen for specific error messages. Ensure that DRAC cables and connectors are properly seated. If problem persists, see your DRAC documentation. E2020 CPU Config Processor configuration failure. Check screen for specific error messages. E2021 Memory Population Incorrect memory configuration. Memory population order incorrect. Check screen for specific error messages (see "Troubleshooting System Memory" on page 174). E2022 POST Fail General failure after video. Check screen for specific error messages. E2110 MBE DIMM # & # One of the DIMMs in the See "Troubleshooting set implicated by "# & #" System Memory" on has had a memory multi-bit page 174. error (MBE). E2111 SBE Log Disable DIMM # The system BIOS has See "Troubleshooting disabled memory single-bit System Memory" on error (SBE) logging, and will page 174. not resume logging further SBEs until the system is restarted. "#" represents the DIMM implicated by the BIOS. E2112 Mem Spare DIMM # The system BIOS has spared See "Troubleshooting the memory because it has System Memory" on determined that the page 174. memory had too many errors. "# & #" represents the DIMM pair implicated by the BIOS. 30 About Your System