Dell PowerSwitch S4048T-ON Networking S4048T-ON Getting Started Guide
Dell PowerSwitch S4048T-ON Manual
View all Dell PowerSwitch S4048T-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell PowerSwitch S4048T-ON manual content summary:
- Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 1
Dell Networking S4048T-ON Getting Started Guide Regulatory Model: 6JWX4 - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 2
and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 3
see the following information, available on the Dell Support website-www.dell.com/support: • The Dell Networking S4048T-ON Installation Guide describes installation and replacement procedures. • The Dell Networking Configuration Guide for the S4048T-ON System describes software configuration. • The - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 4
network equipment building system (NEBS) compliant, you must follow the instructions detailed in this chapter. To be NEBs compliant, orient your interfaces metallically to OSP wiring. WARNING: If you install and connect the S4048T-ON to a commercial AC power source, you must connect the system to - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 5
wire that uses 4- in/lb to secure your system to the frame. NOTE: The S4048T-ON can operate at -40.5 to -60 VDC at a maximum current level of or at 100-240 VAC at a maximum current level of 7.1A. NOTE: The S4048T-ON is Earthquake Z4-compliant when you attach the ReadyRails to the frame using threaded - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 6
installation This information describes installation of the S4048T-ON system. Dell recommends completing the installation procedures in the • Supply Power and Power Up the System • After Installing the S4048T-ON Operation and safety considerations Before installing the switch, review these operation - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 7
• Airflow around the switch and through the vents is unrestricted. • Temperature around the unit does not exceed 113°F (45°C). If the switch is in a closed or multi-rack assembly, the temperature might be higher than normal room temperature. • Humidity around the switch does not exceed 95 percent. • - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 8
Read the safety instructions in your Safety, Environmental, and Regulatory information booklet before you begin. Ground and bracket installation Install the ground (GND) lug and bracket assembly, with a ground wire attached, before you install the S4048T-ON switch in a rack. Dell supplies a kit with - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 9
Figure 1. Ground wire end and GND lug opening 2 Apply the thread-locker compound to the two flat head screws, then attach the GND lug to the L-bracket. Hardware installation 9 - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 10
Screws, GND lug, and L-bracket 3 Attach the assembly to the S4048T-ON chassis: a Apply the thread-locker compound to the two pan head screws. b Attach the GND lug and bracket assembly to the two-hole chassis ground connector nuts on the S4048T-ON PSU side, tightening the screws to ensure torque from - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 11
Figure 3. Assembly to S4048T-ON PSU-side attachment CAUTION: Take care not to damage the attached is provided to easily configure your rack so that you can install your switch. Use the Dell ReadyRails™ system in 1U front-rack and two-post installations. The ReadyRails system includes two separately - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 12
1U tool-less configuration NOTE: Your system is not NEBS Earthquake Z4-compliant if you use the 1U tool-less square-hole or two-post installation methods. 1 Face the ReadyRails flange ears outward then place the rail between the left and right vertical posts. Align and seat the back flange rail pegs - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 13
Two-post flush-mount configuration NOTE: Your system is not NEBS Earthquake Z4-compliant if you use this installation method. 1 For this configuration, remove the latch castings from the front side of each ReadyRails assembly, item 1. To remove the two screws and latch casting from each front flange - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 14
Figure 5. Two-post flush-mount configuration Two-post center-mount configuration NOTE: Your system is not NEBS Earthquake Z4-compliant if you use this installation method. 1 Slide the plunger bracket rearward until it clicks into place and secure the bracket to the front post flange with two user- - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 15
3 Repeat this procedure for the second rail. Figure 6. Two-post center-mount configuration Four-post threaded configuration NOTE: To be NEBS Earthquake Z4-compliant, you must remove the tool-less latch castings described in Step 1. 1 Remove the latch castings from each end of the ReadyRails - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 16
Figure 7. Four-post threaded configuration System installation You can mount the system in the 1U front-rack or 1U two-post flush or center configurations. For the 1U two-post flush or center configurations, slide the system into the rails in the same manner as the four-post configurations. The - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 17
1U front-rack installation Configure the rails that are attached to the system. 1 Attach the inner-chassis member switch rails to the switch, items 1 and 2. Item 3 shows the detail for the front standoff with the locking tab. Figure 8. Switch rail attachment 1 Locking feature 3 Front standoff with - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 18
ON front-rack configuration installation 1 Chassis 3 Rail locking feature 2 Rail end Ground wire installation After you have installed the S4048T-ON switch in a rack, complete the installation of the ground wire. You previously installed the GND lug and bracket assembly, with ground wire attached - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 19
You must supply: • One two-hole UL-certified GND lug to attach the ground wire to the rack • Two National Electric Code (NEC)-compliant screws to attach the GND lug to the rack • Anti-oxidant compound • Crimping tool 1 Measure and cut a length of wire sufficient to reach between the system-installed - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 20
The S4048T-ON supports two hot-swappable power supplies with integrated fans that provide cooling for the chassis. The system supports AC two slots, PSU1 and PSU2. Although the switch can run on one PSU, Dell highly recommends using two PSUs for full redundancy and more cooling. To avoid - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 21
switch PSU to the external power source only after the chassis is mounted in a rack or cabinet. CAUTION: The S4048T-ON contains two power cords. Disconnect both power cords before servicing. DC power supply to power source connection Each DC PSU comes with a connector cable. One cable is provided - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 22
slots must have operating fan units. If you do not install a module in each slot, the system shuts down in one minute. NOTE: The system supports two airflow direction options. You can only use a single direction in a chassis. • Normal is airflow from the I/O side to the power supply. • Reversed is - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 23
and six quad small form-factor pluggable plus (QSFP+) optical ports. For a list of supported optics, see the S4048T-ON Specification Sheet at https:// www.dell.com/support/ or contact your Dell Networking representative. CAUTION: ESD damage can occur if the components are mishandled. Always wear an - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 24
above and below the ports. Supply Power and Power Up the System Dell Networking recommends reinspecting your system prior to powering up. Connecting the power is steadily lit. After Installing the S4048T-ON After you have securely installed and powered on the S4048T-ON, to configure your system, - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 25
if you already have Dell Networking OS 9.x installed on your system from the factory. If you are installing a third-party OS, see your third-party OS documentation. NOTE: For further information on the S4048T-ON system, see the documents listed in About this guide. Topics: • Initial configuration - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 26
Enable secret password • Enable password • Telnet password Navigating CLI modes The Dell OS prompt changes to indicate the CLI mode. You move linearly through right-hand side of the S4048T-ON system as you face the PSU side of the chassis, as shown. Figure 14. S4048T-ON RS-232 management and - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 27
-45 copper cable into the console port. Use a rollover cable to connect the S4048T-ON console port to a terminal server. 2 Connect the other end of the as follows: Table 1. Pin assignments between the console and a DTE terminal server S4048T-ON console port Signal RJ-45 to RJ-45 RJ-45 to RJ-45 RJ - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 28
individual interface, use the switchport command in INTERFACE mode. NOTE: For detailed information about configuring Layer 2, see the Dell Networking Configuration Guide for the S4048T-ON System. You cannot configure switching or Layer 2 protocols such as spanning tree protocol (STP) on an interface - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 29
The host name appears in the prompt. The default host name is Dell. Host names must start with a letter, end with a letter or Create a host name. CONFIGURATION mode hostname name Remote access You can configure the S4048T-ON system for Telnet remote access. The system has a dedicated management port - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 30
S4048T-ON to the network from which you are accessing the S4048T-ON remotely. Management routes are separate from IP routes and are used to manage the S4048T- configuration using a stronger, MD5-encryption method. Dell Networking recommends using the enable secret password. 30 Software - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 31
• To access EXEC Privilege mode, create a password. CONFIGURATION mode enable [password | secret] [level level] [encryption-type] password Port-based VLAN creation The default VLAN, VLAN 1, is part of the system startup configuration and does not require configuration. To configure a port-based VLAN - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 32
correctly. NOTE: Replace the battery only with the same or an equivalent type. Dispose of the batteries according to the manufacturer's instructions. Table 2. S4048T-ON chassis physical design Parameter Height Width Depth Specifications 1.71 inches (43.5 mm). 17.09 inches (434 mm). Chassis: 18.11 - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 33
Parameter Storage temperature Storage and nonoperating humidity Maximum thermal output Maximum operational altitude Maximum nonoperational altitude Shock Specifications -40° to 158°F (-40° to 70°C). 5 to 95 percent (RH), noncondensing. 1568 BTH/hr. 10,000 feet (3,048 meters). No performance - Dell PowerSwitch S4048T-ON | Networking S4048T-ON Getting Started Guide - Page 34
Parameter Specifications −40.5V/24.0A −48V/19.2A −60V/ 16.0A (with fan). Start up VDC (voltage when the system is powered on) Start off VDC (voltage during the boot up process) 39.0+/−1.5V. 37.5+/−1.5V. 34 Technical specifications
Dell Networking S4048T-ON
Getting Started Guide
Regulatory Model: 6JWX4