Edimax EdiView32 Manual

Edimax EdiView32 Manual

Edimax EdiView32 manual content summary:

  • Edimax EdiView32 | Manual - Page 1
    EdiView 32 User Manual 04-2013 / v1. 0
  • Edimax EdiView32 | Manual - Page 2
    1. System Requirements...5 2. Software Installation...6 EdiView 32 11 1. Monitoring ...11 Activate/Stop Camera...16 1-3-6. Manual Recording...16 1-3-7. Checklist or Monitor Frame 19 1-4-4. Multi-Window Support...21 1-5. Aspect Controller (Pan, 1-8-2. Switch Streaming ...25 1-8-3. Remove Video Streaming
  • Edimax EdiView32 | Manual - Page 3
    30 3-2. Video Timeline Setup...30 3-3. Video Player...31 3-3-1. Play Time Scroll Bar ...32 3-3-2. Power Saving Mode ...32 3-3-3. Playback Speed ...32 3-3-4. Clip Skipping...32 3-4. Export Video Clip ...32 3-4-1. Video Clip Export Length ...33 3-4-2. Video Clip Export Resolution 33 3-4-3. Video Clip
  • Edimax EdiView32 | Manual - Page 4
    General ...43 Take Picture ...43 Computer - Screen Saver ...43 Computer - Screen Shutdown 43 Computer - Sleep Mode...44 Language ...44 Account - Change Password 44 User Management ...44 SMTP ...46 Camera Groups ...46 Recording ...50 Recording Path...51 Reserve Available Hard Disk Storage Space 51
  • Edimax EdiView32 | Manual - Page 5
    Installation 1. System Requirements *1 The maximum decode frame rate not considering Ethernet connection speed. Video format: MPEG4, resolution: 640x480, quality: medium/normal Figures above can vary due to difference in video source and system setup. 5
  • Edimax EdiView32 | Manual - Page 6
    2. Software Installation 6
  • Edimax EdiView32 | Manual - Page 7
    7
  • Edimax EdiView32 | Manual - Page 8
    Select the installation destination location. It is recommended to select the default location. If the installation is a software update, please select the destination location used in the last installation. 8
  • Edimax EdiView32 | Manual - Page 9
    9
  • Edimax EdiView32 | Manual - Page 10
    Installation complete. Click 'Close' to complete the installation process. 10
  • Edimax EdiView32 | Manual - Page 11
    EdiView 32 1. Monitoring When the program starts up, a window will appear requesting user name and password. The default username is 'admin'and password is '1234'. You should change the password immediately after your first login, please refer to Settings for instructions. Navigate the software
  • Edimax EdiView32 | Manual - Page 12
    the "Lock" icon to immediately logout of the software and return to the login screen. The correct username and password is required to login. The default username is "admin"and password is "1234". You can use the "Screen Lock" function to quickly switch user accounts. 1-3. Camera List Click the icon
  • Edimax EdiView32 | Manual - Page 13
    the camera is active. Grey means camera is not active. Link (D): Green indicates software is linked to the camera. Grey means it is not. Event Recording (E): Red . Grey means it is not. Manual Recording (F): Red indicates the camera is currently executing manual recording. Grey means it is not
  • Edimax EdiView32 | Manual - Page 14
    open: Camera Name: Enter a reference name for the camera HTTP Address: Displays the IP address of the camera HTTP Port: The default port value is 80 Username: Username used to login User Password: Password used to login. Camera Vender/Model: Click 'Search...' to search for camera model
  • Edimax EdiView32 | Manual - Page 15
    automatically. If a match cannot be made, the camera manufacturer and model number will need to be entered manually. Live View & Recording Channel: If the IP Camera supports multiple video streaming, you can set 'Live View Channel' and 'Recoding Channel' as independent streaming. For example,
  • Edimax EdiView32 | Manual - Page 16
    you can try to reconnect using a different account name, password, IP address or HTTP port. If a connection cannot be made, a browser can be used to see if the connection is functional. 1-3-6. Manual Recording When camera connection is made, 'Manual Recording' button can be clicked at any time to
  • Edimax EdiView32 | Manual - Page 17
    1-3-8. Show/Hide Camera Information Display or hide camera information such as IP address, frames per second (FPS), bitrate and audio/video format. You can click on "Address" to open the IP camera's web server home page. 1-4. Monitor Layout The monitor frame panel displays user defined layout for
  • Edimax EdiView32 | Manual - Page 18
    All frames displayed can be used as a display source for the "Sequential Monitor Frame". 1-4-1. Add/Remove Monitor Monitor frames can be added or removed to suit user's needs. This can be done in Add Monitor Frame Window as shown below: You can customize monitor frame layout if required (see next
  • Edimax EdiView32 | Manual - Page 19
    new pop up window select the number of new rows and columns of customizable monitor frames that you want to add. Click 'OK' to commence customizing your monitor frame layout. In the customized monitor frame, you can use 'Merge Cells' or 'Cancel a Merge' to allocate monitor frame as shown below.
  • Edimax EdiView32 | Manual - Page 20
    click 'Add' button. A setup window will appear as shown below: Add Sequential Monitor Frame In the image above, the left frame (Source) represents the monitor frames that was previously setup, all these frames can become the 20
  • Edimax EdiView32 | Manual - Page 21
    the streaming camera into the sequential monitor frame - instead you must configure it from the "Source Monitor Frame". 1-4-4. Multi-Window Support CMS supports multiple windows, with no restrictions on the number that can be opened. Its operation is intuitive; inside the monitor allocation panel
  • Edimax EdiView32 | Manual - Page 22
    function to sequential the camera horizontal/vertical. If the selected camera does not support PTZ, this control panel becomes inoperable. 1-6. EMap Navigator This frame allows user to browse the physically location of the IP Camera. The image below is a full map view. The green selector represents
  • Edimax EdiView32 | Manual - Page 23
    to 'Map Navigator' and drag the green selector to move the map. 1-7. Digital Zoom Control Digital emulation is used to zoom and move IP Camera video streaming. Any monitor frame can be individually configured with Digital Zoom, allowing you to achieve multi-views with only a single high definition
  • Edimax EdiView32 | Manual - Page 24
    control panel, and use the mouse to drag and move the field of display. 1-8. Monitor Frame Setup 1-8-1. Add Video Streaming There are 2 methods to add IP camera video streaming to the monitor frame. The first method is to drag any camera status/preview row to the monitor frame. The second method
  • Edimax EdiView32 | Manual - Page 25
    different monitor frame and use digital zoom control to achieve multi-view with a single camera. 1-8-2. Switch Streaming Use your mouse to drag and drop two different monitor frames to switch video streaming. 1-8-3. Remove Video Streaming Click the right mouse button on a monitor frame, and a window
  • Edimax EdiView32 | Manual - Page 26
    26
  • Edimax EdiView32 | Manual - Page 27
    2. EMap Maps can provide a visual physical overview of your IP Camera location, making it easy to quickly select individual cameras and monitor video streaming. 2-1. Add/Remove EMap Click 'Add' button. Select the map file within '
  • Edimax EdiView32 | Manual - Page 28
    2-2-3. Image Preview Click the camera icon once to preview video streaming. Double-clicking the icon will display camera's monitor frame. 2-2-4. Image Transparency If the mouse cursor is not on top of the camera icon, the video streaming will become semi-transparent to allow use to control the map.
  • Edimax EdiView32 | Manual - Page 29
    2-4. Interact The cameras on the camera list, 'Map Navigator' and the map will all respond simultaneously to user selection. For example, when you want to search for a particular camera, you can select it directly according to its location on the 'Map Navigator'. 29
  • Edimax EdiView32 | Manual - Page 30
    the toolbar. The toolbar has timeline markings (between 2 hours to 1 minute intervals) as well as being subdivided into three rows indicating: 'Scheduled', 'Manual' and 'Event'. Timeline Scale: Use the mouse scroll wheel on the playback toolbar to expand/shrink the playback timeline. This can also
  • Edimax EdiView32 | Manual - Page 31
    Playback Previous/Next Clip: Use the 'Image Section' toolbar to change the current video playback Refresh Playback Video: If camera is currently under recording, the 'Refresh' button on the toolbar can be used to update latest video data on the playback toolbar. You can "Refresh" immediately after
  • Edimax EdiView32 | Manual - Page 32
    will indicate the current selected time within the clip 3-3-2. Power Saving Mode All video players support 'Power-Saving Mode'. In this mode, loading of the computer's processing efficiency will substantially compatibility of player, all exported video clips are WMV (Windows Media Video) format. 32
  • Edimax EdiView32 | Manual - Page 33
    3-4-1. Video Clip Export Length Adjust the length between 2 black keys (starting point/end point) on the video player time scroll bar to set the length of exported clip. 3-4-2. Video Clip Export Resolution The minimum export clip resolution is 80*60, and the maximum is 1920*1080. The default
  • Edimax EdiView32 | Manual - Page 34
    Higher quality takes longer time to export. 3-4-4. Video Clip Export Frame Rate Selected frame rate of the clip being exported. If the frame rate is larger than the camera streaming frame rate, then video compression of the exported frame rate will be camera streaming actual frame rate. The default
  • Edimax EdiView32 | Manual - Page 35
    to export audio accompanying video. 3-4-7. Export File Path Select the storage destination to place exported video clips. 3-5. Multiple Playbacks The CMS supports multiple video clip playbacks without limitation of the number of windows. This allows you to browse multiple image clips at once. Double
  • Edimax EdiView32 | Manual - Page 36
    one camera present in the camera list on monitor page. In the main function bar, click 'Recording' to enter the recording page. Then choose any IP camera from left list box. Click 'Schedule Setting' on the scheduled recording section on the right work space will bring up 'Schedule Setting' window as
  • Edimax EdiView32 | Manual - Page 37
    Schedule selector: Record schedule editor is organized in units of 7 days, from Monday to Sunday. Each day is separated into 96 time slots, with each time slot representing 15 minutes. Left click and drag the mouse cursor will set the recording period, selected time will also be displayed on top as
  • Edimax EdiView32 | Manual - Page 38
    orange shading. While white/grey time slots will represent uncommitted time frame as shown below: 4-1-2. Clear Mode The time frame that has been selected with mouse cursor will be reverted to unscheduled if the same time period was previously selected for scheduled recording (orange shading). The
  • Edimax EdiView32 | Manual - Page 39
    no limitation on the number of detection zones. - Graphical quantization of object movement. - Every detection zone has independent triggering conditions that can be set individually - Support 'Time Recovery' recording mechanism - Support scheduled recording 39
  • Edimax EdiView32 | Manual - Page 40
    A camera must be selected in the left camera list for motion detection recording. 4-2-2. Recording Before Alarm Trigger As part of time recovery mechanism, video recording can activate before the trigger event. Preset values are 0, 1, 3, 5 and 10 seconds. 4-2-3. Stop Recording After Alarm Trigger
  • Edimax EdiView32 | Manual - Page 41
    below: Add Detection Zone Click 'Add' button to add a new detection zone. There is no restriction on the number of detection zones. When the IP camera's resolution has been changed, all associated detection zones will be removed. Resize and Move On the bottom right hand side of the white detection
  • Edimax EdiView32 | Manual - Page 42
    Sensitive: Configures the sensitivity to image change within the detection zone. Configurable values are high, normal and low. Trigger Level: On the bar, use the mouse cursor to move the trigger value (red line). When movement vector values (green bars) exceed the trigger value, motion alarm will be
  • Edimax EdiView32 | Manual - Page 43
    Screen Saver Configures screen saver activity. For example, you might prefer the system not entering screen saver mode when the monitoring software is running. 5-1-3. Computer - Screen Shutdown This configures computer monitor activation status. For example, you might prefer the system not shutting
  • Edimax EdiView32 | Manual - Page 44
    Set up the monitoring software user interface language. 5-1-6. Account - Change Password Change the password used to activate this monitoring software. Click 'Change Password' and enter the old password, along with a new password in the new password and confirm new password field. Click 'OK' to
  • Edimax EdiView32 | Manual - Page 45
    User List: List of all available users. Add User: Click 'Add', and a setup window will appear as shown below. Remove user: Click 'Remove' to remove user account. Change User Group: Change the privilege level of the selected user account. 45
  • Edimax EdiView32 | Manual - Page 46
    preset for three most common SMTP servers such as, Hotmail/MSN/Live、Yahoo! and Gmail. SMTP can also be set manually. Login: Enter the user name and password for your mailbox. The user name is usually your e-mail address. Sender: Enter the name and e-mail address to display 5-1-9. Camera Groups 46
  • Edimax EdiView32 | Manual - Page 47
    When there are a large number of IP cameras, they can be allocated into groups for management. Left field of the Camera Group window contains camera groups; the right field contains cameras allocated
  • Edimax EdiView32 | Manual - Page 48
    Remove Camera Group: Select the camera group that you would like to remove, and click 'Remove'. If the camera group has more than one camera associated with it, then it cannot be removed. Move Selection to Another Group: Click on the cameras that you want to regroup, and click on 'Move to'. Select
  • Edimax EdiView32 | Manual - Page 49
    49
  • Edimax EdiView32 | Manual - Page 50
    5-2. Recording Click 'Setting' on the main tool bar to enter setup page. Click 'Recording' on the left toolbar and the right work space will display recording setup as shown below: 50
  • Edimax EdiView32 | Manual - Page 51
    path to store IP camera's recorded video has reached the allocated storage capacity, the video recording service will be stopped without any video clips stored. If seconds of video clip being emotively recorded when the user activates manual video recording. 5-3. Screen Setup Click 'Setting' on main
  • Edimax EdiView32 | Manual - Page 52
    5-3-1. OSD Setting There are 7 settings available in the left hand side of screen setup work space, on the right hand side there is a preview screen. User can adjust the display content for assisting the management of monitoring. The first 4 settings are used for setting message content displayed in
  • Edimax EdiView32 | Manual - Page 53
    For example, if you want to define new events and actions setting: A. Select the camera in the events list and add event, e.g. motion detected. B. Select event, and in the actions list add new action, e.g. send e-mail. Setup order is (1) Select camera (2) Add event (3) Select event (4) Add action.
  • Edimax EdiView32 | Manual - Page 54
    Add Event: Select the camera, click 'Add' and select the new events that you would like to add in the pop up window. 54
  • Edimax EdiView32 | Manual - Page 55
    The event list window will display events that can still be added to the list. Events that have already been added will not be displayed. Remove Event: Select the event in events list, and click 'Remove'. Copy Event: Select events in the list and click 'Copy', a pop out window 'Copy event to...'
  • Edimax EdiView32 | Manual - Page 56
    Add Action: Select the camera event, click 'Add', and select desired action in the new pop up window. If selected action is send e-mail, after clicking 'OK', an e-mail setup window will appear as shown below; add/remove receiver, enter mail title and message content. Click 'Select Camera...' to
  • Edimax EdiView32 | Manual - Page 57
    This action is related to SMTP server setup; in order to successfully send e-mail, the SMTP server must be configured and tested. Please refer to chapter SMTP for related setup. Remove Action: Select action in action list, click 'Remove'. Set Action: Select the desired action in action list, click '
  • Edimax EdiView32 | Manual - Page 58
    , optical, chemical, manual or otherwise, without the prior written permission from Edimax Technology Co., Ltd. Edimax Technology Co., Ltd. cost of all necessary servicing, repair, and any incidental or consequential damages resulting from any defect in the software. Edimax Technology Co., Ltd.
  • Edimax EdiView32 | Manual - Page 59
    59
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59

EdiView 32
User Manual
04-2013 / v1.
0