Fluke FLK-TI200 60HZ User Manual

Fluke FLK-TI200 60HZ Manual

Fluke FLK-TI200 60HZ manual content summary:

  • Fluke FLK-TI200 60HZ | User Manual - Page 1
    Ti200, Ti300, Ti400 Thermal Imagers Users Manual PN 4281773 September 2013 © 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
  • Fluke FLK-TI200 60HZ | User Manual - Page 2
    shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days
  • Fluke FLK-TI200 60HZ | User Manual - Page 3
    Touch Screen 14 How to Use the Menus 15 Image Capture 15 IR-PhotoNotes 16 Voice Annotation (Recording 17 Listen to a Voice Annotation (Recording 17 Edit Captured Infrared Image 18 Save Captured Infrared Image 18 Micro SD Memory Card 19 Temperature Measurement 20 SmartView Software 20 i
  • Fluke FLK-TI200 60HZ | User Manual - Page 4
    Spot Markers 26 Center Box 27 Image Menu 28 Palette 28 IR-Fusion® Technology 29 Color Alarms 30 Display Graphics Presentation 31 Logo 31 Camera Menu 32 LaserSharp™ Auto Focus System 32 Backlight 33 Torch 33 Memory Menu 34 Review Image Files 34 Delete Image Files 34 Settings Menu 35
  • Fluke FLK-TI200 60HZ | User Manual - Page 5
    List of Tables Table Title Page 1. Symbols 4 2. Accessories 5 3. Features and Controls 11 4. Overview of Controls 14 5. Palettes 28 List of Figures Figure Title Page 1. Lens Cover Laser Warning 3 2. Add-On Lens Installation 6 3. SD Memory Card Insertion and Removal 19 4. Level and
  • Fluke FLK-TI200 60HZ | User Manual - Page 6
    Ti200, Ti300, Ti400 Users Manual iv
  • Fluke FLK-TI200 60HZ | User Manual - Page 7
    The Fluke Ti200, Ti300, and Ti400 Thermal Imagers (the Product or Imager) are handheld, infrared imaging cameras for use in many applications. These applications include equipment troubleshooting, preventive and predictive maintenance, building diagnostics, and research and development. All Imagers
  • Fluke FLK-TI200 60HZ | User Manual - Page 8
    your Product, visit http://register.fluke.com. To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. Safety Information A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures
  • Fluke FLK-TI200 60HZ | User Manual - Page 9
    Thermal Imagers Safety Information Additional laser warning information is on the inside of the Product lens cover, see Figure 1. FLUKE CORPORATION EVERETT, WA USA www.patentlabel.com/fluke Figure 1. Lens Cover Laser Warning hie05.eps  Warning To prevent personal injury: • Read all safety
  • Fluke FLK-TI200 60HZ | User Manual - Page 10
    Ti300, Ti400 Users Manual • See used on the Imager and in this manual. Table 1. Symbols Symbol Description Symbol Description  Important information. See manual.  Warning. handler per local regulations. Contact your authorized Fluke Service Center for recycling information. This product
  • Fluke FLK-TI200 60HZ | User Manual - Page 11
    Thermal Imagers Radio Frequency Data Radio Frequency Data See page 39 for instructions on how to access digital copies of the radio licenses on the Imager. Accessories Table 2 is a list of the accessories available for the Imager. Table 2. Accessories Model FLK-TI-SBP3 Description Smart
  • Fluke FLK-TI200 60HZ | User Manual - Page 12
    Ti200, Ti300, Ti400 Users Manual Figure 2. Add-On Lens Installation hie08.eps 6
  • Fluke FLK-TI200 60HZ | User Manual - Page 13
    or Right-hand use) • Users Manuals in print (English, Spanish, French, German, Chinese)[2] • Users Manuals on CD[2] • SmartView® Software • Warranty Registration Card Note [1] Fluke recommends the memory card that is supplied with the Imager or available from Fluke. Fluke does not warrant the use
  • Fluke FLK-TI200 60HZ | User Manual - Page 14
    Ti200, Ti300, Ti400 Users Manual Battery Before you use the Imager for the first time, charge the battery for a minimum of two and one-half hours. The battery status shows on the five-segment charge indicator. 
  • Fluke FLK-TI200 60HZ | User Manual - Page 15
    Thermal Imagers Before You Start On-Imager AC Power Socket 1. Connect the ac power adapter into an AC wall outlet and connect the dc output to the Imager Make sure that the Imager is near room temperature before you connect it to the charger. See the charging temperature specification. Do not charge
  • Fluke FLK-TI200 60HZ | User Manual - Page 16
    Ti200, Ti300, Ti400 Users Manual Optional 12 V Vehicle Charger 1. Connect the 12 V adapter into the 12 V accessory socket of the vehicle. 2. Connect the output to the ac power socket of the Imager. 3. Charge until the indicator shows full on the screen. 4. Disconnect the 12 V adapter and Imager when
  • Fluke FLK-TI200 60HZ | User Manual - Page 17
    Thermal Imagers Features and Controls Features and Controls Table 3 shows the Imager features and controls. Table 3. Features and Controls 3 2 4 5 Ti200 IR FUSION TECHNOLOGY 1 6 11 12 7 8 10 9 13 Item  Description HDMI Connection USB Cable Connection Microphone Speaker LCD Display  Power
  • Fluke FLK-TI200 60HZ | User Manual - Page 18
    Ti200, Ti300, Ti400 Users Manual Item Table 3. Features and Controls (cont.) Description Hand Strap Manual Focus Control 2-Bay Battery Charging Base AC Power Supply with Mains Adapters 17 16 15 19 18 20 14 Ti200 IR FUSION TECHNOLOGY 21 22 23 24  Connector Cover  AC Adapter/Charger
  • Fluke FLK-TI200 60HZ | User Manual - Page 19
    capture a thermal image for possible storage to memory by the user. The manual focus system. Correct focus is important in all imaging applications. Correct focus makes sure that the infrared energy is correctly directed onto the pixels of the detector. Without correct focus, the thermal image
  • Fluke FLK-TI200 60HZ | User Manual - Page 20
    Ti200, Ti300, Ti400 Users Manual Note The user is able to use the advanced manual focus as a manual override of the LaserSharp™ the features. Table 4 is an overview of the buttons and their actions. In live Manual Mode, the arrow buttons are always active to adjust Level and Span. In general, push
  • Fluke FLK-TI200 60HZ | User Manual - Page 21
    with the three function buttons and arrow buttons, are the access for thermal image display, camera features, measurement, advanced functions, memory review, and settings for date, time, language, units, file format, and Imager information. To open the primary menu, push . The primary menu shows
  • Fluke FLK-TI200 60HZ | User Manual - Page 22
    Ti200, Ti300, Ti400 Users Manual IR-PhotoNotes™ The IR-PhotoNotes™ photo annotation system allows the user to capture and add up to five visible (digital) images of various objects, text, or other information that is related to the analysis and reporting of an infrared image. Examples of possible
  • Fluke FLK-TI200 60HZ | User Manual - Page 23
    Thermal Imagers Image Capture i Voice Annotation (Recording) To add a voice (audio) recording: 1. With an infrared image in the buffer, push  to open the EDIT IMAGE . To play back: 1. Do the steps in the Review Image Files section on page 34 to see the image on the display. 2. Push . 3. Push  to
  • Fluke FLK-TI200 60HZ | User Manual - Page 24
    , Ti300, Ti400 Users Manual Edit Captured Infrared Image Before saving a file, you can edit or modify the image. To edit: 1. With an image in the buffer, go to EDIT IMAGE > Edit Image. 2. Push / to highlight an option. 3. Push  to save the changes with the file. Save Captured Infrared Image To
  • Fluke FLK-TI200 60HZ | User Manual - Page 25
    Thermal Imagers Micro SD Memory Card Micro SD Memory Card To eject a Micro SD memory card, push in on the exposed edge of the card and Insertion and Removal hie03.eps For information about how to save data, see page 18. For information about how to view or erase a stored image, see page 34. 19
  • Fluke FLK-TI200 60HZ | User Manual - Page 26
    SmartView® software is supplied with the Imager. This software is intended for Fluke Imagers and contains features to analyze images, organize data and information, and make professional reports. SmartView® allows audio annotations and photos from the IR-PhotoNotes™ annotation system to be reviewed
  • Fluke FLK-TI200 60HZ | User Manual - Page 27
    , together with the three function buttons and arrow buttons, are access for thermal image display, camera features, memory setup, and settings for date, time, language, units, file format, and Imager information. Measurement Menu The Measurement Menu has settings for the calculation and display
  • Fluke FLK-TI200 60HZ | User Manual - Page 28
    in a menu mode, push and release  to automatically rescale the level and span range for objects in the thermal field of view. This feature operates the Imager in a semi-automatic mode if manual fine re-adjustment of level and span with the arrow buttons is not necessary. Rescaling can be done as
  • Fluke FLK-TI200 60HZ | User Manual - Page 29
    Thermal Imagers Menus Total Imager Range Span Figure 4. Level and Span Settings hie07.eps Temperature Span for Manual Operation Mode When in manual mode, the span setting contracts or expands in a selected palette in a temperature range within the total range. See Figure 4. In the live manual
  • Fluke FLK-TI200 60HZ | User Manual - Page 30
    Ti200, Ti300, Ti400 Users Manual If you set a value that is
  • Fluke FLK-TI200 60HZ | User Manual - Page 31
    infrared-transparent windows (IR windows), not all of the infrared energy emitted from the objects of interest is transmitted through the optical material in the window. If the transmission percentage of the window is known, you can adjust this percentage in the Imager or in the SmartView® software
  • Fluke FLK-TI200 60HZ | User Manual - Page 32
    Ti200, Ti300, Ti400 Users Manual Spot Temperatures The Spot Temperatures are floating HI and LO temperature indicators that move on the display as the temperature measurements of the image fluctuate. To turn on/off the hot and cold spot indicators: 1. Go to Measurement > Spot Temp. 2. Push / to
  • Fluke FLK-TI200 60HZ | User Manual - Page 33
    Thermal Imagers Menus Center Box The Center Box feature is an adjustable temperature measurement zone (box) that you can center on the infrared image. This zone (box) expands and contracts to different levels within the infrared image. The zone lets the user see an approximate maximum (MAX), average
  • Fluke FLK-TI200 60HZ | User Manual - Page 34
    , Ti300, Ti400 Users Manual Image Menu The Image menu has controls for different features used in the presentation of the infrared image on the Imager's LCD and some saved image files. Note Data saved as .is2 or .is3 formats can easily be modified within SmartView software. Still images saved in
  • Fluke FLK-TI200 60HZ | User Manual - Page 35
    (min, mid, max) Visible Note The visible image and infrared image can be customized or separated in SmartView and SmartView Mobile Software when you use the .is2 file format. To set the IR-Fusion® technology mode: 1. Go to Measurement > Image > IR-Fusion. 2. Push / to highlight an option. 3. Push
  • Fluke FLK-TI200 60HZ | User Manual - Page 36
    Ti200, Ti300, Ti400 Users Manual Color Alarms The Imager has various apparent temperature color alarms. The hightemperature color alarm shows a full visible image and only shows infrared information on objects or areas that are above the set apparent temperature alarm level. The low-temperature (or
  • Fluke FLK-TI200 60HZ | User Manual - Page 37
    must be turned on and turned off with those controls. Logo A Fluke logo shows on the display and captured images. You can choose to turn on or turn off the logo: 1. Go to Image > Logo. 2. Push / to highlight on or off. 3. Push  to set. With SmartView software you can upload a custom logo to the
  • Fluke FLK-TI200 60HZ | User Manual - Page 38
    Ti200, Ti300, Ti400 Users Manual Camera Menu The Camera menu has controls and options for secondary camera features such as auto focus, backlight level, and torch. LaserSharp™ Auto Focus System The laser pointer on the Imager is both a sighting aid and a part of the LaserSharp™ Auto Focus System. In
  • Fluke FLK-TI200 60HZ | User Manual - Page 39
    Thermal Imagers Menus Backlight The backlight level control is set to low, medium, and high. To set the backlight: 1. Go to Camera > Backlight. 2. Push / to highlight high, medium, or low. 3. Push  to set a new value. Torch The torch illuminates darker work areas. To set: 1. Go to Camera > Torch.
  • Fluke FLK-TI200 60HZ | User Manual - Page 40
    Users Manual Memory Menu The Memory Menu allows the user to review captured images, as well as audio annotations and photos from the IR-PhotoNotes™ photo annotation system in a thumbnail view format. An icon shows to indicate any additional items saved with the infrared image or IR-Fusion technology
  • Fluke FLK-TI200 60HZ | User Manual - Page 41
    Thermal Imagers Menus Settings Menu The Settings menu has adjustments for user Imager such as model number, serial number, and firmware versions SmartView software. This file format consolidates the infrared image, radiometric temperature data, visible image, voice annotation, and photos from the IR
  • Fluke FLK-TI200 60HZ | User Manual - Page 42
    can be emailed and then opened with SmartView Software. This format has the maximum versatility. Visit the Fluke website or contact Fluke to find out how to download SmartView analysis and reporting software at no charge.  Auto Off The Auto Off timer is user-defined separately for the LCD and power
  • Fluke FLK-TI200 60HZ | User Manual - Page 43
    Thermal Imagers Menus Date The date can be displayed in one of two formats: MM/DD/YY or DD/MM/YY. To set the date: 1. Go to
  • Fluke FLK-TI200 60HZ | User Manual - Page 44
    Ti400 Users Manual Language To change the display to a different language: 1. Go to Settings > Language. 2. Push  or  to highlight the setting. 3. Push  to set a new language.  Wireless Connectivity Your Imager image can be viewed with SmartView Mobile or SmartView Analysis and Reporting software
  • Fluke FLK-TI200 60HZ | User Manual - Page 45
    Thermal Imagers Menus Advanced Settings Filename Prefix The default filename starts with IR_. You have the option to change this prefix to a different 3-character name with the touch screen keyboard. Reset Filename You can reset the file number to 00001. Factory Defaults Erases all user-set
  • Fluke FLK-TI200 60HZ | User Manual - Page 46
    on the screen to view the information screen with the specific license agreement. 6. Push  to close the information screen. Streaming Video The Imager can stream live infrared and IR-Fusion™ technology video to a PC that has SmartView® software installed. To set up: 1. Attach the included USB cable
  • Fluke FLK-TI200 60HZ | User Manual - Page 47
    Thermal Imagers Remote Control (Ti400) Remote Control (Ti400) The Ti400 Imager can be remotely controlled with a PC that has SmartView software installed. To remotely control the Imager: 1. If not installed, install the latest version of SmartView software on your PC. 2. Attach the included USB
  • Fluke FLK-TI200 60HZ | User Manual - Page 48
    Ti400 Users Manual charger to the mains power outlet before the charger. • Use only Fluke approved power adapters to charge the battery. • Keep cells and battery packs not store the Imager on the charger for more than 24 hours as reduced battery life may result. • Charge the Imager for a two-
  • Fluke FLK-TI200 60HZ | User Manual - Page 49
    Thermal Imagers General Specifications General Specifications image Expand/Contract Measurement Box with MIN-AVG-MAX temp High temperature alarm Color alarms User selectable backlight setting Graphic information display (selectable) Software SmartView® full analysis and reporting software
  • Fluke FLK-TI200 60HZ | User Manual - Page 50
    Ti400 Users Manual AC Operation AC operation with included power supply: 110 - 220 Vac, 50/60 Hz, ac mains adapters included Power Save User Meets all applicable requirements in EN61326-1:Industrial FCC Part 15 Subpart C Sections 15.207, 15.209 and normal aging) Supported Languages Czech, Dutch,
  • Fluke FLK-TI200 60HZ | User Manual - Page 51
    Thermal Imagers Detailed Specifications Detailed Specifications Temperature Measurements Temperature Range (not calibrated below -10 °C) Ti200, Ti300 20 °C to +650 °C Ti400 20 °C to +1200 °C Accuracy 2 °C or 2 % (whichever is greater) at 25 °C ambient On-screen emissivity correction all models
  • Fluke FLK-TI200 60HZ | User Manual - Page 52
    Fast auto rescale in manual mode Minimum Span (in manual mode 2.0 °C (3.6 °F) Minimum span (in auto mode 3.0 °C (5.4 °F) IR-Fusion® Technology • Automatically aligned (parallax corrected) visual and infrared • Picture-In-Picture (PIP) infrared • Full screen infrared • AutoBlend mode • Full screen
  • Fluke FLK-TI200 60HZ | User Manual - Page 53
    Thermal Imagers Detailed Specifications Image and Data Storage Image Capture, Review, Save Mechanism ........ One-handed image capture, review, and save capability Storage Medium Micro SD Memory Card includes 4 GB memory card to store at least 2000 fully radiometric (.is2) IR and linked visual
  • Fluke FLK-TI200 60HZ | User Manual - Page 54
    Ti200, Ti300, Ti400 Users Manual 48
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

PN 4281773
September 2013
© 2013 Fluke Corporation. All rights reserved.
Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
Ti200, Ti300, Ti400
Thermal Imagers
Users Manual