    TiX500, TiX501, TiX520, TiX560, TiX580 Expert Series Thermal Imagers Users Manual  February 2015 Rev. 2, 4/19 (English) © 2015-2019 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of
  • Fluke TIX501-60HZ | Product Manual - Page 2
    normal use and service. The warranty period is two years and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized
  • Fluke TIX501-60HZ | Product Manual - Page 3
    Table of Contents Title Page Introduction 1 How to Contact Fluke 1 Safety Information 2 Product Familiarization 5 Features 5 Controls 7 Touch Screen 10 Control Panel 11 Basic Operation 11 Turn On and Off the Imager 11 Focus 12 Capture Image 12 Save Image 12 Menus 13 Measurement Menu
  • Fluke TIX501-60HZ | Product Manual - Page 4
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual Delete Image 36 Settings Menu 37 File Format 38 Date 39 Time 39 SmartView Software 39 Download SmartView Software 40 Download Firmware 40 Enable the
  • Fluke TIX501-60HZ | Product Manual - Page 5
    (the Product or Imager) are handheld, infrared imaging cameras for use in many applications. These applications include equipment troubleshooting, preventive and predictive maintenance, building diagnostics, and research and development. The Imager displays thermal images on a high-visibility
  • Fluke TIX501-60HZ | Product Manual - Page 6
    , TiX501, TiX520, TiX560, TiX580 Users Manual Safety Information A Warning identifies hazardous conditions and the Product: • Read all safety information before you use the Product. • Carefully read all instructions. • Do not alter the Product and use only as specified, or the protection supplied by
  • Fluke TIX501-60HZ | Product Manual - Page 7
    Expert Series Thermal Imagers • Use only Fluke approved power adapters to charge the battery. • Keep cells and battery packs clean and dry. Clean dirty connectors with a dry, clean cloth. • Batteries contain hazardous chemicals that can cause burns or explode. If exposure to chemicals occurs, clean
  • Fluke TIX501-60HZ | Product Manual - Page 8
    down or warm up) before you resume operation. Table 1 is a list of symbols that can be used on the Imager or in this manual. Table 1. Symbols Symbol Description  Consult user documentation. W WARNING. RISK OF DANGER. X WARNING. HAZARDOUS VOLTAGE. Risk of electric shock. * WARNING. LASER
  • Fluke TIX501-60HZ | Product Manual - Page 9
    materials handler per local regulations. Contact your authorized Fluke Service Center for recycling information. This product complies with and optical power: λ = xxxnm, x.xxmW. Product Familiarization The manual explains features for multiple models. Because models have different features, not
  • Fluke TIX501-60HZ | Product Manual - Page 10
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual Table 2. Features Feature TiX500 TiX501 Digital Zoom 2X   4X  8X IR-Fusion Technology Visible   Picture-in-Picture (PIP)   Full screen IR Autoblend (Preset percentage selection) 
  • Fluke TIX501-60HZ | Product Manual - Page 11
    Controls Table 3 shows the connections of the Imager. Table 3. Connections Expert Series Thermal Imagers 1 2 3 5 7 6 4 Item    D Description Lithium-ion Smart Battery Smart Battery Port Micro SD Memory Card Slot Tripod Mount Item E F G Description Anchor for Neck Strap 2-Bay Battery
  • Fluke TIX501-60HZ | Product Manual - Page 12
    Table 4 shows the front of the Product. Table 4. Front 3 4 5 2 TiX520 THERMAL IMAGER 1 6 12 11 10 9 8 7 Item    D E F Description Infrared Camera Lens Manual Focus Control Laser Pointer/Distance Finder Visual Light Camera Lens Laser Distance Finder Button Image Capture Button Item
  • Fluke TIX501-60HZ | Product Manual - Page 13
    Table 5 shows the back of the Product. Table 5. Back 1 Expert Series Thermal Imagers 2 Item  Description LCD Touch Screen (display) Item  Description Control Panel 9 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TIX501-60HZ | Product Manual - Page 14
    menu, double tap on the display to capture an image. Table 6. Touch Targets 1 2 3 6 5 Item    Description Opens the Temperature Unit menu Toggles Manual/Auto Level and Span Opens the Palette menu 4 Item D E F Description Opens the Measurement menu Opens the Date menu Opens the Time menu 10
  • Fluke TIX501-60HZ | Product Manual - Page 15
    to automatically rescale the level and span for objects in the thermal field of view. Use to operate the Imager in a semi-automatic mode if manual fine adjustment of level and span is not necessary. Basic Operation Turn On and Off the Imager Before you use the Imager for the first
  • Fluke TIX501-60HZ | Product Manual - Page 16
    infrared images are frequently unusable or of little value. To focus with the advanced manual focus system, rotate the Manual Focus Control until the inspection object is in proper focus. Use the advanced manual focus system as an override to the LaserSharp Auto Focus System. See LaserSharp Auto
  • Fluke TIX501-60HZ | Product Manual - Page 17
    Expert Series Thermal Imagers Menus Use the menus to change and view settings. To change settings: 1. Push / to select an option. 2. Push  to set the option. The primary, secondary, and option menus close 10 seconds after the last push of a function button. The option selection menu stays open
  • Fluke TIX501-60HZ | Product Manual - Page 18
    from one of the preset measurement ranges or to a fully automatic range. Set Level/Span Auto Manual Set Level/Span Sets the Level/Span to adjust automatically or manually. With Level/Span set to Manual, changes the Level/Span. See Level/Span. Line Temp Turns on/off the Line Temp
  • Fluke TIX501-60HZ | Product Manual - Page 19
    Expert Series Thermal Imagers Option Menu Transmission Spot Temp Spot Markers Spot Box Table 9. Measurement Menu (cont.) Option Description Changes the transmission percentage of the infraredtransparent window (IR window). When you do infrared inspections through IR windows, not all
  • Fluke TIX501-60HZ | Product Manual - Page 20
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual Level/Span Level and Span are values within Range of the Imager is set to one the preset measurement ranges and Level/Span is set to Manual, the level setting moves the thermal span up or down within the total temperature range. 16 MyFlukeStore
  • Fluke TIX501-60HZ | Product Manual - Page 21
    See Detailed Specifications for more information about the minimum span. Note The Imager always powers up in the same Level/Span mode, Auto or Manual, as when the Imager was powered down. Emissivity Adjustment All objects radiate infrared energy. The actual surface temperature and emissivity of the
  • Fluke TIX501-60HZ | Product Manual - Page 22
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual Note Surfaces with an emissivity of
  • Fluke TIX501-60HZ | Product Manual - Page 23
    Expert Series Thermal Imagers To set the size of the Spot Box when Spot Box is set to On: 1. Select Measurement > Spot Box > Set Size. 2. Push: •  to decrease the vertical size of the Spot Box. •  to increase the vertical size of the Spot Box.  • to decrease the horizontal size of the Spot Box.
  • Fluke TIX501-60HZ | Product Manual - Page 24
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual Image Menu Table 11 lists the options in The Imager automatically captures a visible image with every infrared image to show where a potential problem might be. Note The visible image and infrared image can be customized or separated in SmartView
  • Fluke TIX501-60HZ | Product Manual - Page 25
    Expert Series Thermal Imagers Option Menu Color Alarm Table 11. Image Menu (cont.) Option Description High Alarm OFF Turns on/off the high-temperature color alarm. The hightemperature color alarm shows a full visible image and only shows infrared information on objects or areas that are above
  • Fluke TIX501-60HZ | Product Manual - Page 26
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual Option Menu Display Image Enhancement Logo Distance Table 11. Image Menu (cont.) Option Description Sets which graphics to view on the display. Note Features
  • Fluke TIX501-60HZ | Product Manual - Page 27
    Expert Series Thermal Imagers Image Enhancement Use the Image Enhancement menu to activate the advanced features of the Imager. Activate either MultiSharp Focus or SuperResolution individually. Use Filter Mode with either MultiSharp Focus or SuperResolution. Table 12 lists the options in the Image
  • Fluke TIX501-60HZ | Product Manual - Page 28
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual MultiSharp Focus MultiSharp Focus captures several images focused on multiple targets does not capture a clear image, use LaserSharp Auto Focus or Advanced manual focus. 24 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TIX501-60HZ | Product Manual - Page 29
    Expert Series Thermal Imagers SuperResolution SuperResolution uses a sensor to capture micro movements to create an image with double the resolution. See Detailed Specifications for the resolution available based on the model of the Imager. To use: 1. Capture an image. 2. Hold the Imager still for
  • Fluke TIX501-60HZ | Product Manual - Page 30
    Turns on LaserSharp Autofocus to automatically focus on a target. See LaserSharp Auto Focus System. Turns off LaserSharp Autofocus to use the Advanced manual focus. See LaserSharp Auto Focus System. Select to set the brightness level of the display. Turns on/off the built in flashlight. Select
  • Fluke TIX501-60HZ | Product Manual - Page 31
    . Some combinations create larger file sizes that take longer to capture and save and create a higher minimum interval compared to others. Image Count Manual Trigger Temp Trigger Set Temp Trigger Bluetooth WiFi Hotspot WiFi Network Sets a number of images to capture. Or, select Maximum Memory to
  • Fluke TIX501-60HZ | Product Manual - Page 32
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual LaserSharp Auto Focus System The Laser Pointer/Distance Finder on the Imager is both a sighting aid and a part of the LaserSharp Auto Focus System. W* Warning
  • Fluke TIX501-60HZ | Product Manual - Page 33
    Expert Series Thermal Imagers Video The video controls include stop, rewind, fast forward, and pause/play functions. The thermal scene and complexity of the recorded data affects the amount of time available to record a video. Note A Bluetooth headset is required and the radio must be enabled to
  • Fluke TIX501-60HZ | Product Manual - Page 34
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual Wireless Connectivity The Imager has several wireless connectivity options. Before the first use of the wireless feature, enable the radio. See Enable the Radio. Bluetooth
  • Fluke TIX501-60HZ | Product Manual - Page 35
    Expert Series Thermal Imagers 6. Push  to go back. 7. Push  to use the Imager. WiFi Network Use the WiFi Network setting to connect the Imager to a WiFi network and to sign into your Fluke Connect account on the Imager. When WiFi Network is on,  shows in the upper left corner of the display. To
  • Fluke TIX501-60HZ | Product Manual - Page 36
    TiX520, TiX560, TiX580 Users Manual Fluke Connect Wireless System The Imager supports the Fluke Connect Wireless System the phone app. Fluke Connect Tools Use the Imager to wirelessly connect to Fluke-Connect-supported tools to: • View the live measurement of each tool. • Capture the measurement of
  • Fluke TIX501-60HZ | Product Manual - Page 37
    Expert Series Thermal Imagers To discover a Fluke Connect-supported tool: 1. Turn on each wireless tool and make sure the wireless feature is enabled. See the documentation of each tool for more information about how
  • Fluke TIX501-60HZ | Product Manual - Page 38
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual Review Image To review an image: 1. Open the Memory menu. 2. Select the preview image of the file for review. 3. Push  to review the file. Edit
  • Fluke TIX501-60HZ | Product Manual - Page 39
    Expert Series Thermal Imagers Audio Audio (voice) annotation is only available in the .is2 file format. The audio is stored with the image so you do not need to collate multiple files later. Note A Bluetooth headset is required and the radio must be enabled to record audio files. This feature may
  • Fluke TIX501-60HZ | Product Manual - Page 40
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual Text Notes Text annotation is only available in the .is2 file format. Text notes are stored with the image so you do not need to
  • Fluke TIX501-60HZ | Product Manual - Page 41
    Expert Series Thermal Imagers Settings Menu Table 14 lists the options in the Settings menu. Table 14. Settings Menu Option Menu File Format Units Auto Off Date Time Language Localization Image Storage Advanced Option Description Image Format Video Format Sets the file type to save images and
  • Fluke TIX501-60HZ | Product Manual - Page 42
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual File Format Select from a list of image and video file formats based on how the end file will be used. Table 15 lists the image
  • Fluke TIX501-60HZ | Product Manual - Page 43
    Expert Series Thermal Imagers Date The date shows as: MM/DD/YY or DD/MM/YY. To set the date: 1. Select Settings > Date. 2. Select MM/DD/YY or DD/MM/YY. 3. Push  to set the new format. 4. Select Set Date. 5. Push  to open the Set Date menu.   6. Push / to select Day, Month, or Year. 7. Push /
  • Fluke TIX501-60HZ | Product Manual - Page 44
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual Download SmartView Software 1. On the website, follow the instructions to download the software to the PC. 2. On the PC, follow the instructions to install SmartView software. (Administrator privileges are required for the installation.) 3.
  • Fluke TIX501-60HZ | Product Manual - Page 45
    Expert Series Thermal Imagers 3. On the website: a. Select a language from the drop down box. b. Enter your information and the serial number from the display on the Imager. The serial number is case sensitive. c. Click on Submit. If the radio is authorized in your country, an authorization code
  • Fluke TIX501-60HZ | Product Manual - Page 46
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual 3. Connect the USB A connector end of the cable into your PC and the USB Micro B connector end into the Imager. Note Some Imagers have both A
  • Fluke TIX501-60HZ | Product Manual - Page 47
    Expert Series Thermal Imagers Remote Control of Imager Use SmartView software on a PC or the Fluke Connect app on a mobile device to remotely control the Imager. To remotely control the Imager with a PC: 1. Turn on Remote Display. See Stream Live to a PC. 2. In SmartView software, select SmartView (
  • Fluke TIX501-60HZ | Product Manual - Page 48
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual Accessories Table 17 is a list of the accessories available for the Imager. Table 17. Accessories Model Description FLK-TI-SBP4 Smart Battery Pack FLK-TI-
  • Fluke TIX501-60HZ | Product Manual - Page 49
    Expert Series Thermal Imagers Optional Lenses Use optional telephoto and wide-angle lenses for more applications of infrared inspection work. To install a lens, align the dot on the lens with the dot on the Product. See Figure 1. Figure 1. Optional Lens Installation 45 MyFlukeStore Shop for Fluke
  • Fluke TIX501-60HZ | Product Manual - Page 50
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual Neck Strap Use the neck strap to carry the Imager for an extended period of time. See Figure 2. Figure 2. Adjustable Neck Strap Maintenance The Imager
  • Fluke TIX501-60HZ | Product Manual - Page 51
    Expert Series Thermal Imagers Clean the Product Clean the case with a damp cloth and a weak soap solution. Do not use abrasives, isopropyl alcohol, or solvents to clean the case or lens/window. Battery Care W Warning To prevent personal injury and for safe operation of the Product: • Do not put
  • Fluke TIX501-60HZ | Product Manual - Page 52
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual Charge Batteries Before you use the Imager for the first time, charge the battery for a minimum of two and onehalf hours. The battery status shows
  • Fluke TIX501-60HZ | Product Manual - Page 53
    Do not incinerate the Product and/or battery. Go to Fluke's website for recycling information. Radio Frequency Data See Table 14 for instructions on how to access digital copies of the Certificate IDs on the Imager. General Specifications Temperature Operating Storage Relative Humidity Altitude
  • Fluke TIX501-60HZ | Product Manual - Page 54
    TiX500, TiX501, TiX520, TiX560, TiX580 Users Manual TiX500 TiX501 TiX520 TiX560 TiX580 Power Batteries 2 Lithium-ion Rating IP54 Calibration Cycle 2 years (assumes normal operation and normal aging) Supported Languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian,
  • Fluke TIX501-60HZ | Product Manual - Page 55
    Expert Series Thermal Imagers Detailed Specifications TiX500 TiX501 TiX520 TiX560 TiX580 Temperature Measurements Temperature Range (not -20 °C to calibrated below -10 °C) +650 °C -20 °C to +650 °C -20 °C to +850 °C -20 °C to +1200 °C -20 °C to +1000 °C Accuracy ±2 °C or 2 % (whichever
  • Fluke TIX501-60HZ | Product Manual - Page 56
    Metal Ultra, Ironbow Ultra Level and Span Smooth Auto-Scaling and Manual scaling of level and span Fast auto toggle between manual and auto modes Fast auto-rescale in manual mode Minimum Span (in manual mode) 2.0 °C (3.6 °F) Minimum Span (in auto mode) 3.0 °C (5.4 °F) Image Capture and Data
  • Fluke TIX501-60HZ | Product Manual - Page 57
    Speed 24 fps (9 fps for imagers with 9 Hz refresh rate.) Radiometric Viewable on Imager and with SmartView software in proprietary .is3 format. Supports voice recording in addition to captured video. Recording Speed 20 fps (9 fps for imagers with 9 Hz refresh rate.) IR-PhotoNotes Annotation
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57

TiX500, TiX501, TiX520
,
TiX560, TiX580
Expert Series Thermal Imagers
Users Manual
February 2015 Rev. 2, 4/19
(English)
© 2015-2019 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
Shop for Fluke products online at:
1.888.610.7664
www.
MyFlukeStore
.com