Frigidaire FFHP183WS2 Installation Instructions

Frigidaire FFHP183WS2 Manual

Frigidaire FFHP183WS2 manual content summary:

  • Frigidaire FFHP183WS2 | Installation Instructions - Page 1
    All about the Installation of your Split Type Room Air Conditioner Refer to Page 2 for table of contents. 2020323B2335 (June 2009) www.frigidaire.com USA 1-866-942-1567 www.frigidaire.ca Canada 1-866-942-1567
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 2
    and no worries Thank you for choosing Frigidaire. This manual contains all of the information required to guarantee your safety and the appropriate use of your air conditioner. Please read all of the instructions before using the air conditioner and keep this manual for future reference. We know you
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 3
    Contents 01. Welcome 01 02. Environmental advices 01 03. Contents 02 04. Safety precautions 03 05. Installation: 5.1 Choosing the installation site 04 5.2 Parts list 06 5.3 Indoor unit installation 08 5.4 Outdoor unit installation 12 5.5 Refrigerant piping connection 14 5.6 Electrical work
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 4
    and call an authorized Frigidaire servicer. 8. Do not operate the air conditioner with wet hands. 9. Do not drink any water or condensation that is drained from the air conditioner. 10.Provide occasional ventilation during use. Do not direct airflow at fire places or other heat
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 5
    installation site Installation Warnings 1. Carefully read the installation manual before beginning. 2. Follow each step as shown. all safety notices. Precautions for Installation Installation at the following sites may cause problems. If you must inevitably install the unit at one of these sites,
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 6
    unit must be installed at a convenient site that is not exposed to strong winds. The site should be dry and well ventilated. 2. The site must support the weight of the outdoor unit and allow for vertical installation. 3. The site must be kept away from flammable gases. 4. The site must provide
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 7
    wrench (4mm) 10. Gas-leak detector 11. Vacuum pump 12. Gauge manifold 13. Users manual 14. Thermometer 15. Multimeter 16. Pipe cutter 17. 13 Connection power cable 14 Drain connector (Heat Pump model only) Not supplied 1 15 Drain plug (Heat Pump model only) (Optional) 2-3 16 Thermal
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 8
    30cm above above 30cm 16 above 2m 50cm above Space to the wall Air outlet side 12 15 14 NOTE All the pictures in this manual are for explanation purposes only. The actual shape of the indoor unit you purchased may be slight different on front panel and display window.The
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 9
    Indoor unit installation Wall mounting brackets and dimensions B B 4.21" 4.21" B Indoor unit outline 6" or more from the wall Refrigerant pipe hole (right) Ø 2.56" 6" or more from the ceiling Wall mounting bracket 3.39" A 3.39" ”%WX V 6" or more from the wall Refrigerant pipe hole (
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 10
    on the bracket, as shown in figure 1.3. 2. In the case of tiled, concrete or similar walls, create 13/64" diameter holes. Place anchor supports for the appropriate assembly screws. 3. Install the wall mounting bracket to the wall with eight A type screws. 4. At all times securing to the wall
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 11
    Connective pipe and drainage installation Connective pipe 1. For the left-hand and right-hand piping, remove the pipe cover from the side panel. The pipe cover can be kept as it may be used when relocating the air conditioner to any other place. 2. For the rear-right-hand and rearleft-hand piping,
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 12
    !! 1. Connect the indoor unit first, then the outdoor unit. 2. Be careful not to let the drain hose slack. 3. Both of the auxiliary piping should be heat insulated. 4. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side may cause drain pan
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 13
    Outdoor unit installation 1. Install the outdoor part of the unit on a flat surface to avoid excess noise and vibration. A condenser pad is recommended. 2. Direct the air vent toward an area without obstacles. 3. Install the unit at the site where it is exposed to as little wind as possible,
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 14
    Condensate drainage of outdoor unit (cooling only excluded) The condensate and defrosting water produced during heating in the outdoor unit can be properly discharged by drainage pipe. Installation method: Insert the drain connection into one of the holes of the chassis
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 15
    Refrigerant piping connection Unit comes with 25' tubing bundle. It is not recommended to cut. If too long, loop for excess. Note: Keep original bend so not kinking of the tube occurs. Flaring work Main cause for refrigerant leakage is due to defect in the flaring work. Carry out correct
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 16
    4. Flaring work. Firmly hold copper pipe in a die in the dimension shown in the table below. OUTER DIAMETER (inch) 1/4 3/8 1/2 5/8 A (inch) Max. Min. 0.051 0.063 0.071 0.095 0.028 0.039 0.039 0.087 Connection Adjustment 1. Align the pipes to be connected. 2. Screw the flare nut with your
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 17
    about the power supply, the technicians should refuse to install the air conditioner and explain to the client until the problem is solved. 2. Power voltage should meet the requirements in table 2.1. 3. Over current protection and circuit disconnect should meet the requirements in table 2.1 and
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 18
    Connect the cable to the indoor unit 1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible type cord. 3. Lift the indoor unit panel up, remove the
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 19
    Connect the cable to the outdoor unit 1. Remove the electrical control board cover from the outdoor unit by loosening the screw. 2. Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units. The connective
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 20
    circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2. The rises. 2. Operating current rises. 3. Cooling or heating (only for models with heating function) efficiency drops. 4. Moisture in the refrigerant
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 21
    Max height length (A) difference (B) Air purging 25'~49' 16' Use vacuum pump. 25'~66' 33' Use vacuum pump. 25'~82' 33' Use vacuum pump. 25'~82' 33' Use vacuum pump. 22000 22000 28000 33600 Cooling Only Heat Pump Heat Pump Heat Pump 25'~82' 25'~82' 25'~98' 25'~98' 33' Use vacuum
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 22
    25'~66' (x=1, 2, 3) 197' (H1=L1+L2+...+Lx, x›3) 50' Use vacuum pump. R410a: 0.22ozs/ft (Pipe length-82') 34400 25'~82' (x=1, 2, 3, 4, 5) 246 ' (H1=L1+L2+...+Lx, x›5) 50' Use vacuum pump. R410a: 0.22ozs/ft (Pipe length-131') Outdoor unit Lx H1 L1 L2 L3 L4
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 23
    When using the vacuum pump For method of using a manifold valve, refer to its operation manual. 1. Completely tighten the flare the Low Side handle of the manifold valve and stop the operation of the vacuum pump. 6. Turn the stem of the packed valve B about 45o counterclockwise for 6~7 seconds
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 24
    Electrical safety Perform the electric safety check after completing installation: 1. Insulated resistance: The insulated resistance must be more than 2M. 2. Grounding work: After finishing grounding work, measure the grounding resistance by visual detection and grounding resistance tester. Make
  • Frigidaire FFHP183WS2 | Installation Instructions - Page 25
    (Only for models with heating function), AUTO and FAN to check if all the functions work well. 3. When the ambient temperature is too low(lower than 63 oF), the unit cannot be controlled by the remote controller to run in cooling mode, manual operation can be taken. Manual operation is used only
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

Refer to Page 2 for table of contents.
www.frigidaire.com
USA 1-866-942-1567
www.frigidaire.ca
Canada 1-866-942-1567
2020323B2335 (June 2009)
All about the
Installation
of your
Split Type Room Air Conditioner