Frigidaire FFRE2533S2 Installation Instructions

Frigidaire FFRE2533S2 Manual

Frigidaire FFRE2533S2 manual content summary:

  • Frigidaire FFRE2533S2 | Installation Instructions - Page 1
    ″ 28″ Max. Window Width: 42″ 40-1/2″ 1. Check window opening size: the mounting parts furnished with this air conditioner are made to install in a wooden sill double-hung window. The standard parts are for window dimensions listed above. Open sash to a minimum of 19″ (483mm). (FIG.1) 2. Check
  • Frigidaire FFRE2533S2 | Installation Instructions - Page 2
    Guide for serial plate location.) Power cord is 48″ long. Be sure you have an outlet near. All models have a 3-prong service plug to provide proper service change. 6. Carefully unpack air conditioner Remove all packing material. Protect support brackets) Foam gasket Window sash seal Window support
  • Frigidaire FFRE2533S2 | Installation Instructions - Page 3
    Installation Instructions Window Mounting 1 Remove Air Conditioner from Cabinet NOTE: Remove any packaging panel will also pull free from vent control lever. Depress latch on electronics plug (on some models) to disconnect. 6. Remove Front Panel from unit (see Fig. 4). FIG.3 FIG.4 base
  • Frigidaire FFRE2533S2 | Installation Instructions - Page 4
    window filler panel leg Installation Instructions WINDOW FILLER PANEL FIG.10 TOP VIEW AIR CONDITIONER CABINET PLASTIC FRAME Bottom window given the sill width distance. Thread the bolts into the slots of the support brackets. Tighten lock washer nuts onto bolts. 4. Adjust height of sill angle
  • Frigidaire FFRE2533S2 | Installation Instructions - Page 5
    Installation Instructions 6 Extend Window Filler Panels and attach to top angle rail: into place on cabinet. Insert 4 previously removed screws through front panel and into air conditioner. 5. Insert air conditioner filter. Reinstall the front grille by hooking bottom tabs into slots on Front Panel
  • Frigidaire FFRE2533S2 | Installation Instructions - Page 6
    (FIG. 24). 4. Repeat these instructions for the other side. FIG. 22 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Measure the inner width of the side curtain or FIG. 23 11 In order to minimize air leaks between the room air conditioner and the window opening, suitable
  • Frigidaire FFRE2533S2 | Installation Instructions - Page 7
    air conditioner will be installed (by sounding wall, or by magnetically finding nails). 2. Cut out a hole on each side of center stud. 3. Measure between inside edges of every other stud as shown in FIG.1. Carefully measure and cut an opening with the following dimensions depending on your model
  • Frigidaire FFRE2533S2 | Installation Instructions - Page 8
    Instructions 4. Build a wooden frame with the INSIDE dimensions of your model 3 Prepare and Install Cabinet 1. Slide air conditioner from cabinet; refer back to Step 1 Side Louvers Refer to Step 5 of Window Mounting for assembly of support brackets. Nail a wooden strip to the outside wall for the
  • Frigidaire FFRE2533S2 | Installation Instructions - Page 9
    Installation Instructions FIG.7 FIG.8 Support bracket Sill angle bracket Wooden strip 6. Install air conditioner into cabinet by of cabinet, and all sides of wood sleeve to the opening. NOTE: See Step 5, Item 4 of Window Mounting Instructions for bottom rail seal location. Masonry Construction
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

Preliminary instructions:
READ BEFORE INSTALLING UNIT
1
1.
Check window opening size:
the mounting parts
furnished with this air conditioner are made to install in
a wooden sill double-hung window. The standard parts
are for window dimensions listed above. Open sash to
a minimum of 19″ (483mm). (FIG.1)
Heavy duty
NOTE: DO NOT USE ANY SCREWS OTHER THAN THOSE SPECIFIED HERE.
Do the following before starting to install unit. See illustrations below.
Check dimensions of your unit to determine model type:
Medium
Unit Height:
Unit Width:
Min. Window Opening:
Min. Window Width:
Max. Window Width:
18-5/8″
17-5/8″
26-1/2″
23-5/8″
19-1/2″
18-1/2″
31″
28″
42″
40-1/2″
2.
Check condition of window:
all wood parts of window
must be in good shape and able to firmly hold the needed
screws. If not, make repairs before installing unit.
3.
Check your storm windows:
If your storm window
frame does not allow the clearance required, correct by
adding a piece of wood as shown (FIG.2), or by removing
storm window while room air conditioner is being installed.
15,000~18,500 BTU
22,000~28,500 BTU
sash
1/2″ min
storm window frame or
other obstruction
FIG.1
19″ min
inner sill
outer sill
Capacity:
FIG.2
sash
1/2″ min
storm window frame or
other obstruction
19″ min
board thickness as
required, along entire inner
window sill; fasten to inner
sill with two nails or screws.
1-1/2″ min
inner sill
outer sill
16120300A04662
For Medium
(15,000-18,500 BTU)
+ Heavy duty
(22,000-28,500 BTU)
Air Conditioner
Pay attention to danger and safety notices.
To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may
be exposed:
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install
the unit. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils. To
prevent injury or strain, use proper lifting and carrying techniques when moving unit.
Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit overan extended
period of time.
Handle air conditioner with care.
Make sure air conditioner does not fall during installation.
If a new electrical outlet is required, have the outlet installed by a qualified electrician before installing unit.
Carefully read the installation manual before beginning.
Follow each step as shown.
Observe all local, state, and national electrical codes and by qualified, licensed, authorized personnel only.
INSTALLATION WARNINGS AND CAUTION
window sash seal
safety lock and
1/2″ long hex
head screw
top angle
foam gasket
washer head
locking screw
frame
assembly
(left)
side retainer
bottom rail
seal to unit
frame
assembly
(right)
1/2″
long
screws and
locknuts
locknut 3/4″
long flat
head bolt
sill angle
bracket
window
support bracket
insulation
panel
Installation Instructions