Frigidaire FFRS1022RE Installation Instructions

Frigidaire FFRS1022RE Manual

Frigidaire FFRS1022RE manual content summary:

  • Frigidaire FFRS1022RE | Installation Instructions - Page 1
    Instructions READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual inspect location where air conditioner will be installed. Be sure it will support the weight of the unit overan extended period of time. Handle air
  • Frigidaire FFRS1022RE | Installation Instructions - Page 2
    Installation Instructions Receptacle Wiring: Receptacle wiring should be a minimum of 14 techniques. Inspect the condition of the window where unit will be installed. Be sure it will support the weight of the unit. This appliance must be installed according to all applicable codes and ordinances
  • Frigidaire FFRS1022RE | Installation Instructions - Page 3
    Installation Instructions 1 Make sure you have all the necessary parts. Installation kit contents (FIG.3): No. Hardware 1 Platform 2 Support brace 3 Adjustment bolt 4 Hex flange nut - 1/4 5 Track seal 6 Side channel seal 7 Window sash seal 8 Safety bracket 9 10 Qty. No. Hardware 1
  • Frigidaire FFRS1022RE | Installation Instructions - Page 4
    bracket on the window track before you install the platform. Follow the instructions below to do that. 1. Place the support bracket on the window sill as shown (FIG.8C). Using the holes in the support bracket as a guide, mark and drill two 1/8" diameter holes. 2. Follow Step 7 to applly the track
  • Frigidaire FFRS1022RE | Installation Instructions - Page 5
    Installation Instructions 9 Place platform assembly, with platform tab against inside of window place platform assembly, with platform tab against insidh edge of the support bracket, and use two 3/8" screw (item 17) to attach it to support bracket as shown (FIG.11B). 10 Adjust platform assembly so
  • Frigidaire FFRS1022RE | Installation Instructions - Page 6
    Instructions pivots in the feature. To avoid crank handle and window clearance problems, the unit can be installed in a stationary sash section. However location that will create a 45 degree angle between the platform and support brace. Try the assembly in the window to determine if the platform
  • Frigidaire FFRS1022RE | Installation Instructions - Page 7
    Installation Instructions NOTE: If you are planning to use a siding-protection board (see Step 29) on the outside of your house, hold the board in place when
  • Frigidaire FFRS1022RE | Installation Instructions - Page 8
    Installation Instructions 34 Cut side channel seal into 2 equal lengths. Remove the protective backing and apply it to the rear side of the cabinet side channels, starting
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

READ BEFORE INSTALLING UNIT
For Slider Casement Air Conditioners
1
Installation Instructions
NOTE:
These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or
installation in a metal CASEMENT window. Modification may be necessary when installing in windows made
differently than those shown in these instructions.
WARNING:
Electrical ground is required on this appliance.
Electrical Shock and Personal Injury Hazard
DO NOT ground to a gas line.
If cold water pipe is interrupted by plastic, non-metallic gaskets, or other insulating materials, DO NOT use for
grounding.
Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded.
DO NOT modify power supply cord plug. If it does not fit outlet, have a proper outlet installed by a qualified
electrician.
DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral, or grounding circuit could result in
an electrical shock.
DO NOT use an extension cord with this appliance.
Failure to follow these instructions could result in electrical shock, serious injury, or death.
Meeting Electrical Requirements
OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES. DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD GROUNDING PRONG.
NOTE:
If codes permit, and a separate grounding wire is used, it is recommended that a qualified electrician determine
that the grounding path is adequate and not interrupted by plastic, non-metallic gaskets, or other insulating
materials.
2020213A1659
Pay attention to danger and safety notices.
To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may
be exposed:
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install
the unit. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils. To
prevent injury or strain, use proper lifting and carrying techniques when moving unit.
Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit overan extended
period of time.
Handle air conditioner with care.
Make sure air conditioner does not fall during installation.
Carefully read the installation manual before beginning.
Follow each step as shown.
Observe all local, state, and national electrical codes and by qualified, licensed, authorized personnel only.
INSTALLATION WARNINGS AND CAUTION