Frigidaire FRA25EST2 Installation Instructions (All Languages)

Frigidaire FRA25EST2 Manual

Frigidaire FRA25EST2 manual content summary:

  • Frigidaire FRA25EST2 | Installation Instructions (All Languages) - Page 1
    screw Unit Height: Ǝ Ǝ foam gasket top angle Unit Width: Min. Window Opening: washer head locking screw Min. Window Width: Ǝ Max. Window Width: Ǝ frame assembly (left) 1. Check window opening size: the mounting parts furnished with this air conditioner are
  • Frigidaire FRA25EST2 | Installation Instructions (All Languages) - Page 2
    air flow. 5. Check the available electrical service Power supply must be the same as that shown on the unit serial nameplate. (See Use & Care Guide 6. Carefully unpack air conditioner 5HPRYHDOOSDFNLQJ LQVLGH )RDPJDVNHW window support brackets) :LQGRZVXSSRUW HEAVY DUTY (22,000~28,500BTU) FIG
  • Frigidaire FRA25EST2 | Installation Instructions (All Languages) - Page 3
    models (22,000~28,500BTU) come with internal shipping packaging. THIS PACKAGING AND PLASTIC TIES MUST BE REMOVED PRIOR TO INSTALLING THE AIR CONDITIONER 3 Assemble Window Filler Panels 1. Place cabinet on floor, a bench, or a table. 2. Slide "I" section at end of window filler panel into side
  • Frigidaire FRA25EST2 | Installation Instructions (All Languages) - Page 4
    Instructions :,1'2:),//(5 P$1(/ ),* TOP9,(: $,5&21',7,21(5 1(7 3/$67,& )5$0( %RWWRPZLQGRZ ILOOHUSDQHOOHJ 6,'(5(TAINER 4 Place Cabinet in Window "I´6(&7,21 /2&.,1* 6&5(:+2/( WINDOW VLOO SDQKHDG3KLOOLSVVFUHZV 5 Install Support Bracket %6DIHW\/RFN 2QO\IRU9LQO\&ODG
  • Frigidaire FRA25EST2 | Installation Instructions (All Languages) - Page 5
    -hand Window Filler Panel Top Leg C. Window channel off protective backing, and use to plug any gaps. See Fig. 18B. A weather seals A URXQGKHDG screw FIG.19 FIG.20 FIG. 21 WINDOW SASH SEAL SAFETY LOCK ƎORQJ hex-head screws Vent control correct location 9 Install Air Conditioner into
  • Frigidaire FRA25EST2 | Installation Instructions (All Languages) - Page 6
    Instructions Thru-The-Wall Installation NOTE: &RQVXOWORFDOEXLOGLQJFRGHVSULRUWRLQVWDOODWLRQRUDTXDOLILHGFDUSHQWHU 1 Select Wall Location This air conditioner slides out from its cabinet, so that it can be installed through an outside wall \ 22,000~28,500BTU 15,000~18,500BTU ,QVLGH
  • Frigidaire FRA25EST2 | Installation Instructions (All Languages) - Page 7
    can enter area between inner and outer wall. NAIL SPACERS TO STUDS FIG.3 FIG.4 LEVEL CAULK AS REQUIRED ALUMINUM FLASHING OVER BOTTOM OF FRAME 29(5Ǝ 3 Prepare and Install Cabinet 1. Slide air conditioner from cabinet; refer back to Step 1 of Window Mounting. 2. Place cabinet into opening
  • Frigidaire FRA25EST2 | Installation Instructions (All Languages) - Page 8
    Installation Instructions FIG.7 FIG.8 Support bracket Sill angle bracket Wooden strip 6. Install air conditioner into cabinet by following all steps in Step 9 of Window Mounting. OPTIONAL: Caulking and installation of trim on interior wall may be done. You can buy wood from your local lumber or
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Preliminary instructions:
READ BEFORE INSTALLING UNIT
For Medium (15-18.5K) + Heavy duty (22-28.5K) Air Conditioner
1
Installation Instructions
To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp
edges that may be exposed:
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to
move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over
an extended period of time.
Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp
metal fins of front and rear coils.
Make sure air conditioner does not fall during installation.
If a new electrical outlet is required, have the outlet installed by a qualified electrician before installing unit.
1.
Check window opening size:
the mounting parts
furnished with this air conditioner are made to install in
a wooden sill double-hung window. The standard parts
are for window dimensions listed above. Open sash to
Heavy duty
NOTE: DO NOT USE ANY SCREWS OTHER THAN THOSE SPECIFIED HERE.
Do the following before starting to install unit. See illustrations below.
Check dimensions of your unit to determine model type:
Medium
Unit Height:
Unit Width:
Min. Window Opening:
Min. Window Width:
Max. Window Width:
2.
Check condition of window:
all wood parts of window
must be in good shape and able to firmly hold the needed
screws. If not, make repairs before installing unit.
3.
Check your storm windows:
If your storm window
frame does not allow the clearance required, correct by
storm window while room air conditioner is being installed.
window sash seal
safety lock and
long hex
head screw
top angle
foam gasket
washer head
locking screw
frame
assembly
(left)
side retainer
bottom rail
seal to unit
frame
assembly
(right)
long
screws and
locknuts
long flat
head bolt
sill angle
bracket
window
support bracket
sash
storm window frame or
other obstruction
FIG.1
inner sill
outer sill
Capacity:
FIG.2
sash
storm window frame or
other obstruction
board thickness as
required, along entire inner
window sill; fasten to inner
sill with two nails or screws.
inner sill