Frigidaire FRS093LS1 Installation Instructions (All Languages)
Frigidaire FRS093LS1 Manual
View all Frigidaire FRS093LS1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Frigidaire FRS093LS1 manual content summary:
- Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 1
Choosing the installation site Precautions for Installation Installation at the following sites may cause problems. If you must inevitably install the Indoor Unit 1. The unit must be installed at a site that does not obstruct the flow of air. 2. The site must support the weight of the indoor unit. - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 2
dry and well ventilated. 2. The site must support the weight of the outdoor unit and allow for vertical installation. 3. There must not be the possibility of site. 4. The unit must be installed at a site where the noise produced by its operation and air discharge does not disturb the neighbors or - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 3
Liquid side Gas side Ø1/4" (capacity < 12000 Btu's) Ø3/8" (capacity > 12000 Btu's) Ø3/8" (capacity < 9000 Btu's) Ø1/2" (capacity < 12000 Btu's) Ø5/8" (capacity > 12000 Btu's) Remote controller Self-tapping screw B # 7 X 3/4" Remote Controller holder QTY. 1 10 8 1 1 1 1 1 2 1 Indoor unit - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 4
More than 6" Indoor unit More than 5" 1 23 6 6 More than 5" Air filter 7 8 More than 2 feet More than 1 feet A 4 10 9 5 B More than 6.6 feet More than 2 feet C Outdoor unit Attention 1. This illustration is for explanation purposes only. 2. Copper - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 5
- Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 6
Btu's 10.72" 3.55" 5" or more from the wall Refrigerant pipe hole (right) Ø 2.56" < Fixing the Installation Plate 1. Install the installation create 0.2 inch diameter holes. Place anchorage supports for the appropriate assembly screws. 3. Fix the installation plate to the wall with eight A type - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 7
cover from the side panel. The pipe cover must be kept as it may be used when relocating the air conditioner to any other place. 2. For the rear-right-hand and rear-lefthand piping, install the piping as shown in the sideward figure. Bend the connective pipe to be laid at a height of - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 8
nor intertwist the power wire with any other wiring. 7. Run the drain hose sloped downward to drain out the condensed water smoothly. 13 Indoor unit installation - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 9
technique requirement in the installation bracket diagram. The installation wall should be solid brick, concrete or the same intensity construction, or action to reinforce, damping supporting should be taken. The connection between bracket and wall, bracket and the air conditioner should be firm - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 10
'x1.94'x0.94' 2.77'x2.28'x1.10' Air inlet B A Air inlet Air outlet A (inch) 1.50' 1.51' 1.80' 1.74' 1.84' B (inch) 0.82' 0.91' 0.91' 0.95' 1.10' Drain joint installation Fit the seal into the drain elbow, then insert the + Seal Drain joint Seal = Drain pipe 15 Outdoor unit installation - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 11
Refrigerant piping connection Unit comes with 16.4 feet tubing bundle. It is not recommended to cut. If too long, loop for excess. Note: Keep original bend so not kinking of the tube occurs. Flaring work Main cause for refrigerant leakage is due to defect in the flaring work. Carry out correct - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 12
a spanner and torque wrench, as shown in the following figure. Caution: Excessive twisting may break the nut, depending on the installation conditions. Indoor unit tubing OUTER DIAMETER (inch) 1/4 3/8 1/2 5/8 Flare nut Pipings TIGHTENING TORQUE (lbf.in) 139 260 434 651 ADDITIONAL TIGHTENING - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 13
Electrical work Electric safety regulations for the initial Installation 1. If there is serious safety problem about the power supply, the technicians should refuse to install the air conditioner and explain to the client until the problem is solved. 2. Power voltage should be in the range of 90%~ - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 14
touch any electrical components. Secure the cable onto the control board with the cord clamp. Electrical box cover < 12000 btu's CABLE (Heating and cooling model) "Cable A" or "Cable B" Code wire Code wire < 12000 btu's CABLE (Cooling model) Code wire 0.39" 1.57" 1.57" 0.39" 1.57" 0.39 - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 15
Terminal block of indoor unit 12 34 9000 and 12000 Btu's HEATING AND COOLING MODEL "Connector A" or "Connector B" Terminal block of indoor unit 1 2(N) 3 4 1 2(N) 3 4 or To Outdoor Unit To outdoor unit 18000 Btu's HEATING AND COOLING MODE "Connector A" Terminal block of indoor unit To outdoor - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 16
cable as illustrated in the installation diagram of indoor and outdoor units. 5. Insulate unused cords (conductors) with PVC-tape. Process them so they could not touch any electrical or metal parts. Cover Screw < 12000 btu's CABLE (Heating and cooling model) "Cable D" or "Cable E" Code wire - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 17
block of outdoor unit L NG1 2 3 4 Cord clamp To power supply To indoor unit 9000 and 12000 Btu's HEATING AND COOLING MODEL "Conector A" or "Conector B" Terminal block of outdoor unit 1 2(N) 3 4 1 2(N) 3 4 Cables board Cables board "Conector C" or "Conector D" Terminal block of outdoor - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 18
specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2. The the cable thickness is as specified in the power source specification. 7. Always install an earth leakage circuit breaker in a wet or moist area. 8. The - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 19
Air purging with vacuum pump 1. Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit. Note - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 20
pump For method of using a manifold valve, refer to its operation manual. 1. Completely tighten the flare nuts at connection point A, B, C the flare nut of the Lo valve on the gas pipe side and check if the air is entering (Operation noise of the vacuum pump changes and a compound meter indicates 0 - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 21
. Make sure the grounding resistance is less than 4 . 3. Electrical leakage check (performing during test running): During test operation after finishing installation, the serviceman can use the electric probe and multimeter to perform the electrical leakage check. Turn off the unit immediately if - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 22
COOL, HEAT(Only for models with heating function), AUTO and FAN to check if all the functions work well. 3. When the ambient temperature is too low(lower than 63oF), the unit cannot be controlled by the remote controller to run in cooling mode, manual operation can be taken. Manual operation is used - Frigidaire FRS093LS1 | Installation Instructions (All Languages) - Page 23
the aforementioned safety norms. 3. Before operating the air conditioner, ensure that the air filter is installed correctly. 4. If the unit has been °F~109°F, for the models with low temperature cooling system * only for models with heating function Attention If air conditioner is used outside of
8.
The site must allow for the easy
removal of the connector pipe and
drain hose.
9.
The unit must be installed at a site
protected from direct sunlight.
P
recautions for Installation
Installation at the following sites may cause problems. If you must inevitably install
2.
Sites with a high concentration of salinity, such as coastal areas.
3.
Sites with sulfuric gas, such as hot water springs.
4.
Sites with high frequency equipment, such as wireless equipment, welding
machines and medical installations.
5.
Sites with flammable gases or volatile material.
6.
Sites with special environmental conditions.
7.
Laundry rooms.
Indoor Unit
1.
The unit must be installed at a site
that does not obstruct the flow of
air.
2.
The site must support the weight of
the indoor unit.
3.
The site must be easily accessible
for maintenance and replacement
of the air filter.
4.
The site must allow for the
necessary space around the indoor
figure.
that the unit be installed at the
flammable gases.
Choosing the installation site
More
More
More
More
Choosing the installation site
the unit at one of these sites, please consult your local distributor beforehand:
1.
Sites with machine oil.
unit, as shown in the sideward
meter) between the unit and radio
5.
There should be at least 3 feet (1
7.
The indoor unit must be at least 7.5
feet (2.3 meters) from the ground.
6.
It must be far from fire, smoke or
center.
or television devices. It is ideal
than 6"
than 5"
than 7.5'
than 5"
Installation warnings:
Installation
1.
Carefully read the installation manual before beginning.
2.
Follow each step as shown.
3.
Observe all local, state, and national electrical codes and by qualified,
licensed, authorized personnel only.
4.
Pay attention to danger and safety notices
07