Frigidaire FRS18PYS2 Installation Instructions (All Languages)
Frigidaire FRS18PYS2 Manual
View all Frigidaire FRS18PYS2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Frigidaire FRS18PYS2 manual content summary:
- Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 1
Carefully read the installation manual before beginning. 2. Installation at the following sites may cause problems. If you must inevitably install the unit 2. The site must support the weight of the indoor unit. 3. The site must be easily accessible for maintenance and replacement of the air filter - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 2
unit must be installed at a convenient site that is not exposed to strong winds. The site should be dry and well ventilated. 2. The site must support the weight of the outdoor unit and allow for vertical installation. 3. There must not be the possibility of increased noise and vibration at the site - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 3
list NUMBER 1 2 3 4 PART NAME Installation plate Drain Joint Self-tapping scr ew A #7 X 1" Remote controller capacity < 18000 Btu = 21500 Btu's 7 Remote Controller holder 8 Self-tapping screw B #4 X 3/8" QTY. 1 1 5 10 1 1 3 2 1 2 Indoor unit 6 4 2 8 7 1 3 Outdoor unit Parts list 08 - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 4
More than 6" Indoor unit More than 6" 1 3 4 8 Air filter More than 1' A 7 6 More than 6" 5 More than 1.65' More than 1.65' 6 B More than 6.6' 2 Attention 1. This illustration is for explanation purposes only. 2. Copper tubes must be insulated independently C Outdoor unit 09 Parts list - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 5
plate 3.39" A 3.39" - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 6
plate =21500 Btu's (A:39.69" B:12.40") 6" or more from the wall 1.97'' Refrigerant pipe hole (right) Ø 2.56" 4.88'' Fixing the Installation Plate 1. Install the installation plate horizontally over the structural parts on the wall using the spaces indicated on the plate, as shown in the figures - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 7
Drainage 1. Run the drain hose sloping downward. Do not install the drain hose as illustrated sideward. 2. When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe, do not let the drain hose slack. Do not block water flow by a rise. Do not block - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 8
unit and the wall. Get it out after finish piping. 4. Push the lower part of the indoor unit up on the wall, Then move the indoor unit from side not to let the drain hose slack. 4. Both of the auxiliary piping should be heat insulation. 5. Be sure that the drain hose is located at the lowest side of - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 9
heavy winds, such as in coastal areas, place the unit along the widest part of the wall or use protective plates. 5. If suspended installation is needed, purchase kit No.EA140S from your local or servicer. The installation bracket should accord with technique requirement in the installation bracket - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 10
Air outlet B( ft) ' Condensate drainage of outdoor unit (no for cooling only) The condensate and defrosting water formd during heating in the outdoor unit can be properly discharged by drainage pipe . Installation method:Insert the drain connection into one of the Ø25 holes - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 11
recommended to cut. If too long, loop for excess. Note: Keep original bend so not kinking of the tube occurs. Flaring work Main cause for refrigerant leakage is due to defect in the flaring work. Carry out correct flaring work using the following procedure: 1. Cut the pipes and the cable. A) Use - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 12
tubing OUTER DIAMETER (inch) 1/4 3/8 1/2 5/8 Flare nut Pipings TIGHTENING TORQUE (lbf.in) 139 260 434 651 ADDITIONAL TIGHTENING TORQUE (lbf.in) 174 304 477 694 17 Refrigerant piping connection - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 13
about the power supply, the technicians should refuse to install the air conditioner and explain to the client until the problem is solved. 2. Power voltage should be in the range of 90%~110%of rated voltage. 5. According to the attached Electrical Connection Diagram located on the - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 14
Connect the cable to the indoor unit 1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible cord, type designation 16AWG or heavier cord. 3. Lift the - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 15
of indoor and outdoor units. 5. Insulate unused cords (conductors) with PVC -tape. P rocess them so they could not touch any electrical or metal parts. &RYHU 6FUHZ Cable Code wire 0.39" 1.57" Terminal block of outdoor unit N(1) 2 3 L N To indoor unit To power supply Electrical work 20 - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 16
conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside heating(only for models with heating function) efficiency drops. 4. Moisture in the refrigerant circuit may freeze and block capillary tubing. 5. Water may lead to corrosion of parts in the refrigeration - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 17
unit. Note that both the liquid and the gas side service valves on the outdoor unit are kept closed at this stage. 2. When relocating the unit to another place, perform evacuation using vacuum pump. 3. Pipe length and refrigerant amount: Connective pipe length Air purging Additional amount of - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 18
Lo Handle Hi Charge hose Vacuum pump display in the pressure indicator is a little higher than the atmosphere pressure. This procedure verifies if the refrigerant goes through the tubes correctly. 7. Close the schrader valve, then remove the valve core tool. Replace the charging port cap. 8. Fully - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 19
Electrical safety Perform the electric safety check after completing installation: 1. Insulated resistance: The insulated resistance must be more than 2M . 2. Grounding work: After finishing grounding work, measure the grounding resistance by visual detection and grounding resistance tester. Make - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 20
(Only for models with heating function), AUTO and FAN to check if all the functions work well. 3. When the ambient temperature is too low(lower than 63oF), the unit cannot be controlled by the remote controller to run in cooling mode, manual operation can be taken. Manual operation is used only when - Frigidaire FRS18PYS2 | Installation Instructions (All Languages) - Page 21
Indoor Outdoor 61°F~86°F 41°F~115°F 61°F~86°F 5°F~86°F 61°F~86°F 41°F~115°F * 23°F~115°F, for the models with low temperature cooling system * only for models with heating function Attention If air conditioner is used outside of the above conditions, certain safety protection features may come
8.
The site must allow for the easy
removal of the connector pipe and
drain hose.
9.
The unit must be installed at a site
protected from direct sunlight.
Precautions for Installation
Installation at the following sites may cause problems. If you must inevitably install
2.
Sites with a high concentration of salinity, such as coastal areas.
3.
Sites with sulfuric gas, such as hot water springs.
4.
Sites with high frequency equipment, such as wireless equipment, welding
machines and medical installations.
5.
Sites with flammable gases or volatile material.
6.
Sites with special environmental conditions.
7.
Laundry rooms.
Indoor Unit
1.
The unit must be installed at a site
that does not obstruct the flow of
air.
2.
The site must support the weight of
the indoor unit.
3.
The site must be easily accessible
for maintenance and replacement
of the air filter.
4.
The site must allow for the
necessary space around the indoor
figure.
that the unit be installed at the
flammable gases.
Choosing the installation site
More
More
More
More
Choosing the installation site
the unit at one of these sites, please consult your local distributor beforehand:
1.
Sites with machine oil.
unit, as shown in the sideward
meter) between the unit and radio
5.
There should be at least 3 feet (1
7.
The indoor unit must be at least 8.2
ft(2.5 meters) from the ground.
6.
It must be far from fire, smoke or
center.
or television devices. It is ideal
than 6
"
than
6"
than
8.2'
than
6"
06
Installation warnings:
Installation
1.
Carefully read the installation manual before beginning.
2.
Follow each step as shown.
3.
Observe all local, state, and national electrical codes and by qualified,
licensed, authorized personnel only.
4.
Pay attention to danger and safety notices