    Preface You have purchased the XG2000C, a compact, 20 port 10 Gigabit Ethernet layer 2 switch that achieves unsurpassed standards of high throughput and low-latency performance. This manual explains the procedures required to install your XG2000C and should be read and understood before you start
  • Fujitsu XG2000C | Hardware Guide - Page 4
    and others, and to prevent property damage. When using the XG2000C, follow the instructions given in this manual. Warning notations Warnings are included throughout this manual in order to prevent injury to the user and/or material damage. These are two levels of warnings, both of which are composed
  • Fujitsu XG2000C | Hardware Guide - Page 5
    . To make this easy, the XG2000C should be located close to the power outlet (wall socket or power strip), and the power outlet must be readily accessible. After the power is disconnected, contact the vendor's service department immediately. Continued use of the XG2000C may cause an electric shock
  • Fujitsu XG2000C | Hardware Guide - Page 6
    engineer. When performing maintenance on the XG2000C, be sure to remove the power plug from the outlet first. Only use the XG2000C if the temperature the power supply.(P.26) To ensure the stability of the rack, fix it to the wall or floor as appropriate.(P.26) Do not install the XG2000C in
  • Fujitsu XG2000C | Hardware Guide - Page 7
    wear, contact the vendor's service department for a replacement label. Safety precautions • The expected life of the XG2000C is approximately five years, Use of this hardware guide, the XG2000C, its firmware, and the management software are the responsibility of the user. • Fujitsu and its partners
  • Fujitsu XG2000C | Hardware Guide - Page 8
    not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested not installed and used in accordance with the instrucrtion manual, may cause harmful interference to radio communications. Operation the XG2000C
  • Fujitsu XG2000C | Hardware Guide - Page 9
    life support system, and missile launch control in weapon systems. Do not use the XG2000C for High Safety Required Use without otherwise ensuring the safety level required. Fujitsu and its related companies assume no liability whatsoever for damages arising from use of the XG2000C by the user in
  • Fujitsu XG2000C | Hardware Guide - Page 10
    , connect, and start the XG2000C. Chapter 3 Troubleshooting This chapter describes what you should do when your XG2000C has problems. Appendix This appendix explains the specifications of the XG2000C, and should be referred to as necessary. Related manuals The following manuals are related to this
  • Fujitsu XG2000C | Hardware Guide - Page 11
    or trademarks of respective companies. The trademark ™ and ® have been omitted from this manual. Product Information The latest product information including technical information, update information, are available from the following web site: http://www.pfu.fujitsu.com/products/xg About This
  • Fujitsu XG2000C | Hardware Guide - Page 12
    10 About This Manual
  • Fujitsu XG2000C | Hardware Guide - Page 13
    manuals 8 Symbols used in this manual 9 Trademarks and abbreviations used in this manual 9 Product Information 9 Chapter 1 Installation 13 1-1 Parts List ...14 1-2 XG2000C Connecting the power cords 34 2-5 Basic Operation 35 2-5-1 Turning the XG2000C on 35 2-5-2 Turning the XG2000C off
  • Fujitsu XG2000C | Hardware Guide - Page 14
    Chapter 3 Troubleshooting 37 3-1 Start-up Problems 38 3-2 Hardware Problems 39 Appendix 41 Appendix-A Specifications 42 A.1 Product Specifications 42 A.2 Installation Specifications 42 12 Contents
  • Fujitsu XG2000C | Hardware Guide - Page 15
    Installation This chapter lists the items that should be in the XG2000C package, describes the names and functions of the various components of the XG2000C. 1 1-1 Parts List 14 1-2 XG2000C Components 16 1-3 Labels ...19
  • Fujitsu XG2000C | Hardware Guide - Page 16
    Cross Cable • Hardware Guide The XG2000C itself. Contains documents necessary to operate the XG2000C. A 3-pin cable to connect the XG2000C to a power supply. A cable to connect the XG2000C to a PC when the settings need to be adjusted. A manual describing the XG2000C hardware and related matters
  • Fujitsu XG2000C | Hardware Guide - Page 17
    R A rail that are attached to the back-right rack post and into which the back rack mounting bracked are slid and fastened when mounting the XG2000C in a rack. • Rail L A rail that are attached to the back-left rack post and into which the back rack mounting bracked are slid and fastened
  • Fujitsu XG2000C | Hardware Guide - Page 18
    receives the Frame. • Serial Port Used when performing maintenance or adjusting the settings (Console connection). • Status LED (Green) Lights when the XG2000C is in an operable state. • Alarm LED (Orange) Lights when there is a problem with the XG2000C. • Power LED (Green) Lights when the
  • Fujitsu XG2000C | Hardware Guide - Page 19
    LED when there is a problem with the Rear Fan Unit. • Power Supply Unit Supplies power to the XG2000C (includes an exhaust fan). - Power Supply LED (Green/Orange) Green LED lights when the XG2000C is on. Orange LED lights when there is a problem with the Power Supply Unit. Attention In order
  • Fujitsu XG2000C | Hardware Guide - Page 20
    the trouble: XG2000C Condition Power Alarm LED Status LED on failed part Problem detected Startup error Rear fan error On ---*3 Blinking --- On On ---*4 Rear Fan LED: Orange Power fan error On On ---*4 Power Supply LED: Orange No AC supply *2 On On ---*4 Power Supply LED
  • Fujitsu XG2000C | Hardware Guide - Page 21
    ID label, and MAC label are to be found in various places on the XG2000C. 1 MAC Label Product ID Label Product ID Label MAC Label Product Nameplate Top view of XG2000C Product Nameplate Right view of XG2000C Warning sticker Obey the following warning: CSA/CE Label FCC Canada Label FCC Label
  • Fujitsu XG2000C | Hardware Guide - Page 22
    FCC Label This indicates statement of Part 15 fo FCC rules. FCC Canada Label This indicates notification of CSA. CSA/CE Label This indicates CE Marking. 20 Installation
  • Fujitsu XG2000C | Hardware Guide - Page 23
    2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 1 1 50/60Hz **** Kg 100-240V *** **** A/INPUT PFU Limited a Fujitsu company MADE IN JAPAN Product ID Label This indicates the model and serial number. MODEL ***** SER. NO +13 Location Mng-LAN XG2000C Port 1 Port 2 Port3 Port 4 Port 5 Port 6 Port 7
  • Fujitsu XG2000C | Hardware Guide - Page 24
    Address on the MAC label xx:xx:xx:xx:xx:xx+14 xx:xx:xx:xx:xx:xx+15 xx:xx:xx:xx:xx:xx+16 xx:xx:xx:xx:xx:xx+17 xx:xx:xx:xx:xx:xx+18 xx:xx:xx:xx:xx:xx+19 xx:xx:xx:xx:xx:xx+20 xx:xx:xx:xx:xx:xx+21 (=yy:yy:yy:yy:yy:yy) Location Port 13 Port 14 Port 15 Port 16 Port 17 Port 18 Port 19 Port 20 22
  • Fujitsu XG2000C | Hardware Guide - Page 25
    chapter explains how the user should proceed from installation to operation of the XG2000C. 2 2-1 Installation Overview 24 2-2 Installation Procedure 25 2-2-1 Installation requirements 25 2-2-2 Installing the XG2000C in a rack 26 2-2-3 Uninstalling the XG2000C from a rack 30 2-3 Installation
  • Fujitsu XG2000C | Hardware Guide - Page 26
    Installation Overview This section reviews the flow of work as the user proceeds from installation to operation of the XG2000C. Install the XG2000C and the proceed with normal operation as follows: 1 Check the components "1-1 Parts List" 2 Check the set up area and install the XG2000C "For Safe Use
  • Fujitsu XG2000C | Hardware Guide - Page 27
    requirements Before installing the XG2000C, read " For Safe Use of the XG2000C (P.2)" and comply with 19-inch rack, refer to the user guide provided with the rack. [540mm (W) X 850mm (D) 19-inch rack] (Unit: mm) 540 Front Service area (Front) Rack (Top) Service area (Rear) 800 850 800 700
  • Fujitsu XG2000C | Hardware Guide - Page 28
    unit's power supply is not drawn directly from the distribution board (such as when a power strip is used, for example). When multiple devices are connected to a single power strip, the combined leakage currents can overwhelm the grounding capacity of the power strip. • Set the XG2000C nearby the
  • Fujitsu XG2000C | Hardware Guide - Page 29
    2. Fix the nuts and rails to the rack posts. First, choose nuts, cage nuts or rack nuts, by the type of hole dug in the rack post. When the rack has square post holes, cage nuts are used. When round holes, rack nuts are used. [When the rack has square post holes] Rack Post Rack Screws (Large)
  • Fujitsu XG2000C | Hardware Guide - Page 30
    [When the rack has round post holes] Rack Post Rack Screws (Large) Rack Post Rack Nuts Rail L Rail R Rack Screws (Large) Rack Post Rack Nuts Front Rack Nuts Refer to Detail A Rack Post Rack Nuts Clip the rack nuts onto the rack post so that the holes are lined up. Detail A [When the rack
  • Fujitsu XG2000C | Hardware Guide - Page 31
    brackets (two of front side, two of back side) has two holes that should line up with matching holes on the sides of the XG2000C, as shown in the diagram. Attach each rack mounting bracket using the countersunk bracket screws provided. Rack Screws (Small) Rack Mounting Bracket B Rack Screws
  • Fujitsu XG2000C | Hardware Guide - Page 32
    completes the rack installation procedure. Rack Post Rack Post 2-2-3 Uninstalling the XG2000C from a rack The following explains how to uninstall the XG2000C from a rack. 1. Undo the rack screws that were used to fasten the XG2000C to the rack. Rack Screws (Small) Rack Screws (Large) 2. Slide the
  • Fujitsu XG2000C | Hardware Guide - Page 33
    the installation of the XFP modules. 2-3-1 Installing the XFP modules The following explains how to install XFP modules in a XG2000C. 1. Install a XFP module in a XG2000C. Install XFP module as in the following manner; (1) Insert the XFP module with the cable connector facings outward. When
  • Fujitsu XG2000C | Hardware Guide - Page 34
    2-3-2 Uninstalling the XFP modules The following explains how to uninstall XFP modules in a XG2000C. 1. Uninstall a XFP module in a XG2000C. Uninstall the XFP module in the following manner; (1) Unlock the XFP module by lower the lever on odd numbered ports. Lift the lever up for
  • Fujitsu XG2000C | Hardware Guide - Page 35
    cables and power cords. 2-4-1 Connecting cables The cables need to be connected to the XG2000C XFP modules and micro GiGa Connectors. 1. Connect the fiber optic cables to the XG2000C. Connect the clear, clean the connector as a first attempt to resolve the problem. Cable Connection 33
  • Fujitsu XG2000C | Hardware Guide - Page 36
    correct position, in order to protect the connector interface against external damage. 2-4-2 Connecting the power cords After connecting the peripheral units, connect the XG2000C power cords. WARNING • Do not touch the power plug with wet hands, as there is a risk of electric shock. • Do not damage
  • Fujitsu XG2000C | Hardware Guide - Page 37
    . CAUTION Do not move, shock, or vibrate the XG2000C while it is on. 1. Connect the power cord to the power outlet. Insert the plug at the other end of the power cord into the power strip or wall socket. The Power LED (Green) on the front of the XG2000C should turn on. The Alarm LED (Orange) should
  • Fujitsu XG2000C | Hardware Guide - Page 38
    yet, then execute "system shutdown" from the command line. For details of the system shutdown dommand, refer to the "Command Reference" section in Refer the "XG2000C User's Guide". 2. Disconnect the power cord to the power outlet. 36 Installation and Operation
  • Fujitsu XG2000C | Hardware Guide - Page 39
    Troubleshooting This chapter describes what you should do when your XG2000C fails to operate properly. 3 3-1 Start-up Problems 38 3-2 Hardware Problems 39
  • Fujitsu XG2000C | Hardware Guide - Page 40
    the vendor's service department. Alarm LED lights, but the XG2000C does not start up [Symptom] The XG2000C has not started within a few minutes of power on and the Alarm LED (Orange) lights. [Cause] Probable hardware failure. [Action] Contact the vendor's service department. 38 Troubleshooting
  • Fujitsu XG2000C | Hardware Guide - Page 41
    is recorded in the event log. In this case, turn the XG2000C off and contact the vendor's service department. Power supply error When a power supply problem is detected, the Alarm LED lights orange, the power supply LED of the power supply unit in which the error has occurred lights orange, and an
  • Fujitsu XG2000C | Hardware Guide - Page 42
    40 Troubleshooting
  • Fujitsu XG2000C | Hardware Guide - Page 43
    Appendix This appendix explains XG2000C specifications. Appendix-A Specifications 42 A.1 Product Specifications 42 A.2 Installation Specifications 42
  • Fujitsu XG2000C | Hardware Guide - Page 44
    (Orange), Status (Green), Rear fan × 2, Power supply units × 2 A.2 Installation Specifications The installation specifications of the XG2000C are as follows: Items Dimensions (Excluding protrusions) Width Depth Height Maximum weight Power Cord Power source Voltage Phase Frequency Input
  • Fujitsu XG2000C | Hardware Guide - Page 45
    XG2000C Hardware Guide P3N1-E122-01EN Date of issue: June 2007 Issuing authority: PFU LIMITED Printed in Japan • Contents of this manual are not to be reproduced without permission from PFU. • The contents of this manual may be updated without notice. • PFU assumes no liability for damages to third
  • Fujitsu XG2000C | Hardware Guide - Page 46
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46