GE DBXR300GG Installation Instructions

GE DBXR300GG Manual

GE DBXR300GG manual content summary:

  • GE DBXR300GG | Installation Instructions - Page 1
    Service information and the wiring diagram are located in the control console. • Do not allow children on or in the appliance. Close supervision of children is necessary when the appliance and Venting. Step 11 Place the Owners Manual and the Installation Instructions in a Location Where They Will Be
  • GE DBXR300GG | Installation Instructions - Page 2
    Instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration must be given to provide adequate clearance for proper operation and service gas appliances. 2
  • GE DBXR300GG | Installation Instructions - Page 3
    Installation Instructions 3 RECONNECTING GAS Listed connector ANSI Z21.24 / CSA 6.10 FLARE NPT fittings are designed for use only on the original installation and are not to be reused for another appliance or at another location. Keep flare end of adaptor free of grease, oil and thread sealant.
  • GE DBXR300GG | Installation Instructions - Page 4
    Instructions 5 ELECTRICAL CONNECTION INFORMATION WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL S HOCK, AND PERSONAL INJURY: • DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE. Dryer must be electrically installation is YOUR RESPONSIBILITY. Problems due to incorrect installation
  • GE DBXR300GG | Installation Instructions - Page 5
    ) duct to connect the dryer to the home exhaust duct. It must be installed in accordance with the instructions found in "Connecting The Dryer To House Vent" on page 6 of this manual. • Do not terminate exhaust in a chimney, a wall, a ceiling, gas vent, crawl space, attic, under an enclosed floor, or
  • GE DBXR300GG | Installation Instructions - Page 6
    Installation Instructions CONNECTING case of a gas leak in the supply line. • No other fuel-burning appliance shall be installed in the same closet with the dryer. feet (2.4m). • the MANUFACTURED HOME CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART 32-80 or, when such standard is not applicable,
  • GE DBXR300GG | Installation Instructions - Page 7
    Instructions 12 DRYER EXHAUST TO LEFT OR BOTTOM CABINET WARNING - BEFORE PERFORMING THIS EXHAUST INSTALLATION, BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL previously to secure the duct in place through the tab on the appliance base. ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT SIDE OF CABINET
  • GE DBXR300GG | Installation Instructions - Page 8
    Installation Instructions ADDING ELBOW FOR EXHAUST THROUGH BOTTOM OF CABINET • Insert the elbow WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION AFTER SERVICING/INST ALLATION. For replacement parts and other information, refer to Owner's Manual for servicing phone
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Installation
Instructions
Gas Dryer
If you have any questions, call 1-800-GECARES (US) or 1-800-361-3400 (Canada)
or
Visit our Web site at:
www. GEAppliances.com
MATERIALS YOU WILL NEED
LEVEL
Step 1
Verify Your Gas Installation (see section 2).
Step 2
Prepare the Area and Exhaust for Installation of
New Dryer (see section 1).
Step 3
Check and Insure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation
Specifications (see section 6).
Step 4 Remove the Foam Shipping Pads (see section 1).
Step 5
Move the Dryer to the Desired Location.
Step 6
Level Your Dryer (see section 8).
Step 7
Connect the Gas Supply (see section 3) and check
for leaks (see section 4).
Step 8
Connect the External Exhaust (see section 7).
Step 9 Connect the Power Supply (see section 5).
Step 10
Check the Operation of the Power Supply, Gas
Connections, and Venting.
Step 11
Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be
Noticed By the Owner.
For Alcove or Closet Installation see section 9.
For Bathroom or Bedroom Installation see section 10.
For Mobile or Manufactured Home see section 11.
8" PIPE WRENCH
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
06
In the state of Massachusetts, installation must be performed by a qualified
or licensed contractor, plumber, or gasfitter qualified or licensed by the state.
WARNING
RISK OF FIRE
To reduce the risk of severe injury or death, follow all installation instructions.
Clothes dryer installation must be performed by a qualified installer.
Install the clothes dryer according to these instructions and in accordance with
local codes. In the absence of local codes, installation must comply with National
Fuel Gas Code, ANSIZ223.1/NFPA 54 or the Canadian Natural Gas and Propane
Installation Code, CSA B149.1.
This dryer must be exhausted to the outdoors.
This act requires the governor of California to publish a list of substances known to the
state to cause cancer, birth defects or other reproductive harm and requires businesses to
warn customers of potential exposure to such substances. Gas appliances can cause minor
exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde
and soot, caused primarily by the incomplete combustion of natural gas or LP fuels.
Properly adjusted dryers will minimize incomplete combustion. Exposure to these
substances can be minimized further by properly venting the dryer to the outdoors.
California Safe Drinking Water and Toxic Enforcement Act
Use only 4” rigid metal ducting for exhausting the clothes dryer to the outdoors.
Do not install or store this appliance in any location where it could be exposed to
water and or weather.
Save these instructions. (Installers: Be sure to leave these instructions with the
customer).
DO NOT install a clothes dryer with flexible plastic ducting materials.
If flexible
metal (semi-rigid or foil-type) duct is installed, it must be UL-listed and installed
in accordance with the instructions found in "Connecting The Dryer To House
Vent" on page 6 of this manual.
Flexible ducting materials are known to collapse,
be easily crushed, and trap lint. These conditions will obstruct dryer airflow and
increase the risk of fire.
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT-
Save these
instructions for local inspector’s use.
IMPORTANT-
Observe
all governingcodes and ordinances.
Note to Installer
- Be sure to leave
these instructions with the customer.
Note to Customer
-
Keep these
instructions with your Use and Care
Book for future reference.
Before the old dryer is removed from
service or discarded, remove the dryer
door.
Service information and the wiring dia-
gram are located in the control console.
Do not allow children on or in the
appliance. Close supervision of child-
ren is necessary when the appliance is
used near children.
Install the dryer where the temp-
erature is above 50°F for satisfactory
operation of the dryer control system.
Inspect the dryer exhaust outlet and
straighten the outlet walls if they are
bent.
EXHAUST HOOD
FLEXIBLE GAS LINE CONNECTOR
SOAP SOLUTION
FOR LEAK DETECTION
PIPE
COMPOUND
DUCT TAPE
GLOVES
SAFETY GLASSES
4" DIAM METAL ELBOW
10" ADJUSTABLE WRENCHES
(x2)
4" DUCT CLAMPS
OR
4" SPRING CLAMPS
(x2)
(x2)
TOOLS YOU
WILL NEED
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)