GE GTD45EASJWS Quick Specs

GE GTD45EASJWS Manual

GE GTD45EASJWS manual content summary:

  • GE GTD45EASJWS | Quick Specs - Page 1
    time-delay fuse, is required. Note: Dryer wall outlet must be located within 36" of service cord entry and acessible when dryer is mounted in position. Installation Information: For complete information, see installation instructions packed with your dryer. Special Installation Requirements Alcove
  • GE GTD45EASJWS | Quick Specs - Page 2
    ™ Series or GE® Series appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000. GE Dryer Vent Dryer exhausting information-use metal duct only vertical and horizontal ducting A A4 B A 2-1/2 4 B Domestic dryer models 2-1/2 GE Front Load Long
  • GE GTD45EASJWS | Quick Specs - Page 3
    - Provides flexible installation Extended Tumble - Freshly tumbles your garments periodically for up to 8 hours when unable to move clothing to the dryer right away End-of-cycle signal - Alerts you when the load is done, so clothes can be removed before wrinkles set in Model GTD45EASJWS - White with
  • 1
  • 2
  • 3

Listed by
Underwriters
Laboratories
GTD45EASJ
GE
®
Series 7.2 Cu. Ft. Capacity Aluminized Alloy Drum Electric Dryer with HE Sensor Dry
Specification Revised 10/15
5
Power
Cord Hole
4-1/2
POWER CORD LOCATIONS
BACK VIEW
SIDE VIEW
REAR VIEW
ELECTRIC DRYER RATING:
240V
5600W
24A
60Hz
208V
4400W
22A
60Hz
EXHAUST OPTION:
4-way rear, right, left and bottom.
CIRCUIT REQUIREMENTS:
An individual, properly-grounded
branch circuit, protected by a 30-amp circuit breaker or a time-delay
fuse, is required.
NOTE:
Dryer wall outlet must be located within 36" of service cord
entry and acessible when dryer is mounted in position.
INSTALLATION INFORMATION:
For complete information, see
installation instructions packed with your dryer.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION:
- If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side; 3" front and rear.
- Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
- Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of
open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a
minimum of 120 sq. in. of open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local codes, with the
National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION:
- Minimum clearances to combustible surfaces are: 0" both sides; 3" rear.
DRYER EXHAUSTING INFORMATION:
Use metal duct only, vertical and horizontal ducting.
22 1/2"
29 1/2"
26"
3 1/2"
1 3/4"
3 1/4"
8"
37 1/2"
44"
27"
5"
Power Cord 4 1/2"
11 3/4"
For answers to your Monogram, GE Profile
Series or GE
®
Series appliance questions, visit our
website at geappliances.com or call GE Answer
Center
®
service, 800.626.2000.