GE PGP989TNWW Quick Specs

GE PGP989TNWW - True 30" Gas Downdraft Cooktop Manual

GE PGP989TNWW manual content summary:

  • GE PGP989TNWW | Quick Specs - Page 1
    PGP989DN/TN GE Profile™ 30" Downdraft Gas Cooktop Dimensions and Installation Information Wall Installation: Wall installations require 25" countertop depth. When cabinet is flush against the wall, the fan housing can be rotated to the horizontal position for direct venting through
  • GE PGP989TNWW | Quick Specs - Page 2
    GE Profile™ 30" Downdraft Gas Cooktop Dimensions and Installation Information Installing the Ductwork: Use galvanized or aluminum duct in 6" round or 3-1/4" x 10" size, or combination of both. PVC duct or locally approved piping should be used if installing shown in installation instructions) for
  • GE PGP989TNWW | Quick Specs - Page 3
    /TN GE Profile™ 30" Downdraft Gas Cooktop Features and Benefits • Downdraft Exhaust - Powerful exhaust system effectively pulls smoke and steam out of the kitchen • Gas On Glass Cooktop - Features a flat one-piece ceramic glass surface that is sleek and easy-to-clean • Sealed Cooktop Burners
  • 1
  • 2
  • 3

Dimensions and Installation Information
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
Listed by
Underwriters
Laboratories
Specification Revised 4/09
230284
*Note: A 5" minimum spacing to adjacent side wall is required
Dimension and installation information are shown in inches.
Wall Installation:
Wall installations require 25”
countertop
depth. When cabinet is flush against
the wall, the fan housing can be rotated to the
horizontal position for direct venting through
rear wall. Make a countertop cutout in the
range cabinet according to unit dimensions
and installation type. Duct hole is positioned in
back of cabinet for through-the-wall ducting.
Requires special offset adapter JXRW89.
Peninsula or Island Installation:
For peninsula/
islands a minimum 26”
countertop
depth is suggested.
Blower should be in vertical position. Island or
peninsula cabinets may require adjustment in cutout
depth and/or location within the width dimensions.
Duct hole is positioned in bottom of cabinet for island
or peninsula installation.
Slab Installation:
For peninsula or island installation
and rear wall ducting,
6” PVC duct or locally
approved piping should be used if installing under
a poured concrete slab.
Installation Information:
Before installing, consult
installation instructions, packed with product, for
current dimensional data.
Note: These cooktops are approved for indoor use only.
20
9
4
10-1/2
16
C
L
22
7
/
16
ʺ
(22
9
/
16
ʺ
SS)
20
1
/
2
ʺ
22
ʺ
29
7
/
8
ʺ
(30
ʺ
SS)
2
3
/
16
ʺ
(2
1
/
4
ʺ
SS)
28
3
/
4
ʺ
PGP989DN/TN
GE Profile
30" Downdraft Gas Cooktop
25
1-7/8"
MIN. Required*
20-5/8
28-7/8
*U.L. Requirement.
Note:
A 5" minimum spacing to adjacent side wall is required