GE PHB920EJES Quick Specs
GE PHB920EJES Manual
View all GE PHB920EJES manuals
Add to My Manuals
Save this manual to your list of manuals |
GE PHB920EJES manual content summary:
- GE PHB920EJES | Quick Specs - Page 1
INSTALLATION INFORMATION: Before installing, consult installation instructions for current dimensional data and additional GE Café™ Series, GE Profile™ Series or GE® Series appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000. All GE ranges - GE PHB920EJES | Quick Specs - Page 2
PHB920EJ GE Profile™ Series 30" Free-Standing Convection Range with Induction FEATURES AND BENEFITS Edge-to-edge cooktop - A large, seamless surface Hidden bake oven interior - Make cleanup easy by eliminating hard-to-reach areas Model PHB920EJES - Slate PHB920SJSS Specification Created 12/15
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
Specification Created 12/15
Listed by
Underwriters
Laboratories
All GE ranges are equipped with
an Anti-Tip device. The installation
of this device is an important,
required step in the installation
of the range.
PHB920EJ
GE Profile
™
Series 30" Free-Standing Convection Range with Induction
For answers to your Monogram, GE Caf
é
™
Series,
GE Profile
™
Series or GE
®
Series appliance questions,
visit our website at geappliances.com or call
GE Answer Center
®
service, 800.626.2000.
30"
25"
2-1/2"
2-1/2"
7-1/2"
29-7/8"
47"
11"
35-3/4"
to
36-1/2"
w/o handle
w/handle
47-5/8"
28"
25-3/8"
ACCEPTABLE ELECTRICAL
OUTLET AREA
RECEPTACLE LOCATIONS
Locally approved flexible service cord or conduit must
be used because terminals are not accessible after range
installation. See shaded area in drawing for location of
electrical outlet box. Recommended outlet locations allow
range to be installed directly against wall.
NOTE:
This appliance has been approved for 0" spacing
to adjacent surfaces above the cooktop. However, a 6"
minimum spacing to surfaces less than 15" above the
cooktop and adjacent cabinet is recommended to reduce
exposure to steam, grease splatter and heat.
INSTALLATION INFORMATION:
Before installing,
consult installation instructions for current dimensional
data and additional requirements.
†
NOTE:
Check local codes for required breaker size.
KW RATING
240V
12.4
208V
10.3
BREAKER SIZE
240V
40 Amps
†
208V
40 Amps
†