GE UVB36DKBB Quick Specs

GE UVB36DKBB Manual

GE UVB36DKBB manual content summary:

  • GE UVB36DKBB | Quick Specs - Page 1
    recommended to be installed with cooktops that are flush mounted. Approved for use with the following8-M1/2o"n8-o1g/2r"am, GE Profile™ Series and GE® Series cooktops-36" Floor or GE® Series appliance questions, visit our website at geappliances.com or call GE Answer Center service, 800.626
  • GE UVB36DKBB | Quick Specs - Page 2
    ducting should not exceed the maximum recommendation of 100 feet for optional venting performance. For answers to your Monogram, GE Profile™ Series or GE® Series appliance questions, visit our website at geappliances.com or call GE Answer Center service, 800.626.2000. Specification Created 10/15
  • GE UVB36DKBB | Quick Specs - Page 3
    and moisture out of the kitchen air Telescopic hood - Raises over cooktop surface and retracts when not in use Separate remote raise/lower switch Model UVB36DKBB - Black on Black JVB36/30DK Specification Created 10/15
  • 1
  • 2
  • 3

UVB36DK
Universal 36" Telescopic Downdraft System
Specification Created 10/15
For answers to your Monogram, GE Profile
Series
or GE
®
Series appliance questions, visit our website
at geappliances.com or call GE Answer Center
service, 800.626.2000.
NOTE:
Telescopic downdraft vents are not
recommended to be installed with cooktops
that are flush mounted.
Approved for use with the following Monogram,
GE Profile
Series
and GE
®
Series cooktops–36"
electric models, 36" gas-sealed burner models
and 36" induction models.
NOT APPROVED FOR USE WITH STANDARD
BURNER GAS COOKTOPS.
NOTE:
The cooktop must be at least 26" deep with
a flat surface area of 23-1/2" or more, front to back.
In addition, other clearances to the front edge of the
countertop must be considered.
NOTE:
Dimensions shown are for reference only.
Before cutting out countertop, refer to instructions
packed with downdraft and cooktop.
NOTE:
Installation on cabinets/countertops against
the wall will not be possible in most applications.
Against the wall installations are limited to
dimension requirements. Refer to installation
instructions packed with product for further details.
JXRB67 INDOOR REMOTE ACCESSORY.
Optional accessory may be ordered for installation
of motor and blower assembly in an indoor remote
location.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
23-5/8"
33-15/16"
36"
2"
1-1/2"
2-1/4"
9-1/2"
8-1/2"
Lift
32-3/8"
Locate the Gas or Electrical
Connection Only Within the
Shaded Area
DO NOT Locate
Gas or Electrical
Connections within
this Area
29-1/2"
12"
Electrical
Outlet 12"
Above
Cabinet
Floor
2-1/8"*
8-1/2"
36"
*Minimum distance required between
the back edge of the cooktop
and the back of the cutout
in the countertop