Genie IntelliG 1200 Owner's Manual

Genie IntelliG 1200 Manual

Genie IntelliG 1200 manual content summary:

  • Genie IntelliG 1200 | Owner's Manual - Page 1
    GARAGE DOOR OPENER MODELS PowerMax® 1200/1500, SC 1200/1500, TriloGTM 1200/1500, PowerLift® 900, GPowerTM 900, SilentMax® 1000/1200, CB 1000/1200, IntelliG® 1000/1200 SCREW/BELT/CHAIN DRIVES OPERATION & MAINTENANCE MANUAL Includes INTELLICO®DE 2 Remote Control. Safe-T-Beam® System must be installed
  • Genie IntelliG 1200 | Owner's Manual - Page 2
    6 Opening Garage Door (UP Limits 7 Wall Console Overview 8 Series III Wall Consoles with Black Buttons... 8 Series II Wall Consoles with White Buttons.... 8 Force and Speed Control 9 Contact Reverse Test 9 Remotes/New Intellicode 2 Openers 10 O5ptional 6Program7ming Keypad 12
  • Genie IntelliG 1200 | Owner's Manual - Page 3
    NOT connect the operator to the source of power until instructed to do so. • Locate the wall console button: A) Within sight of door. B) At a minimum height of 5 feet so small children cannot reach it. C) Away from all moving parts of the door. • Install the entrapment WARNING label next to the
  • Genie IntelliG 1200 | Owner's Manual - Page 4
    door opener from inside garage. The wall console has an indicator light with: Open/Close, Sure-Lock™, and independent light control buttons. Home Link and Car2U® compatible. Refer to the programming instructions on page 11. NOTE: Use this manual ONLY after completing assembly and installation
  • Genie IntelliG 1200 | Owner's Manual - Page 5
    no objects in the garage door opening. INTRODUCTION Now that your Genie garage door opener is installed, you will want to program the opener so that the door opens and closes properly and all remote devices operate correctly. The following steps guide you through setting your opener so it functions
  • Genie IntelliG 1200 | Owner's Manual - Page 6
    door open by hand until the shuttle/bullet engages the carriage on the rail. 4 Press and hold the down arrow button (-) until garage door is fully closed on floor, then release. PROGRAM SET + HOLD 1 2 1 2 Press and hold the down arrow button (-) for 2 seconds until the long LED comes on blue
  • Genie IntelliG 1200 | Owner's Manual - Page 7
    carriage as it approaches the power head to avoid contact with powerhead. PROGRAM SET - HOLD Opening Garage Door (Up Limits) NOTE: Beginning with garage door closed is recommended but not necessary. 6 Press and hold the up arrow button (+) for 2 seconds until the long LED light comes on blue
  • Genie IntelliG 1200 | Owner's Manual - Page 8
    Light Control Button Controls door opener lights from inside garage. 8 Series III Wall Consoles with Black Buttons Indicator Light Indicator light will display Red when wall console is properly wired and Sure-Lock™ is OFF. When Sure-Lock™ is ON, indicator light flashes. Open/Close Button
  • Genie IntelliG 1200 | Owner's Manual - Page 9
    COMPLETED before performing the Contact Reverse Test. 11 Open the garage door using the Open/Close button on the Wall Console. When the door contacts the board, it should stop and reverse direction within 2 seconds to the fully OPEN position. Red LED lights on the powerhead will begin to ash with
  • Genie IntelliG 1200 | Owner's Manual - Page 10
    LED turns blue). 16 Remove protective film for battery from remote. PUL PROGRAM - + HOLD 2 seconds 15 Release the Program Set button (the long LED begins flashing purple). PROGRAM 17 Press and release the button you have choosen on the Remote (long LED comes on purple). - + 10 G999-393 Manual
  • Genie IntelliG 1200 | Owner's Manual - Page 11
    the same button on the remote (both LED's flash blue and then turn off). The Remote button is now programmed. Repeat as necessary for additional Remotes. To program the same Remote for other garage door openers, repeat the steps above using one of the other two Remote buttons. Each Remote can be
  • Genie IntelliG 1200 | Owner's Manual - Page 12
    key . Opener LEDs will stay on steady. Note: For multiple doors, see the full instructions packed with the keypad. 12 1. Enter your current PIN, then press Program key . 2. Enter your new PIN, press Program key . Note: If you are still having trouble with the keypad, refer to the full instructions
  • Genie IntelliG 1200 | Owner's Manual - Page 13
    up arrow button (+) and down arrow button (-) simultaneously on the Powerhead and hold until both LEDs flash blue and then go OFF. PROGRAM PROGRAM SET SET HOLD HOLD If the memory has been cleared, the Remote will not activate the door opener. NOTE: The garage door opener will operate normally
  • Genie IntelliG 1200 | Owner's Manual - Page 14
    RED LED on the Remote back to GREEN for operation with Intellicode® 2 openers. Once the LED on the Remote turns RED when the button is pressed, that button is programmed to the Intellicode® 1. 3 Find the Learn Code Button and Learn Code Indicator LED on your older Genie® door opener. If your door
  • Genie IntelliG 1200 | Owner's Manual - Page 15
    /belt drive models: One-Piece Doors will only accept a straight door arm. Straight door arm 3/8"-16 x 7/8" Bolt 3/8" Lock nut Straight door arm (not included) 2 Secure door arm to the door bracket and with clevis pin and cotter pin. Door bracket Cotter pin Straight door arm G999-393 Manual
  • Genie IntelliG 1200 | Owner's Manual - Page 16
    and reverse to the fully open position. C. Door Balance (Spring Tension) Perform the check as follows: • With the door closed, pull manual emergency release handle DOWN and let go to release door carriage assembly from drive system. • Raise and lower the door manually-it should move freely and
  • Genie IntelliG 1200 | Owner's Manual - Page 17
    drive models: Verify bullet is engaged to carriage. Pull/release cord down and back towards opener and let go. Screw Drive Opener Belt/Chain Drive Opener Disengaged Engaged Disengaged Engaged - Operate door using a remote or wall console. - Door will re-attach itself to carriage assembly
  • Genie IntelliG 1200 | Owner's Manual - Page 18
    up and down buttons 2 seconds or until round LED turns RED. 2 Press either until you reach desired setting. 3 Press and release. PROGRAM SET 4 Press either until you reach the desired setting. 5 Press and release. PROGRAM SET LED Indication/Result RED OFF BLUE OFF Flashes 3 Times The
  • Genie IntelliG 1200 | Owner's Manual - Page 19
    : Speed Level High Medium Low OFF Blue Purple Red Powerhead LEDs LONG LED ROUND LED RED RED PURPLE PURPLE BLUE BLUE Note: One-piece doors are automatically set to the slowest speed during Limits programming and cannot be adjusted. Note: PowerLift® 900, GPower™ 900 openers DO NOT have speed
  • Genie IntelliG 1200 | Owner's Manual - Page 20
    COVER MAY CAUSE ELECTRIC SHOCK. Disconnect power from opener prior to removing cover. POWER CORD CONNECTOR WHITE PRINTED CIRCUIT BOARD BLACK GREEN CHOKE * WHITE WHITE BLACK BLACK 76 5432 1 CHAIN MOTOR BLACK RED SCREW DRIVE MOTOR RED BLACK 1234 STRIPED WHITE STB 1 2 BWC 3 4 (IWC
  • Genie IntelliG 1200 | Owner's Manual - Page 21
    Beam® Red LED is flashing. • Check Safe-T-Beam® system for beam obstruction or misalignment of lenses. • Check garage door for binding. • If an operational problem exists, and opener will not close, the opener can be forced to close as follows: Press and hold the wall console button until door is
  • Genie IntelliG 1200 | Owner's Manual - Page 22
    If carriage travel is less than 6-feet, opener configures programming for a one-piece door. • Contact The Genie Company at 1-800-35GENIE concerning door speed. POWERHEAD LEDS Powerhead LED Round LED Long LED OFF OFF ON/RED/ STEADY ON/RED/ FLASHING ON/BLUE/ FLASHING ON/PURPLE/ FLASHING ON/RED
  • Genie IntelliG 1200 | Owner's Manual - Page 23
    GMI Holdings, Inc d/b/a The Genie Company ("Seller") warrants to the original purchaser of the below identified, SilentMax® 1000/1200, CB 1000/1200, IntelliG® 1000/1200, PowerMax® 1200/1500, SC 1200/1500, TriloG™ 1200/1500, PowerLift® 900, or GPower™ 900 garage door openers, ("Product"), subject to
  • Genie IntelliG 1200 | Owner's Manual - Page 24
    all Genie garage door openers manufactured from 1993 to the present • Operates up to 3 openers • Large, easy to find buttons for activation Upgrade with style Convenience, Security All in One Keyless Entry Pad • Wireless; can open door without remote • Lighted keypad with flip-up cover • Controls
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

For Answers and Assistance:
1.800.354.3643
or visit www.geniecompany.com
SAVE THIS MANUAL FOR FUTURE REFERENCE
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER
GARAGE DOOR OPENER MODELS
PowerMax
®
1200/1500, SC 1200/1500, TriloG
TM
1200/1500, PowerLift
®
900, GPower
TM
900,
SilentMax
®
1000/1200, CB 1000/1200, IntelliG
®
1000/1200
SCREW/BEL
T/CHAIN DRIVES
OPERA
TION & MAINTENANCE MAN
UAL
Genie, Genie logo, Intellicode, Safe-T-Beam, IntelliG, PowerMax, PowerLift, ChainMax and SilentMax are registered trademarks TriloG and GPower are trademarks of GMI Holdings, Inc., dba The Genie Company
Homelink is a registered trademark of Johnson Controls Technology Company. Car2U is a registered trademark of Lear Corporation. ©The Genie Company 2012 PN#38209501773, 9/2012
WARNING
T
o reduce the risk of injury to persons or damage to property – Use this opener only with a one-piece or sectional door
.
38209501773
Need help or have questions? DO NOT RETURN to the store
.
Call us
:
800-354-3643
Includes INTELLICODE
®
2 Remote Control. Safe-T-Beam
®
System must be installed to close door.
For use only with residential sectional or one piece overhead garage doors.
Homelink
®
and Car2U
®
compatible.