Haier CPN11XCJ Installation Manual

Haier CPN11XCJ Manual

Haier CPN11XCJ manual content summary:

  • Haier CPN11XCJ | Installation Manual - Page 1
    Manual of Room Air Conditioner Read this manual before installation Explain sufficiently the operating means to the user according to this manual parts No. Accessory parts Number of articles 1 Remote controller 1 Optional parts for piping 2 R-03 dry battery 2 Mark A Parts Pipe supporting
  • Haier CPN11XCJ | Installation Manual - Page 2
    wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of connected with the outdoor unit. Place, where cold air can be spread in a room entirely. Place, they become Iow temperature in operation. Use optional parts for piping set or pipes covered with equivalent
  • Haier CPN11XCJ | Installation Manual - Page 3
    Indoor unit Indoor unit 1.Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed 1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel
  • Haier CPN11XCJ | Installation Manual - Page 4
    and pull it out on the front side, then connect them. 3. Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape Lid for right piping Lid for under piping Lid for left piping Heat
  • Haier CPN11XCJ | Installation Manual - Page 5
    is not correct, proper operation can not be carried out and will cause defect. 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). 2. If the fuse on PC board
  • Haier CPN11XCJ | Installation Manual - Page 6
    Outdoor unit Outdoor unit 1.Installation of Outdoor Unit Install according to Drawing for the installation of indoor and outdoor units 2.Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe,and the bending radius should be 30 to 40 mm or longer.
  • Haier CPN11XCJ | Installation Manual - Page 7
    amount No need 40 g 10m 100g Note: When extending piping, air inside piping shall be removed by using external refrigerant gas, charge according . Only for first installation, this extra 50g can be used to purge air in pipes. During this procedure, 50g refrigerant will be discharged in piping.
  • Haier CPN11XCJ | Installation Manual - Page 8
    be exclusively used for air conditioner. (Over 25A) In the case of installing an air conditioner in a moist to our customers how to operate through the instruction manual. Check Items for Test Run Put check normally lighting? Are cooling and heating (when in heat pump) performed normally? Is
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

No.0010515847
Installation Manual of Room Air Conditioner
Read this manual before installation
1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
9.Nipper
12.Reamer
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Explain sufficiently the operating means to the user
according to this manual.
A
B
C
D
E
F
G
Optional parts for piping
Mark
Parts name
Non-adhesive tape
Adhesive tape
Saddle(L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
Arrangement of piping directions
Rear left
Rear
right
Left
Below
Right
The marks from
to
in the figure are the parts numbers.
The distance between the indoor unit and the floor should be
more than 2m.
A
G
Attention must be paid to
the rising up of drain hose
more than 5cm
more than 10cm
more than 10cm
A
C
No.
Accessory parts
Remote controller
R-03 dry battery
Mounting plate
Drain hose
Steel nail, cement
Screw
Plastic cap
Cover
Cushion
1
1
2
3
4
5
6
7
8
9
2
1
1
6
4
1
4
1
Number
of
articles
Accessory parts
4X50
4X25
Pipe supporting plate
more than 10cm
more than 60cm
more than 15cm
more than 10cm
D
E
Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation