Hayward AQ-SOL-LV Operation Manual

Hayward AQ-SOL-LV Manual

Hayward AQ-SOL-LV manual content summary:

  • Hayward AQ-SOL-LV | Operation Manual - Page 1
    Aqua Solar Electronic Solar Control Center Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP www.haywardnet.com
  • Hayward AQ-SOL-LV | Operation Manual - Page 2
    always be followed, including the following: • READ AND FOLLOW ALL INSTRUCTIONS • Disconnect all AC power during installation. • Warning - To reduce be connected to the grounding means provided in the electrical supply service panel with a continuous copper wire equivalent in size to the circuit
  • Hayward AQ-SOL-LV | Operation Manual - Page 3
    Table of Contents SPECIFICATIONS Specifications 1 OPERATION Controls 2 Temperature Display 3 INSTALLATION Mounting 4 Wiring 4 Jumper Settings 9 TROUBLESHOOTING Troubleshooting 10 WARRANTY Warranty 12
  • Hayward AQ-SOL-LV | Operation Manual - Page 4
    differential temperature control for solar heating of pools, spas, and hot tubs. The Aqua Solar is available in 3 models; AQ-SOL-LV, AQ-SOL-LV-TC and AQ-SOL-LV-SP. These models provide differential temperature control with an adjustable calibrated water temperature high limit. Both offer a built-in
  • Hayward AQ-SOL-LV | Operation Manual - Page 5
    for the correct time, the desired hours of filtration, and "auto" operation (model AQ-SOL-LV-TC only) The "Heating" LED will show when the pool is being solar heated. If This switch does NOT remove power from the unit--to service the equipment, disconnect power at the main circuit breaker. DESIRED
  • Hayward AQ-SOL-LV | Operation Manual - Page 6
    TIME CLOCK -- MANUAL CONTROL The manual control can override the timer and is located at approximately the 4 o'clock position problem is detected with the pool sensor (open or short circuit). Solar Sensor: A problem is detected with solar sensor (open or short circuit). Aux Sensor: A problem is
  • Hayward AQ-SOL-LV | Operation Manual - Page 7
    wiring to solar diverter valve Most installations use a solar valve, which diverts water through the collector panels when solar heat is available. For Hayward, Jandy, and Compool valve actuators (with wire end connectors), two 3-pin connectors are supplied. Plug the actuator into one of the Aqua
  • Hayward AQ-SOL-LV | Operation Manual - Page 8
    relays (industry standard) may be added to the AQSOL-LV. The AQ-SOL-LV-TC model comes with one relay for the filter pump control already installed and one additional relay may be added. Order additional relays separately (Hayward p/n AQ-RELAY). The relays are industry standard and are double pole
  • Hayward AQ-SOL-LV | Operation Manual - Page 9
    Pool Sweep Filter Pump 240 VAC Ground 240 VAC Filter Pump Timer Pool Filter Pump Be careful not to cross phases on filter pump wiring AQ-SOL-LV with Solar Override & Boost Pump Boost relay power connected to LOAD side of Filter Pump Timer to ensure that boost pump only runs when filter
  • Hayward AQ-SOL-LV | Operation Manual - Page 10
    as a junction for pump wiring. 2) Most codes require that each pump be on a separate circuit. AQ-SOL-LV-TC with filter pump & pool sweep relays 120/240 VAC Pool Sweep Timer 240 VAC Aqua Solar (AQ-SOL-LV-TC) Booster Pump Pool Sweep Filter Pump 240 VAC Ground Sweep Pump Filter Pump NOTES: 1) Do
  • Hayward AQ-SOL-LV | Operation Manual - Page 11
    prime while air is being purged from the solar collector array. For model, AQ-SOL-LV-TC the relay will also turn the pool sweep off whenever the filter pump is 6. Be careful to make sure the phases do not get reversed. AQ-SOL-LV-TC: This relay is the primary control for the filter pump-there is no
  • Hayward AQ-SOL-LV | Operation Manual - Page 12
    that the system is unprotected in the event of a power failure. Hayward highly recommends that one or more "freeze snap switches" (model GC will override the filter pump timeclock (external timeclock for AQ-SOL-LV or internal timeclock for AQ-SOL-LV-TC) and turn the filter pump on whenever there is
  • Hayward AQ-SOL-LV | Operation Manual - Page 13
    Troubleshooting 1. "Power" LED off: Check main power circuit breakers. Check to see if the Aqua Solar power is connected to the LOAD side of the filter
  • Hayward AQ-SOL-LV | Operation Manual - Page 14
    case digital pool temperature display for the "SOLAR" sensor will show as "CErr". The solar heating and cooling functions will remain off until this problem is fixed, however, the recirculate freeze protection (if enabled by the jumper) will still operate properly. Use the chart on the back cover to
  • Hayward AQ-SOL-LV | Operation Manual - Page 15
    or repair, please contact the place of purchase or the nearest Hayward authorized warranty service center. For more information, please contact the Hayward Technical Service Support Center or visit us on the web at www.haywardnet.com. Hayward will not assume any of the cost incurred in removal or
  • Hayward AQ-SOL-LV | Operation Manual - Page 16
    Temperature/Resistance /Voltage All Hayward controls use a 10K thermistor sensors. When disconnected from the control, the sensor will read 10K ohms at 25ºC/77ºF. Refer 3.61 80 9,297 2.41 120 3,758 1.37 160 1,688 0.72 620 Division St. Elizabeth, NJ 07207 092008F RevG Copyright © 2010 Hayward Inc.
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

Electronic Solar Control Center
Operation and Installation
Manual
AQ-SOL-LV
AQ-SOL-LV-TC
AQ-SOL-LV-SP
www.haywardnet.com
Aqua Solar