HP 8/24 Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008
HP 8/24 Manual
View all HP 8/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP 8/24 manual content summary:
- HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 1
53-1000600-02 12 March 2008 Fabric OS Message Reference Supporting Fabric OS v6.1.0 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 2
the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd. Brocade Communications Systems, Incorporated Corporate Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San Jose - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 3
Manual 1001 Fabric OS System Error Message 53-1000046-01 Added BM, FCR, IPS, FCIP, SEC, and ZONE January 2006 Reference Manual Deleted USWD chapter. -Updated Introductory chapters. -Update throughout: rebranding, supported hardware, CLI changes. 15 June 2007 Fabric OS Message Reference 53 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 4
iv Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 5
In this chapter xlvii How this document is organized xlvii Supported hardware and software xlvii What's new in this document xlviii 1 Event Auditing 2 System Logging Daemon (syslogd 3 System Console 3 Port Logs 4 Viewing and Configuring System Message Logs 4 Viewing System Messages from - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 6
Responding to a System Message 11 Looking Up a System Message 11 Gathering Information About the Problem 12 Support 12 Panic Dump and Core Dump Files 12 Trace Dumps 13 supportSave Command 13 System Module Descriptions 13 Section I RASLog Messages Chapter 2 AG System Messages AG-1001 23 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 7
-1026 37 AUTH-1027 37 AUTH-1028 38 AUTH-1029 38 AUTH-1030 38 AUTH-1031 39 AUTH-1032 39 AUTH-1033 39 AUTH-1034 40 AUTH-1035 40 AUTH-1036 40 AUTH-1037 41 Fabric OS Message Reference vii 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 8
Chapter 4 Chapter 5 AUTH-1038 41 AUTH-1039 41 AUTH-1040 42 AUTH-1041 42 AUTH-1042 42 AUTH-1043 43 AUTH-1044 43 BKSW System Messages BKSW-1003 45 BL System Messages BL-1000 47 BL-1001 47 BL-1002 47 BL-1003 48 BL-1004 48 BL-1006 48 BL-1007 49 BL-1008 49 BL-1009 49 BL-1010 50 BL-1011 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 9
Chapter 6 Chapter 7 Chapter 8 BL-1026 55 BL-1027 56 BL-1028 56 BL-1029 56 BL-1030 57 BL-1031 57 BL-1032 57 BL-1033 57 BL-1034 58 BL-1035 58 BL-1036 58 BL-1037 59 BLL System Messages BLL-1000 61 BM System Messages BM-1001 63 BM-1002 63 BM-1003 63 BM-1004 64 BM-1005 64 BM-1006 64 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 10
Chapter 9 CDR System Messages CDR-1001 71 CDR-1002 71 CDR-1003 71 CDR-1004 72 Chapter 10 CER System Messages CER-1001 73 Chapter 11 CONF System Messages CONF-1000 75 CONF-1001 75 CONF-1020 75 CONF-1021 76 CONF-1022 76 CONF-1030 76 Chapter 12 EM System Messages EM-1001 77 EM-1002 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 11
EM-1029 83 EM-1031 83 EM-1033 84 EM-1034 84 EM-1035 84 EM-1036 85 EM-1037 85 EM-1041 86 EM-1042 86 EM-1043 86 EM-1044 86 EM-1045 87 EM-1046 87 EM-1047 87 EM-1048 88 EM-1049 88 EM-1050 88 EM-1051 88 EM-1055 89 EM-1056 89 EM-1057 89 EM-1058 90 EM-1059 90 EM-1060 90 EM-1061 91 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 12
ESS-1005 96 Chapter 14 EVMD System Messages EVMD-1001 97 Chapter 15 FABR System Messages FABR-1001 99 FABR-1002 99 FABR-1003 99 FABR-1004 100 FABR-1005 100 FABR-1006 100 FABR-1007 101 FABR-1008 101 FABR-1009 101 FABR-1010 102 FABR-1011 102 FABR-1012 102 FABR-1013 103 FABR-1014 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 13
FABR-1037 109 FABR-1038 109 FABR-1039 109 Chapter 16 FABS System Messages FABS-1001 111 FABS-1002 111 FABS-1004 111 FABS-1005 112 FABS-1006 112 FABS-1007 112 FABS-1008 113 FABS-1009 113 FABS-1010 113 FABS-1011 113 FABS-1012 114 FABS-1013 114 FABS-1014 114 FABS-1015 115 Chapter 17 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 14
Chapter 22 FCR System Messages FCR-1001 127 FCR-1002 127 FCR-1003 127 FCR-1004 127 FCR-1005 128 FCR-1006 128 FCR-1007 128 FCR-1008 128 FCR-1009 129 FCR-1010 129 FCR-1011 129 FCR-1012 130 FCR-1013 130 FCR-1015 130 FCR-1016 130 FCR-1018 131 FCR-1019 131 FCR-1020 131 FCR-1021 132 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 15
Fabric OS Message Reference 53-1000600-02 FCR-1039 137 FCR-1040 137 FCR-1041 137 FCR-1042 138 FCR-1043 138 FCR-1048 138 FCR-1049 138 FCR-1053 139 FCR-1054 139 FCR-1055 139 FCR-1056 140 FCR-1057 140 FCR-1058 140 FCR-1059 141 FCR-1060 141 FCR-1061 141 FCR-1062 141 FCR-1063 142 FCR- - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 16
FCR-1083 148 FCR-1084 148 Chapter 23 FICON System Messages FICN-1003 149 FICN-1004 149 FICN-1005 150 FICN-1006 150 FICN-1007 150 FICN-1008 151 FICN-1009 151 FICN-1010 151 FICN-1011 151 FICN-1012 152 FICN-1013 152 FICN-1014 152 FICN-1015 153 FICN-1016 153 FICN-1017 153 FICN-1018 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 17
Fabric OS Message Reference 53-1000600-02 FICN-1036 158 FICN-1037 158 FICN-1038 159 FICN-1039 159 FICN-1040 159 FICN-1041 160 FICN-1042 160 FICN-1043 160 FICN-1044 160 FICN-1045 161 FICN-1046 161 FICN-1047 161 FICN-1048 162 FICN-1049 162 FICN-1050 162 FICN-1051 162 FICN-1052 163 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 18
FICN-1079 170 FICN-1080 171 FICN-1081 171 FICN-1082 171 FICN-1083 171 FICN-1084 172 FICN-1085 172 FICN-1086 172 Chapter 24 FICU System Messages FICU-1001 173 FICU-1002 173 FICU-1003 173 FICU-1004 174 FICU-1005 174 FICU-1006 174 FICU-1007 175 FICU - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 19
Chapter 27 FSPF System Messages FSPF-1001 181 FSPF-1002 181 FSPF-1003 181 FSPF-1005 182 FSPF-1006 182 Chapter 28 FSS System Messages FSS-1001 183 FSS-1002 183 FSS-1003 183 FSS-1004 184 FSS-1005 184 FSS-1006 184 FSS-1007 184 Chapter 29 FSSM System Messages FSSM-1002 187 FSSM-1003 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 20
FW-1037 193 FW-1038 194 FW-1039 194 FW-1040 194 FW-1041 195 FW-1042 195 FW-1043 195 FW-1044 196 FW-1045 196 FW-1046 196 FW-1047 196 FW-1048 197 FW-1049 197 FW-1050 197 FW-1051 198 FW-1052 198 FW-1113 198 FW-1114 198 FW-1115 199 FW-1116 199 FW-1117 199 FW-1118 200 FW-1119 200 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 21
Fabric OS Message Reference 53-1000600-02 FW-1134 205 FW-1135 206 FW-1136 206 FW-1137 206 FW-1138 206 FW-1139 207 FW-1140 207 FW-1160 207 FW-1161 208 FW-1162 208 FW-1163 208 FW-1164 209 FW-1165 209 FW-1166 209 FW-1167 210 FW-1168 210 FW-1169 210 FW-1170 211 FW-1171 211 FW-1172 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 22
FW-1190 217 FW-1191 217 FW-1192 217 FW-1193 218 FW-1194 218 FW-1195 218 FW-1216 219 FW-1217 219 FW-1218 219 FW-1219 220 FW-1240 220 FW-1241 220 FW-1242 221 FW-1243 221 FW-1244 221 FW-1245 222 FW-1246 222 FW-1247 222 FW-1248 223 FW-1249 223 FW-1250 223 FW-1251 224 FW-1272 224 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 23
Fabric OS Message Reference 53-1000600-02 FW-1307 229 FW-1308 229 FW-1309 229 FW-1310 230 FW-1311 230 FW-1312 230 FW-1313 231 FW-1314 231 FW-1315 231 FW-1316 232 FW-1317 232 FW-1318 232 FW-1319 233 FW-1320 233 FW-1321 233 FW-1322 234 FW-1323 234 FW-1324 234 FW-1325 235 FW-1326 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 24
FW-1344 241 FW-1345 241 FW-1346 242 FW-1347 242 FW-1348 243 FW-1349 243 FW-1350 243 FW-1351 244 FW-1352 244 FW-1353 244 FW-1354 245 FW-1355 245 FW-1356 246 FW-1357 246 FW-1358 246 FW-1359 247 FW-1360 247 FW-1361 247 FW-1362 248 FW-1363 248 FW-1364 248 FW-1365 248 FW-1366 249 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 25
FW-1401 254 FW-1402 254 FW-1403 255 FW-1424 255 FW-1425 255 FW-1426 255 FW-1427 256 FW-1428 256 FW-1429 256 FW-1430 257 FW-1431 257 FW-1432 257 FW-1433 257 FW-1434 258 FW-1435 258 FW-1436 258 FW-1437 259 FW-1438 259 FW-1439 259 FW-1440 260 FW-1441 260 FW-1442 260 FW-1443 260 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 26
Chapter 32 HAMK System Messages HAMK-1001 267 HAMK-1002 267 HAMK-1003 267 HAMK-1004 268 Chapter 33 HIL System Messages HIL-1101 269 HIL-1102 269 HIL-1103 269 HIL-1104 270 HIL-1105 270 HIL-1106 270 HIL-1107 271 HIL-1108 271 HIL-1201 271 HIL-1202 272 HIL-1203 272 HIL-1204 272 HIL- - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 27
HIL-1501 277 HIL-1502 278 HIL-1503 278 HIL-1504 278 HIL-1505 279 HIL-1506 279 HIL-1507 279 HIL-1508 280 HIL-1509 280 HIL-1510 280 HIL-1601 281 HIL-1602 281 HIL-1603 281 HIL-1650 281 Chapter 34 HLO System Messages HLO-1001 283 HLO-1002 283 HLO-1003 283 Chapter 35 HMON System - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 28
-1005 294 ICPD-1006 294 ICPD-1007 294 ICPD-1008 294 Chapter 40 IPAD System Messages IPAD-1000 297 IPAD-1001 297 Chapter 41 IPS System Messages IPS-1001 299 IPS-1002 299 IPS-1003 299 IPS-1004 299 IPS-1005 300 IPS-1006 300 Chapter 42 ISCS System Messages ISCS-1000 301 Chapter 43 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 29
Chapter 44 KSWD System Messages KSWD-1003 307 Chapter 45 KTRC System Messages KTRC-1001 309 KTRC-1002 309 KTRC-1003 309 KTRC-1004 309 KTRC-1005 310 Chapter 46 LOG System Messages LOG-1000 311 LOG-1001 311 LOG-1002 311 LOG-1003 312 Chapter 47 LSDB System Messages LSDB-1001 313 LSDB- - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 30
MS-1003 322 MS-1004 322 MS-1005 323 MS-1006 323 MS-1008 323 MS-1009 324 MS-1021 324 MS-1022 324 MS-1023 325 MS-1024 325 Chapter 52 NBFS System Messages NBFS-1001 327 NBFS-1002 327 NBFS-1003 328 Chapter 53 NS System Messages NS-1001 329 NS-1002 329 NS-1003 329 NS-1004 330 NS-1005 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 31
PDTR-1002 339 Chapter 56 PLAT System Messages PLAT-1000 341 PLAT-1001 341 PLAT-1002 341 PLAT-1003 342 Chapter 57 PORT System Messages PORT-1003 343 PORT-1004 343 PORT-1005 343 Chapter 58 PS System Messages PS-1000 345 PS-1001 345 PS-1002 345 PS-1003 345 PS-1004 346 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 32
Chapter 60 RAS System Messages RAS-1001 349 RAS-1002 349 RAS-1004 349 RAS-1005 349 RAS-1006 350 RAS-2001 350 RAS-2002 350 RAS-2003 350 RAS-3001 351 RAS-3002 351 RAS-3003 351 RAS-3004 351 Chapter 61 RCS System Messages RCS-1001 353 RCS-1002 353 RCS-1003 353 RCS-1004 354 RCS-1005 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 33
Chapter 64 SAS System Messages SAS-1001 361 Chapter 65 SCN System Messages SCN-1001 363 Chapter 66 SEC System Messages SEC-1001 365 SEC-1002 365 SEC-1003 366 SEC-1005 366 SEC-1006 366 SEC-1007 367 SEC-1008 367 SEC-1009 367 SEC-1016 367 SEC-1022 368 SEC-1024 368 SEC-1025 368 SEC- - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 34
SEC-1046 374 SEC-1049 374 SEC-1050 374 SEC-1051 375 SEC-1052 375 SEC-1053 375 SEC-1054 376 SEC-1055 376 SEC-1056 376 SEC-1057 377 SEC-1059 377 SEC-1062 377 SEC-1063 377 SEC-1064 378 SEC-1065 378 SEC-1069 378 SEC-1071 378 SEC-1072 379 SEC-1073 379 SEC-1074 379 SEC-1075 379 SEC- - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 35
Fabric OS Message Reference 53-1000600-02 SEC-1092 384 SEC-1093 384 SEC-1094 385 SEC-1095 385 SEC-1096 385 SEC-1097 386 SEC-1098 386 SEC-1099 386 SEC-1100 386 SEC-1101 387 SEC-1102 387 SEC-1104 387 SEC-1105 388 SEC-1106 388 SEC-1107 388 SEC-1108 389 SEC-1110 389 SEC-1111 389 SEC- - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 36
SEC-1142 395 SEC-1145 395 SEC-1146 396 SEC-1153 396 SEC-1154 396 SEC-1155 397 SEC-1156 397 SEC-1157 397 SEC-1158 397 SEC-1159 398 SEC-1160 398 SEC-1163 398 SEC-1164 399 SEC-1165 399 SEC-1166 399 SEC-1167 399 SEC-1168 400 SEC-1170 400 SEC-1171 400 SEC-1172 401 SEC-1173 401 SEC- - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 37
Fabric OS Message Reference 53-1000600-02 SEC-1193 406 SEC-1194 406 SEC-1195 406 SEC-1196 407 SEC-1197 407 SEC-1198 407 SEC-1199 408 SEC-1200 408 SEC-1201 408 SEC-1202 409 SEC-1203 409 SEC-1250 409 SEC-1251 409 SEC-1253 410 SEC-1300 410 SEC-1301 410 SEC-1302 410 SEC-1303 411 SEC- - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 38
xxxviii SEC-1323 416 SEC-1324 417 SEC-1325 417 SEC-1326 417 SEC-1327 417 SEC-1328 418 SEC-1329 418 SEC-1330 418 SEC-1331 419 SEC-1332 419 Chapter 67 SNMP System Messages SNMP-1001 421 SNMP-1002 421 SNMP-1003 421 SNMP-1004 422 SNMP-1005 422 SNMP-1006 422 Chapter 68 SS System - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 39
SULB-1018 434 SULB-1020 434 SULB-1021 434 SULB-1022 435 SULB-1023 435 SULB-1024 435 SULB-1025 436 SULB-1026 436 SULB-1030 436 SULB-1031 436 SULB-1033 437 SULB-1034 437 SULB-1035 437 SULB-1036 438 SULB-1037 438 Chapter 70 SWCH System Messages SWCH-1001 439 SWCH-1002 439 SWCH-1003 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 40
SYSM-1002 445 SYSM-1003 445 SYSM-1004 446 SYSM-1005 446 SYSM-1006 446 SYSM-1007 446 Chapter 73 TRCE System Messages TRCE-1001 447 TRCE-1002 447 TRCE-1003 447 TRCE-1004 448 TRCE-1005 448 TRCE-1006 448 TRCE-1007 449 TRCE-1008 449 TRCE-1009 449 TRCE-1010 449 TRCE-1011 450 TRCE-1012 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 41
UCST-1007 457 UCST-1020 457 Chapter 77 UPTH System Messages UPTH-1001 459 Chapter 78 WEBD System Messages WEBD-1001 461 WEBD-1002 461 WEBD-1004 461 WEBD-1005 461 WEBD-1006 462 WEBD-1007 462 WEBD-1008 462 Chapter 79 ZOLB System Messages ZOLB-1001 463 Chapter 80 ZONE System Messages - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 42
ZONE-1027 471 ZONE-1028 471 ZONE-1029 471 ZONE-1030 472 ZONE-1031 472 ZONE-1032 472 ZONE-1033 472 ZONE-1034 473 ZONE-1035 473 ZONE-1036 473 ZONE-1037 474 ZONE-1038 474 ZONE-1039 474 ZONE-1040 474 ZONE-1041 475 ZONE-1042 475 ZONE-1043 475 ZONE-1044 475 ZONE-1045 476 ZONE-1046 476 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 43
Chapter 4 Chapter 5 Chapter 6 CONF-1022 483 AUDIT FW System Messages FW-3001 485 AUDIT HTTP System Messages HTTP-1002 487 HTTP-1003 487 AUDIT SEC System Messages SEC-3001 489 SEC-3002 489 SEC-3003 489 SEC-3004 490 SEC-3005 490 SEC-3006 490 SEC-3007 491 SEC-3008 491 SEC-3009 491 SEC- - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 44
Chapter 7 Chapter 8 SEC-3029 498 SEC-3030 498 SEC-3031 498 SEC-3032 499 SEC-3033 499 SEC-3034 499 SEC-3035 499 SEC-3036 500 SEC-3037 500 SEC-3038 500 SEC-3039 501 SEC-3040 501 SEC-3041 501 SEC-3044 501 SEC-3045 502 SEC-3046 502 SEC-3047 502 SEC-3048 502 SEC-3049 503 SEC-3050 503 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 45
Chapter 9 SULB-1023 515 SULB-1024 516 SULB-1026 516 SULB-1030 516 SULB-1031 517 SULB-1032 517 SULB-1033 517 SULB-1034 517 SULB-1035 518 SULB-1037 518 AUDIT ZONE System Messages ZONE-3001 519 ZONE-3002 519 ZONE-3003 519 ZONE-3004 520 ZONE-3005 520 ZONE-3006 520 ZONE-3007 521 ZONE- - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 46
xlvi Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 47
procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for 6.1.0, documenting all - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 48
4100, 4900, 5000, 7500, AP 7600 switches • Brocade 24000 director • Brocade 48000 director • FA4-16 blade • FC10-6 blade What's new in this document The following changes have been made since this document was last released: • Information - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 49
guide are presented in mixed lettercase: for example, switchShow. In actual examples, command lettercase is often all lowercase. Otherwise, this manual specifically notes those cases in which a command to Brocade and Fibre Channel, see the Brocade Glossary. For definitions of SAN-specific terms - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 50
for hardware, firmware, and software support, including product repairs and part ordering. To expedite your call, have the following information available: 1. General Information • Switch model • Switch operating system version • Error numbers and messages received • supportSave command output - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 51
on the bottom of the port side of the switch • Brocade 7600-On the bottom of the chassis • Brocade 48000-Inside the chassis next to the power supply bays • Brocade DCX-On the bottom right on the port side of the chassis 3. World Wide Name (WWN) Use the wwn command to display the switch WWN. • If you - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 52
lii Fabric OS Message Reference 53-1000640-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 53
guide supports Fabric OS v6.1.0 and documents system messages that can help you diagnose and fix problems with a switch or fabric. The messages are organized first by event type, reliability, availability, and serviceability 3 •Port Logs 4 System Error Message Logging The RASLog service generates - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 54
command. The sequence number is persistent across power cycles and switch reboots. • By default, the errDump and errShow commands support post-event audits and problem determination based on high-frequency events of certain types such as security violations, zoning configuration changes, firmware - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 55
running UNIX, Linux, or any other operating system that supports the standard syslogd functionality. Configuring for syslogd involves configuring the host, enabling syslogd on the Brocade model, and, optionally, setting the facility level. For the Brocade DCX, 24000 and 48000, each CP has a unique - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 56
events reported for each port. Refer to the Fabric OS Administrator's Guide for information on interpreting results of the portLogDump command. Port log functionality is completely separate from the system message log. Port logs are typically used to troubleshoot device connections. Viewing and - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 57
the portLogEventShow command. portLogTypeEnable Enables an event to report to the port log. Port log events are described by the portLogEventShow command. setVerbose Sets the verbose level of a particular module within the Fabric OS. supportFtp Sets, clears, or displays support FTP parameters - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 58
System Parameters and Logs (Continued) Command Description supportFfdc Enables and disables FFDC (first failure data commands. This output is used by your switch service provider to diagnose and correct problems with the switch. The output from this command is very long. syslogDIpAdd Adds an IP - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 59
Media 27: Port media incompatible e. Reason: Configured port speed. Type to continue, Q to stop: Clearing the System Message Log To clear the system message log for a particular switch instance: 1. Log in to the switch as admin. 2. Use the errClear command to clear all messages from memory - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 60
1 Reading a RAS System Message 2. Verify the configuration: switch:admin> auditcfg --show Audit filter is enabled. 1-ZONE 2-SECURITY 3-CONFIGURATION 4-FIRMWARE 5-FABRIC 3. Enable the audit feature: switch:admin> auditcfg --enable Audit filter is enabled. 4. Configure up to six syslog servers to - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 61
command. The sequence number is persistent across power cycles and switch a security issue and additional FFDC problem determination. Audit event message format: AUDIT, , [], , , ////. / - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 62
, , Incorrect password during login attempt switch. The RASLog subsystem will support an internationalized timestamp format base Firmware Fabric User ID The user ID. Role The role of the user ID. IP Address The IP command to name the chassis or the switchName command to rename the logical switch - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 63
used as general guidelines for troubleshooting. For all cases, you in redundant mode unless the failed power supply is replaced or fixed. Problem 12 •Support 12 •Panic Dump and Core Dump Files 12 •Trace Dumps 13 •supportSave Command 13 Looking Up a System Message Error messages in this manual - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 64
enabled? 11. Are serial port (console) logs available? 12. Which CP was master? (only applicable to the Brocade DCX, 12000, 24000, or 48000) 13. What and when were the last actions or changes made to the system? Support Fabric OS creates a number of files that can help support personnel troubleshoot - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 65
using fewer physical ports. Access Gateway mode transforms the Brocade 200E as well as embedded switches into a device management tool that is compatible with different types of fabrics, including Brocade-, Cisco-, and McDATA-based fabrics. Authentication error messages indicate problems with the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 66
the domain and alias lists to all switches in the fabric. Fabric OS system driver module. Firmware blade compatibility errors with control processor (CP). Fibre Channel over IP port configuration messages. Fibre Channel miscellaneous messages relate to problems with the physical layer used to send - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 67
a service. A component is a module in Fabric OS implementing a related set of functionality. A service is switch wide, but also fabric wide. It keeps track iSCSI VT status and updates VT status to BP. System messages generated by the IP admin demon. Fibre Channel over IP license, tunneling, and port - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 68
(evmd) • Exchange Service Support daemon (essd) • FA-API rpc daemon (rpcd) • Fabric daemon (fabricd) • Fabric Watch daemon (fwd) • FCPD daemon (fcpd) • FDMI daemon (fdmid) • FICON CUP daemon (ficud) • FSPF daemon (fspfd) • Inter-fabric Routing daemon (iswitchd) • IP port - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 69
This message indicates hardware problems. PORT error messages refer to the front-end user ports on the switch. Front-end user ports are directly accessible action. If a switch is not responding, RTWR retries 100 times. Storage application services supporting director-class storage virtualization - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 70
station. Brocade switches support six management entities that can be configured to receive these traps. The supportSave command generates these error messages if problems are encountered. The software upgrade library provides firmwareDownload command capability, which enables firmware upgrades to - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 71
RASLog Messages Section I This section provides the RASLog messages, including: •AG System Messages 23 •AUTH System Messages 31 •BKSW System Messages 45 •BL System Messages 47 •BLL System Messages 61 •BM System Messages 63 •C2 System Messages 69 •CDR System Messages 71 •CER System Messages - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 72
Messages 291 •ICPD System Messages 293 •IPAD System Messages 297 •IPS System Messages 299 •ISCS System Messages 301 •ISNS System Messages 303 System Messages 331 •PDTR System Messages 339 •PLAT System Messages 341 •PORT System Messages 343 •PS System Messages 345 •PSWP System Messages 347 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 73
DRAFT: BROCADE CONFIDENTIAL •TRCK System Messages 451 •TS System Messages 453 •UCST System Messages 457 •UPTH System Messages 459 •WEBD System Messages 461 •ZOLB System Messages 463 •ZONE System Messages 465 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 74
- HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 75
command. • Some blades and ports in a switch may not support NPIV. NPIV functionality cannot be enabled on such ports and they will not respond to NPIV requests. Refer to the Access Gateway Administrator Guide, Appendix B for specific AG compatibility requirements. • On non-Brocade switches, refer - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 76
run the supportSave command and contact your switch service provider. Severity Access Gateway mode has been enabled or disabled. Recommended Please run port> connected to the fabric. Indicates that the N_Port connected to the fabric switch is not online. The specified N_Port has been disabled. 24 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 77
name>, Invalid port login (PLOGI) response from the fabric on the N_Port . Probable Cause Indicates that the fabric switch management server up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING AG-1009 Message , - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 78
port>. Probable Cause Failure sending N_Port logout request from the Access Gateway to the fabric switch. Recommended Action Please check the configuration of the fabric switch transfers; then run the supportSave command and contact your switch service provider. Severity WARNING AG-1013 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 79
set up automatic FTP transfers; then run the supportsave command and contact your switch service provider. Severity WARNING AG-1016 Message , [ display the status of all ports in the system. Run portCfgShow to display a list of Action ports currently configured as N_Port(s). Severity - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 80
the ag --mapshow command to display the updated F_Port to N_Port mapping. Action Severity INFO AG-1021 Message , [AG-1021], ,, WARNING, , Unable to do Preferred-Failover of F_Port . Failover across different fabric is not supported. Probable Cause - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 81
Area assigned to the attached F_Ports on edge switch is the same. Recommended Please run the porttrunkarea --show command on the attached switch to display that the TA is Action assigned to all ports in the system and run porttrunkarea --enable to reconfigure the TA. Severity ERROR Fabric OS - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 82
run the supportSave command and contact your switch service provider. Severity WARNING AG-1027 Message , [AG-1027], ,, WARNING, , Unable to handle this login request on port because NPIV capability is not enabled on this port. Probable Cause NPIV - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 83
. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1003 Message , [AUTH-1003], ,, INFO, , type has been successfully set to - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 84
; then run the supportSave command and contact your switch service provider. Severity WARNING AUTH-1007 Message Probable Cause , [AUTH-1007], ,, ERROR, , The proposed authentication protocol(s) are not supported: port . Indicates that the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 85
Cause Indicates an internal problem with the Secure Fabric OS. Recommended Action Reboot or power cycle the switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 86
run the supportSave command and contact your switch service provider. Severity WARNING AUTH-1014 Message , [AUTH-1014], , FFDC, ERROR, , Invalid port value to : port . Probable Cause Indicates an internal problem with the Secure - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 87
then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1018 Message , [AUTH-1018], ,, ERROR, , Invalid value to check protocol type: port . Probable Cause Indicates an internal problem with the Secure - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 88
transfers; then run the supportSave command and contact your switch service provider. Severity INFO AUTH-1022 port . Probable Cause Indicates that the authentication process failed to extract a particular value from the receiving payload. Recommended Action Usually this problem - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 89
; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH- port . Probable Cause Indicates that the authentication failed to get device or host bus adaptor (HBA) information due to an internal failure. Recommended Action Usually this problem - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 90
. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1028 Message , [AUTH-1028], ,, ERROR, , Failed to allocate - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 91
FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1033 Message , [AUTH-1033], ,, ERROR, , Disable port due to unauthorized switch . Fabric OS Message Reference - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 92
up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1035 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 93
run the supportSave command and contact your switch service provider. Severity switch has conflicting authentication policy: Port disabled. Indicates that the neighboring switch has a conflicting authentication policy enabled. The_E-Port has been disabled, because the neighboring switch - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 94
authentication. Recommended Action If there is no light on the port, correct the switch policy configuration on either of the switches using the authUtil command, and then enable the port on the neighboring switch using the portEnable command. If the E_Port formed, no action is required. Severity - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 95
. This problem may be transient due to the system's central processing unit (CPU) load. In addition, a defective small form-factor pluggable (SFP) or faulty cable may have caused the failure. Recommended Check the SFP and the cable. Then try to enable the port using the portEnable command. Action - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 96
3 AUTH-1044 44 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 97
daemons is found to be nonresponsive; sending signal abort. Recommended Action Run the supportSave command to determine if any core files were created. If a core file is found, information, and contact your switch service provider. Severity WARNING Fabric OS Message Reference 45 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 98
4 BKSW-1003 46 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 99
does not have hardware problems. Note that any reference seen to slot 0 is a reference to the blade within the switch platform, e.g.,Brocade 7500 and AP7600 contain FR4-18i and FA4-18 blades respectively. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 100
to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the blade. Severity CRITICAL BL-1006 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 101
to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the blade. Severity CRITICAL BL-1009 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 102
port. Run the systemVerification command to verify that the blade or switch does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot or power - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 103
cable, small form-factor pluggable (SFP), or device attached to the specified port. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot or power cycle the switch. If the message persists, replace the blade. Severity ERROR BL-1014 Message Probable - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 104
if there is a hardware error. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors are encountered again: • On the Brocade DCX, 24000, and 48000, replace the blade field - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 105
problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands Cause Indicates that the slot has completed initializing the ports. Recommended No action is required. Action Severity INFO BL - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 106
of the internal ports was not online. The switch is faulted. Recommended Action Reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 107
Virtualization ports on the blade in slot will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all GigE/Fibre Channel over IP (FCIP - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 108
power cycle the switch. If the message persists, replace the switch. Severity CRITICAL BL-1029 Message , [BL-1029], ,, INFO, , All ports on the switch will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 109
/FC Fastwrite ports on the switch will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all the GigE/Fibre Channel over IP (FCIP - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 110
messages from the user ports after disabling the ports. Recommended Action Reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If the message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 111
-number>,, CRITICAL, , Faulting chip in slot = , miniS = ,port = due to BE/BI port fault. Probable Cause Fault the chip and disable all the ports on that chip. Recommended No action is required. Action Severity CRITICAL Fabric OS Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 112
5 BL-1037 60 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 113
Message , [BLL-1000], , FFDC, CRITICAL, , ASIC driver detected Slot port as faulty (reason: ) Probable Cause Indicates that a blade regulation problem was reported on the specified slot number. The blade is faulted. The - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 114
6 BLL-1000 If the message persists, replace the blade. Severity CRITICAL 62 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 115
blade. Recommended Action The problem can be corrected by changing the firmware version on either the control processor ( firmware version on the CP blade can be changed using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmware download is supported - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 116
for the blade in the specified slot. Recommended Use the slotPowerOff and slotPowerOn commands or reseat the affected blade. On the Brocade Action DCX, 7500 or 7600, switch off and on all primary power in order to power-cycle the unit. Severity WARNING BM-1006 Message , [BM-1006 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 117
firmwaredownload to recover. Probable Cause The automatic firmware upgrade on the blade has failed because the blade firmware version was detected to be different from the control processor (CP) firmware version. Recommended Issue the firmwareDownload command to recover the blade. Action Severity - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 118
On the Brocade 7500 or 7600, switch off and on all primary power to power-cycle the unit. Action Severity WARNING BM-1054 Message , [BM-1054], ,, INFO, , AP firmware is not consistent with system firmware . Auto-leveling - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 119
Configure the switch to persistently enable all ports. Action Severity INFO BM-1058 Message , [BM-1058], ,, WARNING, , Download of AP firmware failed for the switch. Reissue firmwaredownload to recover. Probable Cause The automatic firmware upgrade on - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 120
7 BM-1058 68 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 121
, Port port fault (the configured speed may not be supported by the SFP). Port chip faulted due to an internal error. Probable Cause Internal error. All the ports on the blade/switch at the next maintenance window. If the problem Action persists, replace the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 122
on S() user port because QoS license is not present. Probable Cause Indicates that the switch does not have the QoS license added. Rate Limit is a licensed feature and requires QoS license. Recommended Add QoS license to the switch to enable the Rate Limit functionality - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 123
Port chip faulted due to internal error. Probable Cause Internal error. Recommended For a bladed system, issue the slotPowerOff and slotPowerOn commands on the blade to recover Action the system. For a non-bladed system, perform fastBoot on the switch window. If the problem Action persists - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 124
in the application specific integrated circuit (ASIC) hardware that may degrade data traffic. Recommended Whenever this error occurs, reboot the system at the next maintenance window. If the problem Action persists, replace the blade. Severity ERROR 72 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 125
loaded on the standby CP. The standby CP does not support the Advanced Performance Tuning module when the fibre connectivity (FICON) Management Server is enabled. Recommended Action Run the firmwareDownload command to upgrade the firmware on the standby CP. You can also disable FMS on the active - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 126
10 CER-1001 74 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 127
completed successfully. The message string that follows is the description of the class of configuration parameters that were uploaded. If AD is enabled, the AD number is specified in the description. Recommended No action is required. Action Severity INFO CONF-1020 Message , [CONF - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 128
switch and try to download configuration again. Action Severity INFO CONF-1030 Message , [CONF-1030], ,, WARNING, , Configuration database full, data not committed (key:. Probable Cause Previous configuration commands - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 129
of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Run the fanShow command to is faulted. Recommended Action On Brocade 24000 and 48000, try reseating the specified FRU. Reboot or power cycle the switch. Fabric OS Message Reference 77 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 130
and an optional number to identify the unit, slot, or port. The Brocade 3250 has one power supply and three fans, and the Brocade 3850 has two power supplies and four fans. Values for the individual fans and power supplies for these switches might display, but these parts cannot be replaced: the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 131
or the switch for nonbladed switches. Recommended Action There is most likely a voltage hardware problem on the blade or motherboard of the switch. For the Brocade DCX, 24000 -number>, FFDC, CRITICAL, , powered down unexpectedly. Fabric OS Message Reference 79 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 132
. The specific failed target state is displayed in the message. There are serious internal Fabric OS configuration or hardware problems on the switch. Recommended Action On Brocade DCX, 24000 and 48000, try reseating the indicated field-replaceable unit (FRU). If the message persists, reboot or - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 133
Action If you ran the fruInfoSet command, try the command again; otherwise, the update is problem was discovered when performing consistency checks during a warm boot. Recommended Monitor the switch. If the problem persists, a reBoot or power cycle is required to resolve the Action problem - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 134
that a problem was discovered when performing consistency checks during a cold boot. Recommended Action Monitor the switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 135
to 1 with the chassisConfig command, or upgrade the Action firmware on the standby to the version problem. The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or port. Recommended Action If the message persists, reboot or power cycle the switch - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 136
, or completely screw in the upper thumbscrew for the FC4-48 port blade) if the field-replaceable unit (FRU) is intended for use. Refer to the appropriate hardware manual for instructions on inserting the switch blades. Severity ERROR EM-1033 Message , [EM-1033], - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 137
-wide name (WWN) card, then default WWN and IP addresses are used for the switch. Recommended Action Reseat the FRU card. If the message persists, reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 138
or off. Recommended The specified FRU is not responding to commands and should be replaced. Action Severity WARNING EM-1044 Message , [EM-1044], ,, WARNING, , Can't power on , its logical switch is shut down 86 Fabric OS Message Reference 53 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 139
be powered on because the associated logical switch is shut down. Recommended Run the switchStart command on the associated logical switch. power), a newly inserted port blade was not powered on because there was not enough power available. Recommended The Brocade 24000 requires only a single power - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 140
access to the field-replaceable unit (FRU) has become available again. Recommended The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is Action displayed. Severity INFO EM-1049 Message , [EM-1049], ,, INFO, , FRU - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 141
port speed. If the port media is extended long wavelength, move it to a port that can support port media is detected. The reason code for this message is for internal use only. This message is valid for only the Brocade blade is automatically reset due to known resetable transient errors, such as an - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 142
, Switch gets reset: Probable Cause The switch is automatically reset due to known resetable transient errors system is not supported by the release on the standby control processor (CP). Recommended Action Please remove all blades of this type or upgrade your standby CP - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 143
Blade: is being powered off (based on user configuration) upon receiving a HW ASIC ERROR, reason:. The blade is power off since a hardware (HW) application specific integrated circuit (ASIC) ERROR was detected, and the user has selected to power off the problem blade when such - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 144
either the control processor firmware (CFOS) or the blade processor firmware (BFOS) is not compatible with the Storage Application Services (SAS) or other application firmware version(s). Recommended Upgrade the FOS firmware or the SAS firmware with the firmwareDownload command. Refer to the Action - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 145
12 EM-2003 • Run the systemverification command to verify that the switch does not have hardware problems. Refer to theFabric OS Reference Manual for more information on this command. • On bladed systems, replace the specified FRU, otherwise replace the switch. Severity ERROR Fabric OS Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 146
12 EM-2003 94 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 147
Action Discontinue the firmware download, identify the downlevel switch or switches that do not support the Coordinated HotCode protocol, and upgrade the downlevel switches. Then, restart the firmware download on this switch. Note that upgrading a downlevel Brocade switch in a mixed interop - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 148
Cause During the Coordinated HotCode protocol, a switch in the fabric did not accept the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to this issue. Recommended No action is required. Action - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 149
id.> Probable Cause The event could not be sent to the remote proxy because the remote proxy switch cannot be reached through in-band. Recommended Please make sure that the specified remote domain is present in the fabric. Action Severity WARNING Fabric OS - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 150
14 EVMD-1001 98 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 151
Cause Indicates that an internal link service (ILS) information unit of invalid size has been received. The neighbor switch has sent an invalid sized payload. Recommended Action Investigate the neighbor switch for problems. Run the errShow command on the neighbor switch to view the error log for - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 152
command and contact your switch service provider. Severity WARNING FABR-1004 Message , [FABR-1004], ,, WARNING, , port: - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 153
problem with the Fabric OS. Recommended Action In case of severe memory corruption, the system might recover by performing an automatic failover. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 154
message is rare and usually indicates a problem with the Fabric OS. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity WARNING FABR-1011 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 155
port is disabled. Recommended Action Run the configShow command to view the fabric.ididmode. A 0 means the IDID mode is disabled; a 1 means it is enabled. Set the switch to insistent domain ID mode. This mode is set under the configure command or in Web Tools on the Switch Admin > configure window - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 156
1016 Message , [FABR-1016], ,, WARNING, , ficonMode is enabled. Probable Cause Indicates that FICON mode is enabled on the switch through a user interface command. Recommended No action is required. Action Severity WARNING FABR-1017 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 157
limit. Contact your switch provider to obtain a full fabric license. Severity CRITICAL FABR-1022 Message , [FABR-1022], , FFDC, CRITICAL, , Fabric size () exceeds supported configuration (). Fabric limit timer ( - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 158
fabric must be changed to within the licensed limit. Contact your switch provider to obtain a full fabric license. Severity INFO FABR-1029 Message Probable Cause , [FABR-1029], ,, INFO, , Port negotiated (mode - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 159
modes, the buffer credits are fixed, based on the port configuration information. In this mode, the service (ILS) to the iswitchd demon on the specified E_port. Recommended Run the top command switch with an unsupported Fabric OS version 2.x has joined the fabric. Recommended Remove the switch - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 160
Area. The user has to manually enable the port else the port remains disabled forever. Refer to the Admin Guide for more information. Severity INFO Trunk Area enabled port. Persistently disabling port . Probable Cause When port on Switch is Trunk Area enabled it does - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 161
present when F port trunking is enabled. Recommended Install trunking license or disable F port trunking over the port. Action Severity INFO FABR-1039 Message , [FABR-1039], , WARNING, , Invalid domain id zero received from principal switch (domain id - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 162
15 FABR-1039 110 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 163
by the software. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1004 Message , [FABS-1004], - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 164
an invalid value in an object's status field. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. 112 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 165
unknown event type. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1011 Message Probable Cause , [FABS-1011 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 166
problem. Recommended Action Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware inability to read the FRU header, or the blade may not be supported by this platform or Fabric OS version. Recommended Action Verify that the blade - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 167
specified FRU could not be enabled. This is usually an internal Fabric OS problem. Recommended Action Try removing and reinserting the FRU. Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. Severity ERROR Fabric OS Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 168
16 FABS-1015 116 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 169
Action The problem can be corrected by changing the version of firmware on the CP or AP blades. The firmware version on the CP blade can be changed using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmwareDownload is supported between the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 170
17 FBC-1001 118 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 171
sequence-number>, FFDC, ERROR, , of GE failed. Please retry the command. Data: inst= st= - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 172
18 FCIP-1001 120 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 173
is low on memory and failed to allocate new memory for an information unit (IU). Recommended A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will Action automatically fail over and the standby CP will become the active CP. Severity CRITICAL Fabric OS Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 174
19 FCMC-1001 122 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 175
device vendor for a firmware upgrade containing a defect fix. Severity WARNING FCPD-1003 Message , [FCPD-1003], ,, INFO, , Probing failed on which is possibly a private device which is not supported in this port type Probable Cause Private - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 176
20 FCPD-1003 124 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 177
CRITICAL, , : failed, out of memory condition Probable Cause Indicates that the switch is low on memory and failed to allocate new memory for a Fibre Channel driver instance. The function can only be " fc_create". This function creates a Fibre Channel - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 178
21 FCPH-1001 126 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 179
action is required. Action Severity INFO FCR-1003 Message , [FCR-1003], ,, INFO, ,FC router physical devices newly exported at port . Probable Cause Indicates that one or more physical devices have been newly exported through the specified - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 180
. Action Severity INFO FCR-1006 Message , [FCR-1006], ,, INFO, , FC router LSAN zone device added at port . Probable Cause Indicates that a device is added to a logical storage area network (LSAN) zone in the edge fabric. Recommended No - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 181
>,, INFO, , FC router LSAN zone enabled at port : . Probable Cause Indicates that a logical storage area network (LSAN) zone was enabled in the edge fabric attached to the specified port. The enabled LSAN zone configuration is listed. Recommended No action - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 182
port . Probable Cause Indicates that the fibre channel router has completed a fabric build at the specified port on port - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 183
to view how many proxy devices are created in the fabric with the port resource problem. LSAN zones are removed using standard zoning commands such as zoneShow, zoneRemove, zoneDelete, cfgDelete, and cfgDisable in the edge fabric. Proxy devices can be removed by zoning operations or by bringing - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 184
consumed. Recommended Remove the proxy device slots by using the fcrProxyConfig command or limit proxy devices by Action removing logical storage area network a translate domain (which limits the number of translate domain ports required) by limiting the devices specified in logical storage area - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 185
It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of logical storage area >,, INFO, , In slot port WWN roll over. Fabric OS Message Reference 133 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 186
port world-wide name (WWN) pool has rolled over in the specified slot, and WWN entries detected to not be in use are reused as needed. Recommended Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch be disabled then re-enabled. Severity INFO FCR-1028 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 187
No action is required. Action Severity INFO FCR-1032 Message , [FCR-1032], ,, INFO, , Edge fabric enabled security on port in fabric . Probable Cause Indicates that Secure mode was turned on in the edge fabric. Recommended No - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 188
in the backbone fabric. Probable Cause Indicates that the specified logical storage area network (LSAN) zone was enabled in the backbone fabric. The enabled LSAN zone configuration is listed. Recommended No action is required. Action Severity INFO FCR-1037 Message , [FCR-1037 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 189
: . Probable Cause Indicates that the number of cfg/zone/alias entries created in a local fabric is greater than the local switch's zone database limitations. Recommended Remove excess cfg/zone/alias entries so that the number of logical storage area network (LSAN) Action zones - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 190
contact your switch service provider. Severity ERROR FCR-1049 Message Probable Cause , [FCR-1049], ,, ERROR, , EX port () received an ELP command that is not supported. Indicates an incoming exchange link protocol (ELP) command was issued and - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 191
commands to enable and disable the port. If the problem persists contact your switch service provider. Severity ERROR FCR-1053 Message , [FCR-1053], ,, WARNING, , Port - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 192
routing is not needed. Otherwise replace the switch with Action one that supports backbone to edge routing. Severity INFO FCR- command to modify the appropriate parameters on the local switch. Run the appropriate configuration command to modify the switch or port parameters on the remote switch - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 193
commands to restart authentication. Severity INFO FCR-1060 Message , [FCR-1060], ,, WARNING, , EX_Port() has an incompatible configuration setting. Probable Cause Indicates that virtual channel (VC) Link Init is enabled on the local switch - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 194
of supported EX_ports or VEX_ports was exceeded. To enable the specified port, disable any other operational port then re-enable the port. Cause Indicates that the fabric ID of the switch does not match the local switch. Recommended Run the switchShow command to display the fabric ID. Change the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 195
manually re-enable the port. If there is another fabric with the same ID, change the fabric ID for the port using the portCfgExport or portCfgVExport commands the fcrState set to 2 (disabled). Note that the FC Routing service is disabled by the factory. Recommended No action is required. Action - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 196
set to 1 (enabled). Note that the FC Routing service is disabled by the factory. Recommended No action is required. Action Severity INFO FCR-1070 Message , [FCR-1070], ,, INFO, , The FC Routing configuration is set to default. Probable Cause Indicates - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 197
Probable Cause Indicates that a switch in the backbone/edge that supports different limit of logical storage area network (LSAN) zones was detected. Recommended Action Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find the lowest supported LSAN zone limits. Please - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 198
re-enable the port. Recommended Make sure to remain within the maximum of supported front domains. Action Severity ERROR FCR-1077 Message , [FCR-1077], ,, WARNING, , Port rejected fabric binding request/check from the M-Model switch; - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 199
Cause During the Coordinated HotCode protocol, a switch in the fabric did not accept the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to this issue. Recommended Action Severity WARNING Fabric OS - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 200
Cause During the Coordinated HotCode protocol, a switch in the fabric did not accept the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to this issue. Recommended Action Severity WARNING 148 Fabric - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 201
: This is a 1 byte hexidecimal value that represents the domain of the switch that the FICON Channel is directly connected to. HP - Host Port number: This is a 1 byte hexidecimal value that represents the switch port of the switch that the FICON Channel is directly connected to. DD - Device Domain - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 202
Block ID Emulation Enabled or Disabled>. Probable Cause User changed the configuration manually. Recommended No action is required. Action Severity INFO FICN-1006 Message , [FICN-1006], ,, WARNING, , FICON GEPort < 0 or 1 - GE port number> TID - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 203
Probable Cause Unit Check status received from device and a sense command was issued to read the sense data. Recommended If there was a job failure associated with this event, please contact your vendor's customer support Action for assistance. Severity INFO FICN-1010 Message , [FICN - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 204
Recommended If there was an XRC volume or session suspended associated with this event, please contact your Action vendor's customer support for assistance. Severity ERROR FICN-1012 Message , [FICN-1012], ,, ERROR, , DevDiskIng:Device level exception found - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 205
with an invalid LRC. This indicates data corruption between the emulation processing components. Recommended Please contact your vendor's customer support for assistance. Action Severity ERROR FICN-1016 Message , [FICN-1016], ,, INFO, , DevIng:Received - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 206
with this event, please contact your vendor's Action customer support for assistance. Severity ERROR FICN-1022 Message , [ 4 status values received from the device> cmdArray=0x tflags=0x - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 207
Path=. Probable Cause The FICON channel issued a Purge Path command sequence for a device. Recommended If there was an unexpected job failure or IO Error associated with this event, please contact your Action vendor's customer support for assistance. Severity ERROR FICN-1025 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 208
associated with this event, please contact your Action vendor's customer support for assistance. Severity ERROR FICN-1029 Message Probable Cause < LastCmds=0x LastStatus=0x - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 209
Error associated with this event, please contact your Action vendor's customer support for assistance. Severity ERROR FICN-1031 Message , [FICN-1031 Control Unit has accepted a logical path establishment command sequence with the FICON channel. Fabric OS Message Reference 157 53-1000600 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 210
support for assistance. Action Severity ERROR FICN-1035 Message , [FICN-1035], ,, WARNING, , HostIng:FICON System Reset received on Path=. Probable Cause A locally connected FICON channel issued connected FICON Channel issued a Remove Logical - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 211
connected FICON Channel issued an Establish Logical Path Unit. Recommended Please contact your vendor's customer support for assistance. Action Severity ERROR FICN-1040 Message Data Rcvd:Path= LastCmds=0x SenseData:Bytes0- - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 212
Reject (LRJ) from CU Rx Path= LastCmd=0x LastStatus=0x - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 213
this was an unexpected event, please contact your vendor's customer support for assistance. Action Severity ERROR FICN-1045 Message , name>, HostTapeIng:LRJ received on Path= lastCmds=0x lastStatus=0x - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 214
This is an unexpected event, please contact your vendor's customer support for assistance. Action Severity WARNING FICN-1051 Message Probable Cause < Assigned Session ID>, Path=. An establish XRC session PSF command has been received to initiate an XRC session with the extended DASD - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 215
this was an unexpected event, please contact your vendor's customer support for assistance. Action Severity INFO FICN-1053 Message , [FICN >, Path=. Probable Cause A withdraw from XRC session PSF command has been received to break an XRC session with the extended DASD - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 216
command has been received to break an XRC session with the extended DASD device. Recommended If this was an unexpected event, please contact your vendor's customer support an unexpected event, please contact your vendor's customer support for assistance. Action Severity ERROR FICN-1058 Message < - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 217
: Path=. Probable Cause An internal issue has been encountered in the removal of an existing fast path hash table entry. Recommended This is an unexpected event, please contact your vendor's customer support for assistance. Action Severity ERROR FICN-1062 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 218
0x. Probable Cause An abort operation has been received from a peer FC interface for an exchange. Recommended If there were associated IO errors at the same time as this event, please contact your vendor's Action customer support for assistance. Severity INFO - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 219
there is an internal memory leak, please contact your vendor's customer support for assistance. Severity WARNING FICN-1067 Message , [FICN-1067], issue. Recommended If resolution of the configuration issue cannot be completed, please contact your vendor's Action customer support for - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 220
error messages with this event, please contact your vendor's customer support for assistance. Severity INFO FICN-1071 Message , [FICN-1071 Path=:states=0x:cmds=0x:status=0x - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 221
>:Emuls=0x:Cmds=0x:Chains=0x:MBytes= - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 222
>:Emuls=0x:Cmds=0x:Chains=0x:MBytes= - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 223
number of emulated host read commands processed while this tape Port Host> Port=0x. Probable Cause An attached port which had an FICON emulated path established has logged out from the switch. Recommended This may be an unexpected event, please contact your vendor's customer support - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 224
23 FICN-1084 Probable Cause An attached port with the established FICON emulated path has logged out from the switch. Recommended This may be an unexpected event, please contact your vendor's customer support for assistance. Action Severity WARNING FICN-1084 Message , [FICN-1084], < - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 225
Action If this is a bladed switch, execute the haFailover command. If the problem persists, or if this is a nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference for more information on this command. Severity ERROR FICU-1003 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 226
module within the fibre connectivity control unit port (FICON-CUP) daemon failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference for more information on this command. Severity ERROR FICU-1006 Message Probable Cause - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 227
then run the supportSave command and contact your switch service provider. Severity WARNING FICU-1008 Message , [FICU-1008], ,, WARNING, , FMS mode has been enabled. Port(s): have been disabled due to port address conflict. Probable Cause - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 228
FICON Management Server mode (fmsMode) was not enabled because the specified port has an address conflict with the CUP management port is in use. Recommended Use the portDisable command to disable the specified port to avoid the port address conflict. Action Severity WARNING 176 Fabric OS - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 229
WARNING, , exchange overlapped, pid= Probable Cause Indicates that the FC kernel driver has timed out the exchange while the application is still active. When the FC kernel driver reuses the exchange, the application will overlap. This happens on a timed-out exchange; it - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 230
25 FKLB-1001 178 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 231
, FFDC, WARNING, , Unknown LSR type: port , type Probable Cause Indicates that the link can support. Recommended Reduce the number of switches in the fabric or reduce the number of redundant ISLs between two Action switches. Severity - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 232
26 FLOD-1006 Probable Cause Indicates that the received LSR contained an invalid domain number. Recommended No action is required; the LSR is discarded. Action Severity WARNING FLOD-1006 Message , [FLOD-1006], ,, WARNING, , Transmitting invalid domain ID: - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 233
Message , [FSPF-1001], ,, ERROR, , Input Port out of range Probable Cause Indicates that the specified input port number is out of range; it does not exist on the switch. Recommended No action is required. Action Severity ERROR FSPF-1002 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 234
than 0 is incompatible in a fabric of Brocade switches. Disconnect the offending switch. Severity ERROR FSPF-1006 Message , [FSPF-1006], ,, ERROR, , FSPF Version not supported, input port = Probable Cause Indicates that the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 235
. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FSS-1002 Message , [FSS-1002], ,, WARNING, , Component ( - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 236
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity WARNING FSS-1006 Message , [FSS-1006], ,, WARNING, , No FSS message available - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 237
ifconfig eth1 (as root) or run supportShow/supportSave to validate the network configuration; then try to restore the synchronization by issuing the haSyncStart command. If the problem persists, contact your switch service provider. Severity CRITICAL Fabric OS Message Reference 185 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 238
28 FSS-1007 186 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 239
running the switchReboot command), then no action is required. Otherwise, issue the haSyncStart command on the command to diagnose the problem. If the problem persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 240
current running version. This cause a disruptive firmware upgrade/downgrade. Recommended For a dual CP system, run the firmwareDownload command to load compatible firmware on the Action standby CP. For details on this command, refer to the Fabric OS Command Reference. Severity INFO 188 Fabric OS - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 241
Value> . Probable Cause Indicates that the internal temperature of the switch has changed. Recommended Action No action is required. Respond to this message range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Severity WARNING - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 242
> . Probable Cause Indicates that the internal temperature of the switch has changed from a value outside of the acceptable range to a that the speed of the fan has changed. Fan problems typically contribute to temperature problems. Recommended Action No action is required. Respond to this - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 243
boundary, verify that it is seated correctly in the chassis. Run the psShow command to view the status of the power supply. If the power supply continues to be a problem, replace the faulty power supply. Severity INFO FW-1010 Message Probable Cause , [FW-1010], - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 244
supply correctly and that it is correctly seated in the Action chassis. If the problem persists, replace the faulty power supply. Severity WARNING FW-1011 Message , [FW-1011], ,, INFO, , , is above high boundary(High=, Low= - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 245
, , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) has changed. The receive performance area measures the amount of incoming laser to help you - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 246
name>, , is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) has fallen below the low boundary. The receive performance area measures the amount of incoming - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 247
Label>, is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the transmit power value of the small form-factor pluggable (SFP) has fallen below the low boundary. The transmit performance area measures the amount of outgoing laser - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 248
is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the transmit power value of the small form-factor pluggable (SFP) has changed from a value outside of the acceptable range to a value within the acceptable range - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 249
30 FW-1048 Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high boundary. The supplied current of the SFP transceiver is outside of the normal range, indicating possible hardware failure. Recommended If the current rises above the high - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 250
30 FW-1051 FW-1051 Message , [FW-1051], ,, WARNING, , , is above high boundary(High=, Low=). Current value is . Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has risen - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 251
SFP failures also cause E_Ports to go down. E_Port downs might be caused by transient errors. A low number of E_Port failures means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 252
fabric reconfiguration might be a transient error and might not require troubleshooting. Severity INFO FW-1118 Message , [FW-1118], < boundary. The following occurrences can cause a fabric reconfiguration: • Two switches with the same domain ID have connected to one another. • Two - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 253
changes has changed. Domain ID changes occur when there is a conflict of domain IDs in a single fabric and the principal switch has to assign another domain ID to the switch. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 254
occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. Recommended No action is required - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 255
occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. A low number of segmentation errors - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 256
30 FW-1129 • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. Recommended No action is required. - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 257
Current value is . Probable Cause Indicates that the number of fabric logins has fallen below the low boundary. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric login or FLOGI. A low number of fabric logins means that the fabric is - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 258
number of fabric logins has changed from a value outside of the acceptable range to a value within the acceptable range. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric login or FLOGI. Recommended No action is required. Respond to this message as - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 259
changes means that the switch is functioning normally. Recommended , , , , value problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 260
failures that the port experiences has fallen problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. A low number of link loss errors means that the switch - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 261
. If you continue to experience synchronization loss errors, troubleshoot your host bus adaptor (HBA) and contact your switch service provider. Severity INFO FW-1165 Message , [FW-1165], ,, INFO, , , , is below low boundary(High= - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 262
troubleshoot your host bus adaptor (HBA) and contact your switch service provider. Severity WARNING FW-1167 Message , [FW-1167], ,, INFO, , - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 263
the switch is functioning normally. Severity INFO FW-1170 Message , [FW-1170], ,, WARNING, , - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 264
Probable Cause Indicates that the number of protocol errors that the port experiences has fallen below the low boundary. Occasional protocol errors occur protocol errors occur due to hardware problems. A low number of protocol errors means that the switch is functioning normally. Recommended No - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 265
that the number of invalid words that the port experiences has changed. Invalid words usually indicate a hardware problem with an small form-factor pluggable (SFP a hardware problem with an small form-factor pluggable (SFP) or cable. A low number of invalid words means that the switch is functioning - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 266
Probable Cause Indicates that the number of invalid words that the port experiences has changed from a value outside of the acceptable range to a value within the acceptable range. Invalid words usually indicate a hardware problem with an small form-factor pluggable (SFP) or cable. Recommended No - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 267
High=, Low=). Current value is . Probable Cause Indicates that the percentage of incoming traffic that the port experiences has changed. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 268
(High=, Low=). Current value is . Probable Cause Indicates that the percentage of incoming traffic that the port experiences has risen above the high boundary. Recommended No action is required. Respond to this message as is appropriate to the particular policy - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 269
has gone offline, has come online, is testing, is faulty, has become an E_Port, has become an F_Port, has segmented, or has become a trunk port. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 270
, is testing, is faulty, has become an E_Port, has become an F_Port, has segmented, or has become a trunk port. A low number of port state changes means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 271
set your high boundaries to five- or six-digit figures, as only large numbers of messages indicate a problem in this area. A low level of invalid CRC errors means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 272
fluctuations, and aging equipment. You should set your high boundaries to five- or six-digit figures, as only large numbers of messages indicate a problem in this area. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 273
30 FW-1242 Probable Cause Indicates that the number of end-to-end (EE) cyclic redundancy check (CRC) errors has fallen below the low boundary. Invalid CRC messages occur when the number of CRC errors in Fibre Channel frames for specific source ID (S_ID) and destination ID (D_ID) pairs change. - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 274
value>, Low=). Current value is . Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch receives has fallen below the low boundary. Receive performance messages appear due to the number of word frames that travel from the configured S_ID - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 275
High value>, Low=). Current value is . Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch transmits has changed. Transmit performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 276
that the number of end-to-end (EE) word frames that the switch transmits has changed from a value outside of the acceptable range to a value boundary. The port has received a small computer system interface (SCSI) Read, SCSI Write, SCSI Read and Write, SCSI Traffic, or IP commands in a frame - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 277
range. The port has received a small computer system interface (SCSI) Read, SCSI Write, SCSI Read and Write, SCSI Traffic, or IP commands in a IP) addresses that are authorized to establish Telnet connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 278
address. The TELNET_POLICY contains a list of internet protocol (IP) addresses that are authorized to establish Telnet connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 279
address. The HTTP_POLICY contains a list of internet protocol (IP) addresses that are authorized to establish browser connections to the switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 280
network management protocol policy (SNMP_POLICY) contains a list of internet protocol (IP) addresses that are authorized to establish API connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 281
network management protocol policy (SNMP_POLICY) contains a list of internet protocol (IP) addresses that are authorized to establish API connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 282
high boundary. RSNMP violations indicate that an SNMP "get" operation request has been received from an unauthorized IP address. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 283
. WSNMP violations indicate that an SNMP "get/set" operation request has been received from an unauthorized IP address. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 284
device ports that are allowed to access the SES Server functionality. Recommended Action Run the errShow command to determine the IP address that violations indicate that an small computer system interface (SCSI) Enclosure Services (SES) request has been received from an unauthorized world-wide - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 285
violations indicate that an small computer system interface (SCSI) Enclosure Services (SES) request has been received from an unauthorized world-wide name of device ports that are allowed to access the Management Server functionality. Recommended Action Run the errShow command to determine the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 286
has changed. Serial violations indicate that an unauthorized serial port request has been received. The SERIAL_POLICY contains a list of switch world-wide names (WWNs) for which serial port access is enabled. Recommended Action Run the errShow command to determine the WWN of the device that sent - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 287
high boundary. Serial violations indicate that an unauthorized serial port request has been received. The SERIAL_POLICY contains a list of switch world-wide names (WWNs) for which serial port access is enabled. Recommended Action Run the errShow command to determine the WWN of the device that sent - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 288
that an unauthorized front panel request has been received. The FRONTPANEL_POLICY contains a list of switch world-wide names (WWNs) for which front panel access is enabled. Recommended Action Run the errShow command to determine the WWN of the device that sent the request. Responses to security - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 289
a list of switch world-wide names (WWNs) for which front panel access is enabled. Recommended No action switch tried to join the fabric. The SCC_POLICY contains a list of switches by world-wide name (WWN) that are allowed to be members of a fabric. Recommended Action Run the errShow command - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 290
private loop devices not performing FLOGI is done through the name server. Recommended Action Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 291
private loop devices not performing FLOGI is done through the name server. Recommended Action Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 292
the specification of rules for binding device ports (typically host bus adaptor (HBA) ports) to specific switch ports. DCC policies ensure that whenever a device has been detected. Recommended Action Run the errShow command to determine the IP location of the login attempt. Responses to security - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 293
FW-1343 Recommended Action Run the errShow command to determine the IP location of the login attempt. Responses to primary FCS downloads a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its current time. If - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 294
world-wide name (WWN). When the primary fabric configuration server (FCS) downloads a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its current time. If the difference is too great, it rejects the packet - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 295
in the fabric, the packet is signed using the private key of the primary FCS. The receiving switch has to verify this signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This counter keeps track of the number of packets received with invalid - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 296
in the fabric, the packet is signed using the private key of the primary FCS. The receiving switch has to verify this signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This counter keeps track of the number of packets received with invalid - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 297
in the fabric, it first sends its certificate to all the switches in the fabric. The receiving switch has to verify that the sender is the primary FCS switch and its certificate is signed by the Root CA recognized by the receiving switch. This counter keeps track of the number of packets received - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 298
the low boundary. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the number - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 299
the acceptable range. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 300
value is . Probable Cause Indicates that the number of switch link authentication protocol (SLAP) faulty packets has risen above the high . Probable Cause Indicates that the number of time service (TS) out-of-sync violations has changed. Recommended Responses to - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 301
Current value is . Probable Cause Indicates that the number of time service (TS) out-of-sync violations has changed from a value outside of the acceptable fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 302
finds that there are no FCSs in the fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS to all zeroes. Recommended Responses to security-class messages depend on user policies. - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 303
loses contact with the primary fabric configuration server (FCS) switch. When the primary FCS switch in the fabric sends its certificate to a switch, the receiving switch saves the world-wide name WWN of that primary FCS switch. If a secure switch finds that there are no FCSs in the fabric, but - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 304
that can be executed only on the primary FCS switch as well as one security command that can be executed only on a backup FCS switch. The counter increments every time someone issues one of these commands on a switch where it is not allowed. Recommended Responses to security-class messages depend - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 305
that can be executed only on the primary FCS switch as well as one security command that can be executed only on a backup FCS switch. The counter increments every time someone issues one of these commands on a switch where it is not allowed. Recommended Responses to security-class messages depend - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 306
operation of the switch. Excessive permanent increases can lead to future problems. Recommended No operation of the switch. Excessive permanent increases can lead to future problems. Recommended No operation of the switch. Excessive permanent increases can lead to future problems. Recommended You - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 307
operation of the switch. Excessive permanent increases can lead to future problems. Recommended No action switch status is not in a healthy state. This occurred because the number of faulty or missing power supplies is greater than or equal to the policy set by the switchStatusPolicySet command - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 308
bad. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the faulty power supply. Action Severity WARNING FW-1428 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 309
than or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the faulty WWN card. Action Severity WARNING FW-1433 Message , [FW-1433], ,, WARNING, , Switch status change contributing factor CP: CP non-redundant. Fabric OS - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 310
of faulty CPs is greater than or equal to the policy set by the switchStatusPolicySet command. The CPs are non-redundant. If you power cycle a Brocade 24000 chassis in dual-domain configuration, and then reset the micro-switch of the active CP before the heartbeat is up, this will cause both CPs to - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 311
FW-1437 Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of marginal ports is greater than or equal to the policy set using the switchStatusPolicySet command. A port is faulty when the port value for Link Loss, Synchronization Loss, Signal - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 312
30 FW-1440 Recommended Run the switchEnable command. Action Severity WARNING FW-1440 Message , [FW-1440], (FRU) has changed to "inserted". This means that an FRU is inserted but not powered on. Recommended No action is required. Verify that the event was planned. Action Severity - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 313
Status Policy values pertaining to number of power supplies. So those values will not be automatically changed. The default values with no AP blades are: 3 out of service indicates switch status is DOWN, 0 indicates no checking for switch status MARGINAL. The default values when an AP blade is or - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 314
occur due to software glitches. Persistent errors occur due to hardware problems. Recommended Check for concurrent loss of synchronization errors. Check the SFP and the cable. Then enable the Action port using the portEnable command. Severity INFO 262 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 315
standby CP blade by ejecting the card and reseating it. If the problem persists, replace the standby CP. Severity CRITICAL HAM-1002 Message , or the switch errors. The switch processor reboots can be initiated by the firmwareDownload, fastBoot, haFailover, and reboot commands. Some - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 316
31 HAM-1005 • Unknown • Fastboot • Giveup Master:SYSM • CP Faulty:SYSM • FirmwareDownload • ConfigDownload:MS • ChangeWWN:EM • Reboot:WebTool • Fastboot:WebTool • Software Fault:Software Watchdog • Software Fault:Kernel Panic • Software Fault:ASSERT • Reboot:SNMP • Fastboot:SNMP • Reboot • Chassis - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 317
31 HAM-1006 Recommended The standby CP will take over and reset the active CP.The system will be non-redundant as the Action standby becomes the active CP. Severity CRITICAL Fabric OS Message Reference 265 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 318
31 HAM-1006 266 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 319
and attempts a cold recovery. RUn supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL HAMK-1002 Message , [HAMK-1002], ,, INFO, , Heartbeat down. Probable - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 320
32 HAMK-1004 HAMK-1004 Message ,[HAMK-1004], ,, INFO, , Resetting standby CP (double reset may occur). Probable Cause Indicates that the standby control processor (CP) is being reset due to a loss of heartbeat. This message is typically seen when the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 321
the faulty blade or switch (for nonbladed switches). Action Severity ERROR HIL command to verify the power supply status. Try to reseat the faulty fan field-replaceable unit (FRU) and power supply FRU to verify that they are seated properly. If the problem persists, replace the fan FRU or the power - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 322
, and 4024 the entire switch must be replaced, because these switches do not have field-replaceable units (FRUs). For the Brocade 3900, replace the motherboard FRU. For the Brocade 4100, 4900, 5000, 7500, and AP7600, if the 12 volt level is faulty, replace one or both power supplies; if any other - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 323
area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. Fabric OS Message Reference - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 324
the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. If the fan continues to - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 325
fan speed (in RPM) has fallen below the minimum threshold. This problem can quickly cause the switch to overheat. This message is specific to nonbladed switches and is not applicable to the Brocade 24000, or 48000. Recommended For the Brocade 4100, 4900, 7500, and AP7600, replace the fan field - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 326
-replaceable unit (FRU) has failed or has been removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Replace the affected fan FRU immediately. Action Severity WARNING HIL-1302 Message , [HIL-1302], - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 327
33 HIL-1305 Severity ERROR HIL-1305 Message , [HIL-1305], ,, ERROR, , One or two fan(s) failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fan field-replaceable units (FRUs) have failed. This message is often preceded by - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 328
have failed. This message is often preceded by a low fan speed message. Recommended Since the fans are not field replaceable, replace the switch if the temperature is high. Action Severity WARNING HIL-1311 Message , [HIL-1311], ,, INFO, , No fans are - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 329
33 HIL-1402 Probable Cause Indicates that one fan field-replaceable unit (FRU) has been removed. Recommended Install the missing fan FRU. Action Severity WARNING HIL-1402 Message , [HIL-1402], ,, WARNING, , Two fan FRUs missing. Install fan FRUs - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 330
Recommended Action Run the fanShow command to verify all the fans are working properly. Make sure that the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 331
Recommended Action Run the fanShow command to verify that all fans problems, make sure that all the fans are working properly. Make sure that the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 332
. To help prevent future problems, make sure that all the fans are working properly. Make sure that the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 333
. If any sensor is too high, monitor the switch. Try rebooting or power cycling the switch. Severity CRITICAL HIL-1603 Message , [HIL-1603], , FFDC, CRITICAL, , fans out of service. System is shutting down immediately. Probable Cause - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 334
33 HIL-1650 Severity ERROR 282 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 335
HLO-1003], , FFDC, ERROR, , Invalid Hello received from port , Domain = , Remote Port =. Indicates that the HLO message received was invalid and the frame was dropped. The Brocade switch will not accept FSPF frames from the remote - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 336
an invalid HLO because either the domain or port number in the HLO message has an invalid value. This error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended The HLO message of the remote switch must be compatible with the value specified in - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 337
. Recommended Action Run the firmwareDownload command to reinstall the firmware to your switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL Fabric OS Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 338
35 HMON-1001 286 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 339
>, [HTTP-1001], ,, INFO, , Switch PIDformat has changed to . Probable Cause Indicates that information on PID, format refer to the Fabric OS Administrator's Action Guide. Severity INFO HTTP-1002 Message , [HTTP-1002], - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 340
36 HTTP-1003 288 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 341
Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Power off and power on the blade using the slotPowerOff and slotPowerOn commands. On the Action Brocade 7500 or 7600, switch off and on all primary power in order to power-cycle the unit - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 342
37 IBD-1001 290 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 343
-name>, iSCSI login sessions exceed the maximum limit at slot port ge Probable Cause Indicates that the iSCSI login sessions exceed the supported limit per port. Recommended Use another port to login. Action Severity WARNING Fabric OS Message Reference 291 53-1000600 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 344
38 IBPD-1003 292 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 345
Action Check memory usage on the switch using the memShow command. Reboot or power cycle the switch. Severity ERROR ICPD-1002 Message < name>, iSNS Client service is detected on multiple switches in fabric. Indicates that iSNS Client service is enabled on multiple switches in fabric. - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 346
39 ICPD-1005 Recommended Enable the iSNS Client service on a single switch in the fabric using the fosConfig command. Refer Action to the Fabric OS Command Reference for more information on this command. Severity WARNING ICPD-1005 Message , [ICPD-1005], ,, WARNING, < - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 347
Recommended No action is required. Action Severity INFO 39 ICPD-1008 Fabric OS Message Reference 295 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 348
39 ICPD-1008 296 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 349
Chapter IPAD System Messages 40 IPAD-1000 Message , [IPAD-1000], ,, INFO, address and prefix> Probable Cause Indicates that a change in local IP address has occurred. If the source of the address change is manual, this means that the address - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 350
40 IPAD-1001 DRAFT: BROCADE CONFIDENTIAL 298 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 351
FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING IPS-1004 Message , [IPS-1004], ,, WARNING, , Port Config Mode Mismatch slot () port(ge): current mode is () Fabric - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 352
tunnel to authorize remote side to setup tunnel. Action Severity WARNING IPS-1006 Message , [IPS-1006], ,, WARNING, , Tunnel Configuration Mismatch for slot () port() tunnel ID() reason () Probable Cause Indicates that - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 353
[ISCS-1000], ,, ERROR, , Slot Port GE crashed unexpectedly. Probable Cause Indicates that specified port has crashed. Recommended No action is required; the port will restart automatically. Action Severity ERROR Fabric OS Message Reference - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 354
42 ISCS-1000 302 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 355
slot/port /ge (current /ge). Probable Cause Indicates that the user has issued the isnscCfg command. Recommended No action is required - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 356
, Start re-register with external iSNS server slot/port /ge. Probable Cause Indicates that the re-register with the specified external internet storage name service (iSNS) server has started. Recommended No action is required. Action - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 357
Peering with external iSNS server not started because no virtual targets manual for valid slot and Action port ranges. Severity WARNING ISNS-1011 Message , [ISNS-1011], ,, INFO, , iSNS Client Service is - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 358
Cause Indicates that the internet storage name service (iSNS) client failed to establish a connection with the iSNS server. Recommended Verify the connection of the iSNS server to the slot/port. Use the isnscCfg command to display or Action correct the server IP address. Severity WARNING ISNS-1014 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 359
SIGABRT is the signal thrown by the programs to abort the process. Run the supportSave command to determine, if any core files were created. If a core file is found, core file information, and contact your switch service provider. Severity WARNING Fabric OS Message Reference 307 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 360
44 KSWD-1003 308 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 361
, [KTRC-1003], ,, ERROR, , Cannot open ATA dump device Probable Cause Indicates that the ATA dump driver is not initialized properly. Recommended No action is required. Action Severity ERROR KTRC-1004 Message Probable Cause , [KTRC-1004 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 362
45 KTRC-1005 Recommended No action is required. Action Severity ERROR KTRC-1005 Message , [KTRC-1005], ,, ERROR, , Trace initialization failed. . . Probable Cause Indicates that Trace was unable to - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 363
. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING LOG-1002 Message , [LOG-1002], , FFDC, WARNING, , A log message was - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 364
46 LOG-1003 LOG-1003 Message , [LOG-1003], ,, INFO, , The log has been cleared. Probable Cause Indicates that the persistent error log has been cleared. Recommended No action is required. Action Severity INFO 312 Fabric OS Message Reference 53- - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 365
, whose range is from 1 through 239. The switch will discard the record because it is not supported. Recommended No action is required. Action Severity ERROR state record). The switch generates its local link state record when first enabled. By disabling and enabling the switch, a new local link - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 366
47 LSDB-1004 Recommended Run the switchDisable and switchEnable commands. A new local link state record is generated Action during the switch enable. Severity CRITICAL LSDB-1004 Message , [LSDB-1004], ,, WARNING, , No Link State Record for domain - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 367
then run the supportSave command and contact your switch service provider. Severity ERROR MFIC host or if Action default values are desired for the switch node descriptor fields. Severity any switches added to the fabric are configured with the same IDID mode as the fabric. If you are enabling or - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 368
48 MFIC-1003 IDID mode can be set using the configure command in the CLI or checking the Advanced Web Tools Switch Admin > Configure Tab > Fabric Subtab > Insistent Domain ID Mode checkbox. The switch must be disabled to change the IDID mode. Severity WARNING 316 Fabric OS Message Reference 53- - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 369
Chapter MPTH System Messages 49 MPTH-1001 Message , [MPTH-1001], , FFDC, ERROR, , Null parent, lsId = Probable Cause Indicates that a null parent was reported. MPATH uses a tree structure in which the parent is used to connect to the root of - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 370
49 MPTH-1003 318 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 371
Chapter MQ System Messages 50 MQ-1004 Message , [MQ-1004], ,, ERROR, , mqRead, queue = , queue ID = , type = Probable Cause Indicates that an unexpected message has been received in the specified message queue. The - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 372
50 MQ-1004 320 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 373
. Recommended Action: Set the flag for the MS Platform Service. • The GCAP (MS Get Capabilities) is not supported by another switch. Recommended Action: Upgrade the firmware level on the switch to a level that supports RCS. • The request to the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 374
=BUSY) by> Run the firmwareDownload command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS v2.6, v3.1 and greater, and v4.1 and greater. • Wait a few minutes and try the command again. Severity INFO MS-1003 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 375
again. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR MS-1008 Message , [MS-1008], ,, ERROR, , MS Failure while initializing - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 376
, RLIR event. Switch Port ID is . Device Port Tag is . . Probable Cause A RLIR incidents are likely due to SAN hardware problems such as bad cables, small then run the Action supportSave command and contact your switch service provider. Severity ERROR MS-1022 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 377
[MS-1023], ,, INFO, , Management Server Topology Discovery Service Probable Cause Indicates that Management Server Topology Discovery Service is being enabled or disabled. Recommended No action is required. Action Severity INFO MS-1024 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 378
51 MS-1024 326 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 379
Wait • 5 - Full If this error occurs repeatedly, it means the protocol implementation between two connected switches has problems. Recommended Action Run the nbrStateShow command to check the neighbor state of the port listed in the message. If it is FULL, then this message can safely be ignored - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 380
set in state , input , port Probable Cause Indicates that the database transmit set flag 5 - Full Recommended No action is required. The Fabric OS auto recovers from this problem. Action Severity WARNING 328 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 381
payload exceeds the maximum frame size that the remote switch can handle. Recommended Action Run the firmwareDownload command to upgrade the remote switch with firmware v4.3 or higher, as appropriate for the switch type, so that it can support GMI to handle frame fragmentation and reassembly. You - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 382
firmware versions running on the active and standby CPs. This means that the active and standby CPs are out of sync. Any execution of the haFailover or firmwareDownload commands size to 1024 or lesser, or upgrade the software of the remote switch to support Action 2048 zones. Severity WARNING NS- - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 383
) process. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 384
(FSS). Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1006 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 385
the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1009 Message , [PDM-1009], ,, WARNING, , Can't update Port - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 386
is empty. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1014 Message Probable - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 387
PDM-1017 Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1017 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 388
peer because the firmware does not support IPv6. Recommended Action Configure the local switch with IPv4 addresses. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 389
PDM-1024 Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 390
54 PDM-1024 338 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 391
a core reset. • 0x20000000 bit set means that the WDT forced a chip reset. • All other code values are reserved. Recommended Run the pdShow command to view the panic dump and core dump files. Action Severity INFO PDTR-1002 Message , [PDTR-1002], ,, INFO, - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 392
55 PDTR-1002 340 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 393
issuing the reboot command from a command-line prompt. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service does not solve the problem. If Action the problem still persists, then replace the CP. Fabric OS Message Reference - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 394
-1003 Message , [PLAT-1003], , FFDC, CRITICAL, , Slot C/BE: ADBUS: misc_intr . Probable Cause Indicates that a PCI bus hang was detected - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 395
some buffers and allow this port to be enabled. Severity INFO PORT-1005 Message Probable Cause , [PORT-1005], ,, WARNING, , Slot port does not support configured L_port. Issue portCfgLport to clear configuration. Indicates - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 396
57 PORT-1005 Recommended Invoke the portCfgLport to clear the L_port configuration. Action Severity WARNING 344 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 397
it does not, reboot or power cycle the switch to Action reinitiate the firmware. Severity CRITICAL PS-1001 Message action is required. Refer to the Fabric OS Administrator's Guide for more information about the Action PID format. Severity ports. Fabric OS Message Reference 345 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 398
has attempted to set the end-to-end monitoring mask on at least one ISL port. Recommended No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is Action enabled. ISL monitoring can only be disabled through the Fabric Access API. Severity WARNING PS-1004 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 399
command has been issued. Recommended No action is required. Action Severity INFO PSWP-1002 Message , [PSWP-1002], ,, INFO, , Port Swap feature enabled. Probable Cause Indicates that the portSwap feature has been enabled in the switch. Recommended - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 400
59 PSWP-1003 348 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 401
data was captured. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity INFO RAS-1002 Message , [RAS-1002], ,, WARNING, , First failure data - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 402
Indicates an internal software error. Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING RAS-1006 Message , [RAS-1006], , INFO, , Support data file () automatically transferred to - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 403
INFO RAS-3002 Message , [RAS-3002], , INFO, , USB storage device enabled. Probable Cause Indicates that the USB storage device is enabled. Recommended No action is required. Action Severity INFO RAS-3003 Message , [RAS-3003], - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 404
60 RAS-3004 Recommended No action is required. Action Severity INFO 352 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 405
command to upgrade the firmware for any switches that do not support RCS. Severity INFO RCS-1002 Message , [RCS-1002], ,, INFO, , RCS has been enabled command. Check memory usage on the switch using the memShow command. Reboot or power cycle the switch. - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 406
.1 and greater. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity ERROR RCS-1005 Message might not be compatible or the domain does not have the license to support that application. Recommended Action If the reject is in ACA phase - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 407
1007 Message , [RCS-1007], ,, ERROR, , Zone DB size and propogation overhead exceeds domain 's maximum supported Zone DB size . Retry after reducing the Zone DB size. Probable Cause Indicates that a domain cannot handle the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 408
61 RCS-1008 356 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 409
reported. The specified client IP address has faulty credentials. Recommended Enter the correct user name and password from the Fabric Access SSL certificate is missing. Recommended To enable RPCD in Secure mode, install a valid SSL certificate on the switch. Action Severity WARNING RPCD-1003 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 410
has been corrupted. Recommended To enable RPCD in Secure mode, install a valid SSL certificate the switch. Action Severity WARNING RPCD-1005 Message the private key file has been corrupted. Recommended Run the pkiCreate command to install a valid private key file. Action Severity WARNING 358 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 411
see if the specified domain ID is online. Enable the switch with the specified domain ID. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 412
and retried. Recommended Action Run the dom command to verify that the specified domain ID is reachable. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO 360 Fabric OS - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 413
64 SAS-1001 Message , [SAS-1001], ,, ERROR, , string description of command which failed> of GE failed. Please retry the command. Data inst= st= rsn= fn= oid - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 414
64 SAS-1001 362 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 415
watchdog will cause the daemon to dump the core and reboot the switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL Fabric OS Message Reference 363 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 416
65 SCN-1001 364 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 417
be capable on all switches in the fabric to be enabled. If all switches are capable, RCS is automatically enabled. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 418
fabric. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING SEC-1005 Message , [SEC-1005], ,, INFO, , Primary FCS receives data - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 419
HTTP connection. Probable Cause Indicates that a security violation was reported. The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through the HTTP connection. Action Severity INFO SEC-1009 Message , [SEC - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 420
switch. If the private key does not exist, follow the steps for re-creating PKI objects, outlined in the Secure Fabric OS Administrator's Guide. If a certificate does not exist or is invalid, install the certificate by following the field upgrade -name>, Invalid IP address () detected. - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 421
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 422
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the sync. Probable Cause Indicates that the security database size is not supported by the standby control processor (CP). Recommended Reduce the security - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 423
in the secPolicyAdd command. Only the secPolicyCreate command supports use of the asterisk for adding switches to policies. Recommended Action Run the secPolicyAdd command using a valid switch identifier (WWN, domain ID, or switch name) to add specific switches to the switch connection control - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 424
in the policy member list had an invalid format. Recommended Run the command again using the standard WWN format, 16 hexadecimal digits grouped as , Invalid port member in portlist (). . Probable Cause Indicates that the port member is invalid for - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 425
-number>,, ERROR, , Invalid index/area member in portlist (). Out of range ( - - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 426
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 427
], ,, ERROR, , Missing brace for port list . Probable Cause Indicates that there has been a corruption during Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 428
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 429
.,> to flash. Probable Cause Indicates that the operation failed when writing to flash. Recommended Run the supportFtp - e command to FTP files from the switch and remove them from the flash. Action Severity ERROR SEC-1062 Message , [SEC-1062], ,, ERROR - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 430
command to verify that all PKI objects are valid. If PKI objects are not valid, Action generate the PKI objects and install the certificate by following the field upgrade FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1071 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 431
for unknown reasons. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1073 Message , [SEC-1073], ,, ERROR, , No FCS policy in - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 432
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 433
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 434
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 435
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 436
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 437
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 438
up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1099 Message , [SEC-1099], ,, ERROR, , Please enable your switch before running secModeEnable. Probable Cause Indicates that - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 439
Cause Indicates that the security enable failed on the fabric because one or more switches in the fabric are busy. Recommended Action Verify that the security event was planned. If the security event was planned, run the secFabricShow command to verify that all switches in the fabric are in - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 440
to verify that all switches in the fabric are in the ready state. Retry the Action command when all switches are READY. Severity ERROR switch. If a failure to validate PKI objects occurs, follow the steps for re-creating PKI objects outlined in the Secure Fabric OS Administrator's Guide - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 441
Verify that the security event was planned. If the security event was planned, run the secFabricShow command to verify that all switches in the fabric are in the ready state. When all switches are in the ready state, retry the operation. Severity ERROR SEC-1110 Message , [SEC-1110 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 442
> [ license ] is expired. Probable Cause Indicates that the license period has expired. Recommended Get a new license for this feature. Recommended Run the secFabricShow command to verify that all switches in fabric are in the ready state. When Action all switches are in the ready - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 443
switch. This data can be an FCS password, a non-FCS password, SNMP data, or multiple user authentication data. Recommended Run the secFabricShow command to verify that all switches not be set. Recommended Usually this problem is transient. Retry the command. Action Severity INFO SEC-1119 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 444
could not communicate with the primary fabric configurations server (FCS). Recommended Run the secFabricShow command to verify that all switches in fabric are in the ready state. When Action all switches are in the ready state, retry the operation. Severity INFO SEC-1123 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 445
INFO SEC-1130 Message , [SEC-1130], ,, INFO, , The Primary FCS has failed over to a new switch. Probable Cause Indicates that an FCS failover operation was completed successfully. Recommended Action Verify that the security event was planned. If the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 446
time service, or the signature verification failed. Signature verification failure indicates either an internal error (such as losing the primary public key) or an invalid database. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 447
service, or the signature verification failed. Signature verification failure indicates either an internal error (such as losing the primary public key) or an invalid database. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches passwords - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 448
must be capable on all switches in the fabric to be enabled. If all switches are capable, it is automatically enabled. For any switch that does not support RCS, obtain the latest firmware version from your switch supplier, and run the firmwareDownload command to upgrade the firmware. If the message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 449
) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO SEC-1158 Message , [SEC-1158], ,, INFO, , Invalid name . Fabric OS Message Reference 397 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 450
error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 451
1165], ,, ERROR, , Low memory, failed to enable security on all switches. Probable Cause Indicates that the system is low on memory. Recommended Wait a few minutes and try the command again. Action Severity ERROR SEC-1166 Message , [SEC-1166], - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 452
due to invalid security object. Probable Cause Indicates that the switch is segmented, and secure mode is disabled on the switch because there was no license present or no public key infrastructure (PKI) objects. Recommended Run the pkiShow command to check if all PKI objects exist. If they do - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 453
SEC-1172 Run the licenseAdd command to install the required license key. Refer to your switch supplier to obtain a license if you do not have or non-FCS> password. Probable Cause Indicates that the FCS or non-FCS password could not be set. Recommended Verify that all switches in the fabric are - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 454
that the primary fabric configurations server (FCS) failed to generate a new version stamp due to the fabric not being stable. Recommended Verify that all switches in the fabric are in time synchronization with the primary and that no Action external entity is trying to access the fabric. When - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 455
-name>, Policy to binary conversion error: Port is out range. Probable Cause transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1184 switch DB. Probable Cause Indicates that the switch database was enabled or disabled - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 456
that the remote authentication dial-in user service (RADIUS/LDAP) configuration was enabled or disabled as the primary authentication, accounting device node name> tries to FLOGI to index/area of switch . Probable Cause Indicates that a device connection control ( - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 457
66 SEC-1189 SEC-1189 Message , [SEC-1189], ,, INFO, , Security violation: Unauthorized host with IP address tries to do SNMP write operation. Probable Cause Indicates that an SNMP security violation was reported. The specified unauthorized - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 458
lists the violating IP address. Verify that this IP address is being used by a valid Action switch admin. Use the correct password. Severity INFO Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 459
Switch does not have all default account names. Probable Cause Indicates that the default switch accounts admin and user do not exist on the switch when enabling security. Recommended Reset the default Recommended Action Check to see if the host IP address specified in the message can be used to - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 460
access to serial port of switch . Probable Cause command was forwarded from a non-primary fabric configurations server (FCS) switch. Recommended Action Check the MS policy and verify that the connection is allowed. If the connection is allowed but not specified, enable - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 461
name>, device port name . Probable connection is allowed but not specified, enable the connection in the MS policy. RSH. IP Addr: Probable Cause Indicates the IP address then run the supportSave command and contact your switch service provider. Severity WARNING - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 462
; then run the supportSave command and contact your switch service provider. Severity ERROR SEC- switch is in interop mode. Security is not supported. Probable Cause Indicates that the switch is interop-mode enabled. Recommended Disable interop-mode using the interopMode command before enabling - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 463
installed software version does not support the Brocade Secure Fabric OS feature. Recommended Run the firmwareDownload command to update the firmware to the latest version for your specific Action switch. Verify that the firmware you are installing supports the Brocade Secure Fabric OS feature - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 464
command and verify that all public key infrastructure (PKI) objects exist on the switch. If a failure to validate PKI objects occurs, follow the steps for re-creating PKI objects outlined in the Secure Fabric OS Administrator's Guide in user service (RADIUS/LDAP) server responded to a switch request. - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 465
service enable failed on the fabric because one or more switches in the fabric have password policies that are not set to the default value. Recommended Action Verify that the security event was planned. If the security event was planned, run the passwdCfg --setDefault command on each switch - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 466
parameters were set to default values. Probable Cause Indicates that the passwdCfg parameters were set to default values. Recommended Action Verify the IP address failed. Recommended Please reboot the system to fix this error. If the problem persists contact your switch service Action provider - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 467
to the fabric, as specified by Domain Number, have a conflicting policy with the local switch. Recommended Check the conflicting policy and make the new switches and the local switch policies the same. Action Severity WARNING SEC-1317 Message , [SEC-1317], ,, INFO - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 468
supporting ports from connecting to the Action fabric. Severity WARNING SEC-1321 Message , [SEC-1321], ,, ERROR, , Failed secure mode enable command. Reason: . Probable Cause Indicates that the security enable failed on the fabric because switch - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 469
error: Probable Cause Indicates that the reliable commit service (RCS) transaction failed with specified reason code. Recommended Verify that number>,, ERROR, , Security enforcement: Switch connecting to port is not authorized to stay in fabric - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 470
>. Probable Cause Indicates that the IP filter policy enforcement failed due to internal system failure. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1330 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 471
, , Attempt to enable secure mode failed. Reason: . Probable Cause Indicates that the secModeEnable command failed on the fabric, because default IP Filter policies are not active on the switch, or an active transaction exists on IP Filter policies. Recommended Action Verify - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 472
66 SEC-1332 420 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 473
SNMP) service could not be started because of the specified Reason. You will not be able to query the switch through SNMP. Recommended Verify that the IP address (SNMP) service failed and you will not be able to query the switch through SNMP. Recommended Reboot or power cycle the switch. This will - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 474
and the SNMP service will not work correctly. Recommended Change the SNMP configuration back to the default. Action Severity ERROR and new values for that parameter. Recommended Execute the snmpConfig --show command to see the new configuration. Action Severity INFO SNMP-1006 Message < - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 475
>, [SS-1000], ,, INFO, , supportSave has uploaded support information to the host with IP address . Probable Cause Indicates that the supportSave command was used to transfer support information to a remote location. Recommended No action is required. Action - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 476
message due to possible errors in subcommands being executed by the supportSave command. Recommended Run usbstorage to check the USB storage device settings. After the USB problem is corrected, Action rerun the supportSave command. Severity WARNING 424 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 477
out after 30 minutes. Recommended Action Do not fail over or power down the system during firmware upgrade. Allow the firmwareDownload command to continue without disruption. Do not fail over or power down the system during firmware upgrade. No action is required. Run the firmwareDownloadStatus - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 478
standby has now become the active CP and is running the new firmware version. Recommended Action No action is required. The firmwareDownload command is progressing as expected. Run the firmwareDownloadStatus command for more information. Severity INFO SULB-1007 Message , [SULB-1007 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 479
for more information. Severity INFO SULB-1009 Message Probable Cause AUDIT, , [SULB-1009], AUDIT, INFO, FIRMWARE, , , , Firmwaredownload command failed. status: 0x, error: 0x. Indicates that the firmwareDownload - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 480
secondary partition. Please use firmwareDownloadStatus and firmwareShow to see firmware status." "firmwareDownload has started on Standby CP. up." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareDownload has completed successfully on Standby CP." - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 481
firmwareDownloadStatus and 0x88 firmwareShow to see the firmware status." "Please use firmwareDownloadStatus and firmwareShow to see the firmware status." 0x89 "firmwareDownload command has completed successfully." 0x8a "The original firmware has been restored successfully." 0x8b "Remote CP - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 482
same version of firmware." 0xF "Upgrade is inconsistent. Run the bootEnv (root) command to correct the switch is supported by the requested firmware. Also check firmwareDownload help page for other possible failure reasons." 0x12 "The RPM package database is inconsistent. Contact your service - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 483
to upgrade to an intermediate version before downloading the desired version. If this error occurs in the middle of firmwareDownload, the firmware in the file server may be corrupted or there may be a temporary network issue. In this case, retry the firmwareDownload command. If the problem persists - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 484
command before proceeding. 0x29 - The pre-install script failed. This error may be caused by an unsupported blade type in the chassis. Remove or power by temporary networking issues. Please reload firmware packages on the file server, then retry firmwareDownload. If the problem persists, contact your - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 485
upgrade the firmware on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting filesystem, contact your switch service provider. Action Severity INFO - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 486
, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1020 Message , [SULB-1020], AUDIT, ERROR, , New firmware failed to boot in slot . Probable Cause The BP - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 487
unexpected disruption of the firmwareDownload command, for example, by powering off and on of the command to monitor the progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message , [SULB-1024], AUDIT, WARNING, , Firmware - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 488
the firmwareDownloadStatus Action command to monitor progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message , [SULB-1031], , AUDIT, WARNING, , The switch is relocating an internal firmware image. 436 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 489
by an internal Ethernet issue or by persistent storage failure. Recommended Action Reboot the switch. This will cause the internal image to be relocated again. Use the firmwareDownloadStatus to monitor the progress. If the problem persists, contact your switch service provider. Severity ERROR - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 490
and after download of the firmware to store version information. Recommended No action is required. Action Severity INFO SULB-1037 Message , [SULB-1037], , AUDIT, INFO, , HCL failed. Reboot the switch manually using the reboot command. However, it will - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 491
as inconsistent during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn command. On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch. Severity ERROR Fabric OS Message Reference 439 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 492
fabric. Recommended Load a firmware version on standby that supports NPIV functionality, using the firmwareDownload Action command. Severity WARNING SWCH-1007 Message Probable Cause , [SWCH-1007], ,, WARNING, , Switch port disabled due to - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 493
the blade is enabled with the port configuration that already has area swapped. Recommended Action Replace the blade with ports that support port swap. Then port swap the ports back to ports default area. Refer to the Fabric OS Administrator's Guide for more information on port swapping. Severity - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 494
control processor (CP) does not support Trunk Area functionality, but the switch has some ports with Trunk Area enabled. Recommended Load a firmware version on standby that supports Trunk Area functionality, using the Action firmwareDownload command. Severity WARNING 442 Fabric OS Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 495
power cycle. Before rebooting the chassis, record the firmware version on the switch or control processor (CP) and run the haDump command. If this is a dual-CP switch, is not supported by CP Blade with ID - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 496
Brocade 24000 and 48000. Recommended Action As indicated in the message, run the chassisConfig command to change to one that is valid on this platform running this firmware Use the supportSave command to gather troubleshooting data. Issue a reboot or haFailover Action command to recover the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 497
memory. Recommended Action Run the memShow command to view the switch memory usage. Reboot or power cycle the switch. Run supportFtp as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL SYSM-1002 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 498
72 SYSM-1004 SYSM-1004 Message , [SYSM-1004], ,, ERROR, , Failed to retrieve current chassis configuration option, ret= Probable Cause Indicates that there was a failure to read configuration data from the WWN card. Recommended Verify that the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 499
WATCHDOG EXPIRED generated by hardware watchdog expiration • MANUAL generated by the tracedump -n command Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity WARNING TRCE-1002 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 500
automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR TRCE-1004 Message , to the FTP host has succeeded. This feature is enabled by the supportFtp -t command. Recommended No action is required. Action Severity INFO - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 501
to the Brocade 24000, and 48000. Recommended Action This message is often transitory. Wait a few minutes and try the command again. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 502
system and the indicated slot is unavailable. Recommended Check that the AP blade is enabled and retry the command. If the AP blade is already enabled, run Action the supportSave command and contact your switch service provider. Severity WARNING 450 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 503
name or password is entered incorrectly. Recommended Action Normally, this message indicates a typing error by an authorized user. If this message occurs repeatedly, it might indicate an unauthorized user trying to gain access to a switch. When Secure mode is enabled on the fabric, the IP address - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 504
that the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration that the track change feature has been enabled. Recommended No action is required. Run the trackChangesSet 0 command to disable the track change feature. - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 505
switch was IP network connection issues to the external clock server or if the fabric is configured for external time synchronization but the principal or primary FCS does not support the feature. If the message does not recur, it should be ignored. Recommended Action Run the tsClockServer command - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 506
Service exiting Probable Cause: Initialization error, Time Server exits. • Synchronizing time of day clock Probable Cause: Usually logged during temporary operational issues from the principal or primary fabric configuration server (FCS) switch. Another clock server in the list of clock servers - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 507
Severity WARNING 75 TS-1008 Fabric OS Message Reference 455 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 508
75 TS-1008 456 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 509
: Port = , should be Probable Cause Indicates that the switch detected port number displayed is what the protocol is using. Recommended Run the switchDisable command and then the switchEnable command to reset the routing Action database. Run the uRouteShow command - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 510
76 UCST-1020 458 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 511
, [UPTH-1001], ,, WARNING, , No minimum cost path in candidate list Probable Cause Indicates that the specified switch is unreachable because no minimum cost path (FSPF UPATH) exists in the candidate list (domain ID list). Recommended No action is required - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 512
77 UPTH-1001 460 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 513
Chapter WEBD System Messages 78 WEBD-1001 Message , [WEBD-1001], ,, WARNING, , Missing or Invalid Certificate file -- HTTPS is configured but could not be started. Probable Cause Indicates that the SSL certificate file is either invalid or absent. - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 514
will be restarted due to change of IP Address Probable Cause Indicates that the IP address of the switch changed and the HTTP server is restarted. where the built-in recovery process has failed to restore http services. The problem often results from invalid configuration of ssl certs. But there - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 515
of the related modules (zoned, nsd, rcsd). If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command to save these core files and contact your switch service provider. Severity ERROR Fabric OS Message Reference 463 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 516
79 ZOLB-1001 464 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 517
during port login (PLOGI) trap processing. This messages usually indicates problems when command and contact your switch service provider. Severity WARNING ZONE-1003 Message , [ZONE-1003], ,, WARNING, , zone() contains (, - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 518
using one method or the other to define all objects in the zoning database. If the devices on the port are defined by a mixture of port IDs and WWNs, the zone enforcement is session based. If the S_ID list of the hardware-enforced zoning overflows (over the S_ID limit), the hardware zone enforcement - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 519
problem. • Avoid having too many hosts zoned with a set of target devices at a single port. • Avoid having too many zones directed at a single port group on the switch in a given zone object. This message occurs only when enabling a zone configuration. Recommended Check the members of the zone and - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 520
is enabled on the switch, it will not be supported. Recommended Edit the zone database to remove the QuickLoop zoning definition in the effective configuration. Action Severity WARNING ZONE-1014 Message , [ZONE-1014], ,, ERROR, , Missing required license - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 521
port( - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 522
operation. This usually occurs if the switch on the other side of the port is busy. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity INFO ZONE-1024 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 523
an unknown reason. • User Command: A user aborted the current zoning transaction. • Switch Shutting Down: The switch is currently shutting down. Recommended switches in your fabric. Refer to the Fabric OS Administrator's Guide for information on the zone database sizes supported for each switch. - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 524
up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING ZONE-1030 Message , Switch is in interop mode. (switch, port) members not supported. Probable Cause The switch is set to interop mode using the interopMode command. - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 525
zone database is not found. Recommended Use the firmwareDownload command to reinstall the firmware. Action Severity WARNING ZONE-1035 Message , [ the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 526
that the Fabric OS cannot read the zone configuration file. Typically the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation. Action Severity ERROR ZONE-1040 Message , [ZONE-1040], - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 527
WARNING, , Unstable link detected during merge at port (). Probable Cause Indicates a possible unstable link or faulty Probable Cause Indicates that the Default Zone access mode is set to No Access. Recommended Verify that this Default Zone access mode change was done - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 528
-number>,, INFO, , Switch domain () does not support defined database. Probable Cause Indicates that remote Brocade switch is running downlevel version of FOS that does not suppport the defined database. Recommended It is recommended to upgrade all swtiches to same release - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 529
Audit Log Messages Section II This section provides the Audit messages, including: •AUDIT AUTH System Messages 479 •AUDIT CONF System Messages 483 •AUDIT FW System Messages 485 •AUDIT HTTP System Messages 487 •AUDIT SEC System Messages 489 •AUDIT SNMP System Messages 505 •AUDIT SULB System - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 530
- HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 531
Status: success, Info: . Probable Cause Indicates that the secret database operation has been updated using the secAuthSecret command. Recommended No action is required. Action Severity INFO AUTH-3003 Message AUDIT, , [AUTH-3003], INFO, SECURITY, - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 532
authentication. Recommended Action If the light on the specified port is off, correct the switch policy configuration on either of the switches using the authUtil command, and then enable the port on the neighboring switch using the portEnable command. If the E_Port formed no action is required - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 533
>, , Event: , Status: failed, Info: Port disabled due to receiving an authentication reject with code to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO AUTH-3008 Message AUDIT, , - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 534
2 AUTH-3008 482 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 535
parameters that were downloaded. If admin domain (AD) is enabled, the AD number is specified in the description. Recommended No switch was unsuccessful because there are one or more parameters that require the switch to be disabled. Recommended Disable the switch using the switchDisable command - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 536
3 CONF-1022 484 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 537
, , , , Event: , Status: success, Info: Probable Cause Indicates that Port Fencing was enabled/disabled successfully. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 485 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 538
4 FW-3001 486 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 539
AUDIT HTTP System Messages Chapter 5 HTTP-1002 Message AUDIT, , [HTTP-1002], INFO, ZONE, , , , Zoning transaction initiated by User: , Role: completed successfully. Probable Cause Indicates that the zoning database has - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 540
5 HTTP-1003 488 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 541
, Status: success, Info: Security mode on the fabric. Probable Cause Indicates that the security saved. • A security policy has been aborted. • A non-FCS password has changed. Recommended Action Verify that the security event was planned. If the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 542
6 SEC-3004 Probable Cause Indicates that a new security policy was created with entries. Note: If you use a wildcard (for example, an asterisk) in creating a policy, the audit report displays the wildcard in the event info field. Recommended Action Verify that the new policy creation was planned - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 543
SEC-3007 6 Probable Cause Indicates that a user has removed the specific members from the specified security policy. Note: If you use a wildcard (for example, an asterisk) in removing members from a policy, the audit report displays the wildcard in the event info field. Recommended Action - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 544
SEC-3012 Message AUDIT, , [SEC-3012], INFO, SECURITY, , , , Event: , Status: success, Info: Temp Passwd on domain [] for account []. Probable Cause Indicates that a user has reset the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 545
name> to position . Probable Cause Indicates that a user has changed the position of the remote authentication dial-in user service (RADIUS) server. Recommended Action Verify that the RADIUS server position was intentionally changed. If the RADIUS server position was intentionally - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 546
: success, Info: . Probable Cause Indicates that a user has changed the remote authentication dial-in user service (RADIUS) configuration. Recommended Action Verify that the RADIUS configuration was intentionally changed. If the RADIUS configuration was intentionally changed - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 547
Passwdcfg parameters set to default values. Probable Cause Indicates that the passwdCfg parameters are set to default values. Recommended Action Verify attempt via . Probable Cause Indicates that a successful login occurred. An IP Address is displayed when the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 548
attempts exceeded. Probable Cause Indicates that failed password attempts exceeded, the account has been locked. Recommended The Account may automatically unlock after the lockout duration has expired or an administrator Action may manually unlock the account. Severity INFO SEC-3024 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 549
, , , , Event: , Status: success, Info: User account [] added. Role: [], Password [], Home AD [], AD list []. Probable Cause Indicates a new user account was created - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 550
6 SEC-3029 Recommended Action Verify that the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3029 Message AUDIT, , [ - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 551
, , Event: , Status: success, Info: Switch is configured to database. Probable Cause : ipfilter, Status: success, Info: IP filter policy(ies) saved. Indicates that the specified IP filter policy(ies) have been saved. - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 552
, , , , Event: ipfilter, Status: failed, Info: Failed to save changes for ipfilter policy(s). Probable Cause Indicates that the specified IP filter policy(ies) have not been saved. Recommended Action Verify that the security event was - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 553
The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through [ license ] is expired. Probable Cause Indicates that the license period has expired. Recommended Get a new license for this feature. Action Severity - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 554
Verify that the user has the required permission to execute this command. Action Severity INFO SEC-3048 Message AUDIT, , [SEC-3048], INFO, SECURITY, , , FIPS mode has been enabled in the system using force option. Probable Cause Indicates that - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 555
SEC-3049 6 Severity INFO SEC-3049 Message AUDIT, , [SEC-3049], INFO, SECURITY, , , Status of bootprom access is changed using fipscfg CLI to : . Probable Cause Indicates that the status of bootprom access is changed using the - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 556
6 SEC-3050 504 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 557
incorrect and the SNMP service will not work correctly. Recommended Reset the SNMP configuration to default. Action Severity ERROR SNMP and new values for that parameter. Recommended Execute the snmpConfig --show command to display the new configuration. Action Severity INFO SNMP-1006 Message - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 558
7 SNMP-1006 506 Fabric OS Message Reference 53-1000600-02 - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 559
. Recommended Action No action is required. Allow the firmwareDownload command to continue without disruption. Do not fail over or power down the system during firmware upgrade. Run the firmwareDownloadStatus command for more information. Severity WARNING SULB-1002 Message AUDIT, - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 560
for more information. Action Severity INFO SULB-1009 Message Probable Cause AUDIT, , [SULB-1009], INFO, FIRMWARE, , , , Firmwaredownload command failed. status: 0x, error: 0x. Indicates that the firmwareDownload - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 561
secondary partition. Please use firmwareDownloadStatus and firmwareShow to see firmware status." "firmwareDownload has started on Standby CP. up." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareDownload has completed successfully on Standby CP." - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 562
firmwareDownloadStatus and 0x88 firmwareShow to see the firmware status." "Please use firmwareDownloadStatus and firmwareShow to see the firmware status." 0x89 "firmwareDownload command has completed successfully." 0x8a "The original firmware has been restored successfully." 0x8b "Remote CP - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 563
same version of firmware." 0xF "Upgrade is inconsistent. Run the bootEnv (root) command to correct the switch is supported by the requested firmware. Also check firmwareDownload help page for other possible failure reasons." 0x12 "The RPM package database is inconsistent. Contact your service - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 564
to upgrade to an intermediate version before downloading the desired version. If this error occurs in the middle of firmwareDownload, the firmware in the file server may be corrupted or there may be a temporary network issue. In this case, retry the firmwareDownload command. If the problem persists - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 565
command before proceeding. 0x29 - The pre-install script failed. This error may be caused by an unsupported blade type in the chassis. Remove or power by temporary networking issues. Please reload firmware packages on the file server, then retry firmwareDownload. If the problem persists, contact your - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 566
firmwareDownload single mode (-s) to upgrade the firmware on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting information. Severity INFO SULB - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 567
the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1021 Message AUDIT, , [SULB-1021], WARNING, FIRMWARE, , , , Firmware is being downloaded to the blade in slot - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 568
version is still inconsistent with the active CP firmware, firmwareDownload will automatically be restarted on the blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message AUDIT - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 569
switchShow command to Action make sure the switch is enabled. Severity WARNING SULB-1034 Message Probable Cause AUDIT, , [SULB-1034], ERROR, FIRMWARE, , , , Firmwaredownload timed out. The error may be caused by a switch initialization issue - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 570
again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1037 Message AUDIT, , [SULB-1037], ERROR, FIRMWARE, , , , HCL failed. Reboot the switch manually using the reboot command. However, it will - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 571
AUDIT ZONE System Messages Chapter 9 ZONE-3001 Message AUDIT, , [ZONE-3001], INFO, ZONE, , , , Event: , Status: success, Info: \"\" added to \" - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 572
9 ZONE-3004 The zone object type can be "alias", "zone member", "zone" or "zone configuration". The string "..." appears at the end of the zone object member list if the list was truncated in the message. Recommended Verify that the event was planned. If the event was planned, no action is required - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 573
-details>, , , Event: , Status: success, Info: Zone configuration \"\" enabled. . Probable Cause Indicates that the specified zone configuration has been enabled. Recommended Verify that the event was planned. If the event was planned, no - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 574
9 ZONE-3011 Severity INFO ZONE-3011 Message AUDIT, , [ZONE-3011], INFO, ZONE, , , , Event: , Status: success, Info: Zone object \"\" expunged. Probable Cause Indicates that the specified zone object has been - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 575
ZONE-3015 9 An AD object set type is "AD member". The string "..." appears at the end of the AD object member list if the list was truncated in the message. Recommended Verify that the event was planned. If the event was planned, no action is required. If the event was Action not planned, take - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 576
9 ZONE-3018 ZONE-3018 Message AUDIT, , [ZONE-3018], INFO, FABRIC, , , , Event: , Status: success, Info: has been deactivated. Probable Cause Indicates that the specified admin domain (AD) object has been deactivated - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 577
Severity INFO ZONE-3025 Message Probable Cause Recommended Action AUDIT, , [ZONE-3025], INFO, FABRIC, , , , Command: Info: executed. In AD . Indicates that the admin domain ad --exec operation was executed in the specified - HP 8/24 | Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 578
9 ZONE-3025 Severity INFO 526 Fabric OS Message Reference 53-1000600-02
53-1000600-02
12 March 2008
Fabric OS
Message Reference
Supporting Fabric OS v6.1.0