53-1001157-01 24 November 2008 Fabric OS Message Reference Supporting Fabric OS v6.2.0 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 2
implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade and product availability. Export of technical data contained in this document may require please visit http://www.brocade.com/support/oscd. Brocade Communications Systems, Incorporated - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 3
ZONE January 2006 Reference Manual messages Fabric OS System Error Message 53-1000046-02 Minor updates to a few messages. Reference Manual June 2006 Fabric OS chapters. -Update throughout: rebranding, supported hardware, CLI changes. June 2007 Fabric OS Message Reference iii 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 4
Title Fabric OS Message Reference Fabric OS Message Reference Fabric OS Message Reference Fabric OS Message Reference Publication Summary of changes Date number 53-1000600-01 Updated for Fabric OS v6.0.0: -Added new chapters: C2, ESS, FICON -Added new messages to: AG, BL, BM, C2, FCIP, ISW, NS - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 5
Contents About This Document In this chapter xlvii How this document is organized xlvii Supported hardware and software xlvii What's new in this document xlviii Document conventions xlix Additional information l Getting technical help li Document feedback lii Chapter 1 Introduction To - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 6
Responding to a System Message 11 Looking Up a System Message 11 Gathering Information About the Problem 12 Support 12 Panic Dump and Core Dump Files 12 Trace Dumps 13 supportSave Command 13 System Module Descriptions 13 Section I RASLog Messages Chapter 2 AG System Messages - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 7
Chapter 3 AG-1026 31 AG-1027 32 AG-1028 32 AG-1029 32 AUTH System Messages AUTH-1001 33 AUTH-1002 33 AUTH-1003 33 AUTH-1004 34 AUTH-1005 34 AUTH-1006 34 AUTH-1007 34 AUTH-1008 35 AUTH-1010 35 AUTH-1011 35 AUTH-1012 36 AUTH-1013 36 AUTH-1014 36 AUTH-1016 36 AUTH-1017 37 AUTH-1018 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 8
Chapter 4 Chapter 5 AUTH-1037 43 AUTH-1038 43 AUTH-1039 43 AUTH-1040 44 AUTH-1041 44 AUTH-1042 44 AUTH-1043 45 AUTH-1044 45 BKSW System Messages BKSW-1003 47 BL System Messages BL-1000 49 BL-1001 49 BL-1002 49 BL-1003 50 BL-1004 50 BL-1006 50 BL-1007 51 BL-1008 51 BL-1009 51 BL- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 9
Chapter 6 Chapter 7 Chapter 8 BL-1025 57 BL-1026 57 BL-1027 58 BL-1028 58 BL-1029 58 BL-1030 59 BL-1031 59 BL-1032 59 BL-1033 59 BL-1034 60 BL-1035 60 BL-1036 60 BL-1037 61 BLL System Messages BLL-1000 63 BM System Messages BM-1001 65 BM-1002 65 BM-1003 65 BM-1004 66 BM-1005 66 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 10
C2-1005 72 Chapter 9 CDR System Messages CDR-1001 73 CDR-1002 73 CDR-1003 73 CDR-1004 74 Chapter 10 CER System Messages CER-1001 75 Chapter 11 CHASSIS System Messages CHASSIS-1002 77 CHASSIS-1003 77 CHASSIS-1004 77 CHASSIS-1005 78 Chapter 12 CNM System Messages CNM-1001 79 CNM- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 11
CNM-1021 84 CNM-1022 84 CNM-1023 84 CNM-1024 84 CNM-1025 85 CNM-1026 85 CNM-1027 85 CNM-1028 85 CNM-1029 86 CNM-1030 86 CNM-1031 86 CNM-1032 86 CNM-1033 87 CNM-1034 87 CNM-1035 87 CNM-1036 87 CNM-1037 88 CNM-1038 88 CNM-1039 88 CNM-1040 88 CNM-1041 89 CNM-1042 89 CNM-1043 89 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 12
CVLC-1002 95 CVLC-1003 95 CVLC-1004 96 CVLC-1005 96 CVLC-1006 96 CVLC-1008 96 CVLC-1009 97 CVLC-1010 97 CVLC-1011 97 CVLC-1012 97 CVLC-1013 98 CVLC-1014 98 CVLC-1015 98 CVLC-1016 99 CVLC-1017 99 CVLC-1018 99 CVLC-1019 99 CVLC-1020 100 CVLC-1021 100 CVLC-1022 100 Chapter 16 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 13
Fabric OS Message Reference 53-1001157-01 EM-1002 105 EM-1003 105 EM-1004 106 EM-1005 106 EM-1006 107 EM-1007 107 EM-1008 107 EM-1009 108 EM-1010 108 EM-1011 108 EM-1012 108 EM-1013 109 EM-1014 109 EM-1015 109 EM-1016 110 EM-1017 110 EM-1018 110 EM-1019 110 EM-1028 111 EM-1029 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 14
EM-1055 117 EM-1056 117 EM-1057 117 EM-1058 118 EM-1059 118 EM-1060 118 EM-1061 119 EM-1062 119 EM-1063 119 EM-1064 119 EM-1065 120 EM-1066 120 EM-1067 120 EM-1068 121 EM-1069 121 EM-1070 121 EM-2003 121 Chapter 18 ESS System Messages ESS-1001 123 ESS-1002 123 ESS-1003 123 ESS- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 15
FABR-1010 130 FABR-1011 130 FABR-1012 130 FABR-1013 131 FABR-1014 131 FABR-1015 131 FABR-1016 132 FABR-1017 132 FABR-1018 132 FABR-1019 132 FABR-1020 133 FABR-1021 133 FABR-1022 133 FABR-1023 134 FABR-1024 134 FABR-1029 134 FABR-1030 135 FABR-1031 135 FABR-1032 135 FABR-1034 136 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 16
FABS-1006 142 FABS-1007 142 FABS-1008 143 FABS-1009 143 FABS-1010 143 FABS-1011 143 FABS-1012 144 FABS-1013 144 FABS-1014 144 FABS-1015 145 Chapter 22 FBC System Messages FBC-1001 147 Chapter 23 FCIP System Messages FCIP-1000 149 FCIP-1001 149 FCIP-1002 149 FCIP-1003 149 FCIP-1004 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 17
Fabric OS Message Reference 53-1001157-01 FCR-1005 158 FCR-1006 158 FCR-1007 158 FCR-1008 158 FCR-1009 159 FCR-1010 159 FCR-1011 159 FCR-1012 160 FCR-1013 160 FCR-1015 160 FCR-1016 160 FCR-1018 161 FCR-1019 161 FCR-1020 161 FCR-1021 162 FCR-1022 162 FCR-1023 162 FCR-1024 163 FCR- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 18
FCR-1048 168 FCR-1049 168 FCR-1053 169 FCR-1054 169 FCR-1055 169 FCR-1056 170 FCR-1057 170 FCR-1058 170 FCR-1059 171 FCR-1060 171 FCR-1061 171 FCR-1062 171 FCR-1063 172 FCR-1064 172 FCR-1065 172 FCR-1066 173 FCR-1067 173 FCR-1068 173 FCR-1069 173 FCR-1070 174 FCR-1071 174 FCR- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 19
FCR-1088 179 FCR-1089 179 Chapter 28 FICON System Messages FICN-1003 181 FICN-1004 181 FICN-1005 182 FICN-1006 182 FICN-1007 182 FICN-1008 183 FICN-1009 183 FICN-1010 183 FICN-1011 183 FICN-1012 184 FICN-1013 184 FICN-1014 184 FICN-1015 185 FICN-1016 185 FICN-1017 185 FICN-1018 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 20
FICN-1036 190 FICN-1037 190 FICN-1038 191 FICN-1039 191 FICN-1040 191 FICN-1041 192 FICN-1042 192 FICN-1043 192 FICN-1044 192 FICN-1045 193 FICN-1046 193 FICN-1047 193 FICN-1048 194 FICN-1049 194 FICN-1050 194 FICN-1051 194 FICN-1052 195 FICN-1053 195 FICN-1054 195 FICN-1055 195 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 21
FICN-1073 200 FICN-1074 201 FICN-1075 201 FICN-1076 201 FICN-1077 202 FICN-1078 202 FICN-1079 202 FICN-1080 203 FICN-1081 203 FICN-1082 203 FICN-1083 204 FICN-1084 204 FICN-1085 204 FICN-1086 204 Chapter 29 FICU System Messages FICU-1001 205 FICU-1002 205 FICU-1003 205 FICU-1004 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 22
Chapter 32 FSPF System Messages FSPF-1001 213 FSPF-1002 213 FSPF-1003 213 FSPF-1005 214 FSPF-1006 214 Chapter 33 FSS System Messages FSS-1001 215 FSS-1002 215 FSS-1003 215 FSS-1004 216 FSS-1005 216 FSS-1006 216 FSS-1007 216 FSS-1008 217 FSS-1009 217 FSS-1010 217 FSS-1011 218 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 23
Fabric OS Message Reference 53-1001157-01 FW-1033 224 FW-1034 224 FW-1035 225 FW-1036 225 FW-1037 225 FW-1038 226 FW-1039 226 FW-1040 226 FW-1041 227 FW-1042 227 FW-1043 227 FW-1044 228 FW-1045 228 FW-1046 228 FW-1047 228 FW-1048 229 FW-1049 229 FW-1050 229 FW-1051 230 FW-1052 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 24
FW-1130 236 FW-1131 236 FW-1132 237 FW-1133 237 FW-1134 237 FW-1135 238 FW-1136 238 FW-1137 238 FW-1138 238 FW-1139 239 FW-1140 239 FW-1160 239 FW-1161 240 FW-1162 240 FW-1163 240 FW-1164 241 FW-1165 241 FW-1166 241 FW-1167 242 FW-1168 242 FW-1169 242 FW-1170 243 FW-1171 243 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 25
Fabric OS Message Reference 53-1001157-01 FW-1186 248 FW-1187 248 FW-1188 248 FW-1189 248 FW-1190 249 FW-1191 249 FW-1192 249 FW-1193 250 FW-1194 250 FW-1195 250 FW-1196 251 FW-1197 251 FW-1198 251 FW-1198 251 FW-1216 252 FW-1217 252 FW-1218 253 FW-1219 253 FW-1240 253 FW-1241 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 26
FW-1299 259 FW-1300 260 FW-1301 260 FW-1302 260 FW-1303 261 FW-1304 261 FW-1305 261 FW-1306 262 FW-1307 262 FW-1308 262 FW-1309 263 FW-1310 263 FW-1311 263 FW-1312 264 FW-1313 264 FW-1314 264 FW-1315 265 FW-1316 265 FW-1317 265 FW-1318 266 FW-1319 266 FW-1320 266 FW-1321 267 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 27
Fabric OS Message Reference 53-1001157-01 FW-1336 272 FW-1337 272 FW-1338 272 FW-1339 273 FW-1340 273 FW-1341 273 FW-1342 274 FW-1343 274 FW-1344 274 FW-1345 275 FW-1346 275 FW-1347 275 FW-1348 276 FW-1349 276 FW-1350 276 FW-1351 277 FW-1352 277 FW-1353 278 FW-1354 278 FW-1355 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 28
FW-1373 284 FW-1374 285 FW-1375 285 FW-1376 285 FW-1377 286 FW-1378 286 FW-1379 286 FW-1400 287 FW-1401 287 FW-1402 287 FW-1403 288 FW-1424 288 FW-1425 288 FW-1426 288 FW-1427 289 FW-1428 289 FW-1429 289 FW-1430 290 FW-1431 290 FW-1432 290 FW-1433 290 FW-1434 291 FW-1435 291 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 29
Chapter 36 HAM System Messages HAM-1001 297 HAM-1002 297 HAM-1004 297 HAM-1005 298 HAM-1006 298 HAM-1007 299 HAM-1008 299 HAM-1009 299 Chapter 37 HAMK System Messages HAMK-1001 301 HAMK-1002 301 HAMK-1003 301 HAMK-1004 302 Chapter 38 HIL System Messages HIL-1101 303 HIL-1102 303 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 30
HIL-1306 309 HIL-1307 309 HIL-1308 309 HIL-1309 310 HIL-1310 310 HIL-1311 310 HIL-1401 310 HIL-1402 311 HIL-1403 311 HIL-1404 311 HIL-1501 311 HIL-1502 312 HIL-1503 312 HIL-1504 312 HIL-1505 313 HIL-1506 313 HIL-1507 313 HIL-1508 314 HIL-1509 314 HIL-1510 314 HIL-1601 315 HIL- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 31
Chapter 42 IBD System Messages IBD-1001 323 Chapter 43 IBPD System Messages IBPD-1001 325 IBPD-1002 325 IBPD-1003 325 Chapter 44 ICPD System Messages ICPD-1001 327 ICPD-1002 327 ICPD-1003 327 ICPD-1004 327 ICPD-1005 328 ICPD-1006 328 ICPD-1007 328 ICPD-1008 328 Chapter 45 IPAD - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 32
ISNS-1005 338 ISNS-1006 338 ISNS-1008 338 ISNS-1009 339 ISNS-1010 339 ISNS-1011 339 ISNS-1013 339 ISNS-1014 340 Chapter 49 KAC System Messages KAC-1002 341 KAC-1004 341 KAC-1006 341 KAC-1007 341 KAC-1008 342 Chapter 50 KSWD System Messages KSWD-1001 343 KSWD-1002 343 KSWD-1003 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 33
LOG-1001 349 LOG-1002 349 LOG-1003 350 Chapter 54 LSDB System Messages LSDB-1001 351 LSDB-1002 351 LSDB-1003 351 LSDB-1004 352 Chapter 55 MFIC System Messages MFIC-1001 353 MFIC-1002 353 MFIC-1003 353 Chapter 56 MPTH System Messages MPTH-1001 355 MPTH-1002 355 MPTH-1003 355 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 34
Chapter 59 NBFS System Messages NBFS-1001 365 NBFS-1002 365 NBFS-1003 366 Chapter 60 NS System Messages NS-1001 367 NS-1002 367 NS-1003 367 NS-1004 368 NS-1005 368 NS-1006 368 Chapter 61 PDM System Messages PDM-1001 369 PDM-1002 369 PDM-1003 369 PDM-1004 370 PDM-1005 370 PDM-1006 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 35
PDTR-1002 377 Chapter 63 PLAT System Messages PLAT-1000 379 PLAT-1001 379 PLAT-1002 379 PLAT-1003 380 Chapter 64 PMGR System Messages PMGR-1001 381 PMGR-1002 381 PMGR-1003 381 PMGR-1004 381 PMGR-1005 382 PMGR-1006 382 PMGR-1007 382 PMGR-1008 382 PMGR-1009 383 PMGR-1010 383 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 36
Chapter 68 RAS System Messages RAS-1001 391 RAS-1002 391 RAS-1004 391 RAS-1005 391 RAS-1006 392 RAS-2001 392 RAS-2002 392 RAS-2003 392 RAS-3001 393 RAS-3002 393 RAS-3003 393 RAS-3004 393 Chapter 69 RCS System Messages RCS-1001 395 RCS-1002 395 RCS-1003 395 RCS-1004 396 RCS-1005 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 37
Chapter 72 RTWR System Messages RTWR-1001 403 RTWR-1002 403 RTWR-1003 404 Chapter 73 SAS System Messages SAS-1001 405 Chapter 74 SCN System Messages SCN-1001 407 Chapter 75 SEC System Messages SEC-1001 409 SEC-1002 409 SEC-1003 410 SEC-1005 410 SEC-1006 410 SEC-1007 411 SEC-1008 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 38
xxxviii SEC-1042 417 SEC-1043 417 SEC-1044 417 SEC-1045 417 SEC-1046 418 SEC-1049 418 SEC-1050 418 SEC-1051 419 SEC-1052 419 SEC-1053 419 SEC-1054 420 SEC-1055 420 SEC-1056 420 SEC-1057 421 SEC-1059 421 SEC-1062 421 SEC-1063 421 SEC-1064 422 SEC-1065 422 SEC-1069 422 SEC-1071 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 39
Fabric OS Message Reference 53-1001157-01 SEC-1088 427 SEC-1089 427 SEC-1090 428 SEC-1091 428 SEC-1092 428 SEC-1093 428 SEC-1094 429 SEC-1095 429 SEC-1096 429 SEC-1097 430 SEC-1098 430 SEC-1099 430 SEC-1100 430 SEC-1101 431 SEC-1102 431 SEC-1104 431 SEC-1105 432 SEC-1106 432 SEC- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 40
SEC-1136 437 SEC-1137 438 SEC-1138 438 SEC-1139 438 SEC-1142 439 SEC-1145 439 SEC-1146 439 SEC-1153 440 SEC-1154 440 SEC-1155 440 SEC-1156 441 SEC-1157 441 SEC-1158 441 SEC-1159 442 SEC-1160 442 SEC-1163 442 SEC-1164 442 SEC-1165 443 SEC-1166 443 SEC-1167 443 SEC-1168 443 SEC- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 41
Fabric OS Message Reference 53-1001157-01 SEC-1189 448 SEC-1190 449 SEC-1191 449 SEC-1192 449 SEC-1193 449 SEC-1194 450 SEC-1195 450 SEC-1196 450 SEC-1197 451 SEC-1198 451 SEC-1199 451 SEC-1200 451 SEC-1201 452 SEC-1202 452 SEC-1203 452 SEC-1250 453 SEC-1251 453 SEC-1253 453 SEC- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 42
SEC-1319 459 SEC-1320 459 SEC-1321 459 SEC-1322 460 SEC-1323 460 SEC-1324 460 SEC-1325 460 SEC-1326 461 SEC-1327 461 SEC-1328 461 SEC-1329 462 SEC-1330 462 SEC-1331 462 SEC-1332 462 SEC-1333 463 SEC-3035 463 SEC-3036 463 SEC-3037 464 SEC-3038 464 SEC-3039 464 SEC-3050 464 SEC- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 43
SPC-2001 472 SPC-2002 472 SPC-2003 472 SPC-2004 472 SPC-2005 473 SPC-2006 473 SPC-2007 473 SPC-2008 473 SPC-2009 474 SPC-2010 474 SPC-2011 474 SPC-2012 474 SPC-3001 475 SPC-3002 475 SPC-3003 475 SPC-3004 475 SPC-3005 476 SPC-3006 476 SPC-3007 477 SPC-3008 477 SPC-3009 477 SPC- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 44
SPM-1009 483 SPM-1010 483 Chapter 79 SS System Messages SS-1000 485 SS-1001 485 SS-1002 485 SS-1003 486 Chapter 80 SULB System Messages SULB-1001 487 SULB-1002 487 SULB-1003 487 SULB-1004 488 SULB-1005 488 SULB-1006 488 SULB-1007 488 SULB-1008 489 SULB-1009 489 SULB-1010 495 SULB - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 45
SULB-1037 500 Chapter 81 SWCH System Messages SWCH-1001 501 SWCH-1002 501 SWCH-1003 501 SWCH-1004 502 SWCH-1005 502 SWCH-1006 502 SWCH-1007 502 SWCH-1008 503 SWCH-1009 503 SWCH-1010 503 SWCH-1011 504 Chapter 82 SYSC System Messages SYSC-1001 505 SYSC-1002 505 SYSC-1003 505 SYSC- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 46
TRCE-1004 512 TRCE-1005 512 TRCE-1006 512 TRCE-1007 513 TRCE-1008 513 TRCE-1009 513 TRCE-1010 513 TRCE-1011 514 TRCE-1012 514 Chapter 86 TRCK System Messages TRCK-1001 515 TRCK-1002 515 TRCK-1003 515 TRCK-1004 515 TRCK-1005 516 TRCK-1006 516 Chapter 87 TS System Messages TS-1001 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 47
WEBD-1002 525 WEBD-1004 525 WEBD-1005 525 WEBD-1006 526 WEBD-1007 526 WEBD-1008 526 Chapter 91 ZOLB System Messages ZOLB-1001 527 Chapter 92 ZONE System Messages ZONE-1002 529 ZONE-1003 529 ZONE-1004 529 ZONE-1005 530 ZONE-1006 530 ZONE-1007 531 ZONE-1008 531 ZONE-1010 531 ZONE- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 48
ZONE-1034 537 ZONE-1035 537 ZONE-1036 537 ZONE-1037 538 ZONE-1038 538 ZONE-1039 538 ZONE-1040 538 ZONE-1041 539 ZONE-1042 539 ZONE-1043 539 ZONE-1044 539 ZONE-1045 540 ZONE-1046 540 ZONE-1047 540 ZONE-1048 540 ZONE-1049 541 ZONE-1050 541 ZONE-1051 541 ZONE-1052 541 ZONE-1053 542 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 49
CONF-1020 551 CONF-1022 551 Chapter 92 AUDIT FCIP System Messages FCIP-1002 553 FCIP-1003 553 Chapter 93 AUDIT FICU System Messages FICU-1011 555 FICU-1012 555 Chapter 94 AUDIT FW System Messages FW-3001 557 Chapter 95 AUDIT HTTP System Messages HTTP-1002 559 HTTP-1003 559 Chapter - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 50
SEC-3012 568 SEC-3013 568 SEC-3014 569 SEC-3015 569 SEC-3016 569 SEC-3017 570 SEC-3018 570 SEC-3019 570 SEC-3020 570 SEC-3021 571 SEC-3022 571 SEC-3023 571 SEC-3024 572 SEC-3025 572 SEC-3026 572 SEC-3027 572 SEC-3028 573 SEC-3029 573 SEC-3030 573 SEC-3031 574 SEC-3032 574 SEC- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 51
SEC-3051 578 Chapter 99 AUDIT SNMP System Messages SNMP-1004 579 SNMP-1005 579 SNMP-1006 579 Chapter 100 AUDIT SULB System Messages SULB-1001 581 SULB-1002 581 SULB-1003 581 SULB-1004 582 SULB-1009 582 SULB-1010 588 SULB-1017 588 SULB-1018 588 SULB-1020 589 SULB-1021 589 SULB-1023 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 52
UCST-1024 596 UCST-1025 596 UCST-1026 596 UCST-1027 596 Chapter 103 AUDIT ZONE System Messages ZONE-3001 599 ZONE-3002 599 ZONE-3003 599 ZONE-3004 600 ZONE-3005 600 ZONE-3006 600 ZONE-3007 601 ZONE-3008 601 ZONE-3009 601 ZONE-3010 601 ZONE-3011 602 ZONE-3012 602 ZONE-3013 602 ZONE- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 53
hardware and software In those instances in which procedures or parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware configurations are tested and - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 54
• Brocade 4018 switch • Brocade 4020 switch • Brocade 4024 switch • Brocade 4100 switch • Brocade 4900 switch • Brocade 5000 switch • Brocade 5100 switch • Brocade 5300 switch • Brocade 7500 Extension Switch • Brocade 7500E Extension Switch • Brocade 7600 switch • Brocade 48000 director • Brocade - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 55
command names Identifies the names of user-manipulated GUI elements Identifies keywords and in the narrative portions of this guide are presented in mixed lettercase: for sensitive. Command syntax conventions Command syntax in this manual follows these conventions: command --option, option - - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 56
, or data. DANGER A Danger statement indicates conditions or situations that can be potentially lethal or extremely hazardous to you. Safety labels are also attached directly to products to warn of these conditions or situations. Key terms For definitions specific to Brocade and Fibre Channel, see - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 57
resources For information about the Fibre Channel industry, visit the Fibre Channel Industry Association Web site: http://www.fibrechannel.org Getting technical help Contact your switch support supplier for hardware, firmware, and software support, including product repairs and part ordering - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 58
• Brocade DCX-4S-On the bottom right on the port side of the chassis, directly above the cable management comb. 3. World Wide Name (WWN) Use the wwn command to display the switch WWN. • If you cannot use the wwn command because the switch is inoperable, you can get the WWN from the same place as the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 59
13 Overview of System Messages This guide supports Fabric OS v6.2.0 and documents system messages that can help you diagnose and fix problems with a switch or fabric. The messages are organized first by event type, reliability, availability, and serviceability log (RASLog) or AUDIT, and then - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 60
is particularly important for dual-domain switches because the support post-event audits and problem determination based on high-frequency events of certain types such as security violations, zoning configuration changes, firmware Security You can audit any user-initiated security event for all - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 61
auditCfg command (the classes include zone, security, configuration, firmware, and fabric). The defined set of Audit messages Linux, or any other operating system that supports the standard syslogd functionality. Configuring for syslogd involves Guide. Fabric OS Message Reference 3 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 62
-to-switch, some device A-to-device B, and control information. Port logs are not persistent and are lost Guide for information on interpreting results of the portLogDump command. Port log functionality is completely separate from the system message log. Port logs are typically used to troubleshoot - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 63
errClear Clears all error log messages for all switch instances on this control processor (CP). errDelimterSet Sets the error log start and end delimiter module within the Fabric OS. supportFtp Sets, clears, or displays support FTP parameters or a time interval to check the FTP server. Fabric - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 64
and disables FFDC (first failure data capture). supportSave Collects RASLog, trace is used by your switch service provider to diagnose and correct problems with the switch. The output displays. 4. View the switch events and messages. In dual-domain switches, an Event button exists for each logical - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 65
Viewing and Configuring System Message Logs 1 2004/07/28-17:04:51, [EM-1055], 3,, WARNING, switch, Media 27: Port media incompatible. Reason: Configured port speed. 2004/07/28-17:04:54, [FABR-1001], 4,, WARNING, switch, port 4, ELP rejected by the other switch 2004/07/28-17:05:06, [FW-1050], 5,, - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 66
is enabled. 1-ZONE 2-SECURITY 3-CONFIGURATION 4-FIRMWARE 5-FABRIC 3. Enable the audit feature: on the switch. The RASLog subsystem supports an internationalized timestamp format base on the reference the cause and actions recommended in this manual. Note that not all message numbers are used - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 67
is for a security issue. FFDC indicates that additional first failure data capture information has also been generated for this event. AUDIT:FFDC flagged as AUDIT provide additional user and system-related information of interest for post event auditing and problem determination. Audit event message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 68
on the switch. The RASLog subsystem will support an internationalized timestamp format base on the the cause and actions recommended in this manual. Note that not all message numbers are : Zone Security Configuration Firmware Fabric User ID The user ID. Role The role of the user ID. IP Address - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 69
be used as general guidelines for troubleshooting. For all cases, you should •Gathering Information About the Problem 12 •Support 12 •Panic Dump and Core Dump Files 12 •Trace Dumps 13 •supportSave Command 13 Looking Up a System Message Error messages in this manual - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 70
DCX, 12000, 24000, or 48000) 13. What and when were the last actions or changes made to the system? Support Fabric OS creates a number of files that can help support personnel troubleshoot and diagnose a problem. This section describes those files and how to access and/or save the information for - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 71
and core files are intended for support personnel use only. Trace Dumps The Fabric OS produces trace dumps when problems are encountered within Fabric OS the system modules for which messages are documented in this reference guide; the system modules are listed alphabetically by name. TABLE 5 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 72
fabric. Fabric OS system driver module. Firmware blade compatibility errors with control processor (CP). Fibre Channel over IP port configuration messages. Fibre Channel miscellaneous messages relate to problems with the physical layer used to send Fibre Channel traffic to and from the switch. 14 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 73
Fibre Channel router-related traffic and activity on the fabric or backend fabric. The FICN-1xxx and FICN-5yyy messages are generated during FICON emulation processing on an FCIP Tunnel. FICU-#### messages indicate that something has occurred which affects the control is a user space daemon - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 74
Fibre Channel over IP license, tunneling, and port-related messages. The ISCS module is the FabOS component that performs system-level control daemon (diagd) • Environment Monitor (emd) • EVM daemon (evmd) • Exchange Service Support daemon (essd) • FA-API rpc daemon (rpcd) • Fabric daemon (fabricd) - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 75
Service enables the user to obtain information about the Fibre Channel fabric topology and attributes by providing a single management access point. MS provides for both monitoring and control Full (5). Indicates problems with the simple name server module. Parity data manager is a user space daemon - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 76
helps deliver data messages services supporting director-class storage virtualization firmware download. For additional information, refer to the Fabric OS Administrator's Guide. These messages are generated by the switch driver module that manages a Fibre Channel switch instance. System controller - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 77
to the Fabric OS Command Reference or the Fabric OS Administrator's Guide. Time Service provides fabric time-synchronization by synchronizing all clocks in the fabric problems with the Web Tools module. Indicates problems with the zone library module. The zone module messages indicate any problems - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 78
1 System Module Descriptions 20 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 79
RASLog Messages Section I This section provides the RASLog messages, including: •AG System Messages 25 •AUTH System Messages 33 •BKSW System Messages 47 •BL System Messages 49 •BLL System Messages 63 •BM System Messages 65 •C2 System Messages 71 •CDR System Messages 73 •CER System Messages - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 80
•FSS System Messages 215 •FSSM System Messages 219 •FW System Messages 221 •HAM System Messages 297 •HAMK System Messages 301 •HIL System Messages 303 •HLO System Messages 317 •HMON System Messages 319 •HTTP System Messages 321 •IBD System Messages 323 •IBPD System Messages 325 •ICPD - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 81
•RTWR System Messages 403 •SAS System Messages 405 •SCN System Messages 407 •SEC System Messages 409 •SNMP System Messages 467 •SPC System Messages 471 •SPM System Messages 481 •SS System Messages 485 •SULB System Messages 487 •SWCH System Messages 501 •SYSC System Messages 505 •SYSM - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 82
- HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 83
virtualization (NPIV) is not supported by fabric port connected to port . Probable Cause N_Port ID virtualization (NPIV) capability is not supported manual for more information on this command. • Some blades and ports in a switch may not support contact your switch service provider. Severity - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 84
(FLOGI) request from the fabric for N_Port . Probable Cause Indicates the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the specified N_Port. Recommended Action Check the configuration of the fabric switch. If the message persists, run supportFtp (as needed - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 85
the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING AG-1009 Message , [AG-1009], ,, WARNING, , Sending FLOGI failed on N_Port - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 86
message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING AG-1013 Message , [AG-1013], ,, INFO, , F_Ports mapped to N_Port failed over - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 87
message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportsave command and contact your switch service provider. Severity WARNING AG-1016 Message , [AG-1016], ,, INFO, , Failing over F_Ports mapped to N_Port - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 88
to failover N_Port . No other N Port in port group: is online. Probable Cause Indicates that failover across port groups is not supported. Recommended Check whether or not an alternate N_Port is configured in this port group. Action Severity WARNING AG-1020 Message , [AG - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 89
AG-1023 2 Probable Cause Indicates the specified F_Port is failing over to its preferred N_Port. Recommended Run ag --mapshow to display the updated F_Port-to-N_Port mapping. Action Severity INFO AG-1023 Message , [AG-1023], ,, INFO, , F_Port - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 90
automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING AG-1027 Message , [AG-1027], < have login access for that port, as per ADS policy set by the user. Recommended Add the device in to the ADS allow list for that port - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 91
up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1003 Message , [AUTH-1003], ,, INFO, , type has been successfully set to . Probable Cause Indicates that - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 92
authentication configuration value. The data type is either " and contact your switch service provider. Severity ERROR AUTH to reinstall the firmware. Run supportFtp internal problem with supported: port . Indicates that the proposed authentication protocol type or types are not supported - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 93
switch supports the specified protocols: Fibre channel authentication the security license is installed using the licenseShow code>. Probable Cause Indicates an internal problem with the Secure Fabric OS. Recommended command and contact your switch service provider. Severity ERROR AUTH-1011 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 94
support authentication. Recommended Make sure the entity at the other end of the link supports Recommended Action Usually this problem is transient. The authentication then run the supportSave command and contact your switch service provider. Severity WARNING AUTH-1014 Message , [ - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 95
code . Probable Cause Indicates an internal problem with the Secure Fabric OS. Recommended Action Reinitialize automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1018 Message , [AUTH-1018], < - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 96
, , Failed to extract from payload: port Action Usually this problem is transient. The run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1023 Message , operations for fibre channel authentication protocol - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 97
name>, Failed to get during : Usually this problem is transient. command and contact your switch service provider. Severity WARNING AUTH-1027 support the specified authentication value. Recommended Check the authentication configuration and reset the supported - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 98
phase. Data type is the payload or structure that failed to get memory. Recommended Action Usually this problem is transient automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1030 Message , [AUTH-1030], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 99
data) for an authentication payload. This usually relates to internal failure. A nonce is a single-use, usually random value used in authentication protocols to prevent replay attacks. Recommended Action Usually this problem command and contact your switch service provider. Severity ERROR AUTH- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 100
configured in the switch connection control (SCC) policy and tried service provider. Severity ERROR AUTH-1035 Message , [AUTH-1035], ,, ERROR, , Invalid length in message: length - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 101
then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1037 Message , for : init_len , resp_len , port . PKI) certificate is not installed properly. Recommended Action Reinstall - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 102
message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1042 Message Probable Cause , [AUTH-1042], ,, ERROR, , Port has - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 103
run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1043 Message < setting the device authentication policy manually using the authUtil command. specified port has been disabled as a result. This problem may be transient due to the system's central processing - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 104
3 AUTH-1044 46 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 105
specific information. The switch will reboot (on single-CP switches) or fail over (on dual-CP switches). The warning message will be one of the following: • - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 106
4 BKSW-1003 48 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 107
the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Note that any reference seen to slot 0 is a reference to the blade within the switch platform, e.g.,Brocade 7500 and AP7600 contain FR4-18i and - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 108
blade. Run the systemVerification command to verify that blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is blade experienced a failure but was not faulted due to a user setting. Recommended Action Reboot or power cycle the blade, using the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 109
. Probably, the standby control processor (CP) blade connected to the active CP blade has experienced transitory problems. Recommended Use the haShow command to verify that the standby CP is healthy. If the standby CP was removed Action or faulted by user - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 110
Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test ( is too many abnormal frames; the chip is disabled to prevent the control processor (CP) from becoming too busy. Recommended Action Make sure to - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 111
might prove unrecoverable to the switch operation. The port is disabled to prevent the control processor (CP) from becoming too busy. The bport is the blade port; this number might not correspond to a user port number. Recommended Action Make sure to capture the console output during this process - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 112
The port is disabled to prevent the CP from becoming too busy. The bport is the blade port; this number might not correspond to a user port number. Recommended Action Make sure to capture the console output during this process. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 113
If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 114
The switch is faulted. Recommended Action Reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 115
will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all GigE/Fibre Channel over IP (FCIP) Virtualization data elements were reset. Recommended No - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 116
ensure Action Power-On Self-Test (POST) is enabled. If problem persists, replace switch. Severity CRITICAL BL-1027 Message , as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded and - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 117
firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all the GigE/Fibre Channel over IP (FCIP)/Virtualization data control flags -user) hardware problems. Run - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 118
user ports after disabling the ports. Recommended Action Reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems Indicates that the indicated slot has completed initializing Fibre Channel (FC) ports. Recommended No action is - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 119
BL-1037 5 BL-1037 Message , [BL-1037], ,, CRITICAL, , Faulting chip in slot = , miniS = ,port = due to BE/BI port fault. Probable Cause Fault the chip and disable all the ports on that chip. Recommended No action - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 120
5 BL-1037 62 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 121
as faulty (reason: ) Probable Cause Indicates a blade regulation problem was reported on the specified slot number. The blade is faulted. The command to verify that the blade does not have hardware problems. Refer to the Fabric OS Command Reference for more information on - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 122
6 BLL-1000 If the message persists, replace the blade. Severity CRITICAL 64 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 123
problem can be corrected by changing the firmware version on either the control processor (CP) or on the application processor (AP) blade. The firmware firmware download is supported between the versions. As the AP and CP blades cannot communicate, it is not possible to load new firmware on - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 124
of the specified blade is to auto-level the blade firmware to the system firmware. The reason for the inconsistency may be either of the following: • Blade firmware was detected to be different from the control processor (CP) firmware due to a firmware upgrade. • The blade was just inserted and had - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 125
to recover. Probable Cause Indicates the automatic firmware upgrade on the blade has failed, because the blade firmware version was detected to be different from the control processor (CP) firmware version due to a firmware upgrade. Recommended Issue the firmwareDownload command to - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 126
and Application Processor. Faulting switch. Probable Cause Indicates the control processor (CP) could not establish a connection to the -name>, AP firmware is not consistent with system firmware . Auto-leveling AP firmware to match system firmware. Probable Cause - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 127
upgrade on the application processor (AP) has failed, because the firmware version running on the AP was detected to be different from the system firmware because of a firmware upgrade. Recommended Issue the firmwareDownload command to recover the AP. Action Severity WARNING Fabric OS Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 128
7 BM-1058 70 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 129
port fault (the configured speed may not be supported by the SFP). Please change the SFP or have not Action deteriorated and the Fibre Channel cable is not faulty. Replace SFPs data traffic. Recommended Whenever this error is observed, reboot the system at the next maintenance window. If the problem - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 130
8 C2-1005 C2-1005 Message , [C2-1005], ,, ERROR, , Rate limit configuration is not effective on S() user port because QoS license is not present. Probable Cause Indicates that the switch does not have the QoS license added. Rate - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 131
the peer ports. Verify that the SFPs have not deteriorated and that the Fibre Channel cable is not faulty. Replace the SFPs or cable if necessary. If there may degrade data traffic. Recommended Whenever this error occurs, reboot the system at the next maintenance window. If the problem Action - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 132
name>, , : invalid DMA ch pointer, chan:, good_addr:0x, bad_addr:0x. Probable Cause may degrade data traffic. Recommended Whenever this error occurs, reboot the system at the next maintenance window. If the problem Action persists - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 133
(HA) synchronization between the active and standby control processors (CPs) is broken, because there is downlevel firmware loaded on the standby CP. The standby CP does not support the Advanced Performance Tuning module when the fibre connectivity (FICON) Management Server is enabled. Recommended - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 134
10 CER-1001 76 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 135
Chapter CHASSIS System Messages 11 CHASSIS-1002 Message , [CHASSIS-1002], ,, ERROR, , ki_gd_register_action failed with rc =. Probable Cause Indicates an internal error. Recommended Action For a bladed system, run the slotPowerOff command and - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 136
11 CHASSIS-1005 CHASSIS-1005 Message , [CHASSIS-1005], ,, ERROR, , Diag attach failed during recovery, disabling slot = . Probable Cause Indicates that the Diag blade attach has failed during failover or recovery. Recommended Action On a - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 137
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on cryptodevicecfg command. Refer to the Action Fabric OS Command Reference Manual for more information on this command. Severity WARNING CNM-1004 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 138
12 CNM-1005 Probable Cause Indicates that the Crypto service is enabled or disabled on the switch. Recommended No action is required. Action Severity INFO CNM-1005 Message , [CNM-1005], ,, INFO, - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 139
,, INFO, , Posting event CNM_EVT_CLUSTER_UDATA_UPDATE cid [], ulen []. Probable Cause Indicates the client data update. Recommended No action is required. Action Severity INFO CNM-1011 Message , [CNM-1011], ,, INFO - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 140
Message , [CNM-1014], ,, INFO, ,Posting event Node Admission Control passed, admitting node []. Probable Cause Indicates that the Node Admission Control was successful. Recommended No action is required. Action Severity INFO CNM-1015 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 141
certificate. Recommended No action is required. Action Severity INFO CNM-1020 Message , [CNM-1020], ,, INFO, , Node Admission Control failed, due to mismatch in certificates, rejecting node []. Fabric OS Message Reference 83 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 142
[CNM-1021], ,, INFO, , Failed to sign the node authentication message, admission control might fail. Probable Cause Indicates Node Admission Control failed. Recommended No action is required. Action Severity INFO CNM-1022 Message , [CNM-1022], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 143
sequence-number>,, INFO, , Received HBT Message with version mismatch, Received Hdr version Expected Hdr version Upgrade the firmware or delete the Node [] from the EG. Probable Cause Indicates an operation is not required. Recommended No action is required - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 144
12 CNM-1029 Probable Cause Indicates that the certificate file for the node already exists. Recommended No action is required. Action Severity INFO CNM-1029 Message , [CNM-1029], ,, INFO, , Certfile content does not match the cert sent by GL. - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 145
12 CNM-1033 Probable Cause Indicates that there is a size mismatch between a node's certificate file and the certificate file received from the group leader. Recommended No action is required. Action Severity INFO CNM-1033 Message , [CNM-1033], ,, INFO, , - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 146
12 CNM-1037 Probable Cause Indicates an event is being posted to indicate the cluster is in a converged state. Recommended No action is required. Action Severity INFO CNM-1037 Message , [CNM-1037], ,, INFO, , Split-Brain Arbitration lost!, minority GL - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 147
12 CNM-1041 Recommended No action is required. Action Severity INFO CNM-1041 Message , [CNM-1041], ,, INFO, , Updating persistent Cluster DB, please avoid powering off the switch. Probable Cause Indicates the system is updating the persistent database. - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 148
12 CNM-1044 Recommended No action is required. Action Severity INFO 90 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 149
Chapter CONF System Messages 13 CONF-1000 Message , [CONF-1000], , AUDIT, INFO, , configDownload completed successfully. . Probable Cause Indicates that the configDownload operation was initiated and completed - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 150
INFO CONF-1030 Message , [CONF-1030], ,, WARNING, , Configuration database full, data not committed (key:. Probable Cause Indicates that the previous configuration commands have resulted in a database full condition - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 151
Chapter CTAP System Messages 14 CTAP-1001 Message , [CTAP-1001], ,, INFO, , Key acquisition for . Probable Cause Indicates that a change in the tape pool database has triggered the key acquisition process for each - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 152
14 CTAP-1001 94 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 153
, Initiator: , LUN ID: . Probable Cause Indicates the First time encryption, Key expired or Manual re-key operation is performed. The operation has been started, completed or cancelled. Recommended No action is required. Action Severity INFO - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 154
15 CVLC-1004 CVLC-1004 Message , [CVLC-1004], ,, INFO, , Forceful encryption LUN removal while re-key session is still active.\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates that the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 155
15 CVLC-1009 Severity ERROR CVLC-1009 Message , [CVLC-1009], ,, ERROR, , Wrong device type: should be , found .\nContainer: , Initiator: , - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 156
1014], ,, ERROR, , Missing Key ID from user input.\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates that the data state in the LUN configuration is in the Encrypted state without a key - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 157
is clear text.\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates that the data state in the LUN configuration is in clear text state but metadata exists on the LUN. Recommended Use cryptocfg command to confirm the configuration - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 158
is required. Action Severity INFO CVLC-1022 Message , [CVLC-1022], ,, INFO, , User provided key ID is ignored while data state is clear text.\nContainer: , Initiator: , LUN ID: - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 159
Indicates that an initialization of a module within the CVLMD failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR CVLM-1003 Message , [CVLM - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 160
INFO, , Crypto service is on the switch. Probable Cause Indicates that the Crypto service is enabled or disabled on crypto device into AD0. Refer to the Fabric OS Command Action Reference Manual for more information on this command. Severity WARNING CVLM-1007 Message < - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 161
16 CVLM-1009 Probable Cause Indicates that the member of HAC is not in the fabric. Recommended Check the ISL port connected to the fabric. Action Severity WARNING CVLM-1009 Message , [CVLM-1009], ,, INFO, , The member ( ) of HAC - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 162
16 CVLM-1012 Recommended No action is required. Action Severity INFO 104 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 163
to the console. Recommended Action Verify that the location temperature is within the operational range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Run the fanShow command to verify that all fans are running at normal speeds. If - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 164
. Make sure there are no blockages of the airflow around the chassis. If the temperature problem is isolated to the blade itself, replace the blade. Voltage problems on a blade are likely a hardware problem on the blade itself; replace the blade. Severity CRITICAL 106 Fabric OS Message Reference - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 165
switch for nonbladed switches. Recommended Action There is most likely a voltage hardware problem on the blade or motherboard of the switch. For the Brocade DCX, the blade and ensure the replacement blade is compatible with your control processor (CP) type. If the incompatibility is with the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 166
the FRU. If the message persists, replace the FRU. Refer to the Brocade 48000 Hardware Reference Manual for more information about chassisConfig modes and supported blades. Severity CRITICAL EM-1010 Message , [EM-1010], , FFDC, CRITICAL, , Received - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 167
the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command Reference for more information on to update the time alive or the original equipment manufacturer (OEM) data in the memory on a field-replaceable unit (FRU). Recommended Action - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 168
Cause Indicates that a problem was discovered when and contact your switch service provider. Severity WARNING EM Probable Cause Indicates that a user did not commit a changed system. Recommended Verify that the control processor (CP) blade is compatible with standby firmware version (Pre 4.4), cannot - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 169
that the current chassisConfig option is not supported by the firmware on the standby control processor (CP). This is true even if log for FRU: (rc=). Probable Cause Indicates a problem accessing the data on the world wide name (WWN) card field-replaceable unit (FRU) or the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 170
hardware manual for instructions on inserting the switch blades. Severity ERROR EM-1033 Message , [EM-1033], ,, ERROR, , CP in set to faulty because CP ERROR asserted Probable Cause Indicates that the standby control problems - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 171
Switch side value indicates: • left: controls the odd numbered power supply units. • right: controls the even numbered power supply units. systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command Reference for more information on - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 172
recommended action for those messages. Severity WARNING EM-1042 Message , [EM-1042], ,, WARNING, , Important FRU header data for is not valid). Probable Cause Indicates that the specified field-replaceable unit (FRU) has an incorrect number of - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 173
for that platform (CP) type. Remove the blade from the chassis. If the reason is due to backplane, the CP type (CP256) is not supported on that chassis (backplane revision D2), remove the blade from the chassis. If the reason is switch configuration, the blade's Logical switch configuration is not - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 174
17 EM-1048 Probable Cause Indicates that the control processor (CP) is no longer faulted. This has become available again. Recommended The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is Action displayed. Severity INFO EM-1049 Message , [EM - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 175
media can be run at the configured port speed. If the port media is extended long wavelength, move it to a port that can support the heat generated. Severity WARNING EM-1056 Message , [EM-1056], ,, WARNING, , : Port faulted. Reason: - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 176
is being automatically reset because of a known resetable transient problem such as an application-specific integrated circuit (ASIC) parity error Cause Indicates a blade in the system is not supported by the release on the standby control processor (CP). Recommended Action Remove all blades - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 177
Probable Cause Indicates a blade in the system is not supported by the release on the standby control processor (CP). Recommended Action Remove all blades of -name>, Blade: is being powered off (based on user configuration) upon receiving a HW ASIC ERROR, reason:. Fabric - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 178
, , SSAS Virtualization Services are not available due to incompatibility between the FOS and SAS versions. Probable Cause Indicates the version of either the control processor firmware (CFOS) or the blade processor firmware (BFOS) is not - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 179
-1068], ,, ERROR, , High Availability Service Management subsystem failed to respond. A required component is not operating in other messages or debug data. There are serious internal Fabric OS configuration or hardware problems on the switch. Recommended Reboot - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 180
persists: • Run the systemverification command to verify that the switch does not have hardware problems. Refer to theFabric OS Reference Manual for more information on this command. • On bladed systems, replace the specified FRU; otherwise replace the switch. Severity ERROR 122 Fabric OS Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 181
. Probable Cause Indicates one or more switches in the fabric do not support the Coordinated HotCode protocol. Continuing with the firmware download may cause data traffic disruption. Recommended Action Discontinue the firmware download, identify the downlevel switch or switches that do not - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 182
HotCode protocol, a switch in the fabric did not accept the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to this issue. Recommended No action is required. Action Severity WARNING 124 Fabric OS - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 183
Chapter EVMD System Messages 19 EVMD-1001 Message , [EVMD-1001], ,, WARNING, , Event could not be sent to remote proxy. = Probable Cause Indicates the event could not be sent to remote proxy. This could happen if the remote - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 184
19 EVMD-1001 126 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 185
wanted . Probable Cause Indicates that an internal link service (ILS) information unit of invalid size has been received. The with an invalid size. Recommended Action Investigate the neighbor switch for problems. Run the errShow command on the neighbor switch to view the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 186
FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FABR-1004 Message , [FABR-1004], a one-time event because of the incoming data, the system will discard the frame. If it is due to problems with the kernel, the system will recover - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 187
FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FABR-1007 Message , [FABR-1007], information unit. This message is rare and usually indicates a problem with the Fabric OS. Recommended Action In case of severe memory - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 188
stable or unstable. This message is rare and usually indicates a problem with the Fabric OS. Recommended If the message persists, run supportFtp transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR FABR-1012 Message , [FABR-1012 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 189
This message is rare and usually indicates a problem with the Fabric OS. Recommended Action The system the supportSave command and contact your switch service provider. Severity CRITICAL FABR-1014 Message from the insistent domain ID (IDID). Fibre connectivity (FICON) mode requires an insistent - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 190
Indicates that FICON mode is disabled on the switch through a user interface command. Recommended No action is required. Action Severity WARNING -name>, Critical fabric size () exceeds supported configuration (). 132 Fabric OS Message Reference 53-1001157 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 191
FABR-1022 Message , [FABR-1022], , FFDC, CRITICAL, , Fabric size () exceeds supported configuration (). Fabric limit timer () started from . Fabric OS Message Reference 133 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 192
-number>,, INFO, , Fabric size is within supported configuration (). Fabric limit timer () stopped at negotiated (mode = ). Indicates that a different flow control mode, as described in the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 193
Virtual-channel flow control mode. This is a proprietary protocol. • R_RDY mode: Receiver-ready flow control mode. This is the Fibre Channel standard protocol, that uses R_RDY primitive for flow control. • DUAL_CR mode: Dual-credit flow control of retries sending internal link service (ILS) to the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 194
cable to a port to match with the same Master Trunk Area, or disable Trunk Area. You must manually enable the port or the port remains disabled forever. Refer to the Admin Guide for more information. Severity INFO FABR-1036 Message , [FABR-1036], , INFO, - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 195
Probable Cause Indicates the specified port is being disabled because F_port trunking is enabled without a trunking license being present. Recommended Install a trunking license or disable F_port trunking on the port. Action Severity INFO FABR-1039 Message , [FABR-1039], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 196
FTP transfers followed by the supportSave command and contact your switch service provider. Severity ERROR FABR-1043 Message , [FABR-1043 have the same Fabric ID or upgrade the switch Action firmware to a VF-capable firmware. Severity ERROR FABR-1044 Message , [FABR-1044 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 197
conflicting switch are disabled. Recommended Make sure that all the switches in the fabric have the same Base Switch attribute or upgrade the Action switch firmware to a VF-capable firmware. Severity ERROR Fabric OS Message Reference 139 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 198
20 FABR-1046 140 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 199
the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1004 Message , [FABS-1004], ,, WARNING, , process () - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 200
a serious Fabric OS data problem on the switch. The possible values for function name and description of problem are: • setSoftState: bad If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1007 Message , [FABS-1007], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 201
an unknown event type. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1011 Message Probable Cause , [FABS- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 202
run the firmwareDownload command to update the firmware. Severity ERROR FABS-1013 Message < FRU header, or the blade may not be supported by this platform or Fabric OS version. Recommended a valid blade and reseating does not fix the problem, then replace the blade. Severity ERROR FABS-1014 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 203
number> failed. err code Probable Cause Indicates the specified FRU could not be enabled. This is usually an internal Fabric OS problem. Recommended Action Try removing and reinserting the FRU. Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 204
21 FABS-1015 146 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 205
a non-disruptive firmwareDownload is supported between the versions. As the AP and CP blades cannot communicate, it is not possible to load new firmware on the AP blade. If required, send the AP blade back to the factory to get a new firmware version installed. Severity ERROR Fabric OS Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 206
22 FBC-1001 148 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 207
Message , [FCIP-1000], , FFDC, ERROR, , of GE failed. Please retry the command. Data: inst= st= rsn= fn= oid= Probable Cause Indicates that the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 208
-1004 Message , [FCIP-1004], , INFO, CFG, , Tape Read Pipelining is being disabled slot () port () tunnel (). Probable Cause Indicates that the FOS version on the remote end of the tunnel does - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 209
Chapter FCMC System Messages 24 FCMC-1001 Message , [FCMC-1001], , FFDC, CRITICAL, , System is low on memory and has failed to allocate new memory. Probable Cause Indicates that the switch is low on memory and failed to allocate new memory for an - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 210
24 FCMC-1001 152 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 211
on . Probable Cause Indicates that a Fibre Channel Protocol (FCP) switch probed devices on a control field. Recommended This can happen only if the firmware on the device controller support private loop devices. Refer to the switch vendor for a list of other port types that support - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 212
25 FCPD-1003 154 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 213
allocate new memory for a Fibre Channel driver instance. The function can only be " fc_create". This function creates a Fibre Channel driver instance. The failed is set to ON. Probable Cause Indicates a device which does not support authentication has tried to log in to the switch when the device - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 214
26 FCPH-1002 156 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 215
Chapter FCR System Messages 27 FCR-1001 Message , [FCR-1001], ,, INFO, , FC router proxy device in edge created at port . Probable Cause Indicates that a proxy device in the edge fabric has been imported at the specified port. Recommended - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 216
27 FCR-1005 Recommended Action Verify that the devices were intended to be taken offline. If not, verify that the devices are functioning properly. Verify that all small form-factor pluggables (SFPs) are seated correctly. Check for faulty cables, deteriorated SFPs, or dirty connections. Replace - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 217
27 FCR-1009 Probable Cause Indicates that a logical storage area network (LSAN) zone was created at the specified port in the edge fabric. Recommended No action is required. Action Severity INFO FCR-1009 Message , [FCR-1009], ,, INFO, , FC router LSAN - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 218
1012], ,, INFO, , FC Router fabric build completed on port . Probable Cause Indicates that the fibre channel router has completed a fabric build at the specified port. Recommended No action is required. Action Severity INFO FCR-1013 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 219
device port resources. Use the fcrProxyDevShow command to view how many proxy devices are created in the fabric with the port resource problem. LSAN zones are removed using standard zoning commands such as zoneShow, zoneRemove, zoneDelete, cfgDelete, and cfgDisable in the edge fabric. Proxy devices - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 220
27 FCR-1021 3. Use Zoning commands on the edge fabrics, to reduce the LSAN zone entries on the edge fabrics. 4. Run portEnable on each EX_Port, one at a time, to reenable the EX_Ports, and verify that this error is not reported again. Severity WARNING FCR-1021 Message , [FCR-1021], < - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 221
27 FCR-1024 FCR-1024 Message , [FCR-1024], ,, WARNING, , Local LSAN zone device entries for edge LSAN exhausted. Probable Cause Indicates that the number of devices in a logical storage area network (LSAN) defined in the edge fabric exceeds - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 222
27 FCR-1028 Probable Cause Indicates that the port world wide name (WWN) pool has rolled over in the specified slot, and WWN entries detected to not be in use are reused as needed. Recommended Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 223
27 FCR-1030 FCR-1030 Message , [FCR-1030], ,, INFO, , Physical device came online at fabric . Probable Cause Indicates that the physical device world wide name (WWN) came online in the specified fabric. Recommended No action is - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 224
27 FCR-1034 FCR-1034 Message , [FCR-1034], ,, INFO, , LSAN zone added in backbone fabric. Probable Cause Indicates that a new logical storage area network (LSAN) zone was added to the backbone fabric. Recommended No action is required. Action Severity - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 225
27 FCR-1038 FCR-1038 Message , [FCR-1038], ,, WARNING, , Total zone entries exceeded local fabric limits by entries, in zone: , zone limit: . Probable Cause Indicates that the number of cfg/zone/alias entries created - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 226
Execute the portEnable command. If the problem persists try rebooting the switch. the supportShow command, and contact your switch service provider. Severity ERROR FCR-1049 Message not supported. Indicates an incoming exchange link protocol (ELP) command was issued and it is not supported. 168 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 227
to enable and disable the port. If the problem persists contact your switch service provider. Severity ERROR FCR-1053 Message , ID does not support backbone to edge imports. Probable Cause Indicates that a switch that does not support backbone-to-edge routing was detected - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 228
Recommended No action is required if backbone-to-edge routing is not needed. Otherwise replace the switch with Action one that supports backbone to edge routing. Severity INFO FCR-1057 Message , [FCR-1057], ,, ERROR, , EX_Port() incompatible - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 229
Virtual-channel flow control mode. This is a proprietary protocol. R_RDY mode: Receiver-ready flow control mode. This is the Fibre Channel standard protocol, that uses R_RDY primitive for flow control port number> disabled, system only supports EX/VEX_ports. Fabric OS Message Reference - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 230
27 FCR-1063 Probable Cause Indicates that the maximum number of supported EX_ports or VEX_ports was exceeded. To enable the specified port, disable any other operational port then re-enable the port. Recommended No action is required. - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 231
If the fabric split, then merge the fabrics and manually re-enable the port. If there is another fabric fabric exceeds the maximum number supported by the Fibre Channel. The limit includes both active to 2 (disabled). Note that the FC Routing service is disabled by the factory. Recommended No action - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 232
with the fcrState set to 1 (enabled). Note that the FC Routing service is disabled by the factory. Recommended No action is required. Action Severity Indicates that the FC Routing configuration is set to default by user. This removes all prior FC Routing configurations. Recommended No action - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 233
Action Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find the lowest supported LSAN zone limits. Please make sure CP supports only LSAN Zones. Probable Cause Indicates that the remote control processor (CP) has older firmware, which only supports a - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 234
, disable any other operational front domain and then re-enable the port. Recommended Make sure to remain within the maximum of supported front domains. Action Severity ERROR FCR-1077 Message , [FCR-1077], ,, WARNING, , Port rejected fabric - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 235
, a switch in the fabric has not responded to the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected pause message. Recommended Action Severity WARNING FCR-1081 Message , [FCR - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 236
prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to this does not support FCR based matrix. Probable Cause Indicates that the remote control processor (CP) has older firmware, which does not support FCRbased matrix while - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 237
, [FCR-1088], ,, INFO, , LSAN tag added. Probable Cause Indicates that the user has added a LSAN tag. Recommended No action is required. Action Severity INFO FCR-1089 Message , [FCR-1089], ,, INFO - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 238
27 FCR-1089 180 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 239
that the FICON Channel is directly connected to. HP - Host Port Control Units and all Devices on those control Units from a all LPARs on that FICON Channel. FICN-1003 Message , [FICN-1003], ,, WARNING, , FICON Tape Emulation License Key is not installed - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 240
or Disabled>. Probable Cause Indicates the configuration was changed manually. Recommended No action is required. Action Severity INFO FICN FICON Emulation states>. Probable Cause Indicates a Selective Reset from the channel was received as either a normal part of path recovery or starting - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 241
Data rcvd:Path= LastCmds=0x Sense Data:Bytes0-0xB=0x - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 242
Cause Indicates a Device Level Exception frame received from the FICON DASD Control Unit. Recommended If there was a job or IO failure associated with this event, please contact your vendor's customer Action support for assistance. Severity ERROR FICN-1013 Message , [FICN-1013 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 243
's customer support for assistance. Action Severity ERROR FICN-1016 Message , [FICN-1016], ,, INFO, , DevIng:Received Logical Path Removed response:Path=. Probable Cause Indicates the FICON Control Unit sent an LPR frame to the FICON channel - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 244
emulation status control flags for the device>. Probable Cause Indicates the FICON channel issued a Cancel sequence for a device in emulation. Recommended If there was an unexpected job failure associated with this event, contact your vendor's customer Action support for assistance. Severity - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 245
channel issued a Selective Reset for a device that was active in emulation. Recommended If there was an unexpected job failure associated with this event, contact your vendor's customer Action support :Auto Sense Data received on Path= Bytes0-0xB=0x - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 246
an active emulation device received a cancel operation from the FICON channel. Recommended If there was an unexpected job failure or IO Error associated with this event, contact your vendor's Action customer support for assistance. Severity ERROR FICN-1029 Message Probable Cause - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 247
's Action customer support for assistance. Severity ERROR FICN-1031 Message , [FICN-1031], ,, WARNING, , HostDiskIng:FICON System Reset received on Path=. Probable Cause Indicates the FICON channel sent a System Reset to the disk control unit - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 248
indicates that the channel side noted corruption from the device/CU side processing. Recommended Contact your vendor's customer support for assistance. Cause Indicates a locally connected FICON channel issued a System Reset to the specified FICON Control Unit. Recommended No action is required - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 249
FICON channel sent a frame that could not be associated with a FICON Control Unit. Recommended Contact your vendor's customer support for Sense Data Rcvd:Path= LastCmds=0x SenseData:Bytes0-0xB=0x - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 250
Last 4 status values sent to the channel from this device>. Probable Cause Indicates an LRJ received from a device indicates that the CU has lost the logical path to the LPAR. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 251
Cause Indicates a purge path was received from the locally connected FICON channel. This is performed during the path recovery. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity WARNING FICN-1046 Message , [FICN-1046 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 252
the TIR data from the remotely connected channel or control unit>. Probable Cause Indicates a TIR received from a far side FICON end point indicates that it no longer has an established path to its peer. Recommended This is an unexpected event; contact your vendor's customer support for assistance - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 253
to break an XRC session with the extended DASD device. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity INFO FICN-1053 Message , [FICN-1053], ,, INFO, , XRC Withdraw From Session: SessID - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 254
system-name>, Error return from frame generation processing for a FICON control unit: Path=. Probable Cause Indicates an internal resource and sent to a Control Unit. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 255
This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1060 Message , Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1062 Message , [ - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 256
for an exchange. Recommended If there were associated IO errors at the same time as this event, contact your vendor's customer Action support for assistance. Severity INFO FICN-1065 Message , [FICN-1065], ,, INFO, , Egress Abort:Oxid=0x - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 257
internal resource limit has been encountered such that additional control block memory could not be allocated. Recommended This is use Action or there is an internal memory leak, contact your vendor's customer support for assistance. Severity WARNING FICN-1067 Message , [FICN-1067], < - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 258
IO error messages with this event, please contact your vendor's customer support for assistance. Severity INFO FICN-1071 Message , [FICN-1071], :status=0x:flags=0x - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 259
number of emulated read megabytes processed while this tape was loaded>. Indicates a Rewind and Unload IO has been processed from a locally connected LPAR and Read Channel Program pipelining was performed on the currently loaded tape. Fabric OS Message Reference 201 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 260
DevTapeEgr:Unloaded:Path=:states=0x:cmds=0x:status=0x:flags=0x. Probable Cause Indicates a Rewind and Unload IO has - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 261
reset event. Probable Cause Indicates an LRJ from a FICON channel indicates that the channel does not have a path established to the CU. Recommended This is normally an unexpected event, contact your vendor's customer support for assistance. Action Severity WARNING FICN-1082 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 262
DRAM2 was detected and access to its address range is prohibited. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1085 Message , [FICN-1085], ,, INFO, , FICON FCIP Tunnel is Up - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 263
the haFailover command. If the problem persists, or if this is a nonbladed switch, download a new firmware version using the firmwareDownload command. License Not Installed: (). Probable Cause Indicates that the fibre connectivity control unit port (FICON-CUP) license is not installed on the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 264
the Fabric OS Administrator's Guide for information on core PID mode and the Fabric OS Command Reference Manual for information on these commands a module within the fibre connectivity control unit port (FICON-CUP) daemon failed. Recommended Download a new firmware version using the firmwareDownload - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 265
FICON channel corresponding low. This might be a transient problem. Recommended Action If the message the supportSave command and contact your switch service provider. Severity WARNING FICU-1008 Message the specified ports were disabled when Fibre Connectivity (FICON) Management Server mode - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 266
-number>,, WARNING, , FMS Mode enable failed due to address conflict with port . Probable Cause Indicates that the Fibre Connectivity (FICON) Management Server mode (fmsMode) was not enabled because the specified port which has an address conflict with the CUP management - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 267
Chapter FKLB System Messages 30 FKLB-1001 Message , [FKLB-1001], ,, WARNING, , exchange overlapped, pid= Probable Cause Indicates that the FC kernel driver has timed out the exchange while the application is still active. When the FC kernel - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 268
30 FKLB-1001 210 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 269
number>, FFDC, ERROR, , Excessive LSU length = Probable Cause Indicates that the LSU size exceeds what the system can support. Recommended Reduce the number of switches in the fabric or reduce the number of redundant ISLs between two Action switches. Severity ERROR FLOD - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 270
31 FLOD-1006 Probable Cause Indicates that the received LSR contained an invalid domain number. Recommended No action is required; the LSR is discarded. Action Severity WARNING FLOD-1006 Message , [FLOD-1006], ,, WARNING, , Transmitting invalid domain ID: - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 271
Chapter FSPF System Messages 32 FSPF-1001 Message , [FSPF-1001], ,, ERROR, , Input Port out of range Probable Cause Indicates that the specified input port number is out of range; it does not exist on the switch. Recommended No action is - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 272
input port. Recommended Action Update the FSPF version by running the firmwareDownload command to update the firmware to the latest version. All current versions of the Fabric OS support FSPF version 2, which is the correct version. Severity ERROR 214 Fabric OS Message Reference 53-1001157 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 273
has sent too many concurrent high availability (HA) data updates. Recommended Action Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it Cause Indicates that the Fabric OS state synchronization (FSS) service has dropped the update because an application has not set - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 274
memory usage. Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a supportSave command and contact your switch service provider. Severity ERROR FSS-1005 Message FSS message available Probable Cause Indicates that data is not available on the Fabric OS state - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 275
control processor (CP) and standby CP is not healthy. The error occurs when the standby CP does not respond to a request from the active CP within five seconds. This usually indicates a problem haSyncStart command. If the problem persists, contact your switch service provider. Severity CRITICAL FSS - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 276
33 FSS-1011 FSS-1011 Message , [FSS-1011], ,, INFO, , FSS Info: . Probable Cause Indicates that an error has occurred. Recommended No action is required. Action Severity INFO 218 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 277
availability (HA) state for the active control processor (CP) is out of synchronization with logged as a result of a user-initiated action (such as running problem persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 278
Cause Indicates that the active control processor (CP) and the standby CP in a dual CP system are running firmware that are incompatible with each other. If the active CP fails, the failover will be disruptive. In a switch system, this message is logged when a firmware upgrade/downgrade was invoked - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 279
of the end-user installation. To prevent recurring messages, disable the changed alarm for this threshold. If you receive a temperature-related message, check for an accompanying fan-related message and check fan performance. If all fans are functioning normally, check the climate control in your - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 280
user installation. If you receive a temperature-related message, check for an accompanying fan-related message and check fan performance. If all fans are functioning normally, check the climate control low boundary. Fan problems typically contribute to temperature problems. Recommended Consistently - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 281
correctly in the chassis. Run the psShow command to view the status of the power supply. If the power supply continues to be a problem, replace the faulty power supply. Severity INFO FW-1010 Message Probable Cause , [FW-1010], ,, WARNING, , , is - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 282
that you have installed the power supply correctly and that it is correctly seated in the Action chassis. If the problem persists, replace the message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1033 Message , [FW-1033], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 283
low boundary. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity WARNING FW-1035 Message , [FW-1035], ,, WARNING, , , is above high boundary(High= - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 284
threshold, the SFP is deteriorating. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO 226 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 285
35 FW-1041 FW-1041 Message , [FW-1041], ,, INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the transmit power value of the small form-factor pluggable (SFP) has - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 286
is deteriorating. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1045 Message , [FW-1045], ,, INFO, , , value has changed(High= - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 287
range. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1049 Message , [FW-1049], ,, INFO, , , value has changed(High=, Low - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 288
range. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1113 Message , [FW-1113], ,, INFO, , , value has changed(High=, Low - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 289
by transient errors. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. Check both ends of the physical connection and verify that the SFP functions properly. Severity INFO FW-1116 Message , [FW - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 290
fabric reconfiguration might be a transient error and might not require troubleshooting. Severity INFO FW-1118 Message , [FW-1118], < message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1119 Message , [FW-1119], < - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 291
the fabric. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1121 Message , [FW-1121], ,, INFO, , , value has changed(High=, Low - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 292
the switch. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1124 Message , [FW-1124], ,, INFO, , , is between high and low boundaries(High - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 293
segmentation. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1128 Message Probable Cause , [FW-1128], ,, INFO, , , is between high and low - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 294
segmentation. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1129 Message , [FW-1129], ,, INFO, , , value has changed(High=, Low - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 295
FW-1132 Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1132 Message , [FW-1132], ,, INFO, , , is between high and low boundaries(High= - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 296
or FLOGI. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1137 Message , [FW-1137], ,, INFO, , , value has changed(High=, Low - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 297
to the particular policy of the Action end-user installation. Severity INFO FW-1140 Message , [ problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 298
errors and, if applicable, troubleshoot them. A low number of link loss errors means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1162 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 299
troubleshoot them. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation experience synchronization loss errors, troubleshoot your host bus adaptor (HBA) and contact your switch service provider. Severity INFO FW- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 300
errors, troubleshoot your host bus adaptor (HBA) and contact your switch service provider. to the particular policy of the Action end-user installation. Severity INFO FW-1168 Message , Loss of signal generally indicates a physical problem. Recommended Check both ends of your - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 301
Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. Frequent loss of signal generally indicates a physical problem. Check both ends of your cable connection. Verify that the cable and small form-factor pluggables (SFPs) are - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 302
occur due to software glitches. Persistent protocol errors occur due to hardware problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO 244 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 303
a hardware problem with an small form-factor pluggable (SFP) or cable. A low number of invalid words means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 304
range. Invalid words usually indicate a hardware problem with an small form-factor pluggable (SFP) or cable. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1180 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 305
has changed. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1185 Message , [FW-1185], ,, INFO, , , , is below low boundary(High - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 306
high boundary. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1187 Message , [FW-1187], ,, INFO, , , , is between high and low - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 307
35 FW-1190 Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1190 Message , [FW-1190], ,, INFO, , , , is above high boundary(High=< - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 308
trunk port. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity WARNING FW-1195 Message , [FW-1195], ,, INFO, , , , is between high and low - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 309
this message as is appropriate to the particular policy of the end-user installation. A low Action number of link resets means that the switch is errors that indicate no frame activity at all. Both physical and hardware problems can cause link resets to increase. Recommended Check both ends of your - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 310
problems can cause link resets to increase. Recommended Respond to this message as is appropriate to the particular policy of the end-user installation frame. Invalid CRC messages occur when the number of CRC errors in Fibre Channel frames for specific source ID (S_ID) and destination ID (D_ID) - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 311
problem in this area. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation . Invalid CRC messages occur when the number of CRC errors in Fibre Channel frames for specific source ID (S_ID) and destination ID (D_ID) - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 312
boundary. Invalid CRC messages occur when the number of CRC errors in Fibre Channel frames for specific source ID (S_ID) and destination ID (D_ID) pairs this message as is appropriate to the particular policy of the end-user installation. A low number of CRC errors means that the fabric is - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 313
FW-1244 Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1244 Message , [FW-1244], ,, INFO, , , value has changed(High=, Low= - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 314
D_ID pair. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1248 Message , [FW-1248], ,, INFO, , , value has changed(High=, Low - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 315
received small computer system interface (SCSI) Read, SCSI Write, SCSI Read and Write, SCSI Traffic, or IP commands in a frame. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1273 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 316
a small computer system interface (SCSI) Read, SCSI Write, SCSI Read and Write, SCSI Traffic, or IP commands in a frame. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1275 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 317
Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity WARNING FW-1299 Message , [FW-1299], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 318
. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity WARNING 260 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 319
Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity INFO FW-1305 Message , [FW-1305], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 320
Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity WARNING FW-1307 Message , [FW-1307], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 321
Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity WARNING FW-1311 Message , [FW-1311], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 322
. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity WARNING 264 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 323
the request. Responses to security class messages depend on user policies. Consult your security administrator for response strategies and boundary. SES violations indicate that a small computer system interface (SCSI) Enclosure Services (SES) request has been received from an unauthorized world - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 324
. SES violations indicate that a small computer system interface (SCSI) Enclosure Services (SES) request has been received from an unauthorized world the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 325
the errShow command to determine the WWN of the device that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity WARNING FW-1323 Message , [FW-1323], ,, INFO - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 326
Run the errShow command to determine the WWN of the device that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity INFO FW-1325 Message , [FW-1325], ,, INFO - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 327
Run the errShow command to determine the WWN of the device that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity INFO FW-1329 Message , [FW-1329], ,, INFO - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 328
sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and Value> . Probable Cause Indicates that the number of switch connection control policy (SCC) violations has changed. SCC violations indicate that an - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 329
> . Probable Cause Indicates that the number of switch connection control policy (SCC) violations has risen above the high boundary. SCC sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 330
Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity INFO FW-1337 Message , [FW-1337], ,, INFO - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 331
Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity WARNING FW-1339 Message , [FW-1339], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 332
the packet. This counter keeps track of packets rejected due to invalid timestamps. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies and policies. Severity INFO 274 Fabric OS Message Reference 53-1001157 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 333
packet. This counter keeps track of packets rejected due to invalid timestamps. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies and policies. Severity WARNING FW-1347 Message Probable Cause - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 334
. This counter keeps track of the number of packets received with invalid signatures. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies and policies. Severity INFO FW-1349 Message , [FW-1349 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 335
fabric configuration server (FCS). Before a new primary FCS switch sends any configuration data to any switch in the fabric, it first sends its certificate to all . Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 336
fabric configuration server (FCS). Before a new primary FCS switch sends any configuration data to any switch in the fabric, it first sends its certificate to all the . Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 337
occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly, or failures. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies and - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 338
occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or transmission IDs. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 339
IDs. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies number of time service (TS) out-of-sync violations has changed. Recommended Responses to security-class messages depend on user policies. Consult - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 340
boundary. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies is . Probable Cause Indicates that the number of time service (TS) out-of-sync violations has changed from a value outside of the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 341
this counter and resets the WWN of the primary FCS to all zeroes. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies and policies. Severity WARNING FW-1371 Message , [FW-1371], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 342
that the version stamp and fabric configuration server (FCS) policy matches exactly. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies and policies. Severity INFO FW-1373 Message , [FW-1373 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 343
time someone issues one of these commands on a switch where it is not allowed. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies and policies. Severity INFO Fabric OS Message Reference 285 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 344
someone issues one of these commands on a switch where it is not allowed. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies and policies. Severity WARNING FW-1379 Message Probable Cause , [FW - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 345
operation of the switch. Excessive permanent increases can lead to future problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1401 Message , [FW-1401], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 346
operation of the switch. Excessive permanent increases can lead to future problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1424 Message , [FW-1424], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 347
35 FW-1427 Recommended Replace the faulty or missing power supply. Action Severity WARNING FW-1427 Message , [FW-1427], ,, WARNING, , Switch status change contributing factor Power supply: bad. Probable Cause Indicates that the switch - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 348
35 FW-1430 FW-1430 Message , [FW-1430], ,, WARNING, , Switch status change contributing factor . Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty temperature sensors is greater - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 349
are non-redundant. If you power cycle a Brocade 24000 chassis in dual-domain configuration, and then reset the micro-switch of the active CP verify that both CPs have compatible firmware levels. Run the firmwareDownload command to install the same level of firmware to both CPs. Replace any faulty - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 350
35 FW-1437 Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of marginal ports is greater than or equal to the policy set using the switchStatusPolicySet command. A port is faulty when the port value for Link Loss, Synchronization Loss, - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 351
35 FW-1440 Severity WARNING FW-1440 Message , [FW-1440], ,, INFO, , state has changed to . Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to "absent". Recommended No action is - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 352
supplies for full (2X) redundancy, but the user has previously overridden the Switch Status Policy values pertaining to number of power supplies. So those values will not be automatically changed. The default values with no AP blades are: 3 out of service indicates switch status is DOWN, 0 indicates - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 353
faulty cable. Protocol errors indicates CRC sum disparity. Occasionally, these errors occur due to software glitches. Persistent errors occur due to hardware problems. Recommended Check for concurrent loss of synchronization errors. Check the SFP and the cable. Then enable the Action port using the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 354
35 FW-1510 296 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 355
="NONE" Severity> Probable Cause Indicates that a standby control processor (CP) device error is reported by the the card and reseating it. If the problem persists, replace the standby CP. Severity CRITICAL system has been rebooted either because of a user action or an error. The switch reboot - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 356
INFO HAM-1006 Message Probable Cause , [HAM-1006], ,, CRITICAL, ,EMAC controller for Active CP is BAD. Indicates that the local EMAC controller on the active control processor (CP) is BAD as determined by the diagnostic test run by the HAM module. 298 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 357
. Recommended No action is required. Action Severity CRITICAL HAM-1009 Message , [HAM-1009], ,, CRITICAL, ,Need to MANUALLY REBOOT the system for recovery - auto-reboot is disabled. Probable Cause Recovery by reboot is disabled, the system needs to be - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 358
36 HAM-1009 300 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 359
then run the supportSave command and contact your switch service provider. Severity CRITICAL HAMK-1002 Message , [HAMK-1002], ,, INFO, , Heartbeat down. Probable Cause Indicates that the active control processor (CP) blade determined that the standby CP - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 360
Message ,[HAMK-1004], ,, INFO, , Resetting standby CP (double reset may occur). Probable Cause Indicates that the standby control processor (CP) is being reset due to a loss of heartbeat. This message is typically seen when the standby CP has been rebooted - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 361
supply status. Try to reseat the faulty fan field-replaceable unit (FRU) and power supply FRU to verify that they are seated properly. If the problem persists, replace the fan FRU or the power supply FRU as necessary. Severity ERROR Fabric OS Message Reference 303 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 362
status. Try to reseat the faulty fan field-replaceable unit (FRU) and power supply FRU to verify that they are seated properly. If the problem persists, replace the fan FRU or the power supply FRU as necessary. Severity ERROR HIL-1105 Message , [HIL-1105], ,, ERROR - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 363
Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. Fabric OS - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 364
Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. If the fan - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 365
speed (in RPMs) has fallen below the minimum threshold. This problem can quickly cause the switch to overheat. This message is specific is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Use the fanShow command - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 366
a fan field-replaceable unit (FRU) has failed or has been removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Replace the affected fan FRU immediately. Action Severity WARNING HIL-1302 Message , [HIL-1302 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 367
38 HIL-1305 Severity ERROR HIL-1305 Message , [HIL-1305], ,, ERROR, , One or two fans failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fan field-replaceable units (FRUs) have failed. This message is often preceded by a - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 368
switch because the fan is not field-replaceable. Severity INFO HIL-1401 Message , [HIL-1401], ,, WARNING, , One fan FRU missing. Install fan FRU immediately. 310 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 369
FRUs immediately. Action Severity WARNING HIL-1404 Message , [HIL-1404], ,, WARNING, , fan FRUs missing. Install fan FRUs immediately. Probable Cause Indicates that one or more fan field-replaceable units (FRUs) have been removed. Recommended - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 370
that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. If the message persists, replace the faulty blade. Severity CRITICAL HIL-1504 Message Probable - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 371
operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Severity CRITICAL HIL the switch, the system shuts down automatically. To help prevent future problems, make sure that all the fans are working properly. Make sure - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 372
operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Severity CRITICAL HIL the system can continue operation. Recommended Action To help prevent future problems, make sure that all the fans are working properly. Make sure - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 373
FFDC, CRITICAL, , fans out of service. System is shutting down immediately. Probable Cause Indicates that the total switch, the system shuts down automatically. To help prevent Action future problems, make sure that all the fans are working properly. Severity CRITICAL - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 374
cord is connected to the unit with a valid power source and then switch on the Action unit. If the problem persists, try reseating the unit. If the problem still persists replace the FRU. Severity WARNING HIL-1650 Message , [HIL-1650], , ERROR, , - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 375
Chapter HLO System Messages 39 HLO-1001 Message , [HLO-1001], , FFDC, ERROR, , Incompatible Inactivity timeout from port , correct value . Probable Cause Indicates that the HLO message was incompatible with the value - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 376
39 HLO-1003 The switch has received an invalid HLO because either the domain or port number in the HLO message has an invalid value. This error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended The HLO message of the remote switch must be - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 377
Probable Cause Indicates there was a problem reading an essential file containing configuration information from the file system. Recommended Action Run the firmwareDownload command to reinstall the firmware to your switch. If the message persists, run supportFtp (as - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 378
40 HMON-1001 320 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 379
, take appropriate action as defined by your enterprise security policy. Severity INFO HTTP-1003 Message , [HTTP-1003], , AUDIT, INFO, , Zoning transaction initiated by User: , Role: could not be completed successfully - - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 380
41 HTTP-1003 322 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 381
Chapter IBD System Messages 42 IBD-1001 Message , [FKLB-1001], ,, ERROR, , Slot , Port GE: Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the specified port has crashed unexpectedly and - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 382
42 IBD-1001 324 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 383
target name length exceeds the character limit [] Probable Cause Indicates that the target name length exceeds the supported limit. Recommended Redo the discovery to get the latest target list, and try again. Action Severity WARNING IBPD-1003 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 384
43 IBPD-1003 326 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 385
of a module within the ICPD failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action , , iSNS Client service is detected on multiple switches in fabric. Indicates the iSNS Client service is enabled on multiple switches in - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 386
this command. Severity WARNING ICPD-1006 Message , [ICPD-1006], ,, INFO, , iSCSI service is on the switch. Probable Cause Indicates the iSCSI service is enabled or disabled on the switch. Recommended No action is required. Action Severity INFO - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 387
Recommended No action is required. Action Severity INFO 44 ICPD-1008 Fabric OS Message Reference 329 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 388
44 ICPD-1008 330 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 389
- HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 390
45 IPAD-1001 332 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 391
Installed () Probable Cause Indicates the FCIP license is not installed on the switch. Recommended Run the licenseShow command to check the installed a new firmware version using be a transient problem. Recommended Action If and contact your switch service provider. Severity WARNING - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 392
46 IPS-1005 Probable Cause Indicates that configured Port Mode is different from the intended use. Recommended Change the port configuration (by deleting configured FCIP tunnels or iSCSI sessions) to return the Action port mode to neutral before attempting to configure the port for a different mode - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 393
Chapter ISCS System Messages 47 ISCS-1000 Message , [ISCS-1000], ,, ERROR, , Slot Port GE crashed unexpectedly. Probable Cause Indicates the specified port has crashed. Recommended No action is required; the port will restart - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 394
47 ISCS-1000 336 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 395
number>/ge). Probable Cause Indicates that the user has issued the isnscCfg command. Recommended No action is required. disabled. Probable Cause Indicates the IP address of the internet storage name service (iSNS) server is zero. Hence peering is disabled. Recommended If you - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 396
slot/port /ge. Probable Cause Indicates a user has requested a re-register with the specified external internet storage name service (iSNS) server. Recommended No action is required. Action Severity INFO ISNS-1006 Message , [ISNS - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 397
started because no virtual targets found. Probable Cause Indicates that no virtual targets were slot/port. Refer to the appropriate hardware reference manual for valid slot and Action port ranges. Severity , or disable the iSNS client Action service. Severity INFO ISNS-1013 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 398
server on management port. Probable Cause Indicates that peering has started with the specified external internet storage name service (iSNS) on the management port. Recommended No action is required. Action Severity INFO 340 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 399
Chapter KAC System Messages 49 KAC-1002 Message , [KAC-1002], ,, ERROR, , KAC() communication Error: Error connecting to . Probable Cause Indicates that the key archival client is unable to communicate with the primary - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 400
49 KAC-1008 Probable Cause Indicates that the key archival client is unable to put to the primary or backup key vault. Recommended Determine whether the configured key value is operational, and if it is not, change the switch key Action vault settings. Severity ERROR KAC-1008 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 401
along with any core file information, and contact your switch service Action provider. Severity WARNING KSWD-1002 Message , [KSWD . The switch will reboot (on single-CP switches) or fail over (on dual-CP switches). The warning message will be one of the following: • - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 402
, run supportFtp to send all core files to a secure server location. Copy the warning message along with any core file information, and contact your switch service provider. Severity WARNING 344 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 403
Chapter KTRC System Messages 51 KTRC-1001 Message , [KTRC-1001], ,, WARNING, , Dump memory size exceeds dump file size Probable Cause Indicates the dump memory size has exceeded the dump file size. Recommended No action is required. Action Severity - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 404
51 KTRC-1005 Recommended No action is required. Action Severity ERROR KTRC-1005 Message , [KTRC-1005], ,, ERROR, , Trace initialization failed. . . Probable Cause Indicates that a trace was unable to - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 405
Fabric Manager service is disabled. Note that the Logical Fabric Manager service is enabled by the factory setting and it is not user configurable. all prior Logical Fabric Manager configurations. This operation is not supported, currently. Recommended No action is required. Action Severity INFO - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 406
for some internal logging purpose. Recommended Send the ffdc log to the support. Action Severity CRITICAL LFM-1005 Message , [LFM-1005], < -number>,, WARNING, , The switch with domain with firmware version has joined the FID fabric and may not be - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 407
persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING LOG-1002 Message , [LOG-1002], , FFDC, WARNING, , A log message was dropped Probable - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 408
53 LOG-1003 LOG-1003 Message , [LOG-1003], ,, INFO, , The log has been cleared. Probable Cause Indicates the persistent error log has been cleared. Recommended No action is required. Action Severity INFO 350 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 409
is the same as the valid domain ID, whose range is from 1 through 239. The switch will discard the record because it is not supported. Recommended No action is required. Action Severity ERROR LSDB-1002 Message , [LSDB-1002], ,, INFO, , Local Link State - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 410
54 LSDB-1004 Severity CRITICAL LSDB-1004 Message , [LSDB-1004], ,, WARNING, , No Link State Record for domain Probable Cause Indicates there is no link state record for the specified local domain. Recommended No action is required. The - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 411
automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR MFIC-1002 Message , [MFIC-1002], used only in the following SB ELS frames: Request Node Identification Data (RNID) and Registered Link Incident Record (RLIR). The use of - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 412
55 MFIC-1003 Recommended Action IDID mode is a fabric-wide mode; make sure that any switches added to the fabric are configured with the same IDID mode as the fabric. If you are enabling or disabling IDID mode, this message is for information purposes only, and no action is required. IDID mode can - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 413
Chapter MPTH System Messages 56 MPTH-1001 Message , [MPTH-1001], , FFDC, ERROR, , Null parent, lsId = Probable Cause Indicates a null parent was reported. MPATH uses a tree structure in which the parent is used to connect to the root of the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 414
56 MPTH-1003 356 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 415
Chapter MQ System Messages 57 MQ-1004 Message , [MQ-1004], ,, ERROR, , mqRead, queue = , queue ID = , type = Probable Cause Indicates an unexpected message has been received in the specified message queue. The queue - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 416
57 MQ-1004 358 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 417
> The switch did not respond to a request for a GCAP (MS Get Capabilities) command. • The GCAP (MS Get Capabilities) is supported but the flag for MS platform service is not set. • The GCAP (MS Get Capabilities) is not - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 418
by> Run the firmwareDownload command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS v2.6, v3.1 and greater, transfers; then run the supportSave command and contact your switch service provider. Severity INFO MS-1004 Message , [MS - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 419
a reject IU; the MS received neither response, which violates the Fibre Channel Generic Services (FS-GS) specification. Recommended Check the integrity of the FC Indicates the management server (MS) received an information unit (IU) data of unexpected size. The IU payload and the IU size might be - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 420
Action Persistent RLIR incidents are likely the result of SAN hardware problems such as bad cables or small form-factor pluggables (SFPs). FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR MS-1022 Message , [MS-1022], < - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 421
Cause Indicates Management Server Topology Discovery Service is being enabled or disabled. Recommended No action is required. Action Severity INFO MS-1024 Message , [MS-1024], ,, INFO, , Management Server Access Control List is Updated. Probable Cause - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 422
58 MS-1024 364 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 423
- Down • 1 - Init • 2 - Database Exchange • 3 - Database Acknowledge Wait • 4 - Database Wait • 5 - Full If this error occurs repeatedly, then there is a problem in the protocol implementation between two switches. Recommended Action Run the nbrStateShow command to check the neighbor state of the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 424
are as follows: • 0 - Down • 1 - Init • 2 - Database Exchange • 3 - Database Acknowledge Wait • 4 - Database Wait • 5 - Full Recommended No action is required. The Fabric OS automatically recovers from this problem. Action Severity WARNING 366 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 425
remote switch can handle. Recommended Action Run the firmwareDownload command to upgrade the remote switch with firmware v4.3 or higher, as appropriate for the switch type, so that it can support GMI to handle frame fragmentation and reassembly. You can also reduce the number of devices connected - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 426
>, can't sync. Probable Cause Indicates the name server on the standby CP has lower supported capability than the active CP because of different firmware versions running on the active and standby CPs. This means that the active and standby CPs are out of sync. Any execution of the haFailover - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 427
file during the installation. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 428
, , FSS register failed. Probable Cause Indicates the parity data manager (PDM) failed to register with the Fabos synchronization service (FSS). Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 429
parity data manager (PDM) system call to setCfg failed. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 430
could not read data from the specified file. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 431
Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1017 Message , [PDM - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 432
-name>, DNS is configured for IPv6. Probable Cause Indicates the parity data manager (PDM) cannot synchronize with its peer because the domain name service (DNS) is configured for IPv6. IPv6 is not supported by older firmware. Recommended Action Run the firmwareDownload command to reinstall the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 433
61 PDM-1024 Fabric OS Message Reference 375 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 434
61 PDM-1024 376 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 435
Chapter PDTR System Messages 62 PDTR-1001 Message , [PDTR-1001], ,, INFO, , . Probable Cause Indicates information has been written to the panic dump files. The watchdog register codes are as follows: • 0x10000000 bit set means - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 436
62 PDTR-1002 378 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 437
up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL PLAT-1001 Message , [PLAT-1001], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 438
-1003], , FFDC, CRITICAL, , Slot C/BE: ADBUS: misc_intr . Probable Cause Indicates a PCI bus hang was detected. Recommended The FRU must be replaced - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 439
Chapter PMGR System Messages 64 PMGR-1001 Message , [PMGR-1001], , INFO, , Switch was successfully created. Probable Cause Indicates the switch with the specified FID was successfully created. Recommended No action is required. Action Severity - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 440
64 PMGR-1005 Recommended No action is required. Action Severity WARNING PMGR-1005 Message , [PMGR-1005], , INFO, , Ports on slot to switch were moved successfully. Probable Cause Indicates the successful attempt to move the ports to - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 441
64 PMGR-1009 Recommended No action is required. Action Severity WARNING PMGR-1009 Message , [PMGR-1009], , INFO, , The base switch was successfully changed to switch . Probable Cause Indicates the successful change of the base switch. Recommended - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 442
64 PMGR-1010 384 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 443
that exceeded an internally set threshold on the port. This problem is typically related to hardware. Recommended Action Check and replace name>, Slot port does not support configured L_port. Issue portCfgLport to clear configuration. Indicates the specified port - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 444
65 PORT-1005 Recommended Invoke the portCfgLport to clear the L_port configuration. Action Severity WARNING 386 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 445
does not, reboot or power cycle the switch to Action reinitiate the firmware. Severity CRITICAL PS-1001 Message , [PS-1001], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 446
ISL port. Recommended No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is Action enabled. ISL monitoring can only Recommended Delete end-to-end monitors on that switch and re-install fabricmode TopTalker monitor. End-to-end Action monitors and fabricmode - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 447
Chapter PSWP System Messages 67 PSWP-1001 Message , [PSWP-1001], ,, INFO, , Areas for port and port are swapped. New area for port - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 448
67 PSWP-1003 390 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 449
limit> MB) was reached. Probable Cause Indicates that the maximum storage size for FFDC data capture is reached. Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING RAS-1004 Message , [RAS-1004], , FFDC, WARNING - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 450
service provider. Action Severity WARNING RAS-1006 Message , [RAS-1006], , INFO, , Support data file () automatically transferred to remote address ' '. Probable Cause Indicates that the support data - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 451
68 RAS-3001 Probable Cause A user has changed the configured classes of the audit feature. Recommended No action is required. Action Severity INFO RAS-3001 Message , [RAS-3001], , - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 452
68 RAS-3004 Recommended No action is required. Action Severity INFO 394 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 453
in Fabric OS v2.6, v3.1 and greater, and v4.1 and greater. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity INFO RCS-1002 Message , [RCS-1002], ,, INFO, , RCS has been enabled. Probable Cause - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 454
. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity ERROR RCS-1005 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 455
1007 Message , [RCS-1007], ,, ERROR, , Zone DB size and propogation overhead exceeds domain 's maximum supported Zone DB size . Retry after reducing the Zone DB size. Probable Cause Indicates a domain cannot handle the zone - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 456
69 RCS-1008 398 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 457
Message , [RKD-1003], ,, CRITICAL, , encountered a FATAL SCSI error and will be suspended.\n.\nCommand: \nLBA: \nNum Blocks: \nError: \nSK - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 458
70 RKD-1003 400 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 459
client IP address has faulty credentials. Recommended Enter the correct user name and password from the Fabric Access API host. Action an SSL certificate is missing. Recommended To enable RPCD in secure mode, install a valid SSL certificate on the switch. Action Severity WARNING RPCD-1003 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 460
RPCd is disabled. Probable Cause Indicates the SSL certificate file has been corrupted. Recommended To enable RPCD in Secure mode, install a valid SSL certificate the switch. Action Severity WARNING RPCD-1005 Message , [RPCD-1005], ,, WARNING, , Missing - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 461
Probable Cause Indicates that the RTWR has exhausted the maximum number of retries sending data to the specified domain. Possible detail values include: • RTWRTransmit: Max retries command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 403 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 462
is reachable. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO 404 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 463
-number>,, ERROR, , string description of command which failed> of GE failed. Please retry the command. Data inst= st= rsn= fn= oid=. Probable Cause The Hardware is not responding - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 464
73 SAS-1001 406 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 465
. Some valid values for daemon name are listed below. For a complete listing, see the Introduction to this manual. • fabricd • asd • evmd • fcpd • webd • msd • nsd • psd • snmpd • command and contact your switch service provider. Severity CRITICAL Fabric OS Message Reference 407 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 466
74 SCN-1001 408 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 467
> Probable Cause Indicates that the reliable commit service (RCS) process failed to complete. RCS is a mechanism for transferring data from one switch to other switches within the action as defined by your enterprise security policy. Severity ERROR Fabric OS Message Reference 409 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 468
defined by your enterprise security policy. Severity data>. Probable Cause Indicates that invalid data user command, retry the statistic command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 469
75 SEC-1007 SEC-1007 Message , [SEC-1007], ,, INFO, , Security violation: Unauthorized host with IP address tries to establish API connection. Probable Cause Indicates a security violation was reported. The IP address of - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 470
not exist, follow the steps for re-creating PKI objects, outlined in the Secure Fabric OS Administrator's Guide. If a certificate does not exist or is invalid, install the certificate by following the field upgrade process. Severity WARNING SEC-1024 Message , [SEC-1024], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 471
75 SEC-1026 SEC-1026 Message , [SEC-1026], ,, ERROR, , Invalid format or character in switch member . Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only when the primary - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 472
by standby. CPs will go out of sync. Probable Cause Indicates the security database size is not supported by the standby control processor (CP). Recommended Reduce the security policy size by deleting entries within a policy or by deleting some policies. Action Severity WARNING SEC-1032 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 473
as a member parameter in the secPolicyAdd command. Only the secPolicyCreate command supports use of the asterisk for adding switches to policies. Recommended Action Run or switch name) to add specific switches to the switch connection control (SCC) policy. Refer to the Fabric OS Command Reference - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 474
75 SEC-1037 SEC-1037 Message , [SEC-1037], ,, ERROR, , Invalid WWN format . Probable Cause Indicates the world wide name (WWN) entered in the policy member list had an invalid format. Recommended Run the command again using the standard WWN - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 475
75 SEC-1042 Severity ERROR SEC-1042 Message , [SEC-1042], ,, ERROR, , Invalid index/area member in portlist (). Out of range ( - ). Probable Cause Indicates the specified index or area member is not - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 476
75 SEC-1046 Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR SEC-1046 Message < - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 477
75 SEC-1051 Severity ERROR SEC-1051 Message , [SEC-1051], ,, ERROR, , Missing brace for port list . Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 478
75 SEC-1054 SEC-1054 Message , [SEC-1054], ,, ERROR, , Invalid FCS list length Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 479
Invalid number of Domains in Domain List. Probable Cause Indicates that either no domains or domains more than the maximum number supported are specified. Recommended Enter the correct number of domains. Action Severity ERROR SEC-1063 Message , [SEC-1063], ,, ERROR - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 480
valid, Action generate the PKI objects and install the certificate by following the field upgrade process supportSave command Action and contact your switch service provider. Severity ERROR SEC-1071 Message , No new security policy data to apply. Probable Cause Indicates that no - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 481
. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1073 Message , [SEC-1073], ,, ERROR, , No FCS policy in list! Probable Cause - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 482
the command when all switches are ready. Severity ERROR SEC-1078 Message , [SEC-1078], ,, ERROR, , No new data to abort. Probable Cause Indicates there are no new changes in the defined security policy database that can be aborted. Recommended Verify - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 483
-1081], ,, ERROR, , Entered a name for a DCC policy ID that was not unique. Probable Cause Indicates the device connection control (DCC) policy name given in the secPolicyCreate command was the same as another DCC policy. Recommended Make sure that the DCC policy name - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 484
75 SEC-1083 Recommended Use proper syntax when creating policies. If the security database is too large, you must delete Action other members within the database before adding new members to a policy. Severity ERROR SEC-1083 Message , [SEC-1083], ,, ERROR, - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 485
sequence-number>,, ERROR, , The security database is larger than the data distribution limit of fabric bytes. Probable Cause Indicates the security database has more data than can be distributed to some of the switches in the fabric. Recommended Reduce - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 486
75 SEC-1090 SEC-1090 Message , [SEC-1090], ,, ERROR, , SCC list contains FCS member. Please remove member from the FCS policy first. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 487
75 SEC-1094 Probable Cause Indicates the new fabric configuration server (FCS) list does not have a common member with the existing FCS list. Recommended Resubmit the command with at least one member of the new FCS list in common with the current Action FCS list. Severity ERROR SEC-1094 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 488
persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR SEC-1098 Message , [SEC-1098], ,, ERROR, , No FCS list. Probable - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 489
>,, ERROR, , Fail to download . Probable Cause Indicates the switch failed to download a installed and retry the operation. If a valid certificate is not installed, install a certificate by following the procedure specified in the Secure Fabric OS Administrator's Guide - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 490
,, ERROR, , Failed to sign message data. Probable Cause Indicates that some public key infrastructure (PKI) objects on re-creating PKI objects outlined in the Secure Fabric OS Administrator's Guide. Severity ERROR SEC-1107 Message , [SEC-1107], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 491
75 SEC-1110 Probable Cause Indicates that a version reset operation failed either because the switch could not get all the required resources to perform the operation or because it failed to send the message to all switches in the fabric. Recommended Action Verify that the security event was - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 492
75 SEC-1113 Recommended Make sure that the new FCS policy is the same as the current FCS policy on the switch. Action Severity ERROR SEC-1113 Message , [SEC-1113], ,, WARNING, , [ license ] going to expire in days. Probable - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 493
data received by the primary fabric configuration server (FCS) switch. This data can be an FCS password, a non-FCS password, SNMP data, or multiple user authentication data set. Recommended Usually this problem is transient. Retry the enterprise security policy. Severity INFO Fabric OS Message Reference - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 494
of range when . Probable Cause Indicates the time on the switch is not synchronized with the primary fabric configuration server (FCS), the data packet is corrupted, or a replay attack is launched on the switch. Recommended Action Verify the security event was planned. If the security event - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 495
, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-1130 Message take appropriate action as defined by your enterprise security policy. Severity INFO SEC-1135 take appropriate action as defined by your enterprise security policy. Severity INFO SEC-1136 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 496
) switch. This message usually indicates that the data package is corrupted, the time stamp on the a replay attack or out-of-sync time service, or the signature verification failed. Signature verification take appropriate action as defined by your enterprise security policy. Severity INFO SEC-1139 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 497
switch. This message usually indicates that the data package is corrupted, the time stamp on replay attack or out-of-sync time service, or the signature verification failed. Signature verification take appropriate action as defined by your enterprise security policy. Severity INFO SEC-1146 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 498
-edge PID. If the device connection control (DCC) polices existed, all index/ supported Probable Cause Indicates that reliable commit service (RCS) is not supported support RCS, obtain the latest firmware version from your switch supplier, and run the firmwareDownload command to upgrade the firmware - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 499
. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO SEC-1158 Message , [SEC-1158], ,, INFO, , Invalid name - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 500
75 SEC-1159 SEC-1159 Message , [SEC-1159], ,, INFO, , Non_Reachable domain . Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 501
, if this switch should become primary FCS. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity ERROR SEC-1168 Message , [SEC-1168], ,, ERROR, , Primary FCS failover is busy. Please - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 502
whether all PKI objects exist. If they do not exist, run the pkiCreate command to create them for the switch. Run the licenseAdd command to install the required license key. Refer to your switch supplier to obtain a license if you do not have one. Severity ERROR SEC-1172 Message Probable Cause - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 503
. Severity ERROR SEC-1175 Message , [SEC-1175], ,, ERROR, , Failed to install zone data. Probable Cause Indicates the zone database could not be installed on the switch. Recommended Verify all switches in the fabric are in time synchronization with the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 504
is complete, retry the operation. Severity ERROR SEC-1180 Message , [SEC-1180], ,, INFO, , Added account with authorization. Probable Cause Indicates the specified new account has been created. Recommended No action is required - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 505
, server ID . Probable Cause Indicates the specified action is applied to the specified Remote Authentication Dial-in User Service (RADIUS) / Lightweight Directory Access Protocol (LDAP) server configuration. The possible actions are ADD, REMOVE, CHANGE, and MOVE Recommended No - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 506
number> of switch . Probable Cause Indicates a device connection control (DCC) security violation was reported. The specified device attempted to login your fabric. Take appropriate action, as defined by your enterprise security policy. Severity INFO SEC-1189 Message , [ - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 507
valid violation message and an unauthorized entity is trying to access your fabric. Take appropriate action, as defined by your enterprise security policy. Severity INFO SEC-1191 Message , [SEC-1191], ,, INFO, , Security violation: Unauthorized host with - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 508
>, This switch does not have all the required PKI objects correctly installed. Probable Cause Indicates there has been a corruption during the distribution accounts admin and user do not exist on the switch when enabling security. Recommended Reset the default admin and user account names on - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 509
1197], ,, INFO, , Changed account . Probable Cause Indicates the specified account has changed. Recommended No access your fabric. Take appropriate action, as defined by your enterprise security policy. Severity INFO SEC-1199 Message , [SEC- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 510
is a valid violation message and an unauthorized entity is trying to access your fabric. Take appropriate action, as defined by your enterprise security policy. Severity INFO SEC-1201 Message , [SEC-1201], ,, INFO, , Security violation: MS device - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 511
err=, key= Probable Cause Indicates and contact your switch service provider. Severity WARNING and contact your switch service provider. Severity ERROR SEC caused the device connection control (DCC) policy update and contact your switch service provider. Severity ERROR SEC - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 512
the Brocade Secure Fabric OS feature. Recommended Run the firmwareDownload command to update the firmware to the latest version for your specific Action switch. Verify the firmware you are installing supports the Brocade Secure Fabric OS feature. Severity INFO 454 Fabric OS Message Reference 53 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 513
switch. If a failure to validate PKI objects occurs, follow the steps for re-creating PKI objects outlined in the Secure Fabric OS Administrator's Guide. If PKI objects are valid, verify that an unauthorized switch is not trying to access the fabric. Severity INFO Fabric OS Message Reference 455 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 514
Indicates that all servers in the remote authentication dial-in user service (RADIUS) configuration have failed to respond to a switch request system-name>, Unable to determine data distribution limit of fabric. Please retry later. Probable Cause Indicates the data distribution limit could not be - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 515
security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-1313 Message , [SEC-1313], ,, INFO, , The passwdcfg parameters were set to - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 516
to the EM module to retrieve the IP address failed. Recommended Reboot the system to fix this error. If the problem persists contact your switch service provider. Action Severity ERROR SEC-1315 Message , [SEC-1315], ,, ERROR, , command - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 517
your enterprise security policy. Severity INFO SEC-1320 Message , [SEC-1320], ,, WARNING, , Non-acl domain tries to join a fabric with strict fabric wide policy Probable Cause Indicates that a domain not supporting an access control list - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 518
fabric is not able to support a device connection control (DCC) policy with more , take appropriate action as defined by your enterprise security policy. Severity INFO SEC-1324 Message code> Probable Cause Indicates the reliable commit service (RCS) transaction failed with the specified reason - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 519
Fabric wide configuration set to . Probable Cause Indicates the specified event has occurred. Recommended Verify was not Action planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-1327 Message , [SEC - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 520
Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1330 Message , [SEC-1330], ,, ERROR, , command failed - - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 521
event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3036 Message , [SEC-3036], , AUDIT, INFO, , Event: ipfilter, Status: failed, Info - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 522
event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3039 Message , [SEC-3039], , AUDIT, INFO, , Event:Securty Violation , Status: failed - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 523
security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3051 Message , [SEC-3051], , AUDIT, INFO, , The license key is - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 524
75 SEC-3051 466 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 525
Cause Indicates the simple network management protocol (SNMP) service could not be started because of the specified Reason. You will not be able to query the switch through SNMP. Recommended Verify the IP address for the Ethernet and Fibre Channel interface is set correctly. If the specified Action - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 526
name>, Incorrect SNMP configuration. Probable Cause Indicates the simple network management protocol (SNMP) configuration is incorrect and the SNMP service will not work correctly. Recommended Change the SNMP configuration back to the default. Action Severity ERROR SNMP-1005 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 527
76 SNMP-1008 Severity INFO SNMP-1008 Message , [SNMP-1008], ,, INFO, , The last device change happened at: . Probable Cause Indicates the last device change time. Recommended Execute the nsshow to view the current device status. Action Severity - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 528
76 SNMP-1008 470 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 529
Chapter SPC System Messages 77 SPC-1001 Message , [SPC-1001], ,, INFO, , , Cryptographic operation enabled. Probable Cause Indicates the cryptographic operation is enabled on an encryption engine. Recommended - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 530
Recommended EE is zeroized. User needs to run initEE Data disable signal status. Recommended No action is required. Action Severity INFO SPC-2004 Message , [SPC-2004], ,, ERROR, , , : FPGA firmware - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 531
SPC-2005 Message , [SPC-2005], ,, INFO, , , : FPGA firmware download success: 0x%x. Probable Cause Indicates the FPGA download was successful. Recommended No action is required. Action Severity INFO - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 532
, , : Tamper event: User zeroization. Probable Cause Indicates the Tamper event triggered due to a user zeroize request. Recommended EE is zeroized. User needs to run initEE and regEE. Action Severity CRITICAL SPC-2010 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 533
77 SPC-3001 SPC-3001 Message , [SPC-3001], ,, ERROR, , , : No input KEK for DEK inject, DEK: , KEK: - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 534
format • 32 - DEK could not be unwrapped • 33 - FGPA error upon inject • 73 - Invalid KEK format Recommended Contact technical support. Action Severity ERROR SPC-3006 Message , [SPC-3006], ,, ERROR, , , - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 535
status code 14, complete primary KEK generation; otherwise, contact technical support. Action Severity ERROR SPC-3008 Message , [SPC-3008 certificate mismatch, certificate: . Probable Cause Indicates the FIPS certificate within the Crypto Module - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 536
, KEK: . Probable Cause Indicates an attempt to store Crypto Module internal data using the Secret Encryption Key failed most likely, the EE has been zeroized or tampered with. Recommended Run initEE and regEE, then recover or - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 537
compare failure: successive values match. Probable Cause Indicates the Crypto Module internal random number generator failed. Recommended Contact technical support. Action Severity ERROR SPC-3015 Message , [SPC-3015], ,, ERROR, , - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 538
77 SPC-3015 480 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 539
, [SPM-1003], ,, INFO, , Set New Group Cfg SC Enable KV Type . Probable Cause User configured. Recommended No action is required. Action Severity INFO SPM-1004 Message Probable Cause , [SPM-1004], ,, INFO - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 540
. Action Severity INFO SPM-1005 Message , [SPM-1005], ,, INFO, , Set EE Control slot action . Probable Cause User configured. Recommended No action is required. Action Severity INFO SPM-1006 Message , [SPM-1006], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 541
Severity ERROR SPM-1010 Message , [SPM-1010], ,, ERROR, , Key Vault Certificate is missing. Probable Cause User configured. Recommended Deregister and register this key vault. Action Severity ERROR Fabric OS Message Reference 483 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 542
78 SPM-1010 484 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 543
ip>. Probable Cause Indicates the supportSave command was used to transfer support information to a remote location. Recommended No action is required. command to set the FTP or SCP parameters. Action After the problem is corrected, rerun the supportSave command. Severity WARNING SS-1002 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 544
possible errors in subcommands being executed by the supportSave command. Recommended Run the usbstorage command to check the USB storage device settings. After the USB problem is Action corrected, rerun the supportSave command. Severity WARNING 486 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 545
upgrade. Allow the firmwareDownload command to continue without disruption. Do not fail over or power down the system during firmware upgrade. No action is required. Run the firmwareDownloadStatus command for more information. Severity WARNING SULB-1002 Message , [SULB-1002], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 546
>, [SULB-1007], ,, INFO, , Standby CP reboots. Probable Cause Indicates the standby CP is rebooting with new firmware. Recommended Action No action is required. The firmwareDownload command is progressing as expected. Run the firmwareDownloadStatus command for more - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 547
failed on Standby CP." "firmwareCommit failed on Standby CP." "firmwareDownload failed." "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "firmwareDownload failed due to IPC error." "firmwareDownload failed due to IPC error." "Standby - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 548
secondary partition. Please use firmwareDownloadStatus and firmwareShow to see firmware status." "firmwareDownload has started on Standby CP. up." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareDownload has completed successfully on Standby CP." - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 549
0x7f "Standby CP reboots." 0x80 "Standby CP failed to reboot." 0x81 "Standby CP booted up with new firmware." 0x82 "Standby CP failed to boot up with new firmware." 0x83 "There was an unexpected reboot during firmwareDownload. The command is aborted." 0x84 "Standby CP was not responding - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 550
required package list file. Check whether the switch is supported by the requested firmware. Also check firmwareDownload help page for other possible your service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package." 0x15 "Unable to create firmware version file - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 551
firmware, or contact your service provider for recovery." 0x25 "The post-install firmware on the switch may be two releases older than the requested firmware. firmwareDownload supports firmware , retry the firmwareDownload command. If the problem persists, contact your system administrator. 0x18 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 552
coredump files using the supportSave command before proceeding. 0x29 - The pre-install script failed. This error may be caused by an unsupported blade type networking issues. Please reload firmware packages on the file server, then retry firmwareDownload. If the problem persists, contact your system - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 553
to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting information. Severity INFO SULB-1010 Message another firmwareDownload. If the problem persists, contact your switch service provider. Fabric OS Message Reference 495 53-1001157- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 554
and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1020 Message , [SULB-1020], AUDIT, ERROR, , New firmware failed to boot in slot . Probable Cause Indicates the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 555
. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message , [SULB-1024], AUDIT, WARNING, , Firmware commit has completed on the blade in slot . Probable - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 556
in slot will reboot with the new firmware. Probable Cause Indicates new firmware has been downloaded to the specified AP blade and that command to monitor progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 557
switch. Recommended Run the firmwareShow command to verify the firmware versions. Run the switchShow command to Action make sure firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider. Severity ERROR SULB-1035 Message , - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 558
error may be caused by inconsistent internal firmware image. It may also be caused by relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB , HCL failed. Reboot the switch manually using the reboot command. However, it will disrupt - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 559
Switch enable failed switch status= 0x, c_flags = 0x. Probable Cause Indicates the switch is enabled before it is ready then run the Action supportSave command and contact your switch service provider. Severity ERROR SWCH-1002 Message , [SWCH-1002 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 560
>). Probable Cause Indicates the standby control processor (CP) does not support N_Port ID Virtualization (NPIV) functionality and the switch has some NPIV devices logged into the fabric. Recommended Load a firmware version on standby that supports NPIV functionality, using the firmwareDownload - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 561
that already has area swapped. Recommended Action Replace the blade with ports that support port swap. Then port swap the ports back to ports default area. Refer to the Fabric OS Administrator's Guide for more information on port swapping. Severity WARNING SWCH-1009 Message , [SWCH - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 562
; Otherwise '0'>). Probable Cause Indicates the standby control processor (CP) does not support Trunk Area functionality, but the switch has some ports with Trunk Area enabled. Recommended Load a firmware version on standby that supports Trunk Area functionality, using the Action firmwareDownload - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 563
services or to fail over to active status. Recommended Action The switch is in an inconsistent state and can be corrected only by a reboot or power cycle. Before rebooting the chassis, record the firmware version on the switch or control processor (CP) and run the haDump command. If this is a dual - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 564
platform running this firmware. Note that the chassisConfig option 1 should be valid for all platforms running any valid firmware. Severity CRITICAL SYSC action fails. Recommended Use the supportSave command to gather troubleshooting data. Issue a reboot or haFailover Action command to recover - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 565
SYSM-1002], ,, INFO, , , Switch: Probable Cause Indicates a user has executed either the switchShutdown or switchReboot command. All services are brought down for a logical switch. Recommended Action No action is required if the switchShutdown - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 566
number>,, WARNING, , PERMITTING USE OF INCOMPATIBLE CHASSIS FOR CP IN SLOT . DATA ERRORS MAY RESULT. Probable Cause Over-riding the incompatible control processor (CP)/chassis check. For engineering use only. Recommended Delete the /var/chassis_backplane_override file and - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 567
Chapter TAPE System Messages 84 TAPE-1001 Message , [TAPE-1001], , FFDC, INFO, , Key acquisition for . Probable Cause Indicates that the key acquisition for the pool or the container has begun or is complete. - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 568
84 TAPE-1001 510 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 569
the dump. (PANIC DUMP, WATCHDOG EXPIRED, MANUAL, TRIGGER)>) Probable Cause Indicates that trace dump supportSave command Action and contact your switch service provider. Severity WARNING TRCE-1002 Message FTP address ' '. Probable Cause Indicates that a trace - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 570
transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR TRCE-1004 Message , [TRCE-1004 FTP Connectivity Test succeeded to FTP site ' '. Probable Cause Indicates that a connectivity test to the FTP - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 571
unable to read stored trace parameters. Recommended Action Reboot the CP (dual-CP system) or restart the switch. If the message persists, run FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL TRCE-1009 Message , [TRCE-1009], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 572
brief delay. Recommended Action If the message persists, reboot the CP (dual-CP system) or restart the switch. Run supportFtp (as needed) to switch service provider. Severity ERROR TRCE-1011 Message , [TRCE-1011], ,, INFO, , Trace dump manually - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 573
Chapter TRCK System Messages 86 TRCK-1001 Message , [TRCK-1001], ,, INFO, , Successful login by user . Probable Cause Indicates the track change feature recorded a successful login. Recommended No action is required. Action Severity INFO TRCK- - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 574
86 TRCK-1005 Probable Cause Indicates the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration file in nonvolatile memory, including a configDownload. This message is not generated for a configUpload. All - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 575
issues to the external clock server or if the fabric is configured for external time synchronization but the principal or primary FCS does not support the feature. If the message does not recur, it should be ignored. Recommended Action Run the tsClockServer command to verify that the principal or - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 576
event is occurring or has failed. The message might be one of the following: • Init failed. Time Service exiting Probable Cause: Initialization error, Time Server exits. • Synchronizing time of day clock Probable Cause: Usually logged during temporary operational issues when the clock goes - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 577
87 TS-1008 Fabric OS Message Reference 519 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 578
87 TS-1008 520 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 579
Chapter UCST System Messages 88 UCST-1003 Message , [UCST-1003], ,, INFO, , Duplicate Path to Domain , Output Port = , PDB pointer = 0x Probable Cause Indicates that duplicate paths were reported to the specified domain - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 580
88 UCST-1025 UCST-1025 Message , [UCST-1025], ,, INFO, , In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 581
Chapter UPTH System Messages 89 UPTH-1001 Message , [UPTH-1001], ,, WARNING, , No minimum cost path in candidate list Probable Cause Indicates the specified switch is unreachable because no minimum cost path (FSPF UPATH) exists in the candidate list ( - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 582
89 UPTH-1001 524 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 583
file -- HTTPS is configured but could not be started. Probable Cause Indicates the SSL key file is either invalid or absent. Recommended Install a valid key file. Action Severity WARNING WEBD-1004 Message , [WEBD-1004], ,, INFO, , HTTP server will be - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 584
server cannot be started. Probable Cause Indicates a rare error condition, where the built-in recovery process has failed to restore HTTP services. The problem often results from invalid configuration of SSL certificates, but there can be more than one reason for such a failure. Recommended No - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 585
persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command to save these core files and contact your switch service provider. Severity ERROR Fabric OS Message Reference 527 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 586
91 ZOLB-1001 528 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 587
port login (PLOGI) trap processing. This messages usually indicates problems when adding content-addressable memory (CAM) entries before the transfers; then run the Action supportSave command and contact your switch service provider. Severity WARNING ZONE-1003 Message , [ZONE-1003], - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 588
92 ZONE-1005 In session-based zoning, the zone enforcement is checked by the software. In hardware-enforced zoning, zone or alias members are defined using exclusively or using WWNs exclusively: that is, using one method or the other to define all objects in the zoning database. - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 589
a programming error when adding content-addressable memory (CAM) entries before the filter setup. Recommended Action There are two ways to avoid this problem. • Avoid having too many hosts zoned with a set of target devices at a single port. • Avoid having too many zones directed at a single - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 590
configuration is enabled on the switch, it will not be supported. Recommended Edit the zone database to remove the QuickLoop zoning name>. Probable Cause Indicates the required zoning license is missing. Recommended Install the zoning license using the licenseAdd command. Refer to your switch - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 591
= 3) • FA zone (value = 5) QuickLoop zones are not supported in Fabric OS v4.x and above. Recommended If the message persists, supportSave command and contact your switch service provider. Severity ERROR ZONE-1019 Often this message indicates a transitory problem. Wait a few minutes and retry - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 592
run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity INFO ZONE-1024 Message , [ZONE-1024], ,, INFO, , . Probable Cause Indicates the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 593
• Unknown: An error was received for an unknown reason. • User Command: A user aborted the current zoning transaction. • Switch Shutting Down: The switch . Refer to the Fabric OS Administrator's Guide for information on the zone database sizes supported for each switch. Severity WARNING ZONE-1029 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 594
FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING ZONE-1030 Message , [ZONE-1030], -name>, Switch is in interop mode. (switch, port) members not supported. Probable Cause Indicates the switch is set to interop mode using the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 595
92 ZONE-1034 Probable Cause Indicates the specified domain has the lowest memory available for the zone database in the fabric. The zone database must be smaller than the memory available on this domain. Recommended Reduce the size of the zone database and retry the operation. Action Severity ERROR - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 596
92 ZONE-1037 ZONE-1037 Message , [ZONE-1037], ,, ERROR, , Unable to examine : error message . Probable Cause Indicates the Fabric OS cannot examine the zone configuration file. Typically the zone configuration is - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 597
92 ZONE-1041 Severity INFO ZONE-1041 Message , [ZONE-1041], ,, WARNING, , Unstable link detected during merge at port (). Probable Cause Indicates a possible unstable link or faulty cable. Recommended Check the SFP and cable at the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 598
action is required. Action Severity INFO ZONE-1047 Message , [ZONE-1047], ,, INFO, , Switch domain () does not support defined database. Probable Cause Indicates a remote Brocade switch is running a downlevel version of Fabric OS that does not - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 599
92 ZONE-1049 ZONE-1049 Message , [ZONE-1049], ,, ERROR, , ZONE AD-DefZone conflict detected while system initialization. Probable Cause Indicates that there is an AD-DefZone conflict. Recommended Check and resolve the default zone mismatch issue. Action - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 600
92 ZONE-1053 ZONE-1053 Message , [ZONE-1053], ,, INFO, , The Default Zone state is set to Disabled. Probable Cause Indicates the Interop Default Zone attribute state is disabled. Recommended Verify if the Interop Default Zone attribute state change was - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 601
Audit Log Messages Section II This section provides the Audit messages, including: •AUDIT AG System Messages 545 •AUDIT AUTH System Messages 547 •AUDIT CONF System Messages 551 •AUDIT FCIP System Messages 553 •AUDIT FICU System Messages 555 •AUDIT FW System Messages 557 •AUDIT HTTP System - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 602
- HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 603
Chapter AUDIT AG System Messages 89 AG-1029 Message AUDIT, , [AG-1029], INFO, CFG, , , , F_Port to N_Port mapping has been updated for N_Port . Probable Cause Indicates that the F_Ports mapped to an N_Port have changed and the config - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 604
89 AG-1029 546 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 605
been changed from [] to []. Probable Cause Indicates that an authentication configuration value was set to a specified value. The data type is "authentication type", "DH group type", "Hash type", or "policy type". Recommended No action is required. Action Severity INFO AUTH - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 606
portEnable commands. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO 548 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 607
persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO AUTH-3008 Message AUDIT, , [AUTH-3008], INFO, SECURITY, , , , Event: - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 608
90 AUTH-3008 550 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 609
Chapter AUDIT CONF System Messages 91 CONF-1000 Message AUDIT, , [CONF-1000], INFO, CFG, , , , configDownload completed successfully. . Probable Cause The configDownload process was initiated and completed - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 610
91 CONF-1022 552 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 611
Chapter AUDIT FCIP System Messages 92 FCIP-1002 Message AUDIT, , [FCIP-1002], INFO, CFG, , , , An IPsec/IKE policy was added. Probable Cause Indicates that an IPsec/IKE policy was added and the config file was updated. Recommended No action - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 612
92 FCIP-1003 554 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 613
Chapter AUDIT FICU System Messages 93 FICU-1011 Message AUDIT, , [FICU-1011], INFO, CFG, , , , FMS mode has been enabled. Probable Cause Indicates the FICON Management server mode has been enabled. Recommended No action is required. Action - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 614
93 FICU-1012 556 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 615
Chapter AUDIT FW System Messages 94 FW-3001 Message AUDIT, , [FW-3001], INFO, , , , Event: , Status: success, Info: Probable Cause Indicates that Port Fencing was enabled/disabled successfully. Recommended No - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 616
94 FW-3001 558 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 617
appropriate action as defined by your enterprise security policy. Severity INFO HTTP-1003 Message AUDIT, , [HTTP-1003], INFO, ZONE, , , , Zoning transaction initiated by User: , Role: could not be completed successfully - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 618
95 HTTP-1003 560 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 619
Chapter AUDIT IPAD System Messages 96 IPAD-1002 Message AUDIT, , [IPAD-1002], INFO, CFG, , , , Switchname has been successfully changed to . Probable Cause Indicates that a change with the switch name has occured. Recommended No - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 620
96 IPAD-1002 562 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 621
Chapter AUDIT PORT System Messages 97 PORT-1006 Message AUDIT, , [PORT-1006], INFO, CFG, , , , Configuration changed for port (ID: ) in No_Module or No_Light state. Probable Cause Indicates the configuration changes were made to - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 622
97 PORT-1009 Probable Cause Indicates a GigE port has been disabled. Recommended No action is required. Action Severity INFO 564 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 623
was planned, no action is required. If the security mode change was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3002 Message AUDIT, , [SEC-3002], INFO, SECURITY, , , , Event: - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 624
was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3004 Message AUDIT, , Removed members from policy . Indicates a user has removed the specific members from the specified security policy. Note - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 625
was planned, no action is required. If the removal of members was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3007 Message AUDIT, , [SEC-3007], INFO, SECURITY, , , , Event: - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 626
as defined by your enterprise security policy. Severity INFO SEC-3013 Message Probable Cause AUDIT, , [SEC-3013], INFO, SECURITY, , , , Event: , Status: success, Info: Security Version stamp is reset. Indicates a user has reset the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 627
-in user service (RADIUS) configuration. Recommended Action Verify the RADIUS configuration was changed intentionally. If the RADIUS configuration was intentionally changed, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 628
Info>. Probable Cause Indicates a user has changed the remote authentication dial-in user service (RADIUS) configuration. Recommended Action event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3020 Message AUDIT, , [ - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 629
not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3021 Message AUDIT, < : Successful logout by user []. Probable Cause Indicates the specified user has successfully logged out may manually unlock the account. Severity INFO Fabric OS - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 630
, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3025 Message AUDIT, , [SEC-3025], INFO, SECURITY, , , , Event: , Status: success, Info: User account [] added. Role: [ - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 631
action as defined by your enterprise security policy. Severity INFO SEC-3029 Message AUDIT, , [SEC-3029], INFO, SECURITY, , , , Event: , Status: success, Info: Backup user account \"\" recovered. Probable Cause - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 632
was not Action planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3032 Message AUDIT, , [ Fabric wide configuration set to . Probable Cause Indicates the specified event has occurred. Recommended - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 633
event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3036 Message AUDIT, , [SEC-3036], INFO, SECURITY, , , , Event: ipfilter - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 634
Check for unauthorized access to the switch through the specified protocol connection. Take Action appropriate action as defined by your enterprise security policy. Severity INFO SEC-3040 Message AUDIT, , [SEC-3040], WARNING, [ license ] going to expire in - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 635
event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3045 Message AUDIT, , [SEC Probable Cause Indicates the user does not have permission to execute this command. Recommended Verify the user has the required permission - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 636
event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3049 Message AUDIT, , [SEC-3049], INFO, SECURITY, , , Status of bootprom - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 637
, Incorrect SNMP configuration. Probable Cause Indicates that the simple network management protocol (SNMP) configuration s incorrect and the SNMP service will not work correctly. Recommended Reset the SNMP configuration to default. Action Severity ERROR SNMP-1005 Message Probable Cause AUDIT - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 638
99 SNMP-1006 580 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 639
, , Firmwaredownload command has completed successfully. Probable Cause Indicates the firmwareDownload command has completed successfully and switch firmware has been updated. Recommended Action No action is required. The firmwareDownload command has completed as expected. Run the - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 640
failed on Standby CP." "firmwareCommit failed on Standby CP." "firmwareDownload failed." "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "firmwareDownload failed due to IPC error." "firmwareDownload failed due to IPC error." "Standby - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 641
secondary partition. Please use firmwareDownloadStatus and firmwareShow to see firmware status." "firmwareDownload has started on Standby CP. up." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareDownload has completed successfully on Standby CP." - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 642
0x7f "Standby CP reboots." 0x80 "Standby CP failed to reboot." 0x81 "Standby CP booted up with new firmware." 0x82 "Standby CP failed to boot up with new firmware." 0x83 "There was an unexpected reboot during firmwareDownload. The command is aborted." 0x84 "Standby CP was not responding - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 643
required package list file. Check whether the switch is supported by the requested firmware. Also check firmwareDownload help page for other possible your service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package." 0x15 "Unable to create firmware version file - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 644
firmware, or contact your service provider for recovery." 0x25 "The post-install firmware on the switch may be two releases older than the requested firmware. firmwareDownload supports firmware , retry the firmwareDownload command. If the problem persists, contact your system administrator. 0x18 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 645
files using the supportSave command before proceeding. 0x29 - The pre-install script failed. This error may be caused by an unsupported blade type networking issues. Please reload firmware packages on the file server, then retry firmwareDownload. If the problem persists, contact your system - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 646
the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting information. Severity INFO SULB problem persists, contact your switch service provider. Severity ERROR SULB-1018 Message Probable Cause AUDIT, , [SULB-1018], ERROR, FIRMWARE - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 647
the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1021 Message AUDIT, , [SULB-1021], WARNING, FIRMWARE, , , , Firmware is being downloaded to the blade in slot - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 648
command to monitor the progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message AUDIT, , [SULB-1024], WARNING, FIRMWARE, , , , Firmware commit has completed on the blade in slot - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 649
command to monitor progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message AUDIT, , [SULB-1032], WARNING, FIRMWARE, , , , Relocating an internal firmware image on the CP. Probable Cause - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 650
to be relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1037 Message AUDIT, , [SULB-1037], ERROR, FIRMWARE, , , , HCL failed. Reboot the switch manually using the reboot command. However - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 651
AUDIT SWCH System Messages Chapter 101 SWCH-1012 Message AUDIT, , [SWCH-1012], INFO, CFG, , , , Trunk Area () has been enabled for one or more ports. Probable Cause Indicates a Trunk Area has been enabled for one or more ports and - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 652
101 SWCH-1014 594 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 653
AUDIT UCST System Messages Chapter 102 UCST-1021 Message AUDIT, , [UCST-1021], INFO, CFG, , , , In-order delivery option has been enabled. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 654
102 UCST-1024 UCST-1024 Message AUDIT, , [UCST-1024], INFO, CFG, , , , Dynamic Load Sharing option has been disabled. Probable Cause Indicates the DLS option has been disabled for the switch. Recommended No action is required. Action Severity - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 655
Severity INFO 102 UCST-1027 Fabric OS Message Reference 597 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 656
102 UCST-1027 598 Fabric OS Message Reference 53-1001157-01 - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 657
the event was planned, no action is required. If the event was not Action planned, take appropriate action as defined by your enterprise security policy. Severity INFO ZONE-3002 Message AUDIT, , [ZONE-3002], INFO, ZONE, , , , Event: - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 658
the event was planned, no action is required. If the event was not Action planned, take appropriate action as defined by your enterprise security policy. Severity INFO ZONE-3004 Message AUDIT, , [ZONE-3004], INFO, ZONE, , , , Event: - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 659
the event was planned, no action is required. If the event was not Action planned, take appropriate action as defined by your enterprise security policy. Severity INFO ZONE-3008 Message AUDIT, , [ZONE-3008], INFO, ZONE, , , , Event: - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 660
the event was planned, no action is required. If the event was not Action planned, take appropriate action as defined by your enterprise security policy. Severity INFO ZONE-3012 Message AUDIT, , [ZONE-3012], INFO, ZONE, , , , Event: - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 661
event was planned, no action is required. If the event was not Action planned, take appropriate action as defined by your enterprise security policy. Severity INFO ZONE-3016 Message AUDIT, , [ZONE-3016], INFO, FABRIC, , , , Event: - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 662
event was planned, no action is required. If the event was not Action planned, take appropriate action as defined by your enterprise security policy. Severity INFO ZONE-3019 Message AUDIT, , [ZONE-3019], INFO, FABRIC, , , , Event: - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 663
event was planned, no action is required. If the event was not Action planned, take appropriate action as defined by your enterprise security policy. Severity INFO ZONE-3025 Message Probable Cause Recommended Action AUDIT, , [ZONE-3025], INFO, FABRIC, , - HP 8/24 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April - Page 664
103 ZONE-3025 Severity INFO 606 Fabric OS Message Reference 53-1001157-01
53-1001157-01
24 November 2008
Fabric OS
Message Reference
Supporting Fabric OS v6.2.0