HP BladeSystem c3000 HP BladeSystem c3000 Tower Enclosure Setup and Installati
HP BladeSystem c3000 Manual
View all HP BladeSystem c3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP BladeSystem c3000 manual content summary:
- HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 1
HP BladeSystem c3000 Tower Enclosure Setup and Installation Guide Part Number 457022-002 August 2008 (Second Edition) - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 2
are U.S. registered trademarks of Microsoft Corporation. Intended audience This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 3
19 Installing a full-height blade ...20 Installing a half-height blade ...26 Installing fans...29 Installing an HP BladeSystem c3000 KVM module 30 Installing interconnect modules ...33 Cabling and powering up the enclosure 44 Cabling the enclosure ...44 HP BladeSystem Onboard Administrator cabling - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 4
Blade or Port Info screen ...56 Turn Enclosure UID On/Off screen 57 View User Note screen...59 Chat Mode screen ...59 Troubleshooting ...60 Troubleshooting resources ...60 Important safety information...60 Symbols on equipment ...60 Warnings and cautions ...61 Insight Display errors ...62 Power - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 5
the installation Pallet contents Item 1 2 3 4 5 6 7 8 Name HP BladeSystem c3000 Tower Enclosure Device bay blank Power supply blank Power supply (quantity as ordered) Half-height device (quantity as ordered) Full-height device (quantity as ordered) HP c-Class Blade SUV cable (local I/O cable) Fan - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 6
as ordered) Onboard Administrator tray Onboard Administrator module DVD drive Onboard Administrator blank Interconnect blank Documentation CD SmartStart CD Printed installation instructions Installation checklist Description A fan used to cool the components installed in the enclosure The module - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 7
drives and the internal system components to cool before touching them. WARNING: To reduce the risk of electric shock or damage to the equipment, enter enclosures or perform service on system components only as instructed in the user documentation. Planning the installation 7 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 8
all power supplies installed in the enclosure. To determine the total amperage draw of your HP BladeSystem c3000 Tower Enclosure configuration, see the HP power calculator (http://www.hp.com/go/bladesystem/powercalculator). Only trained service personnel must perform installation and maintenance - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 9
or the user documentation supplied with that option. WARNING: To reduce the risk of personal injury, fire, or damage to the equipment, do not overload the AC supply branch circuit that provides power to the enclosure. Consult the electrical authority having jurisdiction over wiring and installation - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 10
is wired to an industrial-style plug. NEMA locking-style plugs or those complying with IEC 60309 are considered suitable for this purpose. Using common power outlet strips to supply power to this equipment is not recommended. Planning the installation 10 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 11
CD/DVD-ROM drive (optional) Onboard Administrator tray (reserved for future use) Insight Display Onboard Administrator tray containing Onboard Administrator 1 Device bay numbering Each enclosure requires interconnects to provide network access for data transfer. Interconnects reside in bays located - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 12
Full-height device bay numbering Half-height device bay numbering Identifying components and LEDs 12 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 13
navigates to the selected menu Moves the menu or navigation bar selection left one position Moves the menu or navigation bar selection right one position HP BladeSystem Onboard Administrator components Identifying components and LEDs 13 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 14
7 8 9 Description Reserved for future use Interconnect bay 1 Fan bays ("Fan bay numbering" on page 15) Interconnect bay 2 Enclosure link-down port Enclosure link-up port Onboard Administrator 1/iLO port Optional KVM module bay Power supply bays ("Power supply bay numbering" on page 16) Identifying - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 15
Item 10 11 Description Interconnect bay 4 Interconnect bay 3 Fan bay numbering Fan LEDs LED color Solid green Solid amber Flashing amber Fan status The fan is working. The fan has failed. See the Insight Display screen. Identifying components and LEDs 15 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 16
Power supply bay numbering Power supply LED Power LED (green) Off On Off Failure LED (amber) Off Off On Status No AC power to power supply units AC present. Standby output on. Power supply DC output on and OK Power supply failure (includes overvoltage and overtemperature) Identifying components - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 17
bay numbering To support network connections for specific signals, install the interconnect module in the appropriate bay. Server blade signal NICs 1, 2, 3, and 4 (embedded) Mezzanine 1 Mezzanine 2 Mezzanine 3 Interconnect bay number 1 Interconnect bay label Notes - 2 Four port cards - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 18
in step 1. 5. Lock the enclosure wheels. Component installation The following sections contain installation instructions for the individual enclosure components. All components must be installed and cabled before you power up the enclosure. There is no specific installation order requirement for the - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 19
"Power supply bay numbering (on page 16)." 2. Install power supply blanks in any unused power supply bay. Populating power supply bays For AC redundant (N+N power supplies) configurations, an even number of power supplies is required. For this configuration, where N is the number of power supplies - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 20
a full-height blade The enclosure ships with device bay shelves to support half-height devices. To install a full-height device, remove the device bay shelf and the corresponding blanks. To install a full-height blade: 1. Remove the blank. 2. Remove the three adjacent blanks. 3. Remove the - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 21
plan to install six HP Active Cool Fans, blades can be installed in any configuration. For more information, see "Installing fans" and "Full-height device bay numbering (on page 12)." CAUTION: To prevent improper cooling and thermal damage, do not operate the blade or the enclosure unless all hard - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 22
Removing the device bay dividers 1. Remove the blank. Installing components 22 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 23
2. To open the divider locking tab: Installing components 23 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 24
o If you are using a device bay blank that came with the enclosure, the coupler plate can be found with the contents of the full-height device shipping box. o If you are using a device bay blank that you purchased as an option, remove the coupler plate from inside the blank. Installing components 24 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 25
the bottom of the second blank on to the tabs on the coupler plate, and slide the second blank forward until it snaps in place. 4. Install the full-height blank in to the device bay - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 26
plan to install four HP Active Cool Fans, you can install up to four half-height blades. Populate the device bays in the following order: 1, 2, 5, 6. If you plan to install six HP Active Cool Fans, blades can be installed in any configuration. For more information, see "Installing fans" and "Half - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 27
four adjacent half-height devices. The mini divider adds support for two half-height and one full-height adjacent devices. 1. Remove the full-height blade, storage blade, or device bay blank. 2. Install the mini divider (proceed to step 3 to install the half-height divider): a. Align the three tabs - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 28
Slide the mini divider locking tab up to lock it. 3. Install the half-height divider: a. Slide the half-height divider locking tab down. b. Align the three tabs on the left edge of the half-height divider with the openings in the enclosure, and then rotate the half-height divider counter-clockwise - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 29
up to lock it. Installing fans NOTE: The HP BladeSystem c3000 Tower Enclosure is shipped with four HP Active Cool fans and supports up to six fans. Install fans based on the number of blades installed: • For one to four half-height blades or one to two full-height blades, install four fans in bays - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 30
HP IP Console Switch using the HP USB Interface Adapter. To use the c3000 KVM module, you must have HP BladeSystem Onboard Administrator version 2.10 or later installed. For more information on using the c3000 KVM module software, see the HP BladeSystem Onboard Administrator User Guide. Installing - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 31
To install a c3000 KVM module: 1. Press the tab, and then pull the KVM module blank from the enclosure. 2. Slide the c3000 KVM module into the bay. When fully inserted, the device locks into place. Attaching components to the c3000 KVM module For local access to the enclosure: 1. Connect a monitor - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 32
the optional USB interface adapter to the video connector and to one of the USB connectors on the c3000 KVM module. 2. Connect the CAT5 end of the KVM Interface adapter to an optional HP Console Switch. Removing the c3000 KVM module 1. Disconnect all cables from the c3000 KVM module. Installing - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 33
for a gigabit Ethernet switch or pass-through. Installation into the remaining interconnect bays depends on the type and location of the mezzanine card installed in the blade. To verify compatibility with the enclosure, see the documentation that ships with the interconnect module. IMPORTANT: If the - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 34
To install an interconnect module: 1. Remove the interconnect blank. 2. If you are installing a double-wide interconnect module, remove the interconnect bay dividers ("Removing interconnect bay dividers" on page 40). 3. Install the interconnect module in the enclosure. Mapping to interconnect ports - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 35
blades The following table lists the available configurations for half-height devices installed in device bay N (1-8) Connection Port number Embedded NIC NIC 1 NIC 2 Mezzanine slot 1-1x or 1x/2x port 1 2x cards (4x cards are 1x/2x port 2 not supported in this slot) Connects to interconnect - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 36
full-height blades Connects to interconnect bay/port 3/Port N 4 Port N 3/Port N+8 4/Port N+8 3/Port N 3/Port N+8 Comments One or two single-wide interconnect modules One double-wide interconnect module The following table lists the available configurations for full-height devices installed in - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 37
1x or 2x cards (4x cards are not supported in this slot) 1x/2x port 1 1x interconnect module One single-wide interconnect module One or two single-wide interconnect modules One double-wide interconnect module One or two single-wide interconnect modules One double-wide interconnect module Installing - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 38
Mapping BL2x220c blades To support network connections for specific signals, install an interconnect module in the bay corresponding to the embedded NIC or mezzanine signals. Connection Embedded NIC Port number Server A: NIC 1 Server A: NIC 2 Server B: NIC 1 Connects to interconnect Comments bay - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 39
PCIe module to a partner blade such as a tape blade or a PCI expansion blade. For full-height blades, these signals are used to connect a PCIe module to a partner blade in the lower adjacent bay and require a PCIe pass-thru mezzanine card installed in mezzanine connector 3. The Onboard Administrator - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 40
. The Onboard Administrator disables the interconnect bay crosslinks in instances where the crosslinks cannot be used, such as when two different modules reside in adjacent horizontal interconnect bays. Removing interconnect bay dividers The enclosure ships with interconnect bay dividers installed - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 41
To reinstall an interconnect bay divider, align the interconnect bay divider with the rail, and slide the divider into the enclosure until it locks into place. Installing the enclosure/Onboard Administrator link module 1. Slide the enclosure/Onboard Administrator link module into the bay until the - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 42
to the second USB connector. Item 1 2 3 4 5 6 Description Monitor USB mouse HP c-Class Blade SUV cable Server blade Video connector USB keyboard Accessing local media devices Use the following configuration when configuring a blade or loading software updates and patches from a USB CD/DVD-ROM or - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 43
: The Onboard Administrator with version 2.0 or greater firmware supports attaching a CD or DVD to any or all iLOs using the optional enclosure DVD drive or an external HP DVD drive for operating system installation or software updates. See "Enclosure Settings screen (on page 55)" in this guide for - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 44
with the interconnect modules, or the HP ProLiant BL System Best Practices Guide on the Documentation CD or the HP website (http://www.hp.com/go/bizsupport). 3. Connect to the AC or DC power source in your facility and power up the enclosure. HP BladeSystem Onboard Administrator cabling Cabling - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 45
on using the Remote Onboard Administrator feature, see the HP BladeSystem Onboard Administrator User Guide. Cabling the network to the enclosure Cable the interconnect modules to the enclosure. See "Mapping to interconnect ports (on page 34)" and the supporting documentation that came with your - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 46
AC circuit breakers that power the power cables installed in the enclosure. When the enclosure powers up for the first time, several minutes might pass before all blades are initialized and recognized by the Onboard Administrator. Complete initialization depends on the number of blades configured - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 47
information on driver and firmware updates, see the HP website (http://www.hp.com/go/blades/). Running the Insight Display installation steps When the enclosure is powered up for the first time, the Insight Display launches an installation wizard to guide you through the configuration process. After - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 48
All, and press the OK button to accept the current settings. You can change the following options in the Enclosure Settings screen: Power Mode-The default setting is AC Redundant. The following selections are valid: o AC Redundant o Power Supply Redundant Using the HP BladeSystem Insight Display 48 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 49
, and gateway are set within this option. OA2 IP Addr-If this module is present, the default setting is DHCP; if no IP address is received, the IP address is 0.0.0.0. If only one Onboard Administrator module is installed, the screen will display "Not Present." Enclosure Name-The default setting is - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 50
the end of the name. 5. Navigate to the Accept All button at the bottom of the Enclosure Settings screen, and press the OK button to accept all the settings and continue. 6. In the Check: Linked Enclosures screen, the message "Linked enclosures detected" displays if the Onboard Administrator module - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 51
configuring the current enclosure only. The Insight Display installation wizard must be run on each of the other detected enclosures. Select this option if each enclosure requires different power settings. IMPORTANT: If your facility uses Static IP addressing for the Onboard Administrator modules - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 52
enclosure and should be corrected immediately. 10. Open a browser and connect to the active Onboard Administrator module using the Onboard Administrator IP address that was configured during the Insight Display installation wizard process. 11. Enter the user name and password from the tag supplied - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 53
("HP options: • Health Summary ("Health Summary screen" on page 54) • Enclosure Settings • Enclosure Info ("Enclosure Info screen" on page 55) • Blade or Port Info ("Blade or Port Info screen" on page 56) • Turn Enclosure UID On/Off ("Turn Enclosure UID On/Off screen" on page 57) • View User - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 54
component that is installed but powered off with no errors. The only option active on the navigation bar is Back to Main Menu. Select Back to Main Menu, and press the OK button to return to the main menu. If there is a configuration error between the blade and the interconnect module, the error will - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 55
or detach a CD or DVD loaded in the optional c3000 enclosure DVD drive to any or all blades in the enclosure. This feature can be used to install an operating system or software on the blade(s). If the optional DVD drive is not present, an external HP USB DVD drive can be used with this feature - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 56
Current enclosure ambient temperature • Current AC input power to the enclosure • Enclosure name • Rack name Blade or Port Info screen The Blade or Port Info screen displays information about a specific blade. On the first screen, select the blade number, then press the OK button. Select Blade Info - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 57
connected to particular port numbers on the interconnect modules. Turn Enclosure UID On/Off screen The main menu option displays "Turn Enclosure UID Off" when the enclosure UID is active, and displays "Turn Enclosure UID on" when the enclosure UID is off. Using the HP BladeSystem Insight Display 57 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 58
the color of the Insight Display screen to blue. Selecting Turn Enclosure UID Off from the main menu turns off the rear enclosure UID LED and changes the color of the Insight Display screen to the current condition ("Insight Display overview" on page 47). Using the HP BladeSystem Insight Display 58 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 59
Onboard Administrator user web interface. Both the background bitmap and the text can be changed. Chat Mode screen The Chat Mode screen is used by the remote administrator who uses the web interface to send a message to an enclosure remote Administrator on the web interface for LCD Chat. Using the - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 60
, issue resolution, and software maintenance on ProLiant servers and server blades. This guide includes problemspecific flowcharts to help you navigate complex troubleshooting processes. To view the guide, select a language: • English (http://www.hp.com/support/ProLiant_TSG_en) • French (http://www - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 61
electric shock hazards. The area contains no user or field serviceable parts. Do not open for any reason. WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure. This symbol on an RJ-45 receptacle indicates a network interface connection. WARNING: To reduce the - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 62
. To clear errors that occur after initial powerup and configuration, see the HP BladeSystem Onboard Administrator User Guide for information. The following types of errors can occur when installing and configuring the enclosure: • Power errors (on page 62) • Cooling errors (on page 63) • Location - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 63
user guide on the Documentation CD. Device failure errors Device failure errors occur when a component has failed. Device failure errors can occur on all components, including: • Server blades • Storage blades • Power supplies • Interconnect modules • Onboard Administrator modules Troubleshooting - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 64
• Fans • AC power inputs To correct a device failure error: 1. Use the arrow buttons to 3. Replace the failed component with a spare, if applicable. NOTE: If the device failure error is an AC power input failure error, you must have the failed AC input repaired to clear the error. Troubleshooting 64 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 65
/us/en/wwcontact.html). For HP technical support: • In the United States, for contact options see the Contact HP United States webpage (http://welcome.hp.com/country/us/en/contact_us.html). To contact HP by phone: o Call 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hours a day - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 66
charges, depending on the type of warranty service designated for your product. NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP requires that an authorized service provider replace the part. These parts are identified as "No" in the - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 67
-Verfahren optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. Technical support 67 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 68
gbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen Obligatorio: componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP que realice la sustitución de estos componentes, tendr - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 69
propio cliente de HP, póngase en HP siguiente (http://www.hp.com/go/selfrepair). Customer Self Repair Veel onderdelen in HP HP (of een HP Service HP Service HP Service Partner om via de telefoon technische ondersteuning te ontvangen. HP stico, a HP (ou fornecedores/parceiros de serviço da HP) concluir - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 70
entanto, se desejar que a HP as substitua, pode haver ou HP não são projetadas para o reparo feito pelo cliente. A fim de cumprir a garantia do cliente, a HP HP para que um técnico o ajude por telefone. A HP especifica HP. Nos casos em que isso for necessário, é preciso enviar a peça com defeito à HP - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 71
Technical support 71 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 72
Technical support 72 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 73
installed in a residential environment (for example, personal computers). The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user A digital device, pursuant to Part 15 of the FCC Rules. - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 74
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation 77269-2000 • 1-800-HP-INVENT (1-800-474-6836). part, series, or model number found on the product. Modifications The FCC requires the user - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 75
(used only if applicable-refer to the product label) Hewlett-Packard GmbH, HQ-TRE, Herrenberger Strasse 140, 71034 Boeblingen, Germany Disposal of waste equipment by users in private households in the European Union Regulatory compliance notices 75 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 76
more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product. Japanese notice BSMI notice Korean notice Class A equipment Regulatory compliance notices 76 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 77
than those specified herein or in the laser product's installation guide may result in hazardous radiation exposure. To reduce the risk of exposure to hazardous radiation: • Do not try to open the module enclosure. There are no user-serviceable components inside. • Do not operate controls, make - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 78
authorized HP Partner, or their agents. For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider a qualified Taiwanese recycler for proper battery disposal. Power cord statement for Japan Regulatory compliance notices 78 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 79
This type of damage may reduce the life expectancy of the device. To prevent electrostatic service tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 80
Self Repair ESD electrostatic discharge I/O input/output IEC International Electrotechnical Commission iLO 2 Integrated Lights-Out 2 IP Internet Protocol KVM keyboard, video, and mouse LCD liquid crystal display LED light-emitting diode NEMA National Electrical Manufacturers Association NFPA - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 81
NIC network interface controller PDU power distribution unit TMRA recommended ambient operating temperature UID unit identification UPS uninterruptible power system USB universal serial bus Acronyms and abbreviations 81 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 82
11, 14 components, front panel 11 components, installation 18 components, Onboard Administrator 13 components, rear 14 configuration errors 63 configuration, power supply 19 configuring the enclosure with HP BladeSystem Insight Display 47 contacting HP 65 controller display, LCD 13 cooling errors 63 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 83
13 installation, server blade 20, 26 installing components 18 installing fans 29 installing interconnect bay dividers 40 installing interconnect modules 33 installing KVM module 30 installing PDU 45 installing power supplies 19 interconnect bay crosslinks 40 interconnect bay dividers, installing 33 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 84
13 Onboard Administrator module 41 Onboard Administrator module, cabling 44 ordering cables 44 overview of installation process 18 overview, HP BladeSystem Insight Display 47 P PDU (power distribution unit) 9, 45 phone numbers 65 populating power supply bays 19 port types 34 power configurations 19 - HP BladeSystem c3000 | HP BladeSystem c3000 Tower Enclosure Setup and Installati - Page 85
W warnings 7 website, HP 44 Index 85
HP BladeSystem c3000 Tower Enclosure
Setup and Installation Guide
Part Number 457022-002
August 2008 (Second Edition)