- HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 1
HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure Maintenance and Service Guide Abstract This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels and are - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 3
51 Bottom bezels (c3000 tower enclosure 52 Security panels (c3000 tower enclosure) ...52 Casters (c3000 tower enclosure) ...53 Hot-plug power supply or power supply blank 54 Active Cool 200 fan or fan blank ...55 Active Cool 100 fan ...56 Interconnect blank ...56 Interconnect switch or Pass-Thru - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 4
HP BladeSystem Insight Display components 72 HP BladeSystem Onboard Administrator components 73 Enclosure rear components ...75 Fan bay numbering ...76 Fan LEDs ...77 Power supply bay numbering ...77 Power supply LED ...78 Interconnect bay numbering ...78 KVM module connectors ...80 Specifications - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 5
period HP (or HP service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will permits. If assistance is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 6
pièce défectueuse, HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte l'ensemble des frais le site Web HP (http://www.hp.com/go/selfrepair). Service de garantie "pièces seules" Votre garantie limitée HP peut inclure un service de garantie "pi - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 7
Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 8
CSR-Verfahren zwingend vorgegeben. Wenn Sie den Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen Service berechnet. Reparaciones del propio cliente Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 9
minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR-onderdeel, verzendt - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 10
voor meer informatie over het Customer Self Repair programma van HP. Informatie over Service Partners vindt u op de HP website (http://www.hp.com/go/selfrepair). Garantieservice "Parts Only" Het is mogelijk dat de HP garantie alleen de garantieservice "Parts Only" omvat. Volgens de bepalingen - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 11
No caso desse serviço, a substituição de peças CSR é obrigatória. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço. Customer self repair 11 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 12
Customer self repair 12 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 13
Customer self repair 13 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 14
Customer self repair 14 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 15
Illustrated parts catalog Common mechanical components (c3000 enclosure and c3000 tower enclosure) Item Description 1 Front cage Spare part number - Customer self repair (on page 5) - Illustrated parts catalog 15 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 16
module latch* - - 4 HP BladeSystem c3000 Enclosure 5 Option bay blank 6 Fan blank 7 Power supply blank 8 Interconnect blank 9 Rack require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product. 3No-Some HP - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 17
moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee". 1Mandatory: Obrigatória-Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 18
Illustrated parts catalog 18 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 19
components (c3000 tower enclosure) Item Description 10 Miscellaneous plastics kit a) Top front bezel Spare part number 463501-001 require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product. 3No-Some HP - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 20
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. 3No: Kein-Einige Teile sind nicht - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 21
Illustrated parts catalog 21 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 22
Administrator 486822-001 module* e) Onboard Administrator module blank* 519313-001 f) HP c3000 DDR2 Onboard Administrator 599668-001 module with Rotatable Insight Display 17 HP BladeSystem Insight Display - a) For c3000 enclosure (PATA DVD drive 441831-001 model) Customer self repair (on - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 23
Item Description Spare part number b) For c3000 enclosure (SATA DVD drive 519312-001 model)* 18 CD/DVD-ROM however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product. 3No-Some HP parts are - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 24
moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee". 1Mandatory: Obrigatória-Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 25
Illustrated parts catalog 25 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 26
components Item Description Spare part number 20 Power supply a) c3000 power supply 441830-001 b) HP 1200W -48VDC common slot power 451816-001 supply* c) HP 1200W, 12V hot-plug AC power 498152-001 supply d) HP 1200W Platinum Plus hot-plug AC 660185-001 power supply* 21 Active Cool fan - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 27
Brocade 4Gb SAN switch for HP c-Class 411121-001 BladeSystem, 24 ports* g) Brocade 4Gb SAN Switch for HP 411122-001 c-Class BladeSystem, 24 ports with Power Pack Software* h) Cisco Catalyst Blade Switch 3020 for 432904-001 HP c-Class BladeSystem* i) HP 1/10Gb Virtual Connect Ethernet 399725 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 28
419329-001 c-Class BladeSystem* b) HP 4 Gb Fibre Channel Pass-Thru 416378-001 Module for c-Class BladeSystem* c) HP 10GbE Pass-Thru require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product. 3No-Some HP - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 29
moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee". 1Mandatory: Obrigatória-Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 30
blade power" on page 31). • Power down the enclosure ("Powering down the enclosure" on page 31). • If installed, unlock the security panel. Power down the server blades or workstation blades Before powering down the server blades or workstation blades for any upgrade or maintenance procedures - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 31
enclosure serial number instructions in the Midplane assembly section. Connect all power cables and the enclosure, and all bays are powered on based on OA power delay settings and iLO server automatic power-on settings. PATA CD/DVD-ROM drive IMPORTANT: If you are servicing a c3000 tower enclosure - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 32
. To replace the component, reverse the removal procedure. SATA CD/DVD-ROM drive IMPORTANT: If you are servicing a c3000 tower enclosure with the optional security panels installed, these security panels must be removed before beginning this procedure. To remove the component: 1. Remove the front - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 33
component, reverse the removal procedure. Device bay blank Remove the component as indicated. CAUTION: For best cooling practices, do not operate the enclosure for extended periods with more than one component or blank removed. When removing an active component, replace it with a blank. To replace - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 34
-height or full-height blade CAUTION: This procedure provides instructions for replacement of a failed part only. To change the configuration of components, see the appropriate HP BladeSystem c-Class enclosure setup and installation guide. To remove the component: 1. Identify the proper half-height - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 35
o Full-height blade CAUTION: For best cooling practices, do not operate the enclosure for extended periods with more than one component or blank removed. When removing an active component, replace it with a blank. To replace the component, reverse - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 36
mini-divider: Push the divider toward the back of the enclosure until the divider drops out of the chassis. o c3000 divider: a. Push the divider toward the back of the enclosure until it stops. b. Slide the divider to the left to disengage the tabs from the wall. c. Rotate the divider clockwise - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 37
the release tab and open the handle. 2. Remove the Onboard Administrator tray assembly. CAUTION: For best cooling practices, do not operate the enclosure for extended periods with more than one component or blank removed. When removing an active component, replace it with a blank. To replace the - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 38
38) or Onboard Administrator blank (on page 38) from the DDR2 Onboard Administrator module. CAUTION: For mandatory cooling, do not operate the enclosure for any periods with more than one interconnect component or blank removed. When removing an active interconnect component, replace it with a blank - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 39
an active component, replace it with a blank. To replace the component, reverse the removal procedure. HP BladeSystem Insight Display To remove the component: 1. Power down the enclosure ("Powering down the enclosure" on page 31). 2. Remove the Onboard Administrator tray assembly (on page 36) or the - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 40
Remove the T-10 Torx screw that secures the tray assembly cover, and then remove the cover. o DDR2 Onboard Administrator module: Push the quick release latch, and then remove the cover. Removal and replacement procedures 40 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 41
3. Remove the two T-15 Torx screws from the Insight Display. Disconnect the Insight Display cable from the PCA. 4. Remove the cable router by pulling it to the side and rotating it counterclockwise. Pull the LCD forward and lift it out. Removal and replacement procedures 41 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 42
To replace the component, reverse the removal procedure. When installing the new component, connect the cable first, and then install the Insight Display. IMPORTANT: To ensure proper installation and function of Insight Display, be sure the cable is routed properly as shown in the following figure. - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 43
Front cage c3000 enclosure front cage To remove the component: 1. Power down the server blades or workstation blades (on page 30). 2. Power down the storage blades, if applicable ("Storage and other partner blade power" on page 31). 3. Power down the enclosure ("Powering down the enclosure" on page - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 44
front cage. The rear end of the front cage is heavy and the handholds provide a more balanced location to distribute the weight of the cage during lifting the enclosure. To replace the component, reverse the removal procedure. c3000 tower enclosure front cage To remove the component: 1. Power down - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 45
down the storage blades, if applicable ("Storage and other partner blade power" on page 31). 3. Power down the enclosure ("Powering down the enclosure" on page 31). 4. Remove all half-height and full-height blades ("Half-height or full-height blade" on page 34). 5. Remove the Onboard Administrator - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 46
down the server blades or workstation blades (on page 30). 2. Power down the storage blades, if applicable ("Storage and other partner blade power" on page 31). 3. Power down the enclosure ("Powering down the enclosure" on page 31). 4. Remove all half-height and full-height blades ("Half-height - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 47
down the server blades or workstation blades (on page 30). 2. Power down the storage blades, if applicable ("Storage and other partner blade power" on page 31). 3. Power down the enclosure ("Powering down the enclosure" on page 31). 4. Remove all half-height and full-height blades ("Half-height - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 48
5. Remove the Onboard Administrator tray assembly (on page 36) or the DDR2 Onboard Administrator module (on page 37). 6. Remove the front cage ("Front cage" on page 43). 7. Remove the SATA CD\DVD-ROM drive ("SATA CD/DVD-ROM drive" on page 32). 8. Disconnect the media board cable from the midplane. - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 49
CLI and run the command Show Enclosure Info. For additional information on accessing the CLI, see the HP BladeSystem Onboard Administrator Command Line Interface User Guide on the HP website (http://www.hp.com/go/bladesystem/documentation). To remove the component: 1. Power down the server blades or - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 50
X command, where X represents the enclosure part number. Failure to complete this procedure can cause inaccurate or incomplete information to display in HP SIM and Onboard Administrator. Plastic bezels Bezel ear handle (c3000 enclosure) To remove the component: 1. Power down the server blades or - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 51
the handle. 8. Remove the handle. Repeat for the second handle, if needed. To replace the component, reverse the removal procedure. Top bezel (c3000 tower enclosure) Remove the component as indicated: To replace the component, reverse the removal procedure. Removal and replacement procedures 51 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 52
15 Torx screws that secure the bezel. 5. Remove the bezel. To replace the component, reverse the removal procedure. Security panels (c3000 tower enclosure) To remove the component: 1. Close the HP BladeSystem Insight Display. 2. Unlock the front security panel. Removal and replacement procedures 52 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 53
. Casters (c3000 tower enclosure) To remove the component: 1. Power down the server blades or workstation blades (on page 30). 2. Power down the storage blades, if applicable ("Storage and other partner blade power" on page 31). 3. Power down the enclosure ("Powering down the enclosure" on page - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 54
To remove the component: CAUTION: This procedure provides instructions for replacement of a failed part only. To change the configuration of components, see the appropriate HP BladeSystem c-Class enclosure setup and installation guide. 1. Press the release button. Removal and replacement procedures - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 55
2. Remove the power supply or the power supply blank. CAUTION: For best cooling practices, do not operate the enclosure for extended periods with more than one component or blank removed. When removing an active component, replace it with a blank. To replace the component, reverse - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 56
bay until it clicks. NOTE: You cannot install HP Active Cool 100 fans and HP Active Cool 200 fans in the same enclosure. The Onboard Administrator sends an error message, and you must remove the type of fan with the least number of units installed. NOTE: When installing a fan in the top row of fan - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 57
before beginning this procedure. CAUTION: This procedure provides instructions for replacement of a failed part only. To change the configuration of components, see the appropriate HP BladeSystem c-Class enclosure setup and installation guide. To remove the component: CAUTION: To prevent data - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 58
4. Remove the interconnect switch or Pass-Thru module. CAUTION: For best cooling practices, do not operate the enclosure for extended periods with more than one component or blank removed. When removing an active component, replace it with a blank. To replace the component, reverse - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 59
component: 1. Disconnect all cables from the component. 2. Remove the component as indicated. CAUTION: For best cooling practices, do not operate the enclosure for extended periods with more than one component or blank removed. When removing an active component, replace it with a blank. To replace - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 60
all cables from the KVM module. 2. Press the tab, and then pull the KVM module from the enclosure. To replace the component, reverse the removal procedure. c3000 tower enclosure dust filter To install the dust filters: 1. Line up the dust filter with the notch on the Insight Display pocket in the - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 61
High Low Inspect 1 month 3 months Replace 2 months 6 months Because dust filters are considered consumable products, they are not covered under HP warranty. To purchase a four-pack of replacement dust filters from HP, order part number 500184-B21. Removal and replacement procedures 61 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 62
Cabling HP BladeSystem Onboard Administrator cabling Item 1 2 Connector Description Enclosure Connects to the enclosure link-up port on the enclosure beneath it using a CAT5 patch link-down port cable. Enclosure link-up Connects to the enclosure link-down port on the enclosure above it using - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 63
enclosure. NOTE: The HP BladeSystem c-Class enclosure link ports are not compatible with the HP BladeSystem p-Class enclosure link ports. To link the enclosures, use a standard Category 5 (CAT5) patch cable to connect the enclosure link-down port on the first enclosure to the enclosure link-up port - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 64
1 Monitor 2 Keyboard 3 Mouse To connect the c3000 KVM module to an HP Server Console Switch or an HP IP Console Switch: 1. Connect the optional USB interface adapter to the video connector and to one of the USB connectors on the c3000 KVM module. 2. Connect the CAT5 end of the KVM Interface - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 65
a web browser on the PC and enter the active Onboard Administrator module Service IP address found in the Enclosure Info screen in step 2. 4. Log into the Onboard Administrator. For more information on using Onboard Administrator, see the HP BladeSystem Onboard Administrator User Guide. Cabling 65 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 66
and solutions for troubleshooting HP BladeSystem c-Class enclosures. This guide explains how to use the Insight Display to troubleshoot enclosures, and it includes a flowchart to help you navigate the troubleshooting process. To view the guide, see the HP website (http://www.hp.com/support - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 67
system-specific IML viewers: o For Windows®: IML Viewer o For Linux: IML Viewer Application • From within the iLO user interface • From within HP Insight Diagnostics (on page 66) • From within the Onboard Administrator GUI For more information, see the HP BladeSystem Onboard Administrator User Guide - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 68
Component identification Enclosure front components • c3000 enclosure with DDR2 Onboard Administrator module Item 1 2 3 4 5 Description Device bays ("Device bay numbering" on page 70) CD/DVD-ROM drive Onboard Administrator tray containing Onboard Administrator 2 Insight Display Onboard - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 69
• c3000 enclosure • c3000 tower enclosure Item 1 2 3 4 5 Description Device bays ("Device bay numbering" on page 70) CD/DVD-ROM drive blank or CD/DVD-ROM drive (optional) Onboard Administrator tray (reserved for future use) Insight Display Onboard Administrator - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 70
enclosure. Be sure to review device bay numbering to determine which external network connections on the interconnects are active. IMPORTANT: When looking at the rear of the enclosure, front device bay numbering is reversed. Full-height device bay numbering • c3000 enclosure • c3000 tower enclosure - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 71
Half-height device bay numbering • c3000 enclosure • c3000 tower enclosure Component identification 71 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 72
HP BladeSystem Insight Display components • c3000 enclosure Item 1 2 3 4 5 6 Description Insight Display screen Left arrow button Right arrow button OK button Down arrow button Up arrow button • c3000 tower enclosure Function Displays Main Menu error messages and instructions Moves the menu or - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 73
Displays Main Menu error messages and instructions Moves the menu selection up one selection right one position HP BladeSystem Onboard Administrator components • c3000 enclosure DDR2 OA Item 1 that connects supported USB devices Reset button - • c3000 enclosure dual OA module - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 74
6 Reset button • c3000 tower enclosure Description Serial RS232 DB-9 connector with PC standard pinout Blue = UID on Dark = UID off An LED that indicates which Onboard Administrator is active Green = OK Red = Critical error USB 2.0 Type A connector that connects supported USB devices - Component - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 75
- - Green = Normal Red = OA firmware issue. See the HP Onboard Administrator User Guide on the HP website (http://www.hp.com/go/bladesystem/docum entation). Green = Primary OA module Off = Standby OA module Blue = Activated Off = Deactivated - Enclosure rear components Item 1 2 3 4 5 6 7 8 9 10 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 76
Item Description 11 Interconnect bay 3 Fan bay numbering • c3000 enclosure • c3000 tower enclosure Component identification 76 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 77
Fan LEDs LED color Solid green Solid amber Flashing amber Fan status The fan is working. The fan has failed. See the Insight Display screen. Power supply bay numbering • c3000 enclosure Component identification 77 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 78
is disabled. AC is present. Standby output is on, power supply DC output is on and OK. Power supply failure (includes overvoltage and overtemperature) Interconnect bay numbering To support network connections for specific signals, install the interconnect module in the appropriate bay. Component - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 79
• c3000 enclosure • c3000 tower enclosure Server blade signal NICs 1, 2, 3, and 4 (embedded) Mezzanine 1 Mezzanine 2 Mezzanine 3 Interconnect bay number 1 Interconnect bay label Notes - 2 Four port cards connect to bay 2 3,4 • Four port cards • Ports 1 and 3 connect to bay 3 • Ports 2 and - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 80
NOTE: For information on the location of LEDs and ports on individual interconnect modules, see the documentation that ships with the interconnect module. KVM module connectors Item 1 2 3 Description Video connector for rack monitor or external - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 81
for storage corresponds to a pressure minimum of 70 KPa. Enclosure specifications Specification Product dimensions Height Depth Width Shipping dimensions Height Depth Width Standard enclosure weight * Unboxed Shipping Maximum enclosure weight Unboxed Shipping Value 264.50 mm (10.42 in) 835 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 82
* Includes two power supplies, four fans, and one Onboard Administrator. Specifications 82 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 83
Acronyms and abbreviations CSR Customer Self Repair iLO 2 Integrated Lights-Out 2 OA Onboard Administrator UID unit identification USB universal serial bus Acronyms and abbreviations 83 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 84
documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:[email protected]). Include the document title and part number, version number, or the URL when submitting your feedback. Documentation feedback 84 - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 85
service port 65 enclosure specifications 81 environmental specifications 81 F fan bay numbering 76 fan blank 55 fan LED 77 fans 77 features 68 front cage 43, 44 front components 22, 70, 71, 72, 73 front system components 22 full-height device bay numbering 70 H half-height device bay numbering 71 HP - HP BladeSystem c3000 | HP BladeSystem c3000 Enclosure and c3000 Tower Enclosure - Page 86
-thru module 57 power supply bay numbering 77 power supply LEDs 78 powering down 30, 31 preparation procedures 30 R rear components 26, 75 removal and replacement procedures 30 required tools 30 S security panels, removing 52 spare part numbers 15 specifications 81 specifications, environmental 81
HP BladeSystem c3000 Enclosure and c3000
Tower Enclosure
Maintenance and Service Guide
Abstract
This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing
hazards in products with hazardous energy levels and are familiar with weight and stability precautions for rack installations.
Part Number: 451426-009
February 2013
Edition: 9