HP BladeSystem c7000 Enclosure Setup and Installation Guide Abstract This guide describes identification, operations, setup, configuration and utilities, troubleshooting, regulatory notices, specifications, and technical support. This guide is for an experienced service technician. HP assumes you - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 2
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 3
...14 HP BladeSystem Insight Display components 15 Location Discovery Services ...15 Enclosure rear components ...16 Fan bay numbering ...17 Fan LED...18 Onboard Administrator components 18 HP c7000 Onboard Administrator with KVM components 19 Interconnect bay numbering ...20 Installation ...21 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 4
Insight Display installation steps 65 Navigating the Insight Display ...69 Health Summary screen ...70 Enclosure Settings screen ...73 Enclosure Info screen ...73 Blade and Port Info screen ...74 Turn Enclosure UID On/Off screen 75 View User Note screen...77 Chat Mode screen ...77 Troubleshooting - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 5
Preventing electrostatic discharge ...97 Grounding methods to prevent electrostatic discharge 97 Acronyms and abbreviations...98 Documentation feedback ...100 Index...101 Contents 5 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 6
Planning the installation Verifying the pallet contents Item 1 2 3 4 5 6 7 8 9 10 Name HP BladeSystem c7000 Enclosure Rear cage Device bay blank Power supply blank Enclosure hot-plug power supply (quantity as ordered) Full-height device (quantity as ordered) Half-height device (quantity as ordered - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 7
enclosure 19* Hard copy installation instructions for blades, options, and interconnects 20* Installation checklist The printed installation instructions A checklist to guide you through installation of the enclosure and components * Not shown Rack requirements The enclosure is compatible - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 8
open area to provide adequate airflow through any rack front or rear doors o Adjustable rack rails are shipped with each enclosure: - Minimum rail length: 63.5 cm (25 in) - Maximum rail length: 86.4 cm (34 in) Rack-free environment requirements The HP BladeSystem c7000 Enclosure (referred to as the - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 9
two people support the weight of the enclosure. WARNING: Before installing an enclosure in the rack, be sure that all hot-plug power supplies, server blades, and interconnects are removed from the enclosure. Blanks can be left in the enclosure. WARNING: Be sure to install enclosures starting from - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 10
a power failure. IMPORTANT: Data on the dimensions and weights of HP BladeSystem c-Class components can be found in the HP BladeSystem c-Class Maintenance and Service Guide. The same data can be determined by using the online HP BladeSystem c-Class Sizing Utility. Space and airflow requirements To - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 11
user documentation supplied with that option. WARNING: To reduce the risk of personal injury, fire, or damage to the equipment, do not overload the AC supply branch circuit that provides power to the rack. Consult the electrical authority having jurisdiction over wiring and installation requirements - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 12
Component and LED identification Enclosure front components Item 1 2 3 4 5 6 7 8 9 10 Description Device bays* Air intake slot (Do not block.) Power supply bay 1 Power supply bay 2 Power supply bay 3 Power supply bay 4 Insight Display Power supply bay 5 Power supply bay 6 Air intake slot (Do not - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 13
Power supply bay numbering Power supply LEDs Power LED 1 (green) Off On Off Fault LED 2 (amber) Off Off On Condition No AC power to the power supply Normal Power supply failure For power supply configuration information, see Installing a power supply (on page 29). Component and LED - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 14
bay numbering Each enclosure requires interconnects to provide network access for data transfer. Interconnects reside in bays located on the rear of the enclosure. Be sure to review device bay numbering to determine which external network connections on the interconnects are active. IMPORTANT: When - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 15
number and precise U location of the servers. This information is communicated through SIM, ICPM, and HP iPDUs. For LDS software requirements, see the QuickSpecs on the HP website (http://www.hp.com/go/rackandpower). This feature is only available on HP BladeSystem c7000 Platinum Enclosures - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 16
location of the contacts on the c7000 enclosure that enable use of LDS. Enclosure rear components Item 1 2 3 4 5 6 7 8 9 Description Fan bay 1 Fan bay 2 Fan bay 3 Fan bay 4 Fan bay 5 Interconnect bay 2 Interconnect bay 4 Interconnect bay 6 Interconnect bay 8 Component and LED identification 16 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 17
21 22 Description Onboard Administrator bay 2 Power supply exhaust vent (do not block) Fan bay 10 Fan bay 9 Fan bay 8 Fan bay 7 Fan bay 6 AC power connectors Onboard Administrator bay 1 Interconnect bay 7 Interconnect bay 5 Interconnect bay 3 Interconnect bay 1 Fan bay numbering Component and LED - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 18
green Solid amber Flashing amber Fan status The fan is working. The fan has failed. See the Insight Display screen. Onboard Administrator components Item 1 2 3 4 Description Onboard Administrator bay 1 Onboard Administrator bay 2 (redundant, if used) Enclosure link-up port Enclosure link-down - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 19
Reset button - OA/iLO management port Ethernet 100BaseT RJ45 connector, which provides Ethernet access to the Onboard Administrator and the iLO on each blade. Also supports interconnect modules with management processors configured to use the enclosure management network. Also supports GbE. UID - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 20
access the KVM menu or Onboard Administrator CLI, connect a VGA monitor or rack KVM monitor for enclosure KVM. Interconnect bay numbering To support network connections for specific signals, install the interconnect module into the appropriate bay. Server blade signal NICs 1, 2, 3, and 4 (embedded - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 21
6. Connect the AC power cables and power up the enclosure ("Powering up the enclosure" on page 59). 7. Configure the enclosure ("Running the Insight Display installation steps" on page 65) using the Insight Display. Disassembling the enclosure Before installing the enclosure into the rack, you must - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 22
1. With the enclosure still on the pallet, remove all components from the front and rear of the enclosure. 2. Remove the rear cage: a. Loosen the thumbscrews and open the hinges completely. Installation 22 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 23
: When removing and lifting the rear cage, always grasp the handholds as far forward as possible. The front end of the rear cage is heavy and the handholds provide a more balanced location to distribute the weight of the damage. Use caution to avoid damage to the pins and connectors. Installation 23 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 24
Up to four 10U enclosures can be installed in a 42U rack. If you are installing more than one enclosure, install the first enclosure in the bottom of the rack, and then install additional enclosures by moving up the rack with each subsequent enclosure. Plan rack installation carefully because it is - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 25
. 3. Install the rack rails ("Installing the rack rails" on page 25) for each enclosure. 4. Install the enclosure into the rack ("Installing the enclosure into the rack" on page 26). Measuring with the rack template The rack template ships with the rack rail kit and provides detailed instructions on - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 26
two people support the weight of the enclosure. To install the enclosure into the rack: 1. At the front of the rack, lift and align the enclosure guiding fins with the guiding groove in the rack rails. IMPORTANT: Be sure that the guiding fins on the enclosure seat properly in the guiding groove on - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 27
enclosure to the rack. 4. Install the rear cage into the enclosure. ("Installing the rear cage into the enclosure" on page 28) 5. Repeat the procedure for the remaining enclosures. NOTE: Up to four 10U enclosures can be installed in a 42U rack. If you are installing more than one enclosure, install - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 28
hinges completely. 2. Position the rear cage at the rear of the enclosure, and align the rear cage guiding fins with the guiding groove in the rack rails. 3. Slide the rear cage fully into the enclosure. CAUTION: Do not touch or bump rear cage connector pins when installing the rear cage into the - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 29
a power supply See "Running the Insight Display installation steps (on page 65)" for information on the types of power configurations available and how to set them up. If your HP BladeSystem c7000 Enclosure is equipped with a three-phase power configuration, six power supplies are required. Single - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 30
NOTE: This document discusses installation of AC power supplies only. For information on configuring DC power supplies or HP Carrier Grade Solutions, see the documentation that came with your power supply. To install a power supply: 1. Slide the HP BladeSystem Insight Display to the right or left to - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 31
cannot be removed without first removing the upper half-height blade. Installing a full-height blade The HP BladeSystem c7000 Enclosure ships with four device bay shelves to support half-height devices. To install a full-height device, remove the device bay shelf and the corresponding blanks. To - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 32
1. Remove the blank. 2. Remove the three adjacent blanks. 3. Remove the device bay shelf ("Removing a device bay shelf" on page 34). 4. Remove the connector covers. Installation 32 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 33
5. Prepare the blade for installation. 6. Install the blade. CAUTION: To prevent improper cooling and thermal damage, do not operate the blade or the enclosure unless all drive and device bays are populated with either a component or a blank. 7. Install blanks in any empty bays. Installation 33 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 34
Removing a device bay shelf 1. Remove the blank. 2. Slide the device bay shelf locking tab to the left to open it. Installation 34 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 35
plate: o If you are using a device bay blank that came with the enclosure, the coupler plate can be found with the contents of the full-height device shipping box. o If you are using a device bay blank that you purchased as an option, remove the coupler plate from inside the blank. Installation 35 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 36
bottom of the second blank on to the tabs on the coupler plate, and then slide the second blank forward until it snaps in place. 4. Install the full-height blank into the device bay - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 37
Installing a half-height blade 1. Remove the blank. 2. Install the device bay shelf, if applicable. 3. Install the blade in the empty bay. Installing a device bay shelf You must install the device bay shelf to support half-height devices. To install the device bay shelf: Installation 37 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 38
1. Remove the full-height blade, storage blade, or device bay blank. 2. To unlock device bay shelf locking tab, slide it to the left. Installation 38 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 39
tabs on the left edge of the shelf with the openings in the enclosure, and then push the device bay shelf up. CAUTION: Be sure before sliding the shelf forward to complete the installation. Failure to do so can cause damage to server blade connectors during installation. 4. Align the two tabs on the - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 40
USB diskette drive Numerous configurations are possible. This section offers two possible configurations. Accessing a server blade with local KVM For this configuration, a USB hub to the blade. 2. Connect the video connector to a monitor. 3. Connect a USB mouse to one USB connector. Installation 40 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 41
. Use the following configuration when configuring a blade or loading software updates and patches from a USB CD/DVD-ROM or a USB diskette drive. 1. Connect the HP c-Class Blade SUV cable to the blade. 2. Connect the video connector to a monitor. 3. Connect a USB hub to one USB connector. 4. Connect - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 42
drive or diskette drive Installing fans The HP BladeSystem c7000 Enclosure ships with four HP Active Cool 200 Fans and supports up to 10 fans. Install fans in even-numbered groups, based on the total number of blades installed in the enclosure. • Four fan configuration-Fan bays 4, 5, 9, and 10 are - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 43
1. Turn the handle counterclockwise to the unlock position, and pull the fan or fan blank from the enclosure. 2. Slide the fan into the enclosure until it locks in place. NOTE: When installing a fan in the top row of fan bays, orient the fan so that the LED is in the lower right corner. When - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 44
HP BladeSystem c7000 Enclosure is shipped with one HP BladeSystem Onboard Administrator with KVM module installed and can support up to two Onboard Administrator modules. Install Onboard Administrator modules based on the total number ordered: • One Onboard Administrator module: Bay 1 • Two Onboard - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 45
components to the HP c7000 Onboard Administrator with KVM For local access to the enclosure: 1. Connect a monitor (1) to the VGA connector (6) on the HP Onboard Administrator with KVM. 2. Connect a USB hub (4) to the USB connector (5) on the HP Onboard Administrator with KVM. Installation 45 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 46
USB connector (3) on the HP Onboard Administrator with KVM. 2. Connect a CAT5 cable (1) to the KVM interface adapter (2) and an optional HP Console Switch (5). Installing interconnect modules There are eight single-wide interconnect bays in the enclosure. Interconnect bays 1 and 2 are reserved for - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 47
server-specific user guide. To install an interconnect module: 1. Remove the interconnect blank, if applicable. 2. If you are installing a double-wide interconnect module, remove the interconnect bay dividers ("Removing interconnect bay dividers" on page 55). 3. Install the interconnect module, and - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 48
interconnect modules. 4x port mezzanine cards interface with double-wide interconnect modules. The term "1x/2x" refers to the number of interconnect lanes per port provided by the controller. The more lanes provided per port, the higher the data transmission rate coming from that port. Installation - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 49
blades The following table lists the available configurations for half-height devices installed in device bay N (1-16). Connection Port number Embedded NIC Mezzanine slot 1-1x or 2x cards NIC 1 NIC 2 1x/2x port 1 1x/2x port 2 Mezzanine slot 1-4x cards 4x port 1 Connects to interconnect - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 50
One or two double-wide interconnect modules * Connectivity to interconnect bays 7 and 8 is only available with four-port mezzanine cards or port 2 of 4x card in Mezzanine slot 2. Mapping full-height blades The following table lists the available configurations for full-height devices installed - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 51
modules One or two double-wide interconnect modules * Connectivity to interconnect bays 7 and 8 is only available with four-port mezzanine cards or port 2 of 4x card in Mezzanine slot 2. Mapping BL2x220c Blades To support network connections for specific signals, install an interconnect module - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 52
6/Port N 2/Port N 4/Port N 7/Port N 8/Port N Interconnect device mapping for AMC Telco I/O expansion blades The following table lists the available configurations for AMC Telco I/O expansion blades installed in device bay N (1-16). Connection Port number AMC Embedded (1) AMC Embedded (2) Port - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 53
side To support network connections for specific signals, install an interconnect module in the bay corresponding to the embedded NIC or mezzanine signals. Interconnect bay identification Bay-to-bay crosslinks Four trace SerDes signals between adjacent bays are provided in the enclosure midplane to - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 54
PCIe module to a partner blade in the lower adjacent bay and require a PCIe pass-thru mezzanine card installed in mezzanine connector 3. The Onboard Administrator disables the device bay crosslinks when they cannot be used, such as when two server blades reside in adjacent device bays. Interconnect - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 55
tab, and pull the interconnect bay divider out of the enclosure. Installing interconnect bay dividers The enclosure ships with interconnect bay dividers installed. The interconnect bay dividers must be installed to use single-wide interconnect modules. To reinstall an interconnect bay divider, align - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 56
any power components. To cable the system: 1. Connect the Onboard Administrator modules. 2. Connect the network cables to the interconnect modules. See the documentation that ships with the interconnect modules, or the HP ProLiant BladeSystem c-Class Site Planning Guide on the Documentation CD - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 57
HP Intelligent Power Distribution Unit User Guide on the HP website (http://www.hp.com/support/manuals). Enclosure link cabling Two enclosure link ports are provided on the rear of the enclosure. Link multiple enclosures installed in one rack to: • Allow any active Onboard Administrator module to - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 58
the service port. 1. Use the Insight Display on the enclosure you are logging into to obtain the Service IP address of that active Onboard Administrator module on the Enclosure Info screen. The Service IP address can be found in the Enclosure Settings screen. Cabling and powering up the enclosure 58 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 59
Service IP address found in the Enclosure Info screen in step 2. 4. Log into the Onboard Administrator. For more information on using Onboard Administrator, see the HP BladeSystem Onboard Administrator User Guide. Cabling the network to the enclosure Cable the interconnect modules to the enclosure - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 60
Single-Phase Intelligent Power Module To cable the enclosure using a single-phase AC configuration: 1. Connect the AC power cables to the power connectors on the rear of the enclosure corresponding to the power supply that was populated on the front of the enclosure. 2. Be sure each power cable is - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 61
up to 5 minutes before all blades are initialized and recognized by the Onboard Administrator. The time it takes to complete initialization depends on the number of blades configured in the enclosure. For example, a full enclosure of 16 blades might take 5 Cabling and powering up the enclosure 61 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 62
Onboard Administrator programs the mezzanine cards on the blades during discovery. After the mezzanine cards are programmed, powering up the enclosure takes only 1 to 2 minutes. The enclosure and the Insight Display now have power. Configure the enclosure ("Running the Insight Display installation - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 63
2. Connect the AC power cables to the installed PDU. 3. Power up the enclosure ("Powering up the enclosure" on page 59). Cabling and powering up the enclosure 63 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 64
Onboard Administrator programs the mezzanine cards on the blades during discovery. After the mezzanine cards are programmed, powering up the enclosure takes only 1 to 2 minutes. The enclosure and the Insight Display now have power. Configure the enclosure ("Running the Insight Display installation - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 65
on driver and firmware updates, see the HP website (http://www.hp.com/go/blades/). Running the Insight Display installation steps To identify the enclosure, the rear enclosure UID light and the background of the Insight Display are illuminated blue when the enclosure is powered on initially. When - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 66
All, and press the OK button to accept the current settings. You can change the following options in the Enclosure Settings screen: Redundant Power Mode-The default setting is AC Redundant. The following selections are valid: o AC Redundant o Power Supply Redundant HP BladeSystem Insight Display 66 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 67
are set within this option. OA2 IP Addr-If this module is present, the default setting is DHCP. If no IP address is received, the IP address is 0.0.0.0. If only one Onboard Administrator module is installed, the screen will display Not Present. Enclosure Name-The default setting is a unique factory - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 68
configuring the current enclosure only. The Insight Display installation wizard must be run on each of the other detected enclosures. Select this option if each enclosure requires different power settings. IMPORTANT: If your facility uses Static IP addressing for the Onboard Administrator modules - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 69
active Onboard Administrator module using the Onboard Administrator IP address that was configured during the Insight Display installation wizard process. 12. Enter the user name and password from the tag supplied with the Onboard Administrator module to access the remote Onboard Administrator web - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 70
("Running the Insight Display installation steps" on page 65) • Enclosure Info ("Enclosure Info screen" on page 73) • Blade or Port Info ("Blade and Port Info screen" on page 74) • Turn Enclosure UID on/off ("Turn Enclosure UID On/Off screen" on page 75) • View User Note ("View User Note screen - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 71
The only option active on the navigation bar is Back to Main Menu. Select Back to Main Menu, and press the OK button to return to the main menu. If there is a configuration error between the blade and the interconnect module, the error will be highlighted in yellow. HP BladeSystem Insight Display 71 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 72
Select View Alert and press the OK button to display the errors. Select Details to view the details of the error. In the following example, the blade in bay 5 and the interconnect module in slot 3 have a configuration error. HP BladeSystem Insight Display 72 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 73
Enclosure Info screen displays information about the enclosure, including: • Active OA IP address • Active OA Service IP address • Current health status of the enclosure • Current enclosure ambient temperature • Current AC input power to the enclosure • Enclosure name HP BladeSystem Insight Display - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 74
Info screen displays information about a specific blade. On the first screen, select the blade number, then press the OK button. Select Blade Info or Port Info, and press the OK button. To view information about the blade, select Blade Info and press the OK button. HP BladeSystem Insight Display 74 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 75
the technology of the interconnect module. Therefore an error displays. Turn Enclosure UID On/Off screen The main menu option displays "Turn Enclosure UID Off" when the enclosure UID is active, and displays "Turn Enclosure UID on" when the enclosure UID is off. HP BladeSystem Insight Display 75 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 76
changes the color of the Insight Display screen to blue. Selecting Turn Enclosure UID Off from the main menu turns off the rear enclosure UID LED and changes the color of the Insight Display screen to the current condition ("Insight Display overview" on page 65). HP BladeSystem Insight Display 76 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 77
View User Note screen The View User Note screen displays six lines of text, each containing a maximum of 16 characters. Use this screen to display helpful information such as contact phone numbers or other important information. Change this screen using the remote Onboard Administrator user web - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 78
HP BladeSystem c-Class enclosures. This guide explains how to use the Insight Display to troubleshoot enclosures, and it includes a flowchart to help you navigate the troubleshooting process. To view the guide, see the HP website (http://www.hp.com/support/BladeSystem_Enclosure_TSG_en). Important - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 79
installations. • Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason. WARNING: To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 80
. To clear errors that occur after initial powerup and configuration, see the HP BladeSystem Onboard Administrator User Guide for information. The following types of errors can occur when installing and configuring the enclosure: • Power errors (on page 80) • Cooling errors (on page 81) • Location - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 81
user guide on the Documentation CD. Device failure errors Device failure errors occur when a component has failed. Device failure errors can occur on all components, including: • Server blades • Storage blades • Power supplies • Interconnect modules • Onboard Administrator modules Troubleshooting - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 82
Insight Display. In most cases, you must remove the failed component to clear the error. 3. Replace the failed component with a spare, if applicable. NOTE: If the device failure error is an AC power input failure error, you must have the failed AC input repaired to clear the error. Troubleshooting - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 83
HP BladeSystem products only) For more information on obtaining the Onboard Administrator SHOW ALL report, see the HP website (http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c 02843807). • Technical support registration number (if applicable) • Product serial - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 84
costs of this service. • Optional-Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, however, you require required, you can call the HP Technical Support le Centre d'assistance technique HP. Dans les documents envoyés avec la pièce de rechange - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 85
Repair-Verfahren optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. Support and other - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 86
Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. se puede solicitar la entrega en el mismo día o en cuatro horas con un coste adicional. Si precisa asistencia técnica, puede llamar al Centro de asistencia técnica - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 87
gebracht, afhankelijk van het type garantieservice voor het product. OPMERKING: Sommige HP onderdelen zijn niet ontwikkeld locatie. Indien assistentie gewenst is, belt u een HP Service Partner om via de telefoon technische ondersteuning te ontvangen. HP do serviço. Support and other resources 87 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 88
da HP, entre em contato com o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP (http://www.hp.com/go/selfrepair). Support and other resources 88 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 89
Support and other resources 89 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 90
Support and other resources 90 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 91
in a residential environment (for example, personal computers). The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user. FCC rating label The FCC rating label on the device shows the - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 92
P. O. Box 692000, Mail Stop 510101 Houston, Texas 77269-2000 • 1281-514-3333 To identify this product, refer to the part, series, or model number found on the product. Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 93
apparatus meets all requirements of the Canadian Interference of this product is valid if powered with the correct product or product family and available (in English only) either within the product documentation or at the following HP website (http://www.hp.eu/certificates) (type the product number - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 94
Japanese notice BSMI notice Korean notice Class A equipment Class B equipment Regulatory compliance notices 94 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 95
or performance of procedures other than those specified herein or in the laser product's installation guide may result in hazardous radiation exposure. To reduce the risk of exposure to hazardous radiation: • Do not try to open the module enclosure. There are no user-serviceable components inside - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 96
The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of the Waste Disposal Act to indicate the recovery marks on the batteries used in sales, giveaway or promotion. Contact a qualified Taiwanese recycler for proper battery disposal. Power cord statement - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 97
Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part. For more information on static electricity or assistance with product installation, contact an authorized - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 98
ESD electrostatic discharge ICPM Insight Control Power Management IEC International Electrotechnical Commission iLO Integrated Lights-Out PDU power distribution unit RETMA Radio Electronics Television Manufacturers Association (rack spacing) SIM Systems Insight Manager TMRA recommended ambient - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 99
USB universal serial bus Acronyms and abbreviations 99 - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 100
feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:[email protected]). Include the document title and part number, version number, or the URL when submitting - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 101
12, 14 components, identification 12, 14 components, installation 29, 45 components, Onboard Administrator 18, 19, 45 configuration errors 81 configuration, fan 42 configurations, power 59 configuring the enclosure with HP BladeSystem Insight Display 65 contacting HP 83 cooling errors 81 creating - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 102
75 Insight Display screen, View User Note 77 installation errors 81 installation overview 6, 21 installation, rack 24 installation, rack-free 8, 24 installing fans 42 installing interconnect bay dividers 55 installing interconnect modules 46 installing Onboard Administrator modules 44 installing - HP BladeSystem c7000 | HP BladeSystem c7000 Enclosure Setup and Installation Gui - Page 103
, fan bays 17 numbering, full-height device bays 14 numbering, half-height device bays 14 numbering, interconnect bays 53 numbering, power supply bays 13 O Onboard Administrator components 18, 19 Onboard Administrator module 44 Onboard Administrator module, cabling 56 overview of installation
HP BladeSystem c7000 Enclosure
Setup and Installation Guide
Abstract
This guide describes identification, operations, setup, configuration and utilities, troubleshooting, regulatory notices, specifications, and technical
support. This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer equipment, trained in
recognizing hazards in products, and are familiar with weight and stability precautions.
Part Number: 411272-401
February 2013
Edition: 10