HP BladeSystem c7000 User Guide, First Edition - HP StorageWorks Carrier-Grade
HP BladeSystem c7000 Manual
View all HP BladeSystem c7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP BladeSystem c7000 manual content summary:
- HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 1
HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide Part number: 5991-8050 second edition: March 2009 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 2
The information combined herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 3
Contents About this guide 11 Intended audience 11 Prerequisites 11 Related documentation 11 Document conventions and symbols 11 Rack stability 12 HP technical support 12 Customer self repair 12 Product warranties 13 Subscription service 13 HP web sites 13 Documentation feedback 13 1 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 4
port's Ethernet link status LED off 46 Is the power supply's AC Power Good LED off 46 Is the drive enclosure back panel OK LED off 47 Is the drive enclosure Fault/Service Required LED amber 47 Controller failure in a single-controller configuration 48 If the controller has failed or does not - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 5
70 Korean notices 70 Safety 70 Battery replacement notice 70 Taiwan battery recycling notice 71 Power cords 71 Japanese power cord notice 71 Electrostatic discharge 71 Preventing electrostatic damage 71 Grounding methods 72 Index 73 HP StorageWorks 2324fc Modular Smart Array user guide 5 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 6
6 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 7
12-drive enclosure . 23 3 Cabling connections between a dual-controller enclosure and up to three MSA2000 3.5 12-drive enclosures 23 4 MSA2312fc exploded view 54 5 MSA2324fc exploded view 56 6 MSA2000 3.5 12-drive enclosure exploded view 58 HP StorageWorks 2324fc Modular Smart Array user guide 7 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 8
8 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 9
1 Document conventions 11 2 Installation checklist 21 3 Terminal emulator display settings 25 4 Terminal emulator connection settings 25 5 Hard drive LED combinations 32 6 Power supply sensors 51 7 Cooling fan sensor descriptions 51 8 Controller module temperature sensors 51 9 Power supply - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 10
10 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 11
• Network administration • Network installation • Storage system installation and configuration Prerequisites Prerequisites for installing and configuring this product include familiarity with: • Servers and computer networks • Fibre Channel and Ethernet protocols Related documentation In - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 12
feet on the rack. • In multiple-rack installations, secure racks together. • Extend only one rack component at a time. Racks may become unstable if more than one component is extended. HP technical support Telephone numbers for worldwide technical support are listed on the HP support web site: http - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 13
this service provides you with e-mail updates on the latest product enhancements, newest versions of drivers, and firmware documentation updates as well as instant access to numerous other product resources. • After signing up, you can quickly locate your products by selecting Business support and - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 14
14 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 15
FC ports per controller • 1-GB cache module per controller • Battery-free cache backup (with super-capacitor and CompactFlash card) NOTE: Check the QuickSpecs for an updated list of supported operating systems and drives. QuickSpecs can be found from your HP MSA products page at http://www.hp.com/go - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 16
16 Overview - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 17
2 Components Front panel components MSA2324fc 1 23 1 Enclosure ID LED 2 Hard drive Online/Activity LED 3 Hard drive Fault/UID LED 4 5 6 4 Unit Identification (UID) LED 5 Fault ID LED 6 Heartbeat LED HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 17 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 18
panel components MSA2324fc 1 2 3 45 6 7 1 2 1 Power supplies - AC 2 Power switches - AC 3 Host ports 4 CLI port 5 Ethernet port 9 10 8 6 Service port (used by service personnel only) 7 Expansion port 8 Optional FC controller 9 DC Power supply (2) - (DC model only) 10 Power switches - DC 18 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 19
drive enclosure) 6 Optional I/O module NOTE: The MSA2324fc can also be attached to an MSA70 that is running firmware version 2.18 or later. For information about the MSA70, see the HP StorageWorks 70 Modular Smart Array Enclosure user guide located on the MSA2000 Software Support/Documentation CD - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 20
to use this procedure will result in the loss of data stored in the cache module. The CompactFlash must stay with the same enclosure. If the CompactFlash is used/installed in a different enclosure, data loss/data corruption will occur. IMPORTANT: In dual controller configurations, there is no - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 21
are presented. Table 2 Installation checklist Step Task 1. Install the controller enclosure and optional drive enclosures in the rack, and attach ear caps. Where to find procedure See the racking instructions poster. 2. Connect enclosures and drive enclosures. See Connecting controller and - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 22
link for QuickSpecs is on the right. IMPORTANT: The MSA2324fc can also be attached to an MSA70 that is running firmware version 2.18 or later. For information about the MSA70, see the HP StorageWorks 70 Modular Smart Array Enclosure user guide located on the MSA2000 Software Support/Documentation CD - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 23
and one MSA2000 3.5 12-drive enclosure 1A 1B In Out 2A In Out 2B 3A In Out In Out 3B 4A In Out In Out 4B Figure 3 Cabling connections between a dual-controller enclosure and up to three MSA2000 3.5 12-drive enclosures HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 24
for the system to power up. If the enclosure's power-on sequence succeeds as described in Step 1, the system is ready to use. Obtaining IP values NOTE: For help with configuring your MSA2000 product, also see the MSA2000 Software Support/Documentation CD shipped with your product. Setting management - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 25
network administrator configure a terminal emulator, such as HyperTerminal or VT-100, using the display display settings Parameter Value Terminal emulation mode Font VT-100 or ANSI (for color support display the CLI prompt (#). HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 25 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 26
the new IP addresses: show network-parameters Network parameters, including the IP address, subnet mask, and gateway address are displayed for each controller. a. Installing the HP seismic rack mounting kit To install the HP Seismic Rack Mounting kit, follow these steps: 26 Installing the enclosures - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 27
(bottom hole) and the rack, and then loosely attach the bracket to the rear bracket assemblies. 7. Attach the single-hole ground cable lug between the front right mounting ear (top hole) and the rack with a lock washer and screw. HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 27 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 28
Table 5 Callout locations 1 Lock washer 2 Screw 3 Flat washer 4 Bolt 5 Ground cable lug. Position between ear and rail (cable not shown). 28 Installing the enclosures - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 29
assemblies. 9. Attach the loose end of the ground cable to the front rack ground rail. 10. Verify that the MSA2324 CG is evenly spaced between the right and left rack rails, and then tighten the front and rear bracket screws. HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 29 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 30
30 Installing the enclosures - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 31
http://hp.com/support/manuals for the latest MSA2000 supported cable configurations guide. This document is updated whenever newly supported configurations are added. Loop/Point-to-Point Topology The 2324fc Modular Smart Array uses Fibre Channel Arbitrated Loop (loop) topology by default. Point-to - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 32
Two servers/one dual-ported HBA per server/dual path Server 1 Server 2 Connecting switch attach configurations Two servers/two switches Server 1 Server 2 Connecting remote management hosts The management host directly manages systems out-of-band over an Ethernet network. 1. Connect an Ethernet - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 33
time for the upgrade is very important. For software and firmware updates, go to http://www.hp.com/go/msa. Select MSA SAN Arrays, select your product, and go to Support. For detailed steps on updating the firmware, see the reference guide or the CLI reference guide. For information on logging into - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 34
30 Basic operation - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 35
acknowledged but the problem needs attention. Off - No fault condition exists. Green - The enclosure is powered on with at least one power supply operating normally. Off - Both power supplies are off; the system is powered off. HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 31 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 36
Blinking irregularly Off Off On or blinking Amber; blinking regularly (1 Hz) Amber; blinking regularly (1 Hz) Amber; solid Blue; solid Blue; solid alert may have been received for this drive. Further investigation is required. Offline; no activity. A critical fault condition has been identified - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 37
CAUTION: Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is rebuilding. Either there is no power, the drive is offline, or the drive is not configured. HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 33 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 38
5 67 1 2 3 8 9 10 11 LED Description Definition 1 Power supply LEDs See Power supply LEDs. 2 Host Link Status/Activity FC port 1 Blinking green (1 Controller module is not OK. 7 Fault/Service Required Amber - A fault has been detected or a service action is required. Blinking amber - - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 39
restored after the backup power is depleted, the system boots and restores data to cache from Compact Flash, which can take about 90 seconds. The cache flush and self-refresh mechanism is an important data protection feature; essentially four copies of user data are preserved: one in each controller - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 40
7 Definition See Power supply LEDs. Off - Normal operation Blinking white- Physically identifies the expansion module. Green - Port link is up and connected Off - Port is empty or link is down Not implemented Amber - A fault has been detected or a service action is required Blinking amber - Hardware - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 41
the power supplies to separate circuits. 1 1 2 2 AC model LED Description 1 Input Source Power good 2 DC Voltage/Fan Fault/Service Required DC model Definition Green - Power is on and input voltage is normal. Off - Power is off or input voltage is below the minimum threshold. Amber - DC - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 42
38 LED descriptions - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 43
and default password !manage. If you are logging in to the SMU for the first time and no language packages have been installed, the Language field displays user setting or English, either of which when selected results in English. See the reference guide for information on configuring languages - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 44
date and time, which are displayed in the System Status panel. It is important to set the date and time so that entries in system logs and event-notification email messages have correct time stamps. You can set the date and time manually or configure the system to use Network Time Protocol (NTP) to - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 45
to the WBI for installing firmware updates and collecting diagnostic bugs. • Simple Network Mgmt Protocol (SNMP). Used for remote monitoring of the system through your network. • Service Interface. Used for technical support only. • Service Debug. Used for technical support only. In-band management - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 46
will have one volume. You can change the number of volumes and optionally change the default size and base name for the volumes. To postpone creating volumes, you can change the number of volumes to zero. • The default mapping allows no access to the volume by all hosts. Testing the configuration To - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 47
internal data path or an external data path? Is the fault related to a hardware component such as a drive module, controller module, or power supply? By isolating the fault to one of the components within the storage system, you will be able to determine the necessary action more rapidly. Determine - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 48
has failed. and that the enclosure is powered on. • Check the event log for specific information regarding the failure. Is the controller back panel Fault/Service Required LED amber? Answer No Yes (blinking) Possible Reasons System functioning properly. One of the following errors occurred - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 49
not configured. Actions • Check that the drive is fully inserted and latched in place, and that the enclosure is powered on. Is the drive module Fault/UID LED blinking amber? Answer No, but the Online/Activity LED is blinking. Possible Reasons The drive is rebuilding. Actions No action required - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 50
Yes Possible Reasons System functioning properly. The link is down. Actions No action required. Use standard networking troubleshooting procedures to isolate faults on the network. Is the power supply's AC Power Good LED off? Answer No Yes Possible Reasons Actions System functioning properly - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 51
Check that the AC cord is connected to the power supply. Is the drive enclosure Fault/Service Required LED amber? Answer No Yes (blinking) Yes Possible Reasons System functioning properly. One of the following errors occurred: • Hardware-controlled power-up error • Cache flush error • Cache self - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 52
instructions, shipped with the replacement controller. Failure to use this procedure will result in the loss of data stored in the cache module. CAUTION: Remove the controller only after the copy process is complete, which is indicated by the Cache Status LED being off. 48 Troubleshooting - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 53
or cannot access the event logs, use the following procedure. This procedure requires scheduled downtime. IMPORTANT: Do not perform more than one step at a time. Changing more than one variable at a time can complicate the troubleshooting process. 1. Halt all I/O to the storage system. 2. Check the - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 54
Check that all of the fans are working by making sure each power supply's DC Voltage/Fan Fault/Service Required LED is off or by using SMU to check for yellow yield icon hardware warnings. (In the Configuration View panel, right click the enclosure and click View > Overview.) 2. Make sure that all - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 55
shut down. Each power supply has one temperature sensor. When a temperature fault is reported, it must be remedied as quickly as possible to avoid system damage. This can be done by warming or cooling the installation location. Table 8 Controller module temperature sensors Description CPU - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 56
amber and an event is logged to the event log. Table 9 Power supply temperature sensors Description Normal operating range Power Supply 1 temperature Power Supply 2 temperature -10-80C -10-80C Power supply module voltage sensors Power supply voltage sensors ensure that an enclosure's power - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 57
on the product warranty. The part is not available for customer self repair. For assistance, contact an HP-authorized service provider. NOTE: For an updated list of customer self repair parts, go to http://www.hp.com/support/. HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 53 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 58
6 5 3 4 1 2 Figure 4 MSA2312fc exploded view Table 11 MSA2312fc parts list Item Description Spares part number 1 SPS-BLANK,HDD 2 Hard drives 481344-001 - 001 481321-001 490092-001 481345-001 CSR Mandatory Optional Mandatory - Mandatory Mandatory Mandatory Mandatory Mandatory Mandatory - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 59
Not shown Power supplies SPS-POWER SUPPLY (AC) SPS-DC DISK ENCL, POWER SUPPLY SPS-RAIL KIT VLS9000 SPS-CABLE KIT (CLI and SAS expansion cables) SPS-CA KIT, DB9 DB9-M to DB9-F (CLI cable) Spares part number - 481320-001 545764-001 457637-001 481322-001 508297-001 CSR Mandatory Optional - Mandatory - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 60
6 5 3 1 4 2 Figure 5 MSA2324fc exploded view Table 12 MSA2324fc parts list Item Description Spares part number 1 SPS-BLANK,HDD 2 Hard drives a) 36-GB 001 490095-001 490092-001 481345-001 CSR Mandatory Optional Mandatory - Mandatory Mandatory Mandatory Mandatory Mandatory Mandatory - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 61
Item Description Spares part number 7 Not shown Not shown Not shown Power supplies a) SPS-POWER SUPPLY b) SPS-DC DISK ENCL, POWER SUPPLY SPS-RAIL KIT VLS9000 Optional - Mandatory Mandatory Mandatory Mandatory Mandatory HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 57 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 62
2 Figure 6 MSA2000 3.5 12-drive enclosure exploded view Table 13 MSA2000 3.5 12-drive enclosure parts list Item Description Spares part number 1 SPS-BLANK,HDD 2 Hard drives 481344 SPS-ENCLOSURE,I/O MODULE 6 SPS-POWER SUPPLY 481321-001 481342-001 481320-001 CSR Mandatory Optional - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 63
this product, see the warranty information website at http://www.hp.com/go/storagewarranty. • To order a replacement part, contact an HP-authorized service provider or see the HP Parts Store online at http://www.hp.com/buy/parts. HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 64
60 Parts catalog - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 65
provide suitable surge protection. • Site wiring must include an earth ground connection to the AC power source. The supply conductors and power distribution boxes (or equivalent metal enclosure) must be grounded at both ends. • Power circuits and associated circuit breakers must provide sufficient - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 66
is recommended for the initial installation and configuration of a controller enclosure. After you configure one or both of the controller modules with an Internet Protocol (IP) address, you then use a remote management host on an Ethernet network to configure, manage, and monitor. 62 Environmental - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 67
must be strong enough to support the combined weight of the rack, controller enclosures, expansion enclosures, and any additional equipment. The site also requires sufficient space for installation, operation, and servicing the enclosures, and also requires sufficient ventilation to allow a free - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 68
Site wiring and power requirements Each enclosure has two power and cooling modules for redundancy. If full redundancy is required, use a separate power source for each module. The AC power supply unit in each power and cooling module is auto-ranging and is automatically configured to an input - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 69
do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part. For more information on static electricity or assistance with product installation, contact an authorized reseller. HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 65 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 70
66 Electrostatic discharge - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 71
installed in a residential environment (i.e., personal computers). The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user . Declaration of conformity for products marked with the FCC logo - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 72
. The product does not emit hazardous light. Laser safety warning WARNING! To reduce the risk of exposure to hazardous radiation: • Do not try to open the laser device enclosure. There are no user-serviceable components inside. • Do not operate controls, make adjustments, or perform procedures to - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 73
located on the surface of the HP supplied laser device. This optional label indicates that the product is classified as a CLASS 1 LASER PRODUCT. This label may appear on the laser device installed in your product. Figure 6-1 Class 1 Laser Product Label International notices and statements Canadian - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 74
injury if the battery is incorrectly replaced or mistreated. Replacement is to be done by an HP authorized service provider using the HP spare part designated for this product. For more information about battery replacement or proper disposal, contact an HP authorized reseller or HP authorized - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 75
reduce the life expectancy of the device. Preventing electrostatic damage To prevent electrostatic damage, observe the following precautions: • Avoid hand contact by transporting and storing products in static-safe containers. HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 71 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 76
a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an HP authorized reseller install the part. NOTE: For more information on static electricity, or assistance with product installation, contact your - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 77
11 related documentation 11 documentation, HP web site 11 E electromagnetic compatibility (EMC) 61 electrostatic damage prevention 71 enclosure cabling 22 IDs, correcting 44 input frequency requirement 64 input voltage requirement 64 powering on 29 site requirements 63 troubleshooting 43 ESD - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 78
Activity 35 Host Link Status/Activity 34 MSA2000 3.5 12-drive enclosure 36 Fault/Service Required 36 OK 36 OK to Remove 36 SAS In Port Status 36 SAS Out Port Status 36 Unit Locator 36 OK 34 OK to Remove 34 Online/Activity 31 power supply 34 rear panel 34 Unit Identification (UID) 31 Unit - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 79
CompactFlash 19 troubleshooting 43 controller failure, single controller configuration 48 correcting enclosure IDs 44 enclosure does not initialize 43 using system LEDs 44 V ventilation requirements 62 version information checking 29 vibration operating range 63 virtual disks viewing status 42 - HP BladeSystem c7000 | User Guide, First Edition - HP StorageWorks Carrier-Grade - Page 80
W warnings lasers, radiation 68 rack stability 12 voltage and temperature 50 web sites HP documentation 11 HP storage 13 HP Subscriber's choice 13 web-browser configuration 39 work mat, static-dissipating 72 wrist straps specifications 72 using 72 76
HP StorageWorks
Carrier-Grade 2324fc Modular Smart Array
user guide
Part number: 5991-8050
second edition: March 2009