HP Cisco MDS 9124 Cisco MDS 9500 Series Hardware Installation Guide (OL-17467-
HP Cisco MDS 9124 - Fabric Switch Manual
View all HP Cisco MDS 9124 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Cisco MDS 9124 manual content summary:
- HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 1
Send documentation comments to [email protected]. Cisco MDS 9500 Series Hardware Installation Guide October 2008 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 2
and used in accordance with the instruction manual, may cause harmful interference to radio the Way We Work, Live, Play, and Learn and Cisco Store are service marks; and Access Registrar, Aironet, AsyncOS, Bringing the Meeting To You, Guide © 2003-2008 Cisco Systems, Inc. All rights reserved. - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 3
Fabric Manager xix Command-Line Interface xix Intelligent Storage Networking Services Configuration Guides xix Troubleshooting and Reference xix Installation and Configuration Note xix Obtaining Documentation, Obtaining Support, and Security Guidelines xx Product Overview 1-1 Chassis 1-2 Cisco MDS - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 4
Fibre Channel Advanced Services Modules 1-49 32-Port Fibre Channel Storage Services Module 1-50 LEDs on the Storage Services Modules 1-51 Caching Services Module 1-52 LEDs on the Caching Services Module 1-54 Supported Transceivers 1-55 Cisco MDS 9500 Series Hardware Installation Guide ii OL-17467 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 5
and Services Modules 2-45 Installing a Switching or Services Module, Including Caching Services Modules 2-45 Verifying Installation of Supervisor, Switching, and Services Modules 2-46 Removing and Installing a Crossbar Module 2-47 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide iii - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 6
cisco.com. Maintaining a Caching Services Module 2-50 Maintaining the Batteries on the Caching Services Module 2-50 Maintaining the Disk Drives on the Caching Services Module 2-51 Removing and Installing Cisco MDS 9506 Director 2-86 Cisco MDS 9500 Series Hardware Installation Guide iv OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 7
9513 Chassis C-2 Cabinet and Rack Requirements for the Cisco MDS 9509 and Cisco MDS 9506 Chassis C-2 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide v - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 8
the Shelf Bracket Kit into a Four-Post EIA Rack C-10 Installing the Switch on the Rack-Mount Support Brackets C-11 Installing the Switch on the Shelf Brackets C-12 Removing the Shelf Bracket Kit (Optional) C-12 9509 Director D-14 Cisco MDS 9500 Series Hardware Installation Guide vi OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 9
D-34 Cisco DWDM SFP Transceivers D-34 E A P P E N D I X Cable and Port Specifications E-1 Cables and Adapters Provided E-1 Console Port E-2 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide vii - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 10
1900-W AC Power Supplies E-9 Supported Plugs for the 4000-W AC Power Supply E-11 Jumper Power Cord E-11 Power Supply AC Power Cords E-12 AC Power Cord Illustrations E-13 F A P P E N D I X Site Planning and Maintenance Records F-1 Contacting Customer Service F-1 Finding the Chassis Serial Number - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 11
. New and Changed Information This Cisco MDS 9500 Series Hardware Installation Guide applies to Cisco MDS NX-OS Release 4.1(1b) and earlier Cisco MDS SAN-OS releases. Table 1 lists the new and changed features available with each supported Cisco MDS NX-OS release and SAN-OS release for the Cisco - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 12
MDS 9500 Series to support Generation 3 8-Gbps DS-13SLT-FAB2 support 4.1(1b) "Technical module Added information on IPV6 support. 3.3(1a) Product Overview on SAN extension 3.3(1a) support. The "18/4-Port and slots 9 to 13 are reserved for switching, services, and IPS modules, and slots 7 and 8 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 13
Specifications" section on page D-1. Crossbar modules Added crossbar modules. The Cisco MDS 9513 Director supports two crossbar modules located at the rear of the chassis. Each Supervisor-2 module has an section on page D-22. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide xi - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 14
transceiver Added Gigabit Ethernet SFP transceiver. Not release specific The "Supported Transceivers" section on page 1-55 and the "SFP and multiprotocol module. 2.0(1b) The "14/2-Port Multiprotocol Services Module" section on page 1-44. Clock module Added Installation Guide xii OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 15
Where Documented Installation of SFP transceivers Added instructions for installation and removal of SFP Services Modules" section on page 1-46. Cisco MDS Added the Cisco MDS 9506 Director, a 1.1(1a) 9506 Director multilayer Fibre Channel switch that supports up to six modules. This guide - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 16
New and Changed Information Send documentation comments to [email protected]. Cisco MDS 9500 Series Hardware Installation Guide xiv OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 17
preferably be an electronic or electromechanical technician. Organization This guide is organized as follows: Chapter Title Description Chapter 1 Describes the tasks associated with readying the MDS 9500 Series to support Generation 3 8-Gbps Fibre Channel switching modules. Appendix C - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 18
esiintyvien varoitusten käännökset löydät laitteen mukana olevasta Regulatory Compliance and Safety Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta). Cisco MDS 9500 Series Hardware Installation Guide xvi OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 19
Safety Information (Información sobre seguridad y conformidad con las disposiciones reglamentarias) que se acompaña con este dispositivo. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide xvii - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 20
Software Compatibility Information • Cisco MDS 9000 Family Interoperability Support Matrix • Cisco MDS Storage Services Module Interoperability Support Matrix • Cisco MDS NX-OS Release Compatibility Matrix for Storage Service Interface Images Regulatory Compliance and Safety Information • Regulatory - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 21
Storage Networking Services Configuration Guides • Cisco MDS 9000 Family Data Mobility Manager Configuration Guide • Cisco MDS 9000 Family Storage Media Encryption Configuration Guide • Cisco MDS 9000 Family Secure Erase Configuration Guide - For Cisco MDS 9500 and 9200 Series Troubleshooting and - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 22
Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS version 2.0. Cisco MDS 9500 Series Hardware Installation Guide xx OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 23
• Optional hot-swappable switching or services modules. • Switching module port interfaces that support field-replaceable, hot-swappable, form 9000 Family CLI Configuration Guide and the Cisco MDS 9000 Family Fabric Manager Configuration Guide. The Cisco MDS 9500 Series supports the following hot- - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 24
25 • Cisco MDS 9000 Series Module Compatibility, page 1-27 • Port Index Availability, page 1-28 • Switching Modules, page 1-32 • Services Modules, page 1-41 • Supported Transceivers, page 1-55 Chassis This section describes the different chassis offerings in the Cisco MDS 9500 Series: • Cisco MDS - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 25
slots 9 to 13 are reserved for switching and services modules only, and slots 7 and 8 are supports the following: • Two Supervisor-2 modules that reside in slots 7 and 8. • Switching and storage services support the Advanced Services Module (ASM) or the Caching Services Module (CSM). - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 26
Cisco MDS 9513 Chassis Front Panel View 1 2 3 144465 4 1 Switching or services modules in slots 1-6 2 Supervisor-2 modules in slots 7 and 8 3 Switching or services modules in slots 9-13 4 Fan tray The rear of the chassis supports two vertical, redundant power supplies, two clock modules, two - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 27
the air vent panel. You must remove the air vent panel to access the clock modules. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-5 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 28
has a 9-slot chassis as shown in Figure 1-3, and it supports the following: • Redundant Supervisor-2 modules with associated internal crossbar modules MDS 9509 Chassis 1 2 3 4 5 6 78 1 Switching or services modules in slots 1-4 2 Supervisor module in slot 5 3 Redundant supervisor module in - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 29
9506 Director has a 6-slot chassis as shown in Figure 1-4, and it supports the following: • Up to two Supervisor-1 modules that provide a switching fabric Cisco MDS 9506 Chassis 6 4 5 1 2 91580 3 1 Switching or services modules in slots 1-4 2 Supervisor modules in slots 5 and 6 3 Fan - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 30
continues after initial power on, check that all connections are secure. Normal operation or power supply is turned off. Cisco MDS 9500 Series Hardware Installation Guide 1-8 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 31
features such as virtual SANs (VSANs), quality of service (QoS), and N-port interface virtualization (NPIV). NAT). The Cisco MDS Fibre Channel Bladeswitch for IBM BladeCenter supports up to 16 VSANs per blade switch. Each external port Guide. OL-17467-02 Cisco MDS 9500 Series Hardware Installation - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 32
Chapter 1 Product Overview Send documentation comments to [email protected]. Cisco MDS 9513 Power Supplies The Cisco MDS 9513 Director supports the 6000-W AC power supply (AC input). (See Figure 1-6.) Figure 1-6 Cisco MDS 9513 Power Supply 3 2 1 144466 1 Power supply switch 2 AC - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 33
connections are secure, including the system fan tray. Normal operation or power supply is turned off. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-11 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 34
comments to [email protected]. Cisco MDS 9509 Power Supplies The Cisco MDS 9509 Director supports the following types of power supplies: • 4000-W AC power supply (AC input and Power supply switch 5 Permanent power cable 1-12 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 35
9509 Director 1 2 3 4 5 5 1 AC power connection 2 Power cable 3 Power supply switch 4 Power supply LEDs 5 Captive screws 144986 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-13 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 36
FAN OUTPUT OK OK FAIL 3 2 1 Terminal block cover 2 Power supply LEDs 3 Captive screw 4 Power supply switch 5 Terminal block 1-14 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 37
Send documentation comments to [email protected]. Cisco MDS 9506 Power Supplies The Cisco MDS 9506 Director supports the following types of power supplies: • 1900-W AC power supply (AC input and DC output) • turned off. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-15 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 38
management functions for the Cisco MDS 9500 Series. The Cisco MDS 9500 Series supports two supervisor modules for redundancy. In the event of an internal component failure, the factory installed bootflash is not supported. 1-16 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 39
Supervisor-2 module is installed in a Cisco MDS 9513 Director. The Cisco MDS 9513 Director supports two external crossbar modules located at the rear of the chassis that handle this function. (For • LEDs on the Supervisor-2 Module OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-17 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 40
access fairness. • A nondisruptive restart of a single failing process on the same supervisor. A service running on the Supervisor-2 module keeps track of the high availability policy of each process and issues through this port. 1-18 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 41
[email protected]. • Two USB ports provide a simple interface allowing you to connect to different devices supported by Cisco MDS NX-OS. On the double decker connector, USB port 1 is on the lower Supervisor-2 Module LEDs 144808 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-19 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 42
port. No link or no traffic. CompactFlash Green The external CompactFlash card is being accessed. Off No activity. 1-20 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 43
. Supervisor-1 Modules The Cisco MDS 9509 and 9506 Directors support up to two Supervisor-1 or Supervisor-2 modules that can a single failing process on the same supervisor. A kernel service running on the supervisor module keeps track of the high Series Hardware Installation Guide 1-21 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 44
comments to [email protected]. If the kernel service cannot perform a warm restart of the process, it duplex bandwidth per switching module. The Cisco MDS 9500 Series supports redundant supervisor modules. Upon power up with slots 5 and 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 45
, and fan module. Table 1-5 provides more information about these LEDs. Figure 1-15 Supervisor-1 Module LEDs 144853 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-23 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 46
activity. 1. The System and Pwr Mgmt LEDs on a redundant supervisor module are synchronized to the active supervisor module. 1-24 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 47
documentation comments to [email protected]. Crossbar Modules The Cisco MDS 9513 Director supports two external crossbar modules located at the rear of the chassis. Each Supervisor-2 module 16 Crossbar Module LEDs 181335 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-25 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 48
a fault occurred during the initialization sequence. • An over-temperature condition occurred (a major threshold was exceeded during environmental monitoring). 1-26 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 49
(MSM-18/4) module 18-port Fibre Channel and 4-port Gigabit Ethernet IP X X X X X X Services FIPS (MSFM-18/4) module 14-port Fibre Channel/2-port Gigabit Ethernet Multiprotocol Services (MPS-14/2) module X X X X X X OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-27 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 50
, you should be aware of the maximum port availability your chassis can support. A port index is an internally assigned number that Cisco NX-OS -18/4) 14-port Fibre Channel/2-port Gigabit Ethernet 164 Multiprotocol Services (MPS-14/2) module 32 (with Supervisor-1) 16 (with Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 51
Enter the purge module CLI command to free up reserved port indexes after you remove a module. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-29 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 52
of the modules installed will not boot up because the number of port indexes needed has been exceeded. 1-30 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 53
Fibre Channel/2-port Gigabit Ethernet Multiprotocol Services (MPS-14/2) module 8-port Gigabit Ethernet IP Storage Services module 4-port Gigabit Ethernet IP Storage Services module 48-port 4-Gbps Fibre 48 48 48 48 48 48 48 48 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-31 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 54
on the modules. Modifying the factory-installed bootflash is not supported. For configuration information about the modules, see the Cisco MDS 9000 Family CLI Configuration Guide or the Cisco MDS 9000 Family Fabric Manager Configuration Guide. 1-32 Cisco MDS 9500 Series Hardware Installation - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 55
Channel switching module. The front panel connectors support standard modular SFP and SFP+ transceivers switching module. The front panel connectors support standard modular SFP and SFP+ transceivers switching module. The front panel connectors support standard modular SFP and SFP+ transceivers - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 56
Figure 1-20 shows a 48-port 4-Gbps Fibre Channel switching module. The front panel connectors support standard modular SFP and the speed detection is autosensing. Figure 1-20 48-Port 4-Gbps 2 Link LEDs 3 Fibre Channel ports 1-34 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 57
switching module. The front panel connectors support standard modular SFP and the speed detection Fibre Channel interfaces. Each interface is capable of supporting full line rate operation at 4-Gbps interface switching module. The front panel connectors support standard modular SFP and the speed - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 58
ports simultaneously, and up to 80 Gbps of continuous, aggregate bandwidth. Figure 1-24 shows a 4-port 10-Gbps switching module. The front panel connectors support standard modular X2 interfaces and the speed is fixed at 10 Gbps. Figure 1-24 4-Port 10-Gbps Fibre Channel Switching Module 144473 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 59
module provides more ports at a lower price per port. Figure 1-25 shows a 32-port switching module. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-37 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 60
right) 4 Asset tag 16-Port 2-Gbps Fibre Channel Switching Module The 16-port 2-Gbps switching module supports a sustained data rate of up to 2-Gbps in each direction, on all ports simultaneously. The autosensing right) 4 Asset tag 1-38 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 61
on its front panel when a problem is detected. The front panel on module is downloaded from the supervisor module. Prior to the image download, the card. Note Routine software downloads are not required. The serviced periodically. OL-17467-02 Cisco MDS 9500 Series Hardware Installation - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 62
The Fibre Channel switching modules provide autoconfiguring Fibre Channel ports that support Fibre Channel speeds of 1.0625 Gbps and 2.125 Gbps. For more information about supported port types, see the Cisco MDS 9000 Family CLI Configuration Guide. 1-40 Cisco MDS 9500 Series Hardware Installation - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 63
Gigabit Ethernet ports for FCIP and iSCSI storage services. Individual ports can be configured with hot-swappable . For more information on SME, see the Cisco MDS Storage Media Encryption Guide. The MSM-18/4 supports SAN extension over IP and is compatible with current SAN extension products, such - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 64
Services Modules Chapter 1 Product Overview switches running Cisco MDS SAN-OS Release 3.2(1) or later, or NX-OS Release 4.1(1b) support the MSM-18/4 and the MSFM-18/4 module. Figure 1-27 shows the MSM-18/4 Channel ports 4 Link LEDs 1-42 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 65
Chapter 1 Product Overview Services Modules Send documentation comments to [email protected]. LEDs on the 18/4-Port Multiservice Module Table 1-15 . yellow Flashing A fault condition exists. yellow Off No link. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-43 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 66
the computationally intensive IPsec feature for IP services. The MPS-14/2 modules support FCIP compression to maximize the effective WAN bandwidth Family CLI Configuration Guide or the Cisco MDS Family Fabric Manager Configuration Guide. The Fibre Channel port interfaces support hot-swappable Fibre - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 67
Chapter 1 Product Overview Services Modules Send documentation comments to [email protected]. Figure 1-28 shows an MPS-14/2 module. Figure 1-28 Cisco MDS shut down to prevent permanent damage. 2-Gbps mode. 1-Gbps mode. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-45 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 68
Configuration Guide or the Cisco MDS Family Fabric Manager Configuration Guide. The Fibre Channel port interfaces support hot- See the "Supported Transceivers" section on page 1-55. Figure 1-29 shows an IPS-8 services module. Figure 1-29 Cisco MDS 9000 Family IPS-8 Services Module 2 91694 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 69
LED 2 Gigabit Ethernet ports 3 Link LEDs 4 Asset tag LEDs on IP Storage Services Modules Table 1-17 describes the LEDs for the IPS services modules. Table 1-17 LEDs for the Cisco MDS 9000 Family IPS Module LED Status No link. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-47 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 70
. The port interfaces also support coarse wavelength-division multiplexing ( problem is detected. The front panel on the services module provides basic status information, such as power-on, self-test running, self-test passed, alarm, and ready. The binary image for the services module is downloaded - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 71
[email protected]. Note Software downloads are only necessary when a revision of the code is needed. The supervisor module can force a reset on the services module and controls whether power is condition exists. No link. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-49 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 72
support detects a problem. The services module runs from code stored on its local CompactFlash card. The image for an SSM can be specified using the SSI boot variable. For details on how to specify the SSI boot variable, see the Cisco MDS 9000 Family CLI Configuration Guide. Note Software downloads - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 73
is not serviced periodically. LEDs on the Storage Services Modules Table 1-19 describes the LEDs for the Storage Services Modules. Table 1-19 LEDs for the Cisco MDS 9000 Family Storage Services Modules LED exists. No link. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-51 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 74
without external power. Note The Cisco MDS 9513 does not support the CSM. Figure 1-33 shows the CSM. Figure 1-33 CSM 3 6 91626 DS-X9560-SMXX STATUS BATTERY Cashing Services Module 2 1 NODE 1 STATUS DISK 5 4 NODE 2 . 1-52 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 75
Figure 1-34 CSM, Internal View 4 3 2 1 94038 1 Disk drive 2 2 Disk drive 1 3 Battery 2 4 Battery 1 See the "Installing a Switching or Services Module, Including Caching Services Modules" section on page 2-45 for information about installing the CSM and maintaining the CSM batteries. OL-17467 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 76
a cluster. Orange The module is booting or node is administratively down. Flashing orange Node is in service mode. Red Node failure. Off Node does not have power. Green Battery has sufficient charge to does not have power. 1-54 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 77
Note Switches running Cisco MDS SAN-OS Release 1.x, 2.x, 3.x, or NX-OS Release 4.1(1b) support combination Fibre Channel/Gigabit Ethernet SFP transceivers. The transceivers are field-replaceable and hot-swappable. You on page D-19. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-55 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 78
Supported Transceivers Transceivers The Cisco CWDM SFP transceivers have LC connectors and support Gigabit Ethernet and 1-Gbps/2-Gbps Fibre Channel. They match the 8-port IP Storage services (IPS-4 and IPS-8) modules provide four or eight 1-Gigabit Ethernet ports that support Gigabit Ethernet SFP - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 79
22. DWDM Fibre Channel SFP Transceivers The Cisco DWDM SFP transceivers have LC connectors and support 1-Gbps/2-Gbps Fibre Channel. The DWDM SFP transceivers match the International Telecommunications Union (ITU) on page D-22. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-57 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 80
Supported Transceivers Chapter 1 Product Overview Send documentation comments to [email protected]. 1-58 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 81
, and Services Modules, page 2-38 • Maintaining a Caching Services Module, service the system, read the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family for important safety information. Warning IMPORTANT SAFETY INSTRUCTIONS 1071 SAVE THESE INSTRUCTIONS Warning This unit - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 82
Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030 Warning A readily accessible two-poled disconnect device must be rack-mount kit shipped with the switch Cisco MDS 9500 Series Hardware Installation Guide 2-2 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 83
separately) in addition to the front brackets shipped with the switch For instructions on installing the switch using the rack-mount kit shipped with the is adequate space around the switch to allow for servicing the switch and for adequate airflow (airflow requirements are Installation Guide 2-3 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 84
in-lb - M6 screws: 20 in-lb - 10-32 screws: 20 in-lb - 12-24 screws: 30 in-lb Cisco MDS 9500 Series Hardware Installation Guide 2-4 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 85
processors, or by the plastic panels on the front of the chassis. These handles were not designed to support the weight of the chassis. Statement 5 Caution Use a mechanical lift to lift the MDS 9513 chassis. a grounded rack. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-5 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 86
Support at this URL: http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. Note The switch is thoroughly inspected before shipment. If any damage occurred during transportation or any items are missing, contact your customer service MDS 9500 Series Hardware Installation Guide 2-6 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 87
make moving and positioning the chassis easier and safer. See the "Removing, Installing, and Verifying Supervisor, Switching, and Services Modules" section on page 2-38 for instructions specific to the component. Installing the Cisco MDS 9513 Director in a Rack The 6000-W AC power supplies for the - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 88
to the rail. Figure 2-1 Positioning the Rack-Mount Support Brackets 146035 26.56 in Step 3 Install one rack-mount support bar into the slots located on the rack-mount support brackets. Repeat this for the other support bar. Cisco MDS 9500 Series Hardware Installation Guide 2-8 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 89
Support Bars 3 1 3 146034 1 2 1 2 1 1 Screws 2 Rack-mount support bracket 3 Rack-mount support bar Step 4 Once the support bars are installed, secure the rack-mount support be installed to support the front of the rack-mount support bracket. OL-17467-02 Cisco MDS 9500 Series Hardware - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 90
up onto the rack-mount support brackets. Place the rear of the chassis on the rack-mount support brackets between the front mounting rails. Manually slide the chassis into the to ensure that the switch is adequately supported. 2-10 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 91
com. Figure 2-4 Installing the Cable Management Brackets on the MDS 9513 Chassis 3 4 1 2 146038 1 Screws, 12-24 or 10-32 2 Support bracket 3 Mounting rail 4 Cable guide Installing the Cisco MDS 9509 Director in a Rack Caution If connecting a Cisco MDS 9509 Director to a 110-VAC power system - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 92
the second side rack-mount bracket, ensuring that the side rack-mount brackets are at the same height. 2-12 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 93
slide it until it rests on the crossbar and the side rack-mount brackets (see Figure 2-7). OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-13 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 94
-32 x 3/4-inch screws (see Figure 2-8), using six screws per side. Note Use a minimum of six screws per side to ensure that the switch is adequately supported. 2-14 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 95
Management Bracket on the MDS 9509 Chassis 4 2 99023 3 1 1 Screws, 12-24 or 10-32 3 Mounting rail 2 Front rack-mount bracket (behind 4 Cable guide cable guide) Installing the Cisco MDS 9506 Director in a Rack Table 2-3 lists the items provided in the Cisco MDS 9506 rack-mount kit. The kit - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 96
bracket. Figure 2-9 Installing the Cisco MDS 9506 Chassis in the Rack 2 99021 14 3 1 Screws, 12-24 or 10-32 2 Front rack-mount bracket (behind cable guide) 3 Mounting rail 4 Cable management bracket 2-16 Cisco MDS 9500 Series Hardware Installation - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 97
to prevent injury. Insert the rear of the chassis between the front mounting rails (see Figure 2-9), supporting the switch inside the rack until the next step is complete. If you are installing the optional best practices. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-17 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 98
practices should be followed as closely as possible. Electromagnetic noise problems are not anticipated, but installing a best practice grounding system practices should be followed as much as possible. Electromagnetic noise problems are not anticipated, but installing a best practice grounding - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 99
your chassis does not have the system ground attached, you must install the system ground lug. For installation instructions and location of the chassis system ground pads, see "Establishing the System Ground" section on page 2- . OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-19 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 100
clip directly over the head of the system ground lug screw or to the system ground lug barrel. 2-20 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 101
shielding container. If you plan to return the component to the factory, immediately place it in a static shielding container. Cisco MDS 9500 Series Hardware Installation Guide 2-21 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 102
ground. Required Tools and Equipment To connect the ground system, you need the following tools and materials: • Grounding lug-A two-hole standard barrel lug. Supports up to 6 AWG wire. Supplied as part of accessory kit. • Grounding screws-Two M4 x 8mm (metric) pan-head screws. Supplied as part of - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 103
2-11 shows the system ground location on the front panel of the Cisco MDS 9513 chassis. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-23 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 104
plug Figure 2-12 shows the ESD ground location on the rear panel of the Cisco MDS 9513 chassis. 2-24 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 105
chassis must be the grounding type, and the grounding conductors should connect to protective earth ground at the service equipment. For a Cisco MDS 9509 Director with a DC power supply, a grounding cable must be connected chassis. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-25 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 106
the NEC code for ampacity. Figure 2-14 shows the system ground location on the Cisco MDS 9506 chassis. 2-26 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 107
and connect it to an appropriate grounding point in your site to ensure adequate earth ground. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-27 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 108
backplane when the system is operating. Use caution when servicing. Statement 1034 Caution During this procedure, wear grounding wrist chassis. The Cisco MDS 9509 Director and Cisco MDS 9506 Director support both AC and DC power supplies. The Cisco MDS 9506 Director Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 109
green. • OUTPUT FAIL LED is off. See Table 1-2 on page 1-11 for power supply LED details. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-29 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 110
4 Captive screws 5 Power supply LEDs Figure 2-17 shows a 4000-W AC power supply for the Cisco MDS 9509 Director. 2-30 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 111
PEM for Cisco MDS 9506 Director 94981 12 31 1 Captive screws 2 PEM switch 3 AC power connection OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-31 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 112
Cisco MDS 9500 Series director to your outlet receptacle. See the "Jumper Power Cord" section on page E-11. 2-32 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 113
supply in a Cisco MDS 9509 Director, follow these steps: Step 1 Ensure that all power is off. Locate the circuit breaker on the panel board that services the DC circuit. Switch the circuit breaker to the off position, and then tape the switch handle of the circuit breaker in the off position - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 114
Before performing any of the following procedures, ensure that power is removed from the DC circuit. Statement 1003 2-34 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 115
Ensure that all power to the DC circuit is off by locating the circuit breaker on the panel board that services the DC circuit. Switch the circuit breaker to the off position, and tape the switch handle of the circuit . OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-35 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 116
LAN until the initial switch configuration has been performed. For instructions on configuring the switch, see the Cisco MDS 9000 Family CLI Configuration Guide or the Cisco MDS 9000 Family Fabric Manager Configuration Guide. For instructions on connecting to the console port, see the "Connecting to - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 117
and all supervisor, switching, or services modules, and tighten any loose LED is off. • Supervisor, switching, or services modules: - The System LED on the supervisor reporting a problem. - The Status LED on the switching or services modules customer service representative for a - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 118
technical support. If you purchased this product directly from Cisco Systems, contact Cisco Technical Support at problems occur, see the Cisco MDS 9000 Family Troubleshooting Guide or the Cisco MDS 9000 Family System Messages Reference. If you cannot resolve an issue, contact your customer service - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 119
and 9506 Directors by using the out-of-service module slot command (where slot refers to the see the Cisco MDS 9000 Family CLI Configuration Guide. Fail over to the standby supervisor if the the slot. Place your other hand under the module to support the weight of the module. Do not touch the module - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 120
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Chapter 2 Installing the Cisco MDS 9500 remove the panel. To remove a currently installed module, see the "Removing Other Switching and Services Modules" section on page 2-45. Open both the ejector levers on the new or - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 121
9500 Series Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Send documentation comments to [email protected]. Figure 2-22 Positioning a Module in the Chassis 1 2 3 4 4 5 66 3 94987 4 1 Slot guides 2 EMI Gasket 3 EMI Gasket 4 Ejector level (fully - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 122
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Chapter 2 Installing the Cisco MDS 9500 Series Send documentation comments to mdsfeedback-doc@ gasket and the module above it. (See Figure 2-24.) 2-42 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 123
Verifying Supervisor, Switching, and Services Modules Send documentation comments to , see the Cisco MDS 9000 Family CLI Configuration Guide. If you replaced the supervisor in a switch 1.3(1) or later or NX-OS Release 4.1(1b), download the configuration from the server to the nonvolatile memory of - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 124
[email protected]. Removing a Caching Services Module Note A minimum of two to use, see the Cisco MDS 9000 Family CLI Configuration Guide. Ensure that the backup process has completed by verifying that slot. Place your other hand under the module to support the weight of the module. Do not touch the - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 125
module partially out of the slot. Place your other hand under the module to support the weight of the module. Do not touch the module circuitry. Place the can cause serious burns. Statement 341 To install a switching or services module in the chassis, follow these steps: Step 1 Step 2 Guide 2-45 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 126
SAN-OS Release 1.3(1) or later or NX-OS Release 4.1(1b), download the configuration from the server to the nonvolatile memory of the supervisor. Cisco MDS 9000 Family CLI Configuration Guide. Verifying Installation of Supervisor, Switching, and Services Modules To verify the module installation, - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 127
of modules, see the Cisco MDS 9000 Family CLI Configuration Guide. Removing and Installing a Crossbar Module To remove a crossbar Step 2 Step 3 Shut down the crossbar module by using the out-of-service xbar slot command (where slot refers to the external crossbar module slot number). - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 128
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Chapter 2 Installing the Cisco MDS 9500 Series Send documentation comments to mdsfeedback-doc@ any modules, install at least one Supervisor-2 module. 2-48 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 129
Series Removing, Installing, and Verifying Supervisor, Switching, and Services Modules Send documentation comments to [email protected]. slot. Ensure that you align the sides of the module carrier with the slot guides on each side of the slot. b. Slide the module carefully into the slot - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 130
below the required threshold. If this message is displayed, contact your support provider for assistance. If a battery fails, the CSM must fabric contain the same data, and they continue providing caching services during the replacement period. Caution The CSM batteries are shipped Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 131
Maintaining the Disk Drives on the Caching Services Module You see a message in the system log when a disk drive requires replacement. If you see this message, contact your support provider for assistance. If a disk is functioning. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-51 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 132
147966 Step 4 Cable retention device Loosen all four 6-32 panel fasteners at the corners of the power supply. 2-52 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 133
height, use the lower front handle on the face plate and the other hand underneath the power supply. Assure adequate support with both hands on the unit at the designated support points, and slowly pull the power supply out of the chassis so that the weight of the unit will be fully - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 134
the power switch is in the off (0) position on the power supply you are installing. (See Figure 2-29.) 2-54 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 135
states: • INPUT OK LEDs are green. • FANs OK LED is green. • OUTPUT FAIL LED is off. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-55 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 136
remain empty, install a power supply filler panel over the opening, and tighten the captive screw to 8 in-lb. 2-56 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 137
is installed, remove the filler panel from the power supply bay by loosening the captive screw. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-57 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 138
FAN OUTPUT OK FAIL 3 2 1 AC power connection 2 Power supply LEDs 3 Captive screw 4 Power supply switch 5 Permanent power cable 2-58 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 139
9509 Director 1 2 3 4 5 5 1 AC power connection 2 Power cable 3 Power supply switch 4 Power supply LEDs 5 Captive screws 144986 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-59 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 140
: • INPUT OK LED is green. • FAN OK LED is green. • OUTPUT FAIL LED is off. If the LEDs indicate a power problem, see the Cisco MDS 9000 Family Troubleshooting Guide. If you cannot resolve an issue, contact your customer service representative. 2-60 Cisco MDS 9500 Series Hardware Installation - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 141
Step 2 Step 3 Ensure that all power is off by locating the circuit breaker on the panel board that services the DC circuit. Switch the circuit breaker to the off position, and tape the switch handle of the circuit Statement 1046 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-61 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 142
the Cisco MDS 9509 Director, follow these steps: Step 1 Ensure that all power is off by locating the circuit breaker on the panel board that services the DC circuit. Switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off position. 2-62 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 143
states: • INPUT OK LED is green. • FAN OK LED is green. • Output fail LED is off. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-63 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 144
Cisco MDS 9506 Director Note For instructions on connecting the cables to the captive screws and pull the PEM of the chassis, supporting the PEM from underneath. If the PEM bay is the circuit breaker on the panel board that services the DC circuit. Switch the circuit breaker to Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 145
empty, install a PEM filler panel over the opening and tighten the captive screws to 8 in-lb. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-65 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 146
LED states in the back of the chassis: • INPUT OK LED is green. • FAN OK LED is green. 2-66 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 147
: • If the PEM is AC, press the power switch to off (0). • If the PEM is DC, follow the instructions in the "Removing a DC PEM" section on page 2-64. Loosen the captive screws on the power supply. Grasp both , follow these steps: OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-67 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 148
2 Phillips screwdriver to perform these procedures. Note Because the fan modules are located on the left side of the Cisco MDS 9500 Series, Cisco recommends guiding the cables for the system out of the right side of the chassis. 2-68 Cisco MDS 9500 Series Hardware Installation - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 149
power connector from the backplane. Pull the fan module clear of the chassis. (See Figure 2-36.) OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-69 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 150
the chassis, lift the fan module up slightly to align the top and bottom chassis guides, then push the fan module into the chassis until it seats in the backplane and this occurs, contact your customer service representative for a replacement part. 2-70 Cisco MDS 9500 Series Hardware Installation - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 151
the reseller directly for technical support. If you purchased this product directly from Cisco Systems, contact Cisco Technical Support at this URL: http:// both hands. Take one hand and hold the face of the fan tray while supporting it with the other hand. Pull the fan module clear of the chassis. - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 152
into the chassis. c. Tighten the two captive screws on the crossbar module fan tray to 8 in-lb screws. 2-72 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 153
module into the front chassis cavity so it rests on the chassis, lift the fan module up slightly to align the top and bottom chassis guides, then push the fan module into the chassis until it seats in the backplane and the captive screws make contact with the chassis. OL-17467 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 154
service representative for a replacement part. Note If you purchased this product through a Cisco reseller, contact the reseller directly for technical support lift the fan module up slightly to align the top and bottom chassis guides, then push the fan module into the chassis until it seats in the - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 155
the reseller directly for technical support. If you purchased this product directly from Cisco Systems, contact Cisco Technical Support at this URL: http the Cisco MDS 9000 Family CLI Configuration Guide or the Cisco MDS 9000 Family Fabric Manager Configuration Guide. You can install and remove the - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 156
equipment or the disposable grounding wrist strap included with all upgrade kits, field-replaceable units (FRUs), and spares 2-76 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 157
remove the eight back panel screws from the rear of the Cisco MDS 9513 Director chassis. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-77 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 158
View) Sheet metal side Component side Step 5 Repeat Step 3 and Step 4 to remove any additional clock modules. 144602 2-78 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 159
LEDs are in the following states: • INPUT OK LED is green. • FAN OK LED is green. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-79 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 160
removed. Figure 2-43 Clock Module Location on the Cisco MDS 9509 Director (Rear View) 1 2 120141 Cisco MDS 9509 2-80 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 161
press the power switch to off (0) and remove the power cable. • If the power supply is DC, follow the instructions in the "Providing Power to a DC Power Supply in the Cisco MDS 9509 Director" section on page 2-33. Figure 2-44.) OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-81 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 162
on an antistatic mat or foam. Step 5 Repeat Step 3 and Step 4 to remove any additional clock modules. 120166 2-82 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 163
Description Cisco MDS 9506 clock module M3 x 6-mm Phillips pan-head screws Disposable ESD wrist strap OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-83 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 164
module Caution Always wear an ESD wrist strap when handling modules or coming into contact with internal components. 2-84 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 165
the power switch to off (0). Remove the power cord from the PEM. • If the PEM is DC, follow the instructions in the "Removing a DC PEM" section on page 2-64. Loosen the four captive screws on the top power supply. same position. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 2-85 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 166
the following states: • INPUT OK LED is green. • FAN OK LED is green. • OUTPUT FAIL LED is off. 2-86 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 167
support Generation Overview Cisco MDS NX-OS 4.1(1b) supports the following Generation 3 8-Gbps modules addition, Cisco MDS NX-OS 4.1(1b) supports two fabric modules, which are also known the MDS 9513 Fabric 2 modules to support the MDS 9000 48-port 8-Gbps to support the MDS 9000 4/44 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 168
modules in an MDS 9513 Director, be aware of the following usage guidelines: • Cisco SAN-OS release 3.x supports the MDS 9513 Fabric 2 module. • Until you upgrade to Cisco NX-OS 4.1(1b) and reload the switch NX-OS module 4.1(1b) Cisco MDS 9500 Series Hardware Installation Guide A-2 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 169
follow present three procedures for readying an MDS 9513 Director to support the Generation 3 8-Gbps modules. Before you begin one of Optimized module. This procedure offers the following benefits: • There is no service disruption. The upgrade to Cisco NX-OS 4.1(1b) is nondisruptive. • Guide A-3 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 170
). Refer to the upgrade procedure described in the MDS 9000 Family CLI Configuration Guide. Verify that the switch is running Cisco NX-OS 4.1(1b) by entering # show version Cisco Nexus Operating System (NX-OS) Software TAC support: http://www.cisco.com/tac Copyright (c) 2002-2008, Cisco Systems - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 171
Cisco MDS 9000 Family CLI Configuration Guide or Cisco MDS 9000 Family Fabric Manager Configuration Guide for information on how to configure , shut down the standby supervisor and fabric module by entering the out-of-service xbar 1 command. The following example shows the output of the show module - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 172
switch# out-of-service xbar 1 Enter the show module xbar command to verify that the standby supervisor module is powered down. Attach a ESD wrist strap according to the instructions in the section " touch the module circuitry. Cisco MDS 9500 Series Hardware Installation Guide A-6 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 173
the module in the empty slot. Ensure that you align the sides of the module carrier with the slot guides on each side of the slot. b. Slide the module carefully into the slot until the EMI gasket along the module. (See Figure A-2.) OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide A-7 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 174
is seated correctly in the slot. Enter the system switchover command to put the other supervisor in active mode. Cisco MDS 9500 Series Hardware Installation Guide A-8 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 175
15 Enter the show module command to confirm which supervisor module is active. Step 16 Enter the out-of-service xbar slot command (where slot refers to the external fabric module slot number) to shut down the standby at one time. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide A-9 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 176
method you choose, follow the instructions in either the "Installing the described in the MDS 9000 Family CLI Configuration Guide. Verify that the switch is running Cisco NX support. The following example shows the output of the show hardware fabric-mode command, which indicates that support - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 177
has been activated. switch# show hardware fabric-mode Fabric mode supports Gen3 and above linecards. switch# Step 10 Refer to the Cisco MDS 9000 Family CLI Configuration Guide or Cisco MDS 9000 Family Fabric Manager Configuration Guide for information on how to configure the MDS 9000 48-port - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 178
supports Gen3 and above linecards. switch# Refer to the Cisco MDS 9000 Family CLI Configuration Guide or Cisco MDS 9000 Family Fabric Manager Configuration Guide Supervisor-1 modules installed, remove the modules according to the instructions in the "Removing Supervisor Modules" section on page 2-39 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 179
6 Step 7 Step 8 Install Supervisor-2 modules according to the instructions in the "Installing Supervisor Modules" section on page 2-40. Refer to Supervisor-2 Modules procedure described in the MDS 9000 Family CLI Configuration Guide. Upgrade to Cisco NX-OS 4.1(1b). Refer to the upgrade procedure - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 180
Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules Migration Procedure for the MDS 9509 Director and MDS 9506 Director Send documentation comments to [email protected]. A-14 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 181
or for in-band management. • Gigabit Ethernet ports (IP services modules)-Gigabit Ethernet ports that you can use for iSCSI and/ Supervisor-2 module)-A simple interface that allows you to connect to different devices supported by Cisco MDS SAN-OS and NX-OS. On the double-decker Installation Guide B-1 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 182
the IP address and other initial configuration settings before connecting the switch to the network for the first time. Cisco MDS 9500 Series Hardware Installation Guide B-2 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 183
9500 from the CLI. • Monitor network statistics and errors. • Configure SNMP agent parameters. • Download software updates. Note To connect the console port to a computer terminal, the computer must support VT100 terminal emulation. The terminal emulation software-frequently an application such as - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 184
) at the computer serial port. Note For configuration instructions, see the Cisco MDS 9000 Family CLI Configuration Guide or the Cisco MDS 9000 Family Fabric Manager Configuration Guide. Connecting to the COM1 Port Note The COM1 port is not supported for connection to a console. The COM1 port - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 185
. c. Connect the adapters using the RJ-45 to RJ-45 rollover cable (or equivalent crossover cable). OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide B-5 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 186
Ethernet port to the network until the initial configuration is complete. For more information, see the Cisco MDS 9000 Family CLI Configuration Guide. The Supervisor-2 module supports an autosensing MGMT 10/100/1000 Ethernet port (labeled "MGMT 10/100/1000") and has an RJ-45 interface. (See Figure - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 187
port to the network until the initial configuration is complete. For more information, see the Cisco MDS 9000 Family CLI Configuration Guide. The Supervisor-1 module supports an autosensing MGMT 10/100 Ethernet port (labeled "MGMT 10/100") and has an RJ-45 interface. (See Figure B-4.) You can - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 188
supervisor module takes over this IP address. This process requires an Ethernet connection to the newly activated supervisor module. Cisco MDS 9500 Series Hardware Installation Guide B-8 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 189
see the Cisco MDS 9000 Family CLI Configuration Guide. The Cisco MDS 9000 Family supports both Fibre Channel and Gigabit Ethernet protocols for that the X2 transceiver meets the requirements for the switch. For instructions specific to the transceiver type, see the "X2 Transceiver Specifications" - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 190
Send documentation comments to [email protected]. The Cisco MDS 9000 Family supports X2 transceivers with SC connectors. (See Figure B-5.) Figure B-5 Cisco MDS 9000 ) 8 Latching sleeve (extended) 9 Latch (retracted) B-10 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 191
X2 transceiver, follow these steps: Step 1 Step 2 Attach an ESD-preventive wrist strap and follow its instructions for use. If a cable is installed in the transceiver: a. Record the cable and port connections for the transceiver. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide B-11 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 192
Specifications" section on page D-22. The Cisco MDS 9000 Family supports SFP transceivers with the following two types of latching devices: • Step 1 Step 2 Attach an ESD-preventive wrist strap and follow its instructions for use. If a cable is installed in the transceiver: a. Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 193
factory. If another transceiver is not being installed, protect the optical cage by inserting a clean cover. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide B-13 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 194
1 Step 2 Step 3 Step 4 Attach an ESD-preventive wrist strap and follow its instructions for use. Remove the dust cover from the port cage. Remove the dust cover from -preventive wrist strap and follow its instructions for use. B-14 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 195
not install easily, ensure that it is correctly oriented before continuing. For instructions on verifying connectivity, see the Cisco MDS 9000 Family CLI Configuration Guide or the Cisco MDS 9000 Family Fabric Manager Configuration Guide. OL-17467-02 Cisco MDS 9500 Series Hardware Installation - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 196
. If damage is suspected, clean and then inspect fiber ends under a microscope to determine if damage has occurred. B-16 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 197
ANSI/EIA-310-D-1992. See the "Requirements Specific to Two-Post Telco Racks" section on page C-6. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide C-1 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 198
chassis: - Cisco MDS 9513 chassis: 24.5 inches (62.2 cm) or 14 RU, height with required rack mount support is 15 RU. • The distance between the rack-mounting rails for four-post EIA racks must be at least Cord" section on page E-11. Cisco MDS 9500 Series Hardware Installation Guide C-2 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 199
Products: Chatsworth Products, Inc. 31425 Agoura Road Westlake Village, CA 91361 Customer Service and Technical Support phone number 800 834-4969 Cabinet: P/N: NF3K-113C-C42 Cabinet description: The floor to enhance cooling. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide C-3 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 200
from Panduit Corporation: Panduit Corporation 17301 South Ridgeland Avenue Tinley Park, IL 60477 Customer Service and Technical Support phone number: 800 777-3300. Cabinet P/N: CN4-1 Cabinet description: Net-Access cabinet, panels. Cisco MDS 9500 Series Hardware Installation Guide C-4 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 201
RU. - Cisco MDS 9506 chassis: 12.25 inches (31.1 cm) or 7 RU. Note The rack-mount support brackets provided with the Cisco MDS 9513 Director require an additional height of 0.75 inches (1.9 cm). They are required during require shelf brackets. Cisco MDS 9500 Series Hardware Installation Guide C-5 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 202
Shelf Bracket Kit into a Four-Post EIA Rack, page C-10 • Installing the Switch on the Rack-Mount Support Brackets, page C-11 • Installing the Switch on the Shelf Brackets, page C-12 • Removing the Shelf Bracket your switch supplier. Cisco MDS 9500 Series Hardware Installation Guide C-6 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 203
15 lb (6.8 kg) Before Installing the Rack-Mount Support Brackets Before installing the rack-mount support brackets for the Cisco MDS 9513 Director, check the 20 Contents of Shelf Bracket Kit Part Description Support rack-mount bracket Rack-mount support brace 12-24 x 3/4-in. Phillips screws - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 204
the following equipment for this installation: • Number 2 Phillips screwdriver • Tape measure and level (to ensure shelf brackets are level) Cisco MDS 9500 Series Hardware Installation Guide C-8 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 205
to the rear of the shelf brackets as shown in Figure C-1, using the 10-32 screws. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide C-9 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 206
3 Verify that the shelf brackets are at the same height (using the level or tape measure as desired). C-10 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 207
Support Brackets This section provides general instructions for installing the switch on top of the rack-mount support brackets. For detailed installation instructions install, replace, or service this equipment. Statement 1030 Note Before you install, operate, or service the system, see Guide C-11 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 208
instructions for installing the switch on top of the shelf brackets. For detailed installation instructions service this equipment. Statement 1030 Note Before you install, operate, or service to the rack-mounting rails. For additional support in an EIA rack, ensure that the Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 209
your switch supplier. The optional Cisco MDS 9500 Shelf Bracket Kit (DS-SHELF-9500) can be used to support the Cisco MDS 9509 Director in a nonthreaded cabinet or rack with an 18-inch (45.7 cm) front to Shelf Brackets, page C-16 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide C-13 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 210
following equipment for this installation: • Number 2 Phillips screwdriver • Tape measure and level (to ensure shelf brackets are level) C-14 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 211
the shelf brackets are at the same height (using the level or tape measure as desired). OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide C-15 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 212
Switch on the Shelf Brackets This section provides general instructions for installing the Cisco MDS 9509 Director on top to install, replace, or service this equipment. Statement 1030 Note Before you install, operate, or service the system, see the Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 213
are provided in Appendix E, "Cable and Port Specifications." Switch Specifications The Cisco MDS 9500 Series supports hot-swappable fan modules that provide 85 cfm (cubic feet per minute) of airflow per slot Noise levels 70 dB OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-1 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 214
through system fan module, or 90 cfm4 per supervisor, switching, or services module. Total of 1150 cfm if all slots are filled. Spacing requirements: 47.8 cm) Chassis requires 14 RU1 plus space for shelf brackets. Chassis depth including cable guide is 21.64 in. (55.0 cm). Chassis only: 55 lb (24.9 kg) - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 215
300 lfm2 through system fan module, or 80 cfm3 per supervisor, switching, or services module. Total of 720 cfm if all slots are filled. Spacing requirements: • x 44.1 x 55.2 cm). Chassis requires 7 RU1. Chassis depth including cable guides is 26.75 inches (67.9 cm). Chassis only: 46 lb (20.9 kg). - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 216
DC input Airflow 300 lfm2 through system fan module, or 80 cfm3 per supervisor, switching, or services module (total of 480 cfm if all slots are filled). Spacing requirements: • If installed in operation Physical Characteristics Cisco MDS 9500 Series Hardware Installation Guide D-4 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 217
) 8.5 lb (3.86 kg) 8.5 lb (3.86 kg) 10 lb (4.5 kg) 7.25 lb (kg) 9 lb (4.1 kg) 9 lb (4.1 kg) OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-5 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 218
Cisco MDS 9000 Family caching services module. Note The CSM does not support Cisco SAN-OS Release 3.0(1). Table D-7 Caching Services Module Battery Specifications Attribute Value AC power connection @ 220 VAC = 2900 W output Cisco MDS 9500 Series Hardware Installation Guide D-6 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 219
based on worst-case conditions. Typical numbers are approximately 30 percent below the numbers listed here. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-7 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 220
for the Cisco MDS 9513 Director Table D-10 shows the typical AC power consumption for a Cisco MDS 9513 Director. Cisco MDS 9500 Series Hardware Installation Guide D-8 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 221
Power Supply Type Voltage Specification Autoranging input with power factor corrector. 100 to 240 VAC (±10%). OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-9 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 222
. 50/60 Hz (nominal) (±3% for full range). 4000 W maximum. 3.3 V at 15 A; 5 V at 5 A; 12 V at 12 A; 42 V at 91.2 A D-10 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 223
- 1.33 1.39 240 VAC (amps) 1.09 1.13 1.09 1.15 0.66 0.96 - 0.77 - 0.69 - 0.90 - 0.99 1.04 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-11 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 224
1.90 1.42 4/44-port 8-Gbps Host-Optimized 4.x switching module, DS-X9248-48K9 214 915 2.98 2.23 1.49 1.12 D-12 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 225
281 1279 7.81 6.24 295 1342 8.19 6.56 200 910 5.56 4.44 210 956 5.83 4.67 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-13 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 226
the Cisco MDS 9506 Director, page D-16 • AC Power Consumption for the Cisco MDS 9506 Director, page D-19 D-14 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 227
W maximum (at input of -48 to -60 VDC). Output voltage 3.3 V at 2.5 A; 1.5 V at 15 A; 50 V at 37.4 A. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-15 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 228
- 0.92 - 1.19 - 1.33 1.39 240 VAC (amps) 0.66 0.66 1.09 1.15 0.66 0.96 - 0.77 - 0.69 - 0.90 - 0.99 1.04 D-16 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 229
Current Dissipation (BTU/hr) 48 VDC (amps) 573 3.50 573 3.50 60 VDC (amps) 2.80 2.80 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-17 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 230
8.19 6.56 281 1279 7.81 6.24 295 1342 8.19 6.56 200 910 5.56 4.44 210 955 5.83 4.66 D-18 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 231
standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-19 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 232
) Maximum Minimum -1.2 -7.3 0.5 -8.2 4.0 -4.7 Average Receive Power (dBm) Maximum Minimum -1.0 -9.9 0.5 -14.4 -1.0 -15.8 Fiber Loss Budget (dBm) 2.6 (50.0 micron-OM3) 6.2 11.1 D-20 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 233
(984 ft) Note The minimum cable distance for the MMF transceiver listed above is 2 meters (6.5 feet). OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-21 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 234
X2 Transceiver include: • Support for 32 nontunable ITU 100-GHz wavelengths compatible with the Cisco ONS DWDM channel plan. • Support for digital optical monitoring , laser transmit (TX) and laser receive (RX), and support 850 to 1610 nm nominal wavelengths, depending upon the transceiver. - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 235
meets the requirements for the switch. Note Generation 2 modules will not support 1-Gbps/2-Gbps SFPs. Generation 2 modules only support 4-Gbps SFPs. This section provides the following topics: • Cisco Fibre Channel wavelength OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-23 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 236
) Average Receive Power (dBm) Maximum Minimum 0 - Fiber Loss Budget (dBm) 62.5 micron 50.0 s microns [OM2] 50.0 microns [OM3] D-24 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 237
standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-25 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 238
(dBm) Maximum Minimum 0 - -1 - -1.0 - Fiber Loss Budget (dBm) 1.78 (62.5 micron), 2.06 (50 micron OM2), 2.88 (50 micron - OM3) 4.8 7.8 D-26 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 239
.7 Average Receive Power (dBm) Maximum Minimum 0 - -3 - Fiber Loss Budget (dBm) 2.1 (62.5 micron), 2.62 (50 micron -OM2) 7.8 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-27 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 240
Channel-LW SFP, Long wavelength LC 1-Gbps Ethernet and 1-Gbps/2-Gbps Fibre Channel-SW SFP, Short wavelength LC D-28 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 241
.5 micron), 2.62 (FC - 50.0 micron) 2.38 (GE - 62.5 micron), 3.37 (FC - 50.0 micron) 7.8 (FC) 4.57 (GE) OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-29 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 242
SFP 1610 nm; Gigabit Ethernet and 1-Gbps/2-Gbps FC Color Gray Violet Blue Green Yellow Orange Red Brown D-30 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 243
SFP All Cisco 2-Gbps CWDM SFP Transceivers Operating Maximum 40°C Minimum 0°C Storage Maximum 85°C Minimum -40°C OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-31 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 244
, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family. D-32 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 245
, it is necessary to insert an in-line optical attenuator in the link to avoid overloading the receiver. • A maximum of 24 4-Gbps CWDM SFPs are supported in a single MDS switching module. OL-17467-02 Cisco MDS 9500 Series Hardware Installation - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 246
Cisco 4-Gbps CWDM SFP transceiver must be manually configured to 1-Gbps or 2-Gbps. For . Table D-48 lists the transceiver supported on the Cisco MDS 9216. Table DS-SFP-GE-T is not supported on Cisco MDS 9222. General service providers to provide scalable, easy-to-deploy DWDM Fibre Channel services - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 247
com. The main features of the Cisco DWDM SFP include: • Support for International Telecommunication Union (ITU) 100-GHz wavelength grid. • SFP with 32 SFP models. Note A single Cisco MDS 9000 family switching module supports up to eight 2-Gbps DWDM SFPs. For more information, refer to the data - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 248
SFP and SFP+ Transceiver Specifications Appendix D Technical Specifications Send documentation comments to [email protected]. D-36 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 249
cables and adapters can be ordered from your customer service representative. Note If you purchased Cisco support through a Cisco reseller, contact the reseller directly. If you purchased support directly from Cisco Systems, contact Cisco Technical Support at this URL: http://www.cisco.com/warp - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 250
8 1 RJ4-5/DSUB F/F Terminal Adapter DB-25 Pin 5 6 3 7 7 2 20 4 Console Device Signal CTS DSR RxD GND GND TxD DTR RTS Cisco MDS 9500 Series Hardware Installation Guide E-2 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 251
the pinouts for the COM1 port on the Cisco MDS 9500 Series. Note Additional cables and adapters can be ordered from your customer service representative. Table E-4 COM1 Port Pinouts Pin Signal 1 DCD 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS OL-17467-02 Cisco MDS 9500 Series Hardware - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 252
hub, switch, or router (see Figure E-1). Figure E-1 RJ-45 Interface Cable Connector RJ-45 (both ends) 12 1 Pin 1 2 Pin 8 Cisco MDS 9500 Series Hardware Installation Guide E-4 94971 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 253
+ 6 RXD- Switch/Hub 1 RXD+ 2 RXD3 TXD+ 6 TXD- 4 NC 5 NC 7 NC 8 NC 4 NC 5 NC 7 NC 8 NC 99343 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide E-5 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 254
-T Management Port Cable Pinout (MDI) Pin Signal 1 TD+ 2 TD- 3 RD+ 6 RD- 4 Not used 5 Not used 7 Not used 8 Not used Cisco MDS 9500 Series Hardware Installation Guide E-6 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 255
C19 outlet receptacle. Note Only the regular power cords or jumper power cords provided with the switch are supported. Table E-8 lists the power cords for the Cisco MDS 9500 Series switches and provides their lengths in .58 4.14 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide E-7 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 256
Supported Power Cords and Plugs Appendix E Cable and Port Specifications Send documentation comments to [email protected]. Table E-8 Taiwan 13.94 4.25 Cabinet Jumper Power Cord, 250VAC 16A C20-C19 9 2.74 Connectors Cisco MDS 9500 Series Hardware Installation Guide E-8 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 257
Plugs for 6000-W AC, 2500-W AC, and 1900-W AC Power Supplies Figure E-5 shows the supported plugs for the 6000-W AC, 3000-W AC, 2500-W AC, and 1900-W AC power supplies. Figure E-5 NEMA 6-20 plug (20 A) EL 208, SABS 164-1 (16 A) OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide E-9 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 258
supported for the 1900-W AC power supply only. Figure E-6 Additional Power Supply Plug Supported Figure E-7 shows an additional plug that is supported for the 3000-W and 2500-W power supply to the system. Figure E-7 Additional Power Supply Plug Supported for 3000-W and 2500-W 110 VAC Only 113168 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 259
Cords and Plugs Send documentation comments to [email protected]. Supported Plugs for the 4000-W AC Power Supply Figure E-8 shows the supported plugs for the 4000-W AC power supply. The power cable on C20-C19 connectors OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide E-11 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 260
Supported Power Cords and Plugs Appendix E Cable and Port Specifications Send documentation comments to [email protected]. Power Supply AC E-11 Figure E-12 Figure E-13 Figure E-14 Figure E-15 16 A 250 VAC Figure E-16 E-12 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 261
Appendix E Cable and Port Specifications Supported Power Cords and Plugs Send documentation comments to [email protected]. AC Power Cord Illustrations This Length: 14 ft 0 in. (4.26 m) Connector: IEC 60320 C19 113363 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide E-13 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 262
Supported Power Cords and Plugs Appendix E Cable and Port Specifications Send documentation comments to [email protected]. Figure E- Cordset rating: 16 A, 250 V Length: 8 ft 2 in. (2.5 m) Connector: IEC 60320 C19 113364 E-14 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 263
Appendix E Cable and Port Specifications Supported Power Cords and Plugs Send documentation comments to [email protected]. Figure E-15 CAB-9K16A-EU 113348 Plug: CEE 7/7 IEC 60320 C20 Connector: IEC 60320 C19 240902 OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide E-15 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 264
Supported Power Cords and Plugs Appendix E Cable and Port Specifications Send documentation comments to [email protected]. E-16 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 265
MDS 9000 Family Fabric Manager Configuration Guide. Contacting Customer Service If you are unable to solve a startup problem after using the troubleshooting suggestions in this appendix, contact your customer service representative for assistance and further instructions. Before you call, have the - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 266
Contacting Customer Service Appendix F Site Planning and Maintenance Records Send documentation comments to [email protected]. Finding the Chassis Serial have the serial number label on the right side instead of the left. Cisco MDS 9500 Series Hardware Installation Guide F-2 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 267
Appendix F Site Planning and Maintenance Records Contacting Customer Service Send documentation comments to [email protected]. Figure F-2 Serial Number Location on Cisco Director 113872, 781-00275-01A0 OL-17467-02 SN: AAANNNNXXXX Cisco MDS 9500 Series Hardware Installation Guide F-3 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 268
• DC systems: proper gauge wire and lugs 4 Grounding evaluation: • Circuit breaker size • CO ground (AC- and DC-powered systems) Cisco MDS 9500 Series Hardware Installation Guide F-4 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 269
source or DC source circuit. 2. UPS = uninterruptible power supply 3. EMI = electromagnetic interference 4. RFI = radio frequency interference OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide F-5 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 270
Contact e-mail Building/site name Data center location Floor location Address (line 1) Address (line 2) City State Zip code Country Cisco MDS 9500 Series Hardware Installation Guide F-6 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 271
DNS address Modem telephone number Table F-4 Module Information Slot Module Type 1 Module Serial Number 2 3 4 5 Supervisor Notes OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide F-7 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 272
Module Type 6 Supervisor 7 Module Serial Number Notes 8 9 Note Slots 7, 8, and 9 are only available in the Cisco MDS 9509 Director. Cisco MDS 9500 Series Hardware Installation Guide F-8 OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 273
description 1-35 figure 1-35 14/2-port Multiprotocol Services module. See MPS-14/2 16-port switching 33 32-port Fibre Channel Advanced Services Module. See ASM 32-port Fibre Channel Storage Services Module. See SSM 32-port 2-50 binary images downloading 1-48, 1-50 Bladeswitch 1-9 Cisco MDS - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 274
B-2 SFP transceivers B-14, B-15 Caching Services Module. See CSM chassis grounding 2-23 Cisco MDS 9500 Series Hardware Installation Guide description 1-3 features 1-3 figure 1-4, cabling E-3 connecting B-4 pinouts (table) E-3 support B-4 support (note) B-4 CompactFlash cards installing 2-76 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 275
crossbar modules Cisco MDS 9513 support 1-25 description 1-25 installing requirement (note) 2-44 CUP 1-41 customer service, contacting F-1 CWDM transceivers description 1-56 SFP transceiver ) 2-61 documentation additional publications 1-xviii downloading software images ASM-SFN image 1-48 Guide IN-3 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 276
modules 2-48 IN-4 Cisco MDS 9500 Series Hardware Installation Guide EIA shelf brackets C-6 equipment required 2-5 guidelines 2-3 power description 1-46 IPS-8 modules, figure 1-46 LEDs (table) 1-47 IP Storage Services module. See IPS modules IPv6 1-41 L LC-type cables connecting to Fibre Channel - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 277
information (table) 1-ix O open racks, standard (requirements) C-5 organization description 1-xv P PEMs installing 2-64 removing 2-64 physical specifications (table) D-2 pinouts Cisco MDS 9500 Series Hardware Installation Guide IN-5 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 278
2-52 starting up the switch 2-28 supported plugs E-7 IN-6 Cisco MDS 9500 Series Hardware Installation Guide power supplies (Cisco MDS 9506 Director) removing ) 2-56, 2-61 power supplies (MDS 9513 Director) 2-52 services modules 2-45 SFP transceiver cables B-14 SFP transceivers B-12 shelf brackets C- - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 279
(MDS 9509 Director) F-2 location (MDS 9513 Director) figure F-2 services modules ASM 1-48 CSM 1-52 description 1-41 Generation 1 modules 1- supported D-28 Fibre Channel specifications D-23 Fibre Channel supported D-23 Gigabit Ethernet 1-56 installing B-14 latches supported Installation Guide IN-7 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 280
1-22 redundant central arbiter 1-21 support (note) 1-21 warm switchover 10-Gbps Fibre Channel switching modules 1-36 description 1-32 downloading binary image 1-48, 1-50 features 1-39 Generation supported SFP transceivers 1-55 supported X2 transceiver 1-55 troubleshooting contacting customer service - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 281
supported (table) D-20 Numerics 12-port 4-Gbps Fibre Channel switching modules description 36 figure 37 14/2-port Multiprotocol Services Services Module. See ASM 32-port Fibre Channel Storage Services binary images downloading 49, 51 transceivers 14, 15 Caching Services Module. See CSM chassis - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 282
port cabling 3 connecting 4 pinouts (table) 3 support 4 support (note) 4 CompactFlash cards installing 76 LED on description 16 crossbar modules Cisco MDS 9513 support 25 description 25 installing 48 location 25 CUP 42 customer service, contacting 1 CWDM transceivers description 57 IN-10 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 283
documentation additional publications xviii downloading software images ASM-SFN image Generation 1 modules services modules 42 switching brackets 10 rack-mounting guidelines 6 services modules 38 SFP transceiver cables 15 SFP SFP transceivers 14 IP Storage Services module. See IPS modules IPS - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 284
(table) 3 pinouts COM 1 port 3 console port 2 MGMT 10/100 Ethernet port 6 MGMT 10/100/1000 Ethernet port 4 IN-12 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 285
plugs supported for ) 52 starting up the switch 28 supported plugs 7 power supplies (Cisco MDS 9506 supplies (MDS 9513 Director) 52 services modules 45 SFP transceiver cables 14 Director) 2 location (MDS 9513 Director) figure 2 services modules ASM 49 CSM 53 description 42 Generation 1 modules - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 286
LEDs (table) 24 memory options 22 nondisruptive restart 21 processor 22 redundant central arbiter 21 support (note) 21 warm switchover 22 Supervisor-2 Ethernet port 6 Supervisor-2 modules CompactFlash cards 19 CompactFlash 18 IN-14 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02 - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 287
modules 34 4-port 10-Gbps Fibre Channel switching modules 37 description 33 downloading binary image 49, 51 features 40 Generation 1 modules 33 Generation 5 transceivers description 56 supported SFP transceivers 56 supported X2 transceiver 56 troubleshooting contacting customer service 1 W weight of - HP Cisco MDS 9124 | Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 288
Index Send documentation comments to [email protected]. IN-16 Cisco MDS 9500 Series Hardware Installation Guide OL-17467-02
Send documentation comments to [email protected].
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Cisco MDS 9500 Series Hardware
Installation Guide
October 2008
Text Part Number: OL-17467-02