HP D5970A hp lc 2000 and virtual array config guide — for the VA
HP D5970A - NetServer - LCII Manual
![]() |
View all HP D5970A manuals
Add to My Manuals
Save this manual to your list of manuals |
HP D5970A manual content summary:
- HP D5970A | hp lc 2000 and virtual array config guide — for the VA - Page 1
• Client LAN configuration • FC cabling configuration • Supported Fibre Channel topologies • Power distribution configuration Server Configuration Parameter Server Type Number of nodes Clock speed Number of CPUs BIOS CPU cache Specification HP Netserver LC 2000, Ultra2 embedded SCSI models Two Do - HP D5970A | hp lc 2000 and virtual array config guide — for the VA - Page 2
lc2000nt71-74 Server Configuration Parameter RAM Number of power supplies I/O slots Default boot order Local Storage Controller Driver Physical drive location Disk drives SCSI bus SCSI IDs System software Navigator CD-ROM Operating system Service pack HP Surestore Auto Path VA Specification 128 - HP D5970A | hp lc 2000 and virtual array config guide — for the VA - Page 3
GBICs Specification SW optical is supported to the storage enclosure. Any SW (short wavelength) optical cable may be used, including these listed. Optical (server HP Brocade Silkworm 2400 8 Port FC Switch, product number A5625A and A5667A (standalone), or A5625AZ (rack optimized) HP Netserver - HP D5970A | hp lc 2000 and virtual array config guide — for the VA - Page 4
NIC, hptxnt.sys, version 4.02.35, or later (driver obtained from Navigator CD-ROM L.20.00, or later). For other NICs, any vendor-supported driver. Client LAN Configuration Parameter Network Connection NIC Quantity Model Driver Specification Any LAN One HP D5013B or any model that is on both the - HP D5970A | hp lc 2000 and virtual array config guide — for the VA - Page 5
lc2000nt71-74 HP VA 7400 Dual HBA Cluster Public Network Server 1 Private Network Server 2 FC Hub/Switch FC Hub/Switch HOST FC 2* Secondary path for RG 1 Performance note: For best performance, If Server 1 and Server 2 are configured in an active/active cluster configuration, where each is - HP D5970A | hp lc 2000 and virtual array config guide — for the VA - Page 6
F_Port VA7X00 Brocade Switch LC 2000 N_Port N_Port Switched Fabric with Two Switches and Two HBAs N_Port optical fiber or copper cables optical fiber cable Supported Topologies for the HP LC 2000, VA 7400 Cluster 3/11/02 6 - HP D5970A | hp lc 2000 and virtual array config guide — for the VA - Page 7
lc2000nt71-74 Power Cabling to Separate Power Circuits 3/11/02 7 - HP D5970A | hp lc 2000 and virtual array config guide — for the VA - Page 8
Versions 11 March 2002 8 March 2002 lc2000nt71-74 Removed VA 7100. Certification covers only VA 7400. (VA 7100 is supported.) Initial release © Copyright 2002, Hewlett-Packard Company 3/11/02 8
![](/manual_guide/products/hewlettpackard-lh3000r-hp-lc-2000-virtual-array-config-guide-va-7400-microsoft-windows-nt-clusters-pdf-227k-382002-2035306/1.png)
3/11/02
1
HP Netserver LC 2000 with
HP Surestore Virtual Array 7400
Windows NT
°
4.0 Enterprise Edition
Cluster Configuration Guide
Introduction
This document defines the server cluster configurations supported by Hewlett-Packard for interconnection of
two HP Netserver LC 2000 servers and one HP Surestore VA 7400 disk drive enclosure, with Microsoft
Cluster Server software.
These configurations provide high server cluster availability and minimize single
points of failure (SPOFs).
A configuration certified and supported by both Hewlett-Packard and Microsoft
is included, but any cluster configuration that conforms to the guidelines of this document will be supported
by Hewlett-Packard.
Deviations from the supported configurations can result in an inoperative cluster, an
operating cluster with degraded performance, or hidden SPOFs.
Therefore, deviations are not supported.
For
revision/update information on this document, refer to
Versions
on page 8.
Cluster Configuration Elements
This section identifies the hardware components, system software, network interfaces, and power distribution
arrangement required to build an operational server cluster supported by Hewlett-Packard.
The various
server cluster elements are listed below, and their associated configuration data is detailed in separate tables
and illustrations that follow.
•
Server configuration
•
Shared storage configuration
•
Microsoft
and HP certified server configuration
•
Intra-cluster (heartbeat) LAN configuration
•
Client LAN configuration
•
FC cabling configuration
•
Supported Fibre Channel topologies
•
Power distribution configuration
Server Configuration
Parameter
Specification
Server
Type
HP Netserver LC 2000, Ultra2 embedded SCSI models
Number of nodes
Two
Do not mix ultra2 and ultra3 models within a cluster.
Each node must be the
same server type, but nodes may differ in their CPU clock speeds and cache sizes,
and amounts of main memory.
Clock speed
1000 MHz
This certification covers any CPU rate within 500 MHz of the certified speed.
Number of CPUs
Two
BIOS
Version range 4.06.29 PV to 4.06.30 PV
CPU cache
Any size