HP D5970A HP Netserver LC 2000 FC Config Guide

HP D5970A - NetServer - LCII Manual

HP D5970A manual content summary:

  • HP D5970A | HP Netserver LC 2000 FC Config Guide - Page 1
    This document defines supported HP NetServer LC 2000 configurations with HP Rack Storage/12FC and Microsoft Cluster Server. These configurations minimize single points of failure (SPOF, SPOFless1) and provide extended availability. The specific configuration certified and supported by both Hewlett
  • HP D5970A | HP Netserver LC 2000 FC Config Guide - Page 2
    software: Navigator version Operating System Service -1Si Local Controller Driver Cabinets (Physical drive location) Disk drives SCSI bus SCSI drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP (hot swap or fixed) Any HP cables that meet SCSI specifications
  • HP D5970A | HP Netserver LC 2000 FC Config Guide - Page 3
    or later. For SPOFless, use 5.46-04 5 (fixed) 0 - 3, 8 - 15 (fixed) Any HP drive supported by storage enclosure Fibre Channel Cables Hub Model Quantity Optical - Server to Hub Only: 50 meter D6980A 100 meter D6981A Copper - Server to Hub and/or Shared Storage to Hub: 3 meter D6978A 5 meter D6979A
  • HP D5970A | HP Netserver LC 2000 FC Config Guide - Page 4
    . Any LAN Embedded NIC Hptxnt.sys 4.02.30 or later 1 Any that is on both the HP Tested Products List and the Microsoft Hardware Compatibility List. For SPOFless, use D5013A or B. The vendor supported driver. NOTE If the NIC used is the same type as the embedded NIC (D5013A/B), then the Client
  • HP D5970A | HP Netserver LC 2000 FC Config Guide - Page 5
    Heavy (blue) lines are fibre channel Optical or Copper cables. See inside this guide for specifications. Dashed(green) lines are offset SCSI cables. See inside this guide for specifications. HP Microsoft Cluster (SPOF) using HP Rack Storage/12FC and Rack Storage/12 and 6 Port Fibre Channel Hub 5
  • HP D5970A | HP Netserver LC 2000 FC Config Guide - Page 6
    Power Cabling to Separate Power Circuits (SPOF) (For SPOFless with 2 hubs, connect second hub to PDU that first hub is not attached to) 6
  • HP D5970A | HP Netserver LC 2000 FC Config Guide - Page 7
    lines are copper fibre channel. Dashed(green) lines are offset SCSI cables. See inside this guide for specifications. Each copper cable goes to Port 'y' on the RS/12FCarray controllers. HP SPOFless Microsoft Cluster using HP Rack Storage/12FC and Rack Storage/12 and two 6 Port Fibre Channel Hubs 7
  • HP D5970A | HP Netserver LC 2000 FC Config Guide - Page 8
    NIC) HBA in P5 2. The bottom two shared storage devices are SCSI HP Rack Storage/12's and are optional to the cluster configuration. LEGEND Solid red this guide for specifications. Copper cable goes to Port 'y' on the second RS/12FCarray controller. HP SPOFless Microsoft Cluster using HP Rack
  • HP D5970A | HP Netserver LC 2000 FC Config Guide - Page 9
    Versions 22 February 2001 Initial release. 9
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

1
HP NetServer LC 2000
with
HP Rack Storage/12FC
Cluster Configuration Guide
22 February 2001
(see
Versions
at the end of this document)
Introduction
This document defines supported HP NetServer LC 2000 configurations with HP Rack Storage/12FC and
Microsoft Cluster Server.
These configurations minimize single points of failure (SPOF, SPOFless
1
) and
provide extended availability. The specific configuration certified and supported by both Hewlett-Packard
and Microsoft is defined, as are other guidelines to assist you in configuring your clustered NetServers.
This guide is prescriptive; it describes the configurations supported by HP.
Any deviance to these
configurations can result in an inoperative cluster or an operating cluster with degraded performance,
hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LC 2000
Each node must be the same model SPU, but may have different sizes of
main memory, cache, and different CPU clock speeds.
Installation
Pedestal or racked
Number of nodes
2
Shared Storage
HP Rack Storage/12FC with 2 FCArray Cards, HP disks, and using a HP
D8602A HBA in the server.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft approved.
See
Client LAN
below.
1
For more information about configuring a SPOFless cluster, refer to the HP white paper,
High Availability
MSCS Cluster Solution
on the HP NetServers, HA Planning website.