- HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 1
information specific to your cluster configuration that you will need during installation of your cluster. • HP NetServer Microsoft Cluster Installation Guide - This is the first of two documents used to install the cluster. It covers the installation of all cluster supported HP NetServers and - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 2
20 January 2000 Version History Initial release - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 3
Software (Windows NT, NIC drivers, etc.) IP Addresses, subnet Service Pack Install HotFix (Service Pack 3 only) Testing È Run: Hardware Verification and Labeling Utility Cluster Installation Test (CIT) How to do it! (See the referenced part in the Installation Guide) 1 What's Needed 2 NetServers - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 4
This page intentionally left blank. - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 5
Intra-cluster Power source System software: Navigator version Operating System Service pack HP NetServer LC3 Each node must be the same model SPU, but may have different size main memory and cache. 2 HP Rack Storage/12 with HP NetRAID-3Si controller and HP disks. See Shared Storage below. Any - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 6
Storage Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SPU I/O slot SCSI ID Channels RAID level Logical disks Configuration options: HP NetServer LC3 400, 450, 500, 550 MHz. 1 - 2, but must be the same number of CPUs in each server 4.06.23 PQ Any size 64 MB minimum - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 7
. It may not be used for client communication. Client LAN Any LAN HP D5013A/B (10/100TX PCI) 3.27.00.0001 or later 1 P4 Any that is on both the HP Tested Products List and the Microsoft Hardware Compatibility List. Any driver NOTE If the NIC used is the same as the Intra-cluster - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 8
Shared Storage Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer LC3 and HP Rack Storage/12s. Only these cabling configurations and cables are supported. HP Microsoft Cluster using HP Rack Storage/12 4 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 9
Version History 20 January 2000 Initial release. 5 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 10
This page left blank intentionally 6 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 11
HP NetServer Microsoft Cluster Installation Guide with Shared Storage System Supplement Rack Storage/12FC Rack Storage/12 Rack Storage/8 Storage System/6 HP SureStore E 12H Disk Array or HP A3661B Model 30/FC High Availability Disk Array 18 January 2000 (See Version History below) - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 12
This page intentionally left blank. HP NetServer Installation Guide 2 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 13
associated instruction(s). Servicing Any service, adjustment, maintenance, or repair must be performed only by authorized service in this manual: • Microsoft Server Division 10955 Tantau Avenue Cupertino, CA 95014-0770, USA © Copyright 1999, Hewlett-Packard Company HP NetServer Installation Guide - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 14
FILE SYSTEMS...36 7 MICROSOFT CLUSTER SERVER SOFTWARE SETUP 42 INSTALL MSCS ON SYSTEM A...42 INSTALL MSCS ON SYSTEM B...46 INSTALL SERVICE PACK OR HOT FIX ...46 8 CLUSTER TESTING ...47 HARDWARE VERIFICATION AND LABELING UTILITY 47 CLUSTER INSTALLATION TEST...47 HP NetServer Installation Guide 4 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 15
you setup the HP NetServers, set up, assemble and cable the cluster, and install server and cluster software. NOTE This guide is incomplete without the supplement specific to your shared storage system. When directed by this guide, turn to the supplement to get the necessary instructions. Version - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 16
NOTE Hewlett-Packard only supports and recommends installation of clustered HP NetServer systems using Microsoft Cluster Server software by a Microsoft or HP Cluster Certified Installer. HP NetServer Installation Guide 6 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 17
A Graphical Overview to Setting Up the Cluster CAUTION Departing from the sequence shown here can cause unnecessary work and unpredictable results. HP NetServer Installation Guide 7 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 18
. 2. On the site navigator bar, select SEARCH, then search for Q147222 in the "Support & Knowledge Base" category. 3. On the Search Results page, select Group of Hotfixes for Exchange 5.5 and IIS 4.0, then follow the ftp path to download the "clusfixi.exe" file. HP NetServer Installation Guide 8 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 19
Service Grounding Kit (3M® part number 8505, or equivalent). Need More Help? HP Information Assistant provides extensive support information and is available on the HP NetServer Online Documentation CD-ROM. Although you can access HP Information Assistant from the NetServer Navigator Main menu, HP - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 20
to the Shared Storage Systems and must be installed in specific PCI slots. See the Configuration Guide for your cluster configuration for the HP NetServer PCI slots to use. See instructions supplied with the component or see part "2 NetServer Hardware Setup" of the Shared Storage Supplement for - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 21
3 Shared Storage Hardware Setup part "3 Shared Storage Hardware Setup" in the Shared Storage Supplement HP NetServer Installation Guide 11 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 22
instructions in the shared storage supplement. In addition you should have rack layouts of your system printed from the HP NetServers Rack Assistant program. If not, see HP NetServers web site to download called the client LAN. NOTE See the Configuration Guide for your cluster for the PCI slots to - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 23
Service Pack On page ... 13 14 15 16 18 20 22 24 26 28 29 30 32 33 35 LCII Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server. The server boots from the CD - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 24
. When finished, the system reboots and displays the Custom Configuration window. Install Windows NT 8. Remove the HP NetServer Navigator CD, insert the first CD of the Microsoft Windows NT Server, Enterprise Edition, and exit Navigator to reboot the server. HP NetServer Installation Guide 14 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 25
. When finished, the system reboots and displays the Custom Configuration window. Install Windows NT 1. Remove the HP NetServer Navigator CD, insert the first CD of the Microsoft Windows NT Server, Enterprise Edition, and exit Navigator to reboot the server. HP NetServer Installation Guide 15 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 26
driver version as specified in the Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver provide instructions for servers using server to reboot. The server boots from the CD and displays the Navigator Main menu. NOTE If prompted that the HP NetServer Navigator - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 27
1. Remove the HP NetServer Navigator CD, insert the boot floppy for Windows NT4.0, and exit Navigator to reboot the server. 2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: • The drivers are loaded from the NT 4.0 Drivers floppy disk - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 28
the D5013A/B NIC drivers must be manually set to the set to 100 Mbps. Do not use the Auto setting. LH 3 (with NetRAID Local and Shared Storage) A NetRAID adapter server to reboot. The server boots from the CD and displays the Navigator Main menu. NOTE If prompted that the HP NetServer Navigator - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 29
drivers you need. If you are using the embedded SCSI channels, load the Symbios driver at this time. 4. Continue the installation and select the following options when prompted: • Choose the unpartitioned space and install Windows NT. • Choose NTFS file system HP NetServer Installation Guide - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 30
drivers must be manually LH 4 These procedures provide instructions for servers using NetRAID, SureStore E 12H, and Model 30/FC shared storage solutions. Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 31
.0 and exit Navigator to reboot the server. 2. When Windows NT Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: • The drivers are loaded from the NT 4.0 Drivers floppy disk you created from the Navigator CD. • First, load the driver for the - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 32
drivers must be manually LH 4 (Fibre Channel) These procedures provide instructions for servers using the HP Rack Storage/12FC. Configure NetServer Hardware and BIOS 1. System A and System B can both be powered on. 2. Insert the HP NetServer Navigator CD in the CD HP NetServer Installation Guide 22 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 33
.0 and exit Navigator to reboot the server. 2. When Windows NT Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: • The drivers are loaded from the NT 4.0 Drivers floppy disk you created from the Navigator CD. • First, load the driver for the - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 34
the HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. If you have special NetServer local SCSI instructions to create the NetRAID Assistant installation floppy disks. Label the floppy disks HP NetRAID Assistant 1 and HP NetRAID Assistant 2. HP NetServer Installation Guide - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 35
1. Remove the HP NetServer Navigator CD, insert the boot floppy for Windows NT4.0, and exit Navigator to reboot the server. 2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: • The drivers are loaded from the NT 4.0 Drivers floppy disk - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 36
the HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. If you have special NetServer local SCSI instructions to create the NetRAID Assistant installation floppy disks. Label the floppy disks HP NetRAID Assistant 1 and HP NetRAID Assistant 2. HP NetServer Installation Guide - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 37
Navigator CD, insert the boot floppy for Windows NT4.0, and exit Navigator to reboot the server. 2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: 3. Load drivers Mbps. Do not use the Auto setting. HP NetServer Installation Guide 27 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 38
down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server. The server boots from the CD and displays the Navigator Main menu. NOTE If prompted that the HP NetServer Navigator BIOS is a newer version, choose Continue and go - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 39
8000 These procedures provide instructions for servers using NetRAID, SureStore E 12H, and Model 30/FC shared storage solutions Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 40
complete, the D5013A NIC drivers must be manually set to the correct instructions for servers using Fibre Channel shared storage solutions (HP Rack Storage/12FC. Configure NetServer Hardware and BIOS 1. System A and System B can both be powered on. 2. Insert the HP NetServer Navigator CD in the CD - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 41
.0 and exit Navigator to reboot the server. 2. When Windows NT Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: • The drivers are loaded from the NT 4.0 Drivers floppy disk you created from the Navigator CD. • First, load the driver for the - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 42
HBA Driver. LXr 8500 These procedures provide instructions for servers using NetRAID-3Si and the HP Rack Storage/12 shared storage solution. Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 43
(Fibre Channel) These procedures provide instructions for servers using Fibre Channel shared storage solutions (HP Rack Storage/12FC). Configure NetServer Hardware and BIOS 1. System A and System B can both be powered on. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 44
Symbios boot banner during reboot and set the options you need; otherwise allow the server to reboot. The server boots from the CD and displays the Navigator Main menu. NOTE If prompted that the HP NetServer Navigator BIOS is a newer version, choose Continue and go to step 6; otherwise go to step - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 45
drivers must be manually set Driver. Install Service Pack for All HP NetServers Refer to the Configuration Guide for your cluster configuration and install the applicable Microsoft Service Pack. If using SP3 do not install the Hot Fix at this time. NOTE Do not install the Microsoft Cluster Server - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 46
Devices using FCArray Assistant in the supplement Create the Array File Systems Use the instructions below and Windows NT Disk Administrator to partition, assign drive letters, and format the with local (non-shared) disks followed by the shared disk arrays. HP NetServer Installation Guide 36 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 47
disk in the partition (the default). In the following example, Disk 1 has been partitioned and Disk Administrator assigned a temporary drive letter to the disk array. HP NetServer Installation Guide 37 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 48
, Partitioned Disk Array NOTE Do not partition a disk into separate drives. Microsoft Cluster Server Software will only manage one partition per disk. 4. Repeat steps 1 through 3 to Administrator assigned the next sequential letter to the disk array. HP NetServer Installation Guide 38 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 49
Letter. Disk Administrator displays the Assign Drive Letter dialog. 3. In the dialog, select a drive letter, and click OK. To avoid confusion later, HP recommends that you choose sequential drive letters. The example in this guide uses drive letters X and Y. HP NetServer Installation Guide 39 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 50
that File System is set for NTFS. 4. In the Volume Label field type a label (name) for the drive. Choose a descriptive label such as "Shared Drive X.". HP NetServer Installation Guide 40 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 51
in the cluster. The following example depicts both drives formatted with permanent drive letters assigned. Disk Administrator, Formatting and Assigning Volume labels 7. Exit Disk Administrator. HP NetServer Installation Guide 41 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 52
the Component CD of Microsoft Windows NT Server, Enterprise Edition in the CD-ROM drive of System B. 2. Run the Microsoft Cluster Server setup Cluster Server software setup of System A. Click Next. Microsoft Cluster Administrator, Assigning a Cluster Name HP NetServer Installation Guide 42 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 53
the right column are shared by both systems. Normally you would share all disks listed. Microsoft Cluster Server Setup, Assigning Shared Disks to the Cluster 8. Setup prompts you to select a disk (quorum adapter, and System A and B reside on the same IP subnet. HP NetServer Installation Guide 43 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 54
IP Address already filled in. However, your configuration may display the Client LAN first. Microsoft Cluster Server Setup, Assigning a Network Name to the intra-cluster LAN 10. Repeat the previous step for has the highest priority. See the example dialog below. HP NetServer Installation Guide 44 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 55
specifications and starts the cluster service. 15. Microsoft Cluster Server is now fully installed on System A. Reboot System A. 16. To finish installation of the Microsoft Cluster Server, leave System A running, go to the next procedure and install MSCS on System B. HP NetServer Installation Guide - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 56
not already downloaded clusfixi.exe, see "Software" in part "1 What's Needed." 2. Install the Microsoft hotfix clusfixi.exe on System A and System B. NOTE When downloading the file, refer to the Microsoft readme file for instructions on installing the hotfix. HP NetServer Installation Guide 46 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 57
to download this program. Run CIT Follow the instructions in the CIT program. If additional information is needed refer to CIT on-line help. CIT help is context sensitive and has been expanded to provide detailed instructions for each step of the program. HP NetServer Installation Guide 47 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 58
NetRAID Supplement to HP NetServer Microsoft Cluster Installation Guide 8 March 1999 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 59
and troubleshoots the Microsoft Cluster Server. Hewlett-Packard Company assumes this person is qualified to service computer equipment and trained to recognize hazards in products with hazardous energy levels. NOTE Hewlett-Packard only supports and recommends installation of clustered HP NetServer - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 60
the HP NetServers Microsoft Cluster Installation Guide. VERSION HISTORY...2 1 WHAT'S NEEDED ...4 SOFTWARE...4 NEED MORE HELP?...4 OBTAIN HP NETRAID UTILITIES ...4 2 NETSERVER HARDWARE SETUP ...6 3 SHARED STORAGE HARDWARE SETUP 7 HP RACK STORAGE/12 SETUP...7 HP RACK STORAGE/8 SETUP...8 HP STORAGE - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 61
to unpack the archive. • Follow the instructions in the readme.txt file to create the installation floppy disk. Label the floppy disk NetRAID-3Si Cluster Firmware and Driver then go to part 2 "NetServer Hardware Setup." NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 4 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 62
Floppy Disk NR Cluster Firmware and Driver HP NetRAID Assistant 1 HP NetRAID Assistant 2 7. Label three blank formatted floppy disks as listed. 8. Copy the contents of each subdirectory to the appropriate floppy disk. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 5 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 63
PCI slots specified by the HP NetServer Configuration Guide for your cluster configuration. 2. Make sure that previously installed adapters are in the correct PCI slots. NOTE For clusters using HP NetRAID adapters, typically, only one is provided (installed) in the server for management of shared - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 64
) in each Rack Storage/12. Follow the instructions supplied with the Controller for installation. to part "4 Cluster Cabling and Setup" in the Installation Guide or setup another share storage device such as the Rack Storage/8. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 65
option switches as shown below. Option Switches Set to Up Down %ULGJH &DEOH HP Rack Storage/8 Single Bus Configuration Connect the Bridge Cable Use the bridge cable included Cluster Cabling and Setup" in the Installation Guide NetRAID Supplement to the HP NetServer Microsoft Cluster Installation - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 66
Interior Before connecting the disks housed in the HP Storage System/6, set up the internal cables to support the cluster. To gain access proceed as chassis. HP Storage System/6 Cabinet with Bezel and Side Cover Removed NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 9 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 67
Verify and Reconnect Internal Cabling Using the schematic view of the HP Storage System/6's internal cabling shown below, check and if necessary, reroute the three 5182-9326 Storage System/6 Cabinet Internal Cabling NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 10 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 68
A or B at this time. You must configure the HP NetRAID Adapter and install Microsoft Windows NT Server, Enterprise Edition before attaching the shared storage unit. to part "4 Cluster Setup and Cabling" of the Installation Guide NetRAID Supplement to the HP NetServer Microsoft Cluster Installation - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 69
not cross. That is, make sure to connect channel 0, 1, and 2 from one HP NetServers through the storage cabinet to channel 0, 1, and 2 respectively on the second HP NetServer. Follow the cabling diagram(s) in the configuration guide carefully. It is a good idea to number or color-code the cable ends - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 70
5 NetServer Software Setup This part of the supplement is intentionally left blank. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 13 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 71
the system. 3. The system will boot to DOS and run the HP NetRAID firmware flash utility. Follow the instructions to update the firmware on all NetRAID-3Si adapters. When complete, cycle power on the system to reboot. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 14 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 72
it. HP NetRAID HP NetRAID Express Tools when all adapters have been configured. 9. Power down System A, power up System B, and repeat the procedures for System B starting at the beginning of this part (Update the Firmware). NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 73
10. Exit HP NetRAID Express Tools when all adapters have been configured. 11. Power down System A, power up System B, and repeat the procedures for System B starting at the beginning of this part (Update the Firmware). NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 16 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 74
system log during reboot. The entry is: Event ID: Source: Type: Description: 4 mraidnt Error Driver detect an internal error in its data structure for. This is a spurious event and may be ignored. No error occurred. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 17 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 75
Server Software is fully installed after part "7 Microsoft Cluster Server Software Setup" in the Installation Guide, make sure that only one HP NetServer Software Setup" of the Installation Guide. Set RAID Levels on a Cluster Use these instructions to set up HP NetServer cluster RAID level 1, 5, 10 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 76
for use. Out of service because a fault occurred. Rebuilding an array on a new drive. Refer to the HP NetRAID User Guide in Information Assistant for more information about HP NetRAID Assistant. Setup all data is still NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 19 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 77
the dialog and click Next. The Configuration Wizard displays its Array Definition window. HP NetRAID Array Definition 3. In the Array Definition window define an array by selecting 3 and 4 to define identical arrays. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 20 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 78
you have defined the cluster's arrays, initialize the arrays you defined. HP NetRAID Assistant initializes all arrays at the same time. To initialize the 2.1 Parity 2 Block 2.2 3 Parity 3 Block 3.1 Block 3.2 NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 21 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 79
in the dialog and click Next. The Configuration Wizard displays its Array Definition window. HP NetRAID Array Definition 3. In the Array Definition window define an array by selecting the storage capacity for the NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 22 - HP D5970A | HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 80
's arrays, initialize the arrays you defined. HP NetRAID Assistant initializes all arrays you have defined HP NetRAID Initialization may be time consuming. 2. When initialization is complete, exit HP NetRAID Assistant. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide
![](/manual_guide/products/hewlettpackard-lh3000r-hp-netserver-lc-3-netraid3si-installation-guide-6043d3d/1.png)
Microsoft Cluster Installation Documentation
for
HP NetServer LH3 with HP Rack Storage/12
& HP NetRAID-3Si Adapter
To assist you in installing your HP NetServer Microsoft Cluster, this file contains the documents
listed below in one pdf file.
•
Installation Overview
- This page provides an overview of the installation steps provided in
the Installation Guide.
•
Configuration Guide
- This guide provides configuration information specific to your cluster
configuration that you will need during installation of your cluster.
•
HP NetServer Microsoft Cluster Installation Guide
- This is the first of two documents used
to install the cluster.
It covers the installation of all cluster supported HP NetServers and the
cluster software, and references the Shared Storage Supplement for installation and setup of the
shared storage.
•
Shared Storage Supplement
- This supplement is specific to the shared storage device you are
using and must be used with the installation guide.
It provides instructions for installing and
setting up your shared storage devices.
20 January 2000
(See next page)