HP D5970A hp netserver lh 3000 netraid-2m config guide — for Micr
HP D5970A - NetServer - LCII Manual
![]() |
View all HP D5970A manuals
Add to My Manuals
Save this manual to your list of manuals |
HP D5970A manual content summary:
- HP D5970A | hp netserver lh 3000 netraid-2m config guide — for Micr - Page 1
Storage/12) Windows® 2000 Advanced Server Cluster Configuration Guide Introduction This document defines the server cluster configurations supported by Hewlett-Packard for interconnection of two HP Netserver LH 3000 servers and one or two HP Rack Storage/12 disk drive enclosure(s), with Microsoft - HP D5970A | hp netserver lh 3000 netraid-2m config guide — for Micr - Page 2
Driver Physical drive location Disk drives SCSI bus SCSI IDs System software Navigator CD-ROM Operating system Service all drivers obtained from Navigator CD-ROM, version L.20.00, or later) Server internal drive bays, or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables - HP D5970A | hp netserver lh 3000 netraid-2m config guide — for Micr - Page 3
IDs Cables SCSI Power distribution Layout Specification Any HP drive supported by storage enclosure. Any combination of HP disk models is allowed in an array, Parameter Network Connection Specification HP D5954A crossover cable, or equivalent. NIC Quantity Model Driver The intra-cluster LAN - HP D5970A | hp netserver lh 3000 netraid-2m config guide — for Micr - Page 4
Any LAN One, minimum Any model that is on both the HP Tested Products List and the Microsoft® Hardware Compatibility List Vendor-supported driver If the NIC used is the same as that of the intra-cluster LAN, then the client LAN driver must be the same as that of the intra-cluster LAN - HP D5970A | hp netserver lh 3000 netraid-2m config guide — for Micr - Page 5
NetRAID-2M Controllers 0 1 NOTES: 2. Cables between the servers and shared storage cabinets can be any HP LVD SCSI cable up to 10 meters. See "Cables"in the Shared Storage Configuration table in the guide for a list of cables that can be used. 3. Another NetRAID Adapter may be installed in each - HP D5970A | hp netserver lh 3000 netraid-2m config guide — for Micr - Page 6
LH30002K2M Power Cabling to Separate Power Circuits 8/13/01 6 - HP D5970A | hp netserver lh 3000 netraid-2m config guide — for Micr - Page 7
Versions 13 August 2001 Initial release LH30002K2M © Copyright 2001, Hewlett-Packard Company 8/13/01 7
![](/manual_guide/products/hewlettpackard-lh3000r-hp-netserver-lh-3000-netraid2m-config-guide-microsoft-windows-2000-clusters-pdf-290k-8132001-2b13d14/1.png)
8/13/01
1
HP Netserver LH 3000 with
NetRAID-2M (HP Rack Storage/12)
Windows
°
2000 Advanced Server
Cluster Configuration Guide
Introduction
This document defines the server cluster configurations supported by Hewlett-Packard for interconnection of
two HP Netserver LH 3000 servers and one or two HP Rack Storage/12 disk drive enclosure(s), with
Microsoft
Cluster Server software.
These configurations provide high server cluster availability and
minimize single points of failure (SPOFs).
A configuration certified and supported by both Hewlett-Packard
and Microsoft
is included, but any cluster configuration that conforms to the guidelines of this document
will be supported by Hewlett-Packard.
Deviations from the supported configurations can result in an
inoperative cluster, an operating cluster with degraded performance, or hidden SPOFs.
Therefore, deviations
are not supported.
For revision/update information on this document, refer to
Versions
on page 7.
Cluster Configuration Elements
This section identifies the hardware components, system software, network interfaces, and power distribution
arrangement required to build an operational server cluster supported by Hewlett-Packard.
The various
server cluster elements are listed below, and their associated configuration data is detailed in separate tables
and illustrations that follow.
•
Server configuration
•
Shared storage configuration
•
Microsoft
and HP certified server configuration
•
Intra-cluster (heartbeat) LAN configuration
•
Client LAN configuration
•
SCSI cabling and power distribution configuration
Server Configuration
Parameter
Specification
Server
Type
HP Netserver LH 3000, Ultra 3 models
Number of nodes
Two
Each node must be the same server type, but nodes may differ in their CPU clock
speeds and cache sizes, and amounts of main memory.
Clock speed
1 GHz
Number of CPUs
Two
BIOS
Version 4.06.03 RN, or later
CPU cache
Any size
RAM
256 MB, minimum.
Must be HP.
Number of power
supplies
Two standard, three required for redundancy, four for redundant power cords