- HP D5970A | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows NT4.0 Cluste - Page 1
your clustered NetServers. This guide is prescriptive; it describes the configurations supported by HP. Any deviance to these configurations Cluster Type of SPUs Installation Number of nodes Shared Storage LANs: Client LAN Intra-cluster (Heartbeat) LAN Power source HP NetServer LH 4 Each node - HP D5970A | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows NT4.0 Cluste - Page 2
external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP (hot swap or fixed) Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant HP NetRAID-3Si Adapter D5955A 1 W.01.30 B.02.02 - HP D5970A | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows NT4.0 Cluste - Page 3
be composed of all the same disk model (i.e., part number and suffix). Different size or speed disks are not HP D5013A/B (10/100TX PCI) 3.27.00.0001 or later 3 Client LAN Any LAN Any that is on both the HP Tested Products List and the Microsoft Hardware Compatibility List. Vendor supported driver - HP D5970A | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows NT4.0 Cluste - Page 4
No. of NICs 1 Client LAN must use the same driver as the Intra-cluster LAN. 1 minimum Shared Storage Cabling This part of the guide defines the allowable cabling configuration for clusters using the HP NetServer LH 4 and HP Rack Storage/12's. Only this cabling configuration and these cables are - HP D5970A | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows NT4.0 Cluste - Page 5
HP Microsoft Cluster Server with Rack Storage/12's 5 - HP D5970A | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows NT4.0 Cluste - Page 6
Power Cabling to Separate Power Source 6 - HP D5970A | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows NT4.0 Cluste - Page 7
models. Added 700 MHz. Added support for NetRAID-1Si as a local removed from the configuration guide. Also clarified wording for number of power supplies is "3 required, 4 for redundancy." Revised SPU clock speeds to add 550 MHz. Revised ac power cabling diagram to depict connecting power to each HP
HP NetServer LH 4
with
NetRAID-3Si (HP Rack Storage/12
Cluster Configuration Guide
22 February 2001
(see
Versions
at the end of this document)
Introduction
This document defines the supported HP NetServer LH 4 configurations with HP Rack Storage/12’s and
Microsoft Cluster Server.
These configurations minimize single points of failure (SPOF) and provide
extended availability.
The specific configuration certified and supported by both Hewlett-Packard and
Microsoft is defined, as are other guidelines to assist you in configuring your clustered NetServers.
This
guide is prescriptive; it describes the configurations supported by HP.
Any deviance to these
configurations can result in an inoperative cluster or an operating cluster with degraded performance,
hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LH 4
Each node must be the same model SPU, but may have different sizes of
main memory and cache, and different CPU clock speeds.
Installation
Pedestal or racked
Number of nodes
2
Shared Storage
HP Rack Storage/12 with HP NetRAID-3Si controller and HP disks.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
HP D5013A/B with crossover cable. See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power