HP D5970A HP Netserver LH 4 Rack Storage/12FC Installation Guide
HP D5970A - NetServer - LCII Manual
View all HP D5970A manuals
Add to My Manuals
Save this manual to your list of manuals |
HP D5970A manual content summary:
- HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 1
HP NetServer Microsoft Cluster Installation Guide - This is the first of two documents used to install the cluster. It covers the installation of all cluster supported HP using and must be used with the installation guide. It provides instructions for installing and setting up your shared storage - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 2
8 February 2000 1 December 1999 Version History Corrected discrepancies with shared storage PCI slots. See the Configuration Guide. Package release - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 3
, etc. Gather: Hardware È Software (Windows NT, NIC drivers, etc.) IP Addresses, subnet mask, etc. User names, Service Pack 3 only) Testing È Run: Hardware Verification and Labeling Utility Cluster Installation Test (CIT) How to do it! (See the referenced part in the Installation Guide - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 4
This page intentionally left blank. - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 5
points of failure (SPOF), provides maximum availability, and has been certified by Hewlett-Packard and Microsoft. This guide is prescriptive; it describes the configuration supported by HP. Any deviance to this configuration can result in an inoperative cluster or an operating cluster with degraded - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 6
Use - Embedded RAID, NetRAID-3Si, or any manufacturer or driver in any available I/O slot May Not Use - NetRAID-1 or NetRAID-3 SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP. Any HP cables that meet SCSI specifications and any SCSI bus speed - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 7
D6020A 5 meter D6982A 10 meter D6983A Only required for Duplex FCArray Card configuration. HP D6976A 6-port fibre channel 1 LANs LAN connection NIC: Model Driver No. of NICs SPU I\O slot Intra-cluster (Heartbeat) LAN HP D5954A crossover cable or any equivalent The intra-cluster LAN may only be - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 8
Shared Storage Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer LH4, one HP Rack Storage/12FC and two HP Rack Storage/12s. Only these cabling configurations and cables are supported. However, only one Rack Storage/12 can be used. 4 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 9
HP Microsoft Cluster using HP Rack Storage/12FC and Rack Storage/12 without 6 Port Fibre Channel Hub (Simplex Operation) 5 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 10
HP Microsoft Cluster using HP Rack Storage/12FC and Rack Storage/12 and 6 Port Fibre Channel Hub (Duplex Operation) 6 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 11
Power Cabling to Separate Power Circuits 7 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 12
Versions 8 February 2000 1 December 1999 Corrected discrepancies in the text and installation diagrams for the Shared storage PCI slots and removed NetRAID-1Si for use as Local Storage. Initial release 8 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 13
HP NetServer Microsoft Cluster Installation Guide with Shared Storage System Supplement Rack Storage/12FC Rack Storage/12 Rack Storage/8 Storage System/6 HP SureStore E 12H Disk Array or HP A3661B Model 30/FC High Availability Disk Array 18 January 2000 (See Version History below) - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 14
This page intentionally left blank. HP NetServer Installation Guide 2 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 15
be read before performing the associated instruction(s). Do not proceed beyond a Servicing Any service, adjustment, maintenance, or repair must be performed only by authorized service . The following trademarks are used in this manual: • Microsoft and MS-DOS are U.S. HP NetServer Installation Guide 3 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 16
FILE SYSTEMS...36 7 MICROSOFT CLUSTER SERVER SOFTWARE SETUP 42 INSTALL MSCS ON SYSTEM A...42 INSTALL MSCS ON SYSTEM B...46 INSTALL SERVICE PACK OR HOT FIX ...46 8 CLUSTER TESTING ...47 HARDWARE VERIFICATION AND LABELING UTILITY 47 CLUSTER INSTALLATION TEST...47 HP NetServer Installation Guide 4 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 17
. The basic cluster consists of two HP NetServer systems instructions in part 5 for the LC3. Initial release Intended Audience The guide is for the person who installs, administers, and troubleshoots the Microsoft Cluster Server. Hewlett-Packard assumes this person is qualified to service - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 18
NOTE Hewlett-Packard only supports and recommends installation of clustered HP NetServer systems using Microsoft Cluster Server software by a Microsoft or HP Cluster Certified Installer. HP NetServer Installation Guide 6 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 19
A Graphical Overview to Setting Up the Cluster CAUTION Departing from the sequence shown here can cause unnecessary work and unpredictable results. HP NetServer Installation Guide 7 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 20
. 2. On the site navigator bar, select SEARCH, then search for Q147222 in the "Support & Knowledge Base" category. 3. On the Search Results page, select Group of Hotfixes for Exchange 5.5 and IIS 4.0, then follow the ftp path to download the "clusfixi.exe" file. HP NetServer Installation Guide 8 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 21
is specified in the Configuration Guide for your cluster. • Cluster Installation Test. Downloaded from the Certified Installer Corner under Install & Configure on the HP NetServer Clustering Solutions web site. • NIC drivers. Download HP drivers from Software Downloads page under Install & Configure - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 22
to the Shared Storage Systems and must be installed in specific PCI slots. See the Configuration Guide for your cluster configuration for the HP NetServer PCI slots to use. See instructions supplied with the component or see part "2 NetServer Hardware Setup" of the Shared Storage Supplement for - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 23
3 Shared Storage Hardware Setup part "3 Shared Storage Hardware Setup" in the Shared Storage Supplement HP NetServer Installation Guide 11 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 24
instructions in the shared storage supplement. In addition you should have rack layouts of your system printed from the HP NetServers Rack Assistant program. If not, see HP NetServers web site to download called the client LAN. NOTE See the Configuration Guide for your cluster for the PCI slots to - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 25
Install Windows NT following a procedure specific to your HP NetServer as listed below. Secondly, you will install the applicable Service Pack on the NetServer. Select your procedure from the NT 4.0 Enterprise Edition, and No for automated NOS installation. HP NetServer Installation Guide 13 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 26
intra-cluster LAN driver version as specified in the Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice, once for sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 27
intra-cluster LAN driver version as specified in the Configuration Guide for your cluster. If you are using two HP D5013A/B NICs, load the driver twice, once for sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 28
intra-cluster LAN driver version as specified in the Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice, once IP addresses must be on different subnets. LH3 These procedures provide instructions for servers using NetRAID, SureStore E 12H, and Model 30 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 29
manually specify the mass storage drivers: • The drivers are loaded from the NT 4.0 Drivers floppy disk you created from the Navigator CD. • First, load the driver LAN driver version as specified in the Configuration Guide for your cluster. If you are using two HP D5013A/B NICs, load the driver twice - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 30
4. Once the NT installation is complete, the D5013A/B NIC drivers must be manually set to the correct LAN speed. Log on and from the start menu select: Settings, Control return to the Navigator main menu by clicking the Back button twice on the displayed window. HP NetServer Installation Guide 18 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 31
drivers you need. If you are using the embedded SCSI channels, load the Symbios driver at this time. 4. Continue the installation and select the following options when prompted: • Choose the unpartitioned space and install Windows NT. • Choose NTFS file system HP NetServer Installation Guide - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 32
driver version as specified in the Configuration Guide for your cluster. If you are using two HP D5013A/B NICs, load the driver complete, the D5013A/B NIC drivers must be manually set to the correct LAN speed setting. LH 4 These procedures provide instructions for servers using NetRAID, SureStore E - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 33
manually specify the mass storage drivers: • The drivers are loaded from the NT 4.0 Drivers floppy disk you created from the Navigator CD. • First, load the driver LAN driver version as specified in the Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice, - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 34
Once the NT installation is complete, the D5013A NIC drivers must be manually set to the correct LAN speed. Log on . LH 4 (Fibre Channel) These procedures provide instructions for servers using the HP Rack Storage/12FC. Configure NetServer Hardware and BIOS HP NetServer Installation Guide 22 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 35
intra-cluster LAN driver version as specified in the Configuration Guide for your cluster. If you are using two HP D5013A/B NICs, load the driver twice, once for . 4. Once the NT installation is complete, the D5013A/B NIC drivers must be manually set to the correct LAN speed. Log on and from the - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 36
with Install Fibre Channel HBA Driver. LPr These procedures provide instructions for servers using NetRAID and SureStore instructions to create the NetRAID Assistant installation floppy disks. Label the floppy disks HP NetRAID Assistant 1 and HP NetRAID Assistant 2. HP NetServer Installation Guide - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 37
intra-cluster LAN driver version as specified in the Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice, once for subnets. 4. Once the NT installation is complete, the D5013A NIC drivers must be manually set to the correct LAN speed. Log on and from the - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 38
Library. Select NetRAID Assistant for WindowsNT and Windows95 from the list and then the Execute button. Follow the instructions to create the NetRAID Assistant installation floppy disks. Label the floppy disks HP NetRAID Assistant 1 and HP NetRAID Assistant 2. HP NetServer Installation Guide 26 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 39
intra-cluster LAN driver version as specified in the Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice, once for subnets. 5. Once the NT installation is complete, the D5013A NIC drivers must be manually set to the correct LAN speed. Log on and from the - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 40
the intra-cluster and the client LAN. Be sure to load the correct intra-cluster LAN driver version as specified in the Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice, once for the intra-cluster NIC and once for the client NIC. • Make sure TCP - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 41
the IDE bus. • Finally, load any other mass storage drivers you need. If you are using NetRAID for shared storage do not load the HP NetRAID driver at this time. It will be loaded later. 3. Continue the installation and select the following options when prompted: HP NetServer Installation Guide 29 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 42
driver version as specified in the Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver is complete, the D5013A NIC drivers must be manually set to the correct LAN provide instructions for servers using Fibre Channel shared storage solutions (HP Rack Storage - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 43
manually specify the mass storage drivers: • The drivers are loaded from the NT 4.0 Drivers floppy disk you created from the Navigator CD. • First, load the driver LAN driver version as specified in the Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice, - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 44
. 4. Once the NT installation is complete, the D5013A NIC drivers must be manually set to the correct LAN speed. Log on and from the Channel HBA Driver. LXr 8500 These procedures provide instructions for servers using NetRAID-3Si and the HP Rack Storage server. HP NetServer Installation Guide 32 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 45
driver version as specified in the Configuration Guide for your cluster. If you are using two HP D5013A/B NICs, load the driver is complete, the D5013A/B NIC drivers must be manually set to the correct LAN speed provide instructions for servers using Fibre Channel shared storage solutions (HP Rack - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 46
NOTE If prompted that the HP NetServer Navigator BIOS is a 's Needed" of the installation guide supplement for additional information. manually specify the mass storage drivers: • The drivers are loaded from the NT 4.0 Drivers floppy disk you created from the Navigator CD. • First, load the driver - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 47
. 4. Once the NT installation is complete, the D5013A/B NIC drivers must be manually set to the correct LAN speed. Log on and from the Driver. Install Service Pack for All HP NetServers Refer to the Configuration Guide for your cluster configuration and install the applicable Microsoft Service - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 48
Devices using FCArray Assistant in the supplement Create the Array File Systems Use the instructions below and Windows NT Disk Administrator to partition, assign drive letters, and format the with local (non-shared) disks followed by the shared disk arrays. HP NetServer Installation Guide 36 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 49
disk in the partition (the default). In the following example, Disk 1 has been partitioned and Disk Administrator assigned a temporary drive letter to the disk array. HP NetServer Installation Guide 37 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 50
and OK when prompted. NOTE In the following example, Disk 2 has been partitioned and Disk Administrator assigned the next sequential letter to the disk array. HP NetServer Installation Guide 38 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 51
Letter. Disk Administrator displays the Assign Drive Letter dialog. 3. In the dialog, select a drive letter, and click OK. To avoid confusion later, HP recommends that you choose sequential drive letters. The example in this guide uses drive letters X and Y. HP NetServer Installation Guide 39 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 52
that File System is set for NTFS. 4. In the Volume Label field type a label (name) for the drive. Choose a descriptive label such as "Shared Drive X.". HP NetServer Installation Guide 40 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 53
in the cluster. The following example depicts both drives formatted with permanent drive letters assigned. Disk Administrator, Formatting and Assigning Volume labels 7. Exit Disk Administrator. HP NetServer Installation Guide 41 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 54
about the installation process outlined here, see the Microsoft Cluster Server Administrators Guide. Install MSCS on System A MSCS installation includes slightly different software setups for Click Next. Microsoft Cluster Administrator, Assigning a Cluster Name HP NetServer Installation Guide 42 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 55
NT installation. Type a Network Name for the LAN Adapter, and check Enable for cluster use. HP recommends that you identify the LAN adapter according to use (for example, intra-cluster LAN). When you LAN adapter, and System A and B reside on the same IP subnet. HP NetServer Installation Guide 43 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 56
communications between nodes. Move the Intra-cluster LAN to the top of the list so it has the highest priority. See the example dialog below. HP NetServer Installation Guide 44 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 57
, Setting the LAN Priority 12. Follow the on-screen instructions to order the adapters so that the intra-cluster LAN Cluster Server software. Setup activates your configuration specifications and starts the cluster service. 15. Microsoft Cluster Server is now fully installed on System A. Reboot - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 58
Service Pack downloaded clusfixi.exe, see "Software" in part "1 What's Needed." 2. Install the Microsoft hotfix clusfixi.exe on System A and System B. NOTE When downloading the file, refer to the Microsoft readme file for instructions on installing the hotfix. HP NetServer Installation Guide - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 59
to download this program. Run CIT Follow the instructions in the CIT program. If additional information is needed refer to CIT on-line help. CIT help is context sensitive and has been expanded to provide detailed instructions for each step of the program. HP NetServer Installation Guide 47 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 60
Fibre Channel Supplement to HP NetServer Microsoft Cluster Installation Guide 1 September 1999 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 61
The following trademarks are used in this manual: • Microsoft and MS-DOS are supports and recommends installation of clustered HP NetServer systems using Microsoft Cluster Server software by a Microsoft or HP Cluster Certified Installer. Cluster vs. Standalone This supplement provides instructions - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 62
Contents NOTE This supplement is incomplete without the HP NetServers Microsoft Cluster Installation Guide. NOTICE...2 INTENDED AUDIENCE ...2 CLUSTER VS. ...9 6 SHARED STORAGE SOFTWARE SETUP 10 INSTALL FIBRE CHANNEL HBA DRIVERS 10 SETUP NODE USER ACCOUNTS ...10 INSTALL FCARRAY ASSISTANT ...10 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 63
. 5. Follow on screen instructions to create two FCArray Assistant download the "HP NetServer LXr 8000 FC Software Driver. Download HP Information Assistant's Main menu: • HP Rack Storage/12 Installation Guide • HP FCArray Assistant Installation and Users Guide Fibre Channel Supplement to the HP - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 64
Host Bus Adapter (D8602A) in the PCI slots specified by the HP NetServer Configuration Guide for your cluster configuration. 2. Make sure that previously installed cards are in the correct PCI slots. 3. Replace the HP NetServer cover(s) and secure thumbscrews. part "3 Shared Storage Hardware Setup - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 65
3 Shared Storage Hardware Setup This section includes instructions for setup of the HP Rack Storage/12FC and HP Rack Storage/12 shared storage devices used in your cluster. Set Configuration Switches for the Rack Storage/12FC (Fibre Channel) Set Configuration Switches for the - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 66
controllers if you are using two FCArray Cards in the Rack Storage/12FC. Install a second SCSI controller (D6025A) in each Rack Storage/12. Follow the instructions supplied with the Controller for installation. to part "4 Cluster Setup and Cabling" of the Installation - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 67
the stacking or arrangement of devices in the rack. When defining your cluster using HP Rack Assistant, a rack layout should have been printed. Lay out devices in the NetServer Software Setup of the Installation Guide" Fibre Channel Supplement to the HP NetServer Microsoft Cluster Installation - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 68
5 NetServer Software Setup This part of the supplement is intentionally left blank. Fibre Channel Supplement to the HP NetServer Microsoft Cluster Installation Guide 9 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 69
complete, remove the diskette, shut down Windows NT®, and reboot the system to load the driver. Setup Node User Accounts To use FCArray Assistant you must setup a new user account What's Needed in this supplement. Fibre Channel Supplement to the HP NetServer Microsoft Cluster Installation Guide 10 - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 70
NOTE Follow the instructions in the FCArray Assistant Installation and User Guide to complete the following tasks. 2. Install both FC part "5 NetServer Software Setup" of the Installation Guide and perform the "Install. Service Pack for All HP NetServers" procedure. Fibre Channel Supplement to the - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 71
Cards in the Rack Storge/12FC. Constraints • No more than 8 physical driver per logical array. • No more than 8 LUNs are permitted per Rack on power for the HP shared storage cabinet(s). Follow the instructions in the FCArray Assistant Installation and User Guide to complete the following tasks - HP D5970A | HP Netserver LH 4 Rack Storage/12FC Installation Guide - Page 72
After setting RAID levels as stated below return to "Create the Array File Systems" in part "6 Shared Storage Software Setup" of the Installation Guide. Fibre Channel Supplement to the HP NetServer Microsoft Cluster Installation Guide 13
Microsoft Cluster Installation Documentation
for
HP NetServer LH4 with HP Rack Storage/12FC & HP Rack Storage/12
To assist you in installing your HP NetServer Microsoft Cluster, this file contains the documents
listed below in one pdf file.
•
Installation Overview
- This page provides an overview of the installation steps provided in
the Installation Guide.
•
Configuration Guide
- This guide provides configuration information specific to your cluster
configuration that you will need during installation of your cluster.
•
HP NetServer Microsoft Cluster Installation Guide
- This is the first of two documents used
to install the cluster.
It covers the installation of all cluster supported HP NetServers and the
cluster software, and references the Shared Storage Supplement for installation and setup of the
shared storage.
•
Shared Storage Supplement
- This supplement is specific to the shared storage device you are
using and must be used with the installation guide.
It provides instructions for installing and
setting up your shared storage devices.
8 February 2000
(See Version History on the next page.)