HP D5970A HP Netserver LH 6000 NetRAID-4M Config Guide for Windows 2000 Advan
HP D5970A - NetServer - LCII Manual
View all HP D5970A manuals
Add to My Manuals
Save this manual to your list of manuals |
HP D5970A manual content summary:
- HP D5970A | HP Netserver LH 6000 NetRAID-4M Config Guide for Windows 2000 Advan - Page 1
HP NetServer LH6000 with NetRAID-4M (HP Rack Storage/12) Windows® 2000 Advanced Server Cluster Configuration Guide 27 March 2001 (see Versions at the end of this document) Introduction This document defines the configurations that Hewlett-Packard supports for the HP NetServer LH6000, HP Rack - HP D5970A | HP Netserver LH 6000 NetRAID-4M Config Guide for Windows 2000 Advan - Page 2
server's default boot order as listed below: IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI64-8, PCI64-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1 P1 - Client LAN - D5013B P7- Shared Storage - NetRAID-4M Booted from Embedded DAC Local Controller Driver Physical drive location - HP D5970A | HP Netserver LH 6000 NetRAID-4M Config Guide for Windows 2000 Advan - Page 3
. It may not be used for client communication. Client LAN Any LAN Embedded NIC Hptxnt5.sys 4.02.27 (Navigator L.20.00) or later 1 Any that is on both the HP Tested Products List and the Microsoft® Hardware Compatibility List. Vendor supported driver NOTE If the NIC used is the same as the - HP D5970A | HP Netserver LH 6000 NetRAID-4M Config Guide for Windows 2000 Advan - Page 4
HP NetServer LH6000 Cluster using HP Rack Storage/12 4 - HP D5970A | HP Netserver LH 6000 NetRAID-4M Config Guide for Windows 2000 Advan - Page 5
Power Cabling to Separate Power Circuits 5 - HP D5970A | HP Netserver LH 6000 NetRAID-4M Config Guide for Windows 2000 Advan - Page 6
Versions 27 March 2001 14 March 2001 Corrected NetRAID-1M/2M driver name and version. Initial release © Copyright 2001, Hewlett-Packard Company 6
1
HP NetServer LH6000
with
NetRAID-4M (HP Rack Storage/12)
Windows
2000 Advanced Server
Cluster Configuration Guide
27 March 2001
(see
Versions
at the end of this document)
Introduction
This document defines the configurations that Hewlett-Packard supports for the HP NetServer LH6000,
HP Rack Storage/12 and Microsoft
Cluster Server.
These configurations minimize single points of
failure (SPOF) and provide extended availability.
The specific configuration certified and supported by
both Hewlett-Packard and Microsoft
is defined, as are other guidelines to assist you in configuring your
clustered NetServers.
This guide is prescriptive; it describes the configurations supported by HP.
Any
deviance to these configurations can result in an inoperative cluster or an operating cluster with degraded
performance, hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in a Cluster
•
Cluster
•
SPUs
•
Local and Shared Storage
•
Intra-cluster and Client LANs
•
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LH6000
Each node must be the same SPU, but may have different clocks speeds,
main memory sizes, cache sizes, and number of CPUs.
Number of nodes
2
Shared Storage
HP Rack Storage/12 with HP NetRAID-4M controller and HP disks.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft
approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
Embedded NIC with crossover cable or equivalent. See
Intra-cluster LAN
below.