HP D5970A HP Netserver LXr 8500 with XP256 Config Guide for Windows NT4.0 Clu
HP D5970A - NetServer - LCII Manual
![]() |
View all HP D5970A manuals
Add to My Manuals
Save this manual to your list of manuals |
HP D5970A manual content summary:
- HP D5970A | HP Netserver LXr 8500 with XP256 Config Guide for Windows NT4.0 Clu - Page 1
Hewlett-Packard or Microsoft. This guide is prescriptive; it describes the configurations supported by HP. Any deviance to these configurations (Heartbeat) LAN Power source System software: Navigator version Operating System Service pack HP NetServer LXr 8500 Each node must be the same model SPU, - HP D5970A | HP Netserver LXr 8500 with XP256 Config Guide for Windows NT4.0 Clu - Page 2
SCSI bus Shared Host Bus Adapters Model Bus Protocol No. of HBAs/Server Firmware BIOS Driver SPU I/O slot SCSI ID Registry Changes SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage /12) Must be HP May use embedded SCSI or NetRAID-3Si in PCI slot P1 otherwise any controller - HP D5970A | HP Netserver LXr 8500 with XP256 Config Guide for Windows NT4.0 Clu - Page 3
FC Cables 2 meter 16 meter 50 meter 100 meter Any 2 HP shortwave cables from the following list: A3583A A3531A A3735A A3736A Shared Storage A3724A HP-10 port Short Wave FC Hub A4839A HP-10 port Long Wave FC Hub 1 per SPOF cluster 1 cluster on 1 hub Fibre Channel Switch Model Fabric Support No - HP D5970A | HP Netserver LXr 8500 with XP256 Config Guide for Windows NT4.0 Clu - Page 4
. It may not be used for client communication. Client LAN Any LAN HP D5013A (10/100TX PCI) 3.27.00.0001 or later 1 P4 Any that is on both the HP Tested Products List and the Microsoft Hardware Compatibility List. Any driver NOTE If the NIC used is the same as the Intra-cluster - HP D5970A | HP Netserver LXr 8500 with XP256 Config Guide for Windows NT4.0 Clu - Page 5
Shared Storage Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer LXr 8500 and the XP256. Only these cabling configurations and cables are supported. DIAGRAMS SHOWING THE SUPPORTED CONFIGURATIONS T8TDÃ8GVTU@S ÃÃÃ9DS@8UÃ8PII@8U Ã ÃÃÃÃÃÃ
![](/manual_guide/products/hewlettpackard-lh3000r-hp-netserver-lxr-8500-xp256-config-guide-windows-nt40-clusters-6565d2c/1.png)
1
HP NetServer LXr 8500
with
XP256 (Fibre Channel or SCSI)
Cluster Configuration Guide
08 February, 2000
Introduction
This document defines the supported HP NetServer LXr 8500 configurations with
the XP256 and
Microsoft Cluster Server.
These configurations minimize single points of failure (SPOF), provide
maximum availability, and have been certified by Hewlett-Packard or Microsoft.
This guide is
prescriptive; it describes the configurations supported by HP.
Any deviance to these configurations can
result in an inoperative cluster or an operating cluster with degraded performance, hidden SPOFs, etc.,
and therefore will not be supported by HP.
What’s Defined in a Cluster
•
Cluster
•
SPUs
•
Local and Shared Storage
•
Intra-cluster and Client LANs
•
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LXr 8500
Each node must be the same model SPU, but may have different clocks
speeds, main memory sizes, cache sizes, and number of CPUs (2, 3, or 4).
Number of nodes
2
Shared Storage
XP256 with FC or SCSI connections.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
HP D5013A with crossover cable. See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.
System software:
Navigator version
L.16.05 or later
Operating System
Microsoft Windows NT Server 4.0, Enterprise Edition or later
Service pack