HP D5970A HP NetServer LXr Pro8 POST and Beep Codes

HP D5970A - NetServer - LCII Manual

HP D5970A manual content summary:

  • HP D5970A | HP NetServer LXr Pro8 POST and Beep Codes - Page 1
    Contents HP NetServer LXrPro8 Error Messages HP NetServer LXrPro8 Beep Codes
  • HP D5970A | HP NetServer LXr Pro8 POST and Beep Codes - Page 2
    HP NetServer LXr Pro8 Error Messages 200 Failure Fixed Disk Since the system does not support IDE drives, this error should Step 1. 3. If the problem still persists, replace the keyboard and repeat Step 1. 4. If the problem persists, call your HP service representative for further assistance.> 212
  • HP D5970A | HP NetServer LXr Pro8 POST and Beep Codes - Page 3
    -- run Setup This error may not occur on the HP NetServer LXr Pro8, as the system supports standard VGA with additional higher resolutions. 230 System RAM persists, the RTC on the system board is faulty. Call your HP service representative for further assistance. 251 System CMOS checksum is bad --
  • HP D5970A | HP NetServer LXr Pro8 POST and Beep Codes - Page 4
    HP Service Representative for further assistance. (This error will occur when the user flashes a new BIOS into the system, as the CMOS area is cleared by the flash utility. Follow the above instructions system board may have a problem. Call your HP service representative for further assistance. 280
  • HP D5970A | HP NetServer LXr Pro8 POST and Beep Codes - Page 5
    through POST, when the BIOS was updating the CMOS and NVRAM data in the system. Actions You Can Take Enter the SETUP menu by pressing the F2 key during the POST, and fix the system configuration. 281 Memory size found by POST different from EISA CMOS This error will occur if new memory is added to
  • HP D5970A | HP NetServer LXr Pro8 POST and Beep Codes - Page 6
    you have additional CPU boards available for this system, replace one CPU board at a time and see if the error goes away. Call your HP service representative for further assistance 2B2h Incorrect Drive A type -- run SETUP This error will be displayed if floppy diskette drive A does not fit the drive
  • HP D5970A | HP NetServer LXr Pro8 POST and Beep Codes - Page 7
    persists, the system board may need to be replaced. Call your HP service representative for further assistance. 2F6 Software NMI failed This error will occur writing to the register to generate an NMI. Since the HP NetServer LXr Pro8 does not support EISA, this error should not happen. Even if this
  • HP D5970A | HP NetServer LXr Pro8 POST and Beep Codes - Page 8
    messages on the monitor when an error occurs before the video display is initialized, generally the BIOS POST error message usually displays on the HP NetServer's message display (located on the control panel). In a few cases, the server emits a series of beeps. The beep codes are defined in the
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Contents
HP NetServer LXrPro8 Error Messages
HP NetServer LXrPro8 Beep Codes