HP D5970A HP Netserver Service Handbook, Volume 2 - Mid
HP D5970A - NetServer - LCII Manual
![]() |
View all HP D5970A manuals
Add to My Manuals
Save this manual to your list of manuals |
HP D5970A manual content summary:
- HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 1
HP NetServer Product Line Service Reference Guide Volume 2 Mid-Range Version 2 Last Updated: June 2001 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 2
Server Division 10955 Tantau Avenue MS-45SLE Cupertino, CA 950140770 © Copyright 2000, Hewlett-Packard Company. Audience Assumptions The guide is for HP authorized service personnel who install, administer, and troubleshoot HP NetServers. The Hewlett-Packard Company assumes you are qualified in the - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 3
, 5/133, 5/166 Pentium™ Processor Board Memory Video Memory - DRAM Flexible Disk Drive Guidelines Exploded View Parts List Keyboards Power Cords Specifications HP NetServer LC 3 System Views Front Control Panel Covers Memory Video Memory Boot Device Priority DIMM Slot LED Blink Codes Processor Error - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 4
Switches 50 Processors 50 Memory Configuration 51 Video Memory - DRAM 51 HP NetServer LE System Updates 51 Loading DOS in a 640K environment if the base memory size is set to 512K. 51 Specifications 52 HP NetServer LF 53 System Views 53 Cover 54 Exploded Views 55 Parts - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 5
Configurations Configuring Switch Settings on the Hot Swap Subsystem Specifications HP NetServer LH 3 and LH 3r System Views Front Control Panel Drive LED Status and Activity Indicators System Board System Switches Specifications HP NetServer LH 4 and LH 4r System Information System Views Front - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 6
Channel 126 SCSI BIOS Address and Boot Device 126 Installing Four or More Disk Drives on One SCSI Channel 126 Boot Problem with Greater than 2 GB HP Disk Array Boot Drive 127 HP C2260A Storage System and the Built-in SCSI Connector 127 Disk Array Controller 127 IDE 240 MB (D1697A) or 270 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 7
Control Panel Connector J1 144 Mass Storage Indicator Lights 145 Cover 146 Exploded Views 147 Parts List 149 Keyboards 150 Power Cords 151 Mass Storage Cables 151 System Board 152 System Board Connectors 153 System Switches and Jumpers 153 Memory Configuration 154 Video - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 8
- HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 9
HP NetServer LC System Views Control Panel Line Voltage Selection Switch Power Cable Clamp Keyboard Mouse Serial Port B Serial Port A Video Parallel Port SCSI External Port PCI Slot 6 PCI or EISA/ISA Slot 5 EISA/ISA Slot 1 1 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 10
Front Bezel and Cover System Board IO Panel Connectors Side view Bezel handles Keyboard Mouse Serial port B Serial port A Parallel port LPT1 Monitor External SCSI port 2 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 11
Power P3 & P4 Main fan connector Slot 3 - PCI Slot 2 - PCI Slot 5 - EISA/ISA Control panel cable connector Battery connector Power Adapter (HP Remote Assistant) Pin 1 ROM Mounting pin SW1 system board switches Processor Board Hard disk activity light Slot 1 - EISA/ISA System Board System Board - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 12
disables one of the two levels of flash ROM write protection (the other level of protection is controlled by the HP Update Utility). ON: The BIOS can be updated by the HP Update Utility. OFF: The BIOS is locked and cannot be updated. BOOT BLOCK DISABLE: Reserved. Must be set to ON - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 13
5 PASSWORD ENABLE: Enables or erases the power-on password maintained in NVRAM. ON: Power-on password functional. OFF: Erases the current power-on password. 6 SMI# ENABLE: Not used - leave in default position OFF: Prevents SMI interrupt. 7 IO CTRL ENABLE: Enables or disables onboard - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 14
memory installed. There are two more banks (four sockets) available for expansion. The maximum memory supported is 192 MB (6 x 32 MB). There are some basic rules to remember when installing SIMMs on the processor board. • The server supports 4 MB and 8 MB (must be 70 ns) and 16 MB and 32 MB (must - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 15
MB and 32 MB SIMMs, the speed must be 60 or 70 ns. Video Memory - DRAM No additional video memory can be installed in the HP NetServer LC. Current video memory is 512 KB. Flexible Disk Drive Guidelines If you need to replace the flexible disk drive with the replacement part - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 16
Exploded View 8 9 10 11 12 14 13 Parts List Fig Description 1 Front bezel 2a 535 MB SCSI HDD 540 MB SCSI HDD 2b 1 GB SCSI HDD 2c 2.1 GB HDD 3 1.44 MB 3.5" Flexible disk drive 4 Mass storage cage 8 7 6 5 4 3 2 1 15 Replacement 5063-5617 D2075-60003 D2386-63001 D2076-63102 D2077 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 17
-2604 1205-0826 1205-0832 5063-5609 5182-0080 5182-0081 5182-0079 0960-0888 D2974-63001 D3577-63001 D2297-63001 D2298-63001 5064-1920 HP D2198A HP D2199A J2970-61001 D3353-69001 D3356-69001 D4859-69001 D3577-69001 D2297-69001 D2298-69001 9 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 18
/French Portuguese Cyrillic Japan/Kanji Italian Arab/English Korea/Hangu Taiwan Power Cords Country Australia/New Zealand Canada/United States Denmark Europe HP Part Number C1405-60301 C1405-60325 C1405-60327 C1405-60330 C3755-60224 C1405-60317 C1405-60320 C1405-60321 C1405-60323 Language Danish - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 19
Specifications Power Supply Power Availability Power Consumption System Dimensions System Weight Operating Altitude Operating Temperature Operating Humidity BTU's Acoustic 100 to 127 VAC ~ 6.0 A or 200 to 240 Volts AC ~ 3.14 A at 50 to 60 Hertz 224 watts peak, 200 watts continuous 301/351 watts - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 20
- HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 21
HP NetServer LC 3 System Views Power Switch Keyboard Lock Lock Flexible Disk Drive EIDE CD-ROM Shelf 3 Hot Swap Drive Bay Hot Swap Drive Bay Lock - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 22
Covers CAUTION The covers are an integral part of the server. The server must be operated with the covers in place to ensure proper airflow for continued reliability and to maintain compliance with radio frequency interference and safety standards. Front Bezel Pocket Top Cover 1 Key Lock 2 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 23
system board for memory expansion Follow these simple rules when you plan to install additional memory DIMMs: • Use only HP DIMMs listed on the Technical Reference Label located inside the HP NetServer top cover, in Information Assistant, or in Order Assistant. • DIMMs can be 32 MB, 64 MB, or 128 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 24
Video Memory Expand video memory by installing two 256 K x 16 (512 KB), 70 Ns, 40-pin SOJ package DRAM ICs. CAUTION Install the chip in the correct orientation. Failure to do so will destroy the DRAM.. Video Slots Boot Device Priority The boot device priority is controlled by the Boot Device - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 25
persists, replace VRM. Check that secondary voltage regulator module (VRM) is correctly seated. If problem persists, replace VRM. ²O O ² O ²²O O O ²² ²²O O CPU Over Temperature CPU or Terminator Board and OFF at 1 Hz in 90/10 proportion of time: non-HP DIMM installed • ON: HP DIMM installed 17 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 26
Exploded Views 15 14 13 12 2 1 11 10 3 4 7 8 9 5 6 18 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 27
21 22 23 20 19 18 17 16 19 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 28
27 28 29 26 25 24 30 20 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 29
23c Memory SDRAM, 256MB, ECC, 100MHZ 24 Power Supply 25 System Fan * Rivets, Plastic, for mounting fan 26 Retainer for Adapter Board Guide 27 Guide, Adapter Board Replacement Exchange Not orderable 5064-1987 5064-1986 5063-5671 5041-1099 D3604-63003 5042-2108 5064-3503 D3349B D3583-69004 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 30
* Filler Assy, Hot-Swap 5063-8391 * Upper Drive Filler Panel 5063-8389 * Hot Swap Cage key 5182-4534 * External Battery, 3.6V 1420-0559 ** HP Navigator CD-ROM ** Diagnostic Assistant Diskette * This part is not on the exploded view. ** This part number is constantly revised. When you order - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 31
Denmark Europe 8120-2956 8120-1689 Switzerland United Kingdom 8120-2104 8120-1351 Mass Storage Cables Cabling Label A B C D E F G Location System backplane SCSI connector to upper-shelf SCSI devices System backplane IDE connector to IDE devices (CDROM or other) System backplane floppy - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 32
System Board Retaining Latches Primary Processor * J25: 100 MHz Diagnostic LEDs Secondary Processor Socket (Terminator Installed In Dual-Ready Configurations) * Processor Fan * J20: N/C 01 2 3 Primary VRM * J26: N/C 0 1 Memory DIMM Sockets 2 3 * Cable connectors labeled with function. - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 33
Specifications Operating Temperature Non-operating Temperature Operating Humidity (noncondensing) Non-operating Humidity (noncondensing) Operating Altitude Non-operating Altitude Height Width Depth Weight Power supply input voltage Power supply output Power Consumption BTUs 5°to 35°C (41°to 95°F) - - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 34
- HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 35
HP NetServer LD Pro System Views Control Panel Flexible Disk CD-ROM Hot Swap Subsystem Keyboard, mouse, serial, and display connectors External SCSI port connectors 27 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 36
Lock Button Power Button Power-On Light Reset Button Hard Disk Activity Light 1 Keyboard Lock Button Keyboard Lock Light Turns the HP NetServer on and off. Note that when the HP NetServer is turned off, the power to the internal circuitry and mass storage devices is disabled; however, AC power is - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 37
- PCI-1 Slot 7 - PCI-1 Slot 6 - PCI-1 Trident J16 9000i PS4 3v Pwr Module J36 AIC 7880 Slot 4 - EISA/ISA Slot 3 - EISA/ISA HP Remote Assistant Connector Battery Connectors Power Supply Cable Connectors SW1 Default Settings: Off On 1 Flash Write Enable 2 Boot Lock Disable 3 Config Valid - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 38
System Board Connectors, Switches, and Jumpers The table below explains the system board markings for all connectors. Connector IDE disk drive cable Keyboard Serial (2) Video PCI slots EISA/ISA slots Fans A, B Power supply on A Power supply PS3: J20 P4: J122 PS4: J17 Processor board slot Fast/Ultra - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 39
disables one of the two levels of flash ROM write protection (the other level of protection is controlled by the HP Update Utility). ON: The BIOS can be updated by the HP Update Utility. OFF: The BIOS is locked and cannot be updated. 2 BOOT BLOCK DISABLE: Reserved. Must be set to ON - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 40
installing additional memory, note the following: • Only these HP DIMMs are supported: DIMM Type HP Product Number 16 MB DIMM D4294A 32 MB DIMM problems, equipment problems, or service calls resulting from the use of non-HP DIMMs. Select "Step 5: Save and exit"and follow the instructions - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 41
) Reseat the DIMM or Move it to another socket or Replace DIMM N/A (normal) Replace with appropriate HP DIMM or Run Diagnostic Assistant to find the problem Run Diagnostic Assistant to find the problem N/A (normal for non-HP DIMM) Replace with appropriate DIMM or Run Diagnostic Assistant to find the - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 42
LED Processor Error Codes Alternating LED Codes: LED LED LED LED 0 1 2 3 ON-OFF-OFF-ON & OFF-ON-ON-OFF Definition Processor chip overtemperature OFF-OFF-ON-ON & ON-ON-OFF-OFF ON-OFF-OFF-OFF & OFF-ON-ON-ON OFF-ON-OFF-OFF & ON-OFF-ON-ON OFF-OFF-OFF-ON & ON-ON-ON-OFF Primary processor chip ( - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 43
If you have a system with a mixture of PCI and ISA or EISA boards perform the following: 1. Install the PCI controller board in slot 9. 2. Go to the EISA Configuration Utility. 3. Select "Step 3: View or edit details." 4. Select "PCI 9 - PCI SCSI Controller" and press F6. 5. Set the top Memory - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 44
0DFFFFh range. Cabling Configurations Duplex, Non-Disk Array Model with Internal Controller This is a standard mass storage configuration as shipped from HP. NOTE If you are installing Ultra SCSI mass storage devices in this NetServer, you must enable Ultra SCSI. SCSI Terminator built into - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 45
Duplex Disk Array Configuration with Dual Channel PCI Controller Board This is one of several possible optional mass storage configurations. You are not limited to the configurations shown on this CD-ROM; this is only given as an example. SCSI Terminator built into cable T IIDDEE C31 System - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 46
On Off 1 2 3 4 5 6 Technical Information Label with configuration information Always set switches 1, 2 and 6 to Off. Switch 1 2 3 4 Function I2C Bus Setting I2C Bus Setting High/Low Addresses Sets SCSI addresses for upper or lower eight addresses Set to Off if not using Fast-Wide (68 pin) SCSI - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 47
On Off Shelf 1 = ID 9 Shelf 2 = ID 10 Shelf 3 = ID 11 On On Shelf 1 = ID 9 Shelf 2 = ID 8 Shelf 3 = ID 11 Exploded Views 1 8 3 2 4 15 18 16 21 17 19 9 7 20 5 6 10 11 12 13 14 39 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 48
22 25 1 23 32 1 26 28 27 29 43 34 33 40 35 36 37 38 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 49
NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the revised part number. If a system board needs to be replaced, remove processor board - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 50
34 Control Panel Bezel 5063-8380 35 Control Panel PCA 5063-0382 36 Card guide Assembly 5063-5697 37 Front Fan 5063-8386 38 Chassis Foot 5042-2122 can be obtained by ordering the HP Cable Kit - Part Number D3588-60001. Only the following HP cables are supported: Cable Diagram C31 C22 A - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 51
Belgian/Flemish Italian Arab/English Korea/Hangu Taiwan Poland Hungarian Turkish HP Part Number D4950-63001 D4950-63025 D4950-63027 D4950-63030 Fr-Canadian German Spanish French Norwegian Swiss Swedish UK Czech Greek Dutch HP Part Number D4950-63016 D4950-63002 D4950-63003 D4950-63004 D4950-63005 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 52
Server Footprint System Weight Keyboard Height Width Depth Weight Cable Length Keyboard cable Ventilated Clearance Sides and Top Front Back 369 x 474.71 mm (14.53 x 18.89 in) 50-70lb (22.7-31.8kg), depending on configuration 3.4 cm (1.4 in) 46.8 cm (18.4 in) 19.8 cm (7.8 in) 1.9 kilograms (4.2 lb.) - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 53
HP NetServer LE System Views Control Panel Detail Reset Desktop Position: Lock 54321 SERIAL B SER IAL A SC SI SERIAL B SERIAL A SCSI Mouse Parallel Keyboard Video 45 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 54
Installation View 46 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 55
NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the revised part number. If a system board needs to be replaced, remove RTC module, any - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 56
Rail Mount Kit (3 pack) * Base Assembly * Flexible disk drive cable * Hard disk drive cable * Not on exploded view HP NetServer LE Keyboards Language US Fr-Canada German HP Part Number C1405-60301 C1405-60302 C1405-60303 Exchange D2156-69001 D2152-69001 D2297-69001 D2298-69001 N/A D2075-69001 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 57
/Kanji Country India/South Africa Japan Switzerland United Kingdom C1405-60321 C1405-60323 C1405-60325 C1405-60327 C1405-60330 C1414-60001 HP Part Number 8120-4211 8120-4753 8120-2104 8120-1351 U19 U18 O N 1 2 3 4 5 6 7 8 WHEN ON: 1 - BIOS UNLOCK 2 - VIDEO DISABLE 3 - CLEAR CONFIG 4- ERASE - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 58
Header (*) Memory Sockets (SIMMs) Control Panel Connection ZIF Microprocessor Socket System Board Switches Processors Processor HP or Intel P/N 486/33DX D2169A (HP) OverDrive/33 D2172A (HP) i486DX2/66 A80486DX2-66 SX OverDrive/66 ODP486SX-66 DX OverDrive/66 ODPR486DX-66 DX OverDrive/66 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 59
Memory Configuration You can install any HP supported 4 MB, 8 MB, 16 MB, and 32 MB SIMMs in any -80 9105 HP NetServer LE System Updates These notes reflect changes for the HP NetServer LE which could not be included with the service manual or were changed at a later date. Service manuals are not - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 60
Enter when the banner appears. If the base memory size is set to 640K, the utility displays only the driver banner with no prompt. The function of this driver does not change the base memory size setting selected in the EISA configuration Utility. Specifications Power Supply Power Availability - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 61
HP NetServer LF System Views Control panel Mass storage shelf 1 (flexible disk drive) Mass storage shelf 9 Keyboard Mouse Serial port B Serial port A Parallel port LPT1 Monitor External SCSI port Slot 9 - PCI Slot 8 - PCI Slot 7 - EISA/ISA Cover screws (5) Slot 1 - EISA/ISA 53 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 62
Control Panel Reset button Hard disk activity lights Power-on light Power button 1 2 Reset Keyboard lock light Keyboard lock button Power button Power-on light Reset button Hard disk activity light 1 Hard disk activity light 2 Keyboard lock button Keyboard lock light Turns the server on and - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 63
Exploded Views 1 4 5 3 2 55 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 64
14 13 12 10 11 16 15 6 9 7 8 56 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 65
at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the revised hold down plate 9 Cable for 2 Fans 10 Fan Assembly 11 LF Card Guide Assembly 12 Battery 13 LF Control Panel PCA 14 LF Control panel Assembly 15 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 66
-60327 C1405-60330 C1414-60001 C1405-60317 C1405-60320 C1405-60321 C1405-60323 Language Danish Fr-Canada German Spanish French Norwegian Swiss Swedish UK HP Part Number C1405-60316 C1405-60302 C1405-60303 C1405-60304 C1405-60305 C1405-60309 C1405-60311 C1405-60312 C1405-60313 Power Cords Language - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 67
Processor Boards New 486/66 Processor Board Cache module installation CPU TYPE DX2 / DX4 J5 DX2D Bank 0 J2 CPU VOLTAGE SELECT DX2/66 DX4/100 Old 486/66 Processor Board J4 MULTI TRIPLE DOUBLE Bank 1/2 Bank 3/4 J4, J5 are in these positions for both DX2/66 and DX4/100 CPU's J1 J2 J3 Bank - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 68
supply Control panel ROM Number J22 J25 J24 J1 J11-J17 J2 J6 J3 U14 System Board Connector J6 This connector is used by the HP Remote Assistant Accessory, a 32-bit EISA Bus Master board used to remotely monitor server functionality. For additional information on this product, see the documentation - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 69
disables one of the two levels of flash ROM write protection (the other level of protection is controlled by the HP Update Utility). ON: The BIOS can be updated by the HP Update Utility. OFF: The BIOS is locked and cannot be updated. BOOT BLOCK DISABLE: Reserved. Must be set to ON - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 70
sockets) available for expansion memory which can be single or double density. The maximum memory supported is 136 MB (4 x 32 MB + 8 MB). The Pentium processor board has 16 Memory No additional video memory can be installed in the HP NetServer LF. Current video memory is 512 KB. Specifications - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 71
HP NetServer LH System Views Control Panel Flexible Disk CD-ROM Hot Swap Subsystem Keyboard, mouse, serial, and display connectors SCSI port connectors HP NetServer LH Pro 63 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 72
Keyboard, Mouse, serial, and display connectors Keyboard, Mouse, serial, and display connectors SCSI port connectors HP NetServer LH HP NetServer LH Plus SCSI port connectors 64 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 73
the control panel. Power Button Power-On Light Reset Button Hard Disk Activity Light 1 Hard Disk Activity Light 2 Turns the HP NetServer on and off. Note that when the HP NetServer is turned off, the power to the internal circuitry and mass storage devices is disabled; however, AC power is still - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 74
Cover CAUTION The cover is an integral part of the server. The server must be operated with the cover in place to ensure proper airflow for continued reliability and to maintain compliance with radio frequency interference and safety standards. 66 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 75
HP NetServer LH Exploded Views 3a 2 1 13 3b 4a 5 4b 6 8 9 7 10 14 15 16 17 18 TO DISK ARRAY 19 11 12 20 67 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 76
21 1 22 23 24 25 1 27 26 29 30 34 31 32 33 68 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 77
NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the revised part number. If a system board needs to be replaced, remove processor board - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 78
* Hot Swap Cage key 5182-4534 * LH SCSI Cable Kit D3588-60001 * HP Navigator CD-ROM 5063-8343 ** * Diagnostic Assistant Diskette 5011-1926 ** This part be obtained by ordering the HP Cable Kit - Part Number D3588-60001. Only the following HP cables are supported: Cable Narrow SCSI (50 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 79
HP NetServer LH Plus Exploded Views 1 2 8 7 15 18 16 17 19 10 9 21 20 3 4 5 11 6 12 13 14 71 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 80
22 24 25 1 23 32 1 28 26 27 29 34 33 72 35 36 37 38 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 81
NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the revised part number. If a system board needs to be replaced, remove processor board and - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 82
Panel Bezel 5063-8369 5063-8380 35 Control Panel PCA 5063-0382 36 Card guide Assembly 37 Front Fan 5063-5697 5063-8386 38 Chassis Foot 39 Power Management D4296-69001 D4297-69001 D3582-69002 D3583-69002 C3610-69050 HP NetServer LH Plus Mass Storage Cables Cabling Label Location Description - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 83
A Intl narrow (50-pin) to wide Fast/wide SCSI adapter (50 5182-4550 Yes (68-pin) adapter pin to 68 pin) B1 I2C cable, system board to hot- 3-pin I2C cable swap backplane 5182-4535 No HP NetServer LH Pro Exploded Views 1 2 8 7 3 4 15 18 16 17 19 10 9 21 20 5 11 6 12 13 14 75 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 84
22 24 25 1 23 40 32 39 26 28 27 29 43 41 42 34 35 33 38 HP NetServer LH Pro Replaceable Parts List 37 36 76 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 85
NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the revised part number. If a system board needs to be replaced, remove processor board and - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 86
Panel Bezel 35 Control Panel PCA 5063-8367 5063-8380 5063-0382 36 Card guide Assembly 37 Front Fan 38 Chassis Foot 5063-5697 5063-8386 5042-2122 39 Exchange D4295-69001 D4296-69001 D4297-69001 D3582-69002 D3583-69002 C3610-69050 HP NetServer LH Pro Mass Storage Cables Labe l C14 C22 A B1 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 87
60320 C1405-60321 C1405-60323 Language Danish Fr-Canada German Spanish French Norway Swiss Swedish UK HP NetServer LH Power Cords Country Australia/New Zealand Canada/United States Denmark Europe HP Part Number 8120-1369 8120-1751 8120-2956 8120-1689 Country India/South Africa Japan Switzerland - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 88
6 - PCI-B Slot 5 - EISA/ISA/PCI-B Control Panel Connector HP Remote Assistant Connector Battery Connectors Power Supply Cable Connectors Flash Rom AIC 7850 2 C Connectors SCSI Port B Connector SCSI Port A Connector HP NetServer LH System Board Connectors, Switches, and Jumpers Connector IDE - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 89
Slot 3 - EISA/ISA Slot 2 - EISA/ISA Slot 1 - EISA/ISA I2C Bus HP NetServer LH Plus / LH Pro System Board Connectors Connector IDE disk drive cable Keyboard Serial A Battery A and B EISA/ISA slots Control panel HP Remote Assistant Connector Battery Connectors Power Supply Cable Connectors SW1 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 90
cable, you need to remove the jumper on PS REMOTE and PS ON. If you remove HP Remote Assistant from the server, remember to re-install the jumper. HP Remote Assistant Connector WARNING If the HP Remote Assistant is not installed and there is no jumper on PS REMOTE and PS ON, the - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 91
disables one of the two levels of flash ROM write protection (the other level of protection is controlled by the HP Update Utility). ON: The BIOS can be updated by the HP Update Utility. OFF: The BIOS is locked and cannot be updated. BOOT BLOCK DISABLE: Reserved. Must be set to ON - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 92
these HP DIMMs are supported: DIMM Type 16 MB DIMM 32 MB DIMM 64 MB DIMM 128 MB DIMM 256 MB DIMM HP Product Number D4294A D4295A D4296A D4297A D4926A • Any combination of DIMMs, listed above, may be used. NOTE The HP warranty does not cover performance problems, equipment problems, or service - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 93
) Reseat the DIMM or Move it to another socket or Replace DIMM N/A (normal) Replace with appropriate HP DIMM or Run Diagnostic Assistant to find the problem Run Diagnostic Assistant to find the problem N/A (normal for non-HP DIMM) Replace with appropriate DIMM or Run Diagnostic Assistant to find the - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 94
Press F7 and select "Lock/unlock boards". Select the PCI board in slot 9 and lock. 6. Exit and save the configuration. Cabling Configurations The HP NetServer comes in two standard models that can be reconfigured by changing the cables. You are not limited to these configurations, but they are given - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 95
Duplex, non-disk array model with internal controller (standard model) External terminator T built into cable IDE C1 Flexible Disk Drive CD-ROM SCSI or IDE Device System Board Internal terminator I2C built into board SCSI B SCSI A C5 C5 T Hot Swap Subsystem Off On UPPER CAGE 1 SCSI ID - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 96
Non-duplex, disk array model with PCI controller board (standard model) or EISA controller board Flexible Disk External terminator T built into cable Drive CD-ROM IDE SCSI or IDE Device System Board Internal terminator PCI/EISA Board built into I2C board SCSI B SCSI A C2 C6 T C4 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 97
Configuring Switch Settings on the Hot Swap Subsystem Switch setting combinations are given in the table below. Off On 1 2 3 4 UPPER 5 CAGE 6 1 2 LOWER 3 CAGE 4 5 6 Switch 1 2 3 4 5 6 Function I2C Bus Setting I2C Bus Setting High/Low Addresses SCSI Address Zero Sets middle shelf - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 98
Hot Swap Subsystem SCSI Address Settings Switches 4 and 6 determine the SCSI address setting for each shelf in the hot swap subsystem. The following table describes the settings and the resulting shelf SCSI address. NOTE For information on changing the SCSI address setting on the CD-ROM drive, see - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 99
HP NetServer LH 3 and LH 3r System Views Front Control Panel Control Description Lock (LH 3 only) Locks system to prevent unauthorized use. DC Power Switchand indicator - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 100
for future use. Scroll down or up. Status LEDs Indicates various types of system status: Green = Normal operation Yellow = Abnormal operation Red = Problem detected Front Panel Menu, as Shown on Status Screen System Information Reports system hardware details and software version numbers. Field - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 101
Rear View Remote Management Port Serial B Port Serial A Port Parallel Port Mouse Port Keyboard Port Monitor Port Power Supplies Power Connector Covers (LH 3) Cover 1 Cover 2 Cover 3 Covers (LH 3r) Cover 2 Cover 1 Cover 3 Cover 1 Cover 2 Cover 3 93 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 102
Memory There are four DIMM sockets on the system board for memory expansion. You can use 64 MB, 128 MB, and 256 MB DIMMs for a maximum capacity of 1 GB of RAM. • The minimum memory configuration for the NetServer LH 3/LH 3r is one 128 MB DIMM. • The system board DIMM sockets are numbered from 0 to - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 103
(VRM) is correctly seated. If problem persists, replace VRM. Secondary VRM Failure Check that secondary VRM is correctly seated. If problem persists, replace VRM. Processor OverTemperature Check ON and OFF at 1 Hz in 90/10 proportion of time: non-HP DIMM installed • ON: HP DIMM installed 95 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 104
Exploded Views 29 30 17 18 15 16 12 13 10 1 30 4 6 5 7 3 96 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 105
2 28 31 32 27 26 29 42 43 44 41 34 38 40 14 41 39 97 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 106
drive cable Floppy cable SCSI (wide) cable, internal 68-50 pin SCSI cable, internal SCSI cable, internal to external Accessory board guide Fans (2), w/accessory board guide assy. Replacement D5000-60001 5064-1996 D5000-63002 5183-3418 Exchange D5000-69000 D5000-69001 1821-4201 1821-4202 1821-4203 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 107
Fig Description Replacement Exchange 28 Fan assembly, rear chassis 5064-3553 29 Fan assembly, power supply 5064-3538 30 Fan assembly, CPU 5064-3531 31 Power supply module, 300W 5064-6603 32 Power supply cage 5064-6605 5064-6604 33 Battery 3V 1420-0356 34a Front panel assembly, - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 108
Power Cords Country Australia/New Zealand Canada/United States Denmark Europe Part Number 8120-1369 8120-1751 8120-2956 8120-1689 Country India/South Africa Japan Switzerland United Kingdom Part Number 8120-4211 8120-4753 8120-2104 8120-1351 Hot-Swap Hard Disk Drive LED Status and Activity - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 109
OFF OFF OFF 2 OFF OFF ON ON 3 ON ON OFF OFF 4 OFF ON OFF ON Note: Only processor speeds for the 100 MHz bus are supported. 101 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 110
Specifications Operating Temperature Non-operating Temperature Operating Humidity Non-operating Humidity Operating Altitude Non-operating Altitude Minimum Clearance Front Sides Top Back Weight and Dimensions Height Width Depth Weight 5°to 35°C (41°to 95°F) -40° to +65° C (-40° to +149° F) 20% to - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 111
LH 4 and LH 4r System Information System Views HP NetServer LH 4 (Pedestal) HP NetServer LH 4r (Rack-Optimized) Front Control Panel Control Description Lock (LH 4 only) Locks system to prevent unauthorized use. DC Power Switchand indicator light Turns - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 112
for future use. Scroll down or up. Status LEDs Indicates various types of system status: Green = Normal operation Yellow = Abnormal operation Red = Problem detected Front Panel Menu, as Shown on Status Screen System Information Reports system hardware details and software version numbers. Field - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 113
Rear View Remote Management Port Serial B Port Serial A Port Parallel Port Mouse Port Keyboard Port Monitor Port Power Supplies Power Connector Covers (LH 4) Cover 1 Cover 2 Cover 3 Cover 2 Cover 1 Cover 3 105 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 114
Covers (LH 4r) Cover 1 Cover 2 Cover 3 Memory The two memory boards (Memory A and Memory B) are located on the system board assembly, beneath the memory cage cover. Both memory boards are required. Each board has slots for eight DIMMs. The following rules must be observed when adding memory: DIMMs - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 115
port Mouse port Keyboard port Monitor port VRM 1 VRM 2 Note: Processor slots without processors have terminators. NOTE Use only HP DIMMs listed in HP Information Assistant or HP Order Assistant. Keys Notches Keys Latches CAUTION Do not rock the DIMM into place, but apply firm and even - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 116
The Boot Device Ordering submenu contains the following options: • Floppy check: Enables or disables verification of flexible disk drive type during boot • Summary screen: Enables or disables display of a screen of system configuration information. • Boot Device Priority: Allows you to rearrange the - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 117
19 30 17 18 15 16 12 13 10 2 28 31 32 27 26 29 109 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 118
42 43 44 41 34 38 40 14 41 Parts List NOTE 39 These part numbers are the numbers available at the time of publication. Part numbers may be revised after the publication date. Fig 1 2 3 4 5a 5b 6 7a 7b 8 9 10 11 Description System board PCA (PCA only) I/O PCA Memory PCA Backplane PCA Pentium - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 119
, 10,000 rpm (hot-swap use) 18.2 GB half-height Ultra2 drive, 7200 rpm (hot-swap use) 1.44MB 3.5" floppy drive Accessory board guide Fans (2), w/accessory board guide assy. Fan assembly, rear chassis Fan assembly, power supply IDE CD ROM drive Power supply module, 300W Power supply cage Front panel - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 120
Fig Description Replacement Exchange * Floppy cable 5183-3443 * SCSI (wide) cable, internal 68-50 pin 5183-3444 * SCSI cable, internal 5183-3445 * SCSI cable, internal to external 5183-3446 * Battery 3V 1420-0356 * Installation handles, rack version (4) 5002-5191 * Rails for - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 121
Hot-Swap Hard Disk Drive LED Status and Activity Indicators Each hot-swap hard disk drive module has two LED apertures on its front, one for power status and one for activity status. System Board VRM 3/4 Memory Board B Memory Board A VRM 1/2 Activity Status LED Aperture Power Status LED Aperture - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 122
off Processor Speed: 400 450 500 Switch 2: ON OFF ON Switch 4: ON ON OFF Note: Only processor speeds for the 100 MHz bus are supported. Cabling R1 Remote Management Rear Panel 1 2 I/O Board C73 SCSI knockouts Control Panel C72 SE SCSI A Optional SCSI NonHot-Swap Device SCSI B C65 SCSI - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 123
Cables and Part Numbers Cable C62 C63 C64 C65 C72 C73 D7 F7 P2 P3 R1 Description Part Number Internal SCSI (Wide) LVD Cable (SCSI A to Primary Mass Storage) 5183-3444 Internal SCSI (Wide) LVD Cable (DAC to Primary Mass Storage)* 5183-6527 Internal SCSI (Wide) LVD Cable (DAC to Secondary Mass - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 124
Height Width Depth Weight 494.8 mm (19.5 in) 350.5 mm (13.8 in) 724.2 mm (28.5 in) 35 - 50 kg (77 - 110 lb) Weight and Dimensions - LH 4r Height Width Depth Weight 354.7 mm (14 in) 482.6 mm (19 in) 749.2 mm (29.5 in) 36 - 60 kg (79 - 132 lb) Power Supply Power supply input voltage Power supply - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 125
HP NetServer LM System Views Front and Rear Views Control Panel Re se t 1 2 Shelf 1 Mass -in video External SCSI Port The server was pre-set at the factory for the AC line voltage in each supported country. If the AC voltage is between 100-127 VAC, the AC line select switch should be set at the - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 126
Control Panel Power-on Light Power Button Reset Button Hard Disk Activity 1 Hard Disk Activity 2 Keyboard Lock Light Keyboard Lock LCD Exploded View 1 2 4 3 5 118 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 127
2 16 15 14 17 13 12 9 6 7f 10 7 8 11 119 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 128
List NOTE The part numbers in the list were the ones that were available at the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the revised part number. If a system board needs to be replaced, any video DRAM chips - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 129
D2186-40001 D2194-40001 C3304-60150 C3305-60150 C3306-60150 5181-7756 C3310-60017 C3310-60009 D2332-13014 D2992-63002 D2332-60008 D2993-69003 HP D2198A HP D2199A Exchange C3304-69150 C3305-69150 C3306-69150 D2992-69002 D2993-63003 C3310-69124 C3304-69150 C3305-69150 C3310-60009 C3310-60130 C3310 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 130
Number 8120-1369 8120-1751 8120-2956 8120-1689 System Board Country India/South Africa Japan Switzerland United Kingdom HP Part Number 8120-4211 8120-4753 8120-2104 8120-1351 Video memory DRAM sockets IDE connector Power supply Power supply Control panel connectors enable connector - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 131
System Board Jumper Locations E0722 E0721 3 2 E0720 1 E0392 E0391 E0390 E0292 E0291 E0290 E0190 System Board Jumper Settings Jumper E0190 E0290 E0291 E0292 E0390 E0391 E0392 Function Flash BOOT. When the jumper is on pins 1 and 2, the Flash ROM can be reflashed. If the Flash ROM is corrupt - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 132
update diskette will contain complete instructions. Leave the BIOS jumper in the DISABLED position unless the HPUpdate Utility instructions direct you to change the upgrade. Consult the HP PC Bulletin Board Service at 1-408-553-3500 for a current list of supported DRAM upgrades. Recommended Video - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 133
TMS44C256N-60 To take advantage of the upgrade, you must also install the appropriate drivers. Consult the HP PC bulletin board for a list of the required drivers. Hewlett-Packard does not supply or support the drivers. CAUTION Apply gentle pressure on the pins. They can bend easily. If a pin - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 134
Config with the new .CFG file. Selecting Primary SCSI Channel Starting with the HP NetServer #1 diskette, version F.01.00, you may select Channel A (external) recognized by the network operating system (NOS). The default configuration of the HP SCSI 535 MB, 1 GB, and 2 GB hard disk drives has - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 135
section in the hard disk Installation Guide). The result of this procedure is drive has spun up. Boot Problem with Greater than 2 GB HP Disk Array Boot Drive An array HP Fast SCSI-2 Kit (C3607A). The kit contains an active terminator, driver software, and installation instructions to support the HP - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 136
In the EISA Configuration Utility, select the Hard Drive 1 (or 2) to be Drive Type 2 or 48 (User Definable) at the end of the list of choices for any IDE hard disk drives installed. Do not use Hard Disk Auto Configuration. Verify these parameters as the drive definition: Parameter 240 270 MB MB - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 137
HP NetServer LPr System Views Front Panel Controls CD-ROM Drive Drive Activity LED Reset Switch Power ON/OFF LED Power On/Off Switch Drive Error - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 138
specific drive LEDs and determine which device is in trouble. LED flashes red when any one of several and then power down the system and correct the fan problem. This indicator reports on the power supply fan as well LPr network adapter is supporting transfers at the 100 mbps (million bits per second) - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 139
In-Line Memory Modules). The NetServer LPr ships with at least 64 MB of main memory and supports up to 1 GB. Memory is available in the following DIMM capacities: 64, 128, and in numerical order: 1, 2, and 3. Use only HP DIMMs. System Board DIMM Socket 0 DIMM Socket 1 DIMM Socket 2 DIMM Socket 3 131 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 140
frame buffer to 2 MB to support 1280 x 1024 by adding two memory chips. NOTE The video memory chips must be installed in pairs. To get a higher resolution display, you may have to load additional video drivers for the operating system. Refer to the instructions that accompanied the video memory - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 141
Hot-Swap Drive Bay Addresses SCSI ID 1 SCSI ID 0 Accessory Boards The HP NetServer LPr includes four PCI slots; one (over the system board) is taken before using slot #3. NOTE Adding a PCI-to-PCI bridge card to the HP NetServer may alter the server's boot order. This boot order can be changed - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 142
it into the slot. Check to make sure you removed any handles or board extenders. Remote Control Card Refer to the Top Tools Administration Guide for Remote Control along with the upgrade kit documentation for information on the remote control card. Route cable through open spaces to PCI area. DO - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 143
HP NetRAID Card NOTE If there are other SCSI controllers on the PCI bus, the slot will affect boot order. See the Boot Device Priority. SCSI Cable SCSI Repeater Card HP NetRAID Adapter SCSI Cable 135 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 144
I/O Board SCSI Cable Connector Embedded SCSI Connector Terminator Block 136 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 145
Processor Module NOTE Be sure that the VRM and the processor module associated with it are both in primary or secondary slots. New processors are added. See the Technical Reference Card for the latest switch settings. Secondary Processor VRM Slot Secondary Processor Module Slot Primary Processor - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 146
Processor Module Do not touch VRM components VRM Secondary VRM Slot Secondary Processor Slot NOTE Be sure that the VRM and the processor module associated with it are both in primary or secondary slots. Exploded Views 138 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 147
Parts List * This part is not on an exploded view. Fig Description 1 Top Cover 2 I/O ("Riser") Board 3 Fan pack 4 SCSI backplane 5 SCSI management board 6 Hot-swappable SCSI drive Hot-swappable drive kit 7 Hot-swap bay filler panel 8 Floppy disk drive 9 Control panel 10 CD-ROM drive, - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 148
memory 18 Network adapter card (NIC) 19 Rear panel 20 SCSI terminator 21 PCI stabilizer 22 PCI access door 23 Power supply 24 Bezel kit (HP pictured) Bezel kit, 3rd party 25 System board Cables Cable SCSI Terminator Power I2C Management Port IDE, CD-ROM Control panel Floppy drive SCSI AC - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 149
System Board Illustration Processor Module Processor Module Slot #2 Voltage Regulator Slot #1 Module #2 Slot Voltage Regulator Module #1 Slot Battery Processor Module DIMM Slot 0 DIMM Slot 1 DIMM Slot 2 DIMM Slot 3 Additional Video Memory Sockets Serial B Port Connector Serial A Port - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 150
-30 to 3,000 m (~ 10,000 ft) -30 to 12,000 m (~ 40,000 ft) Thermal Output Maximum Operating 1041 BTU/hr Minimum Clearance No requirement in HP racks. Weight and Dimensions Weight Width Depth Height Approx. 40 lbs (88 kg)., depending on configuration 17.6 inches (44.7 cm) 28 inches (71.1cm - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 151
HP NetServer LS System Views Front View Cover keylock Key bag Rear View 143 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 152
keyboard is locked. Displays the Power-On Self-Test (POST) or system messages. Control Panel Connector J1 This connector is used by the HP Remote Assistant Accessory, a 32-bit EISA Bus Master board used to remotely monitor server functionality. For additional information on this product, see the - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 153
Mass Storage Indicator Lights Control Panel J1 For some SCSI controller boards, you must connect the hard disk activity light. 145 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 154
Hard disk activity light 1 connector Hard disk activity light 2 connector Cover CAUTION The cover is an integral part of the NetServer. The NetServer must be operated with the cover in place to ensure proper airflow for continued reliability and to maintain compliance with radio frequency - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 155
Exploded Views 1 2 9 13 12 10 14 11 4 3 5 15 19 18 17 16 6 7 8 147 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 156
25 26 1 27 20 21 22 23 24 1 33 28 32 29 30 31 148 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 157
the time of publication. Part numbers may change after publication. HP's parts price list database will generally contain a reference to the MB 3.5" Flexible Disk Drive 20 LS System Board 21 HP SCSI PCI Controller Board 22 PCB Support Rail Replacement not orderable 5063-5671 5063-5672 5041-1099 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 158
5635 29 Chassis Foot 5041-1082 30 Fan Assembly 3160-1004 31 Card Guide Plastic Assembly 5041-6342 32 LS Control Panel PCA 5064-0739 33 LS * Video DRAM ** 5182-9404 * LS SCSI Cable Kit D3330-60010 * HP Navigator CD-ROM*** 5063-8346 * Diagnostic Assistant Diskette 5011-1941 * This - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 159
Storage Cables If you need additional cables, the cables are not available separately, but only by ordering the HP Cable Kit Part Number D3330-60010. Only the following HP cables and adapter are supported: Cabling Label C1 C2 C3 C4 C5 A Cable Narrow SCSI (50 pin) cable with built-in terminator - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 160
System Board IO Panel Connectors Side view Keyboard Mouse Serial port B Serial port A Parallel port LPT1 Monitor Flexible Disk 1.44 MB Power Control Enable Disable Boot Block Disable E n ab le Program Boot Block Disable E n ab le Video Sleep REG 46E8 REG 3C3 Video DRAM Upgrade PCI 1 PCI 2 Shared - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 161
Video Sleep - Determines which I/O port the onboard Cirrus Logic super VGA controller uses for its internal AT mode setup port. Program Boot Block - lets a qualified service technician update the boot block. Not used Not used Disabled Disabled Not used REG 3C3 Disabled 153 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 162
SIMMs within a bank must be the same size. Bank 3 Bank 2 Bank 1 Bank 3 Bank 2 Bank 1 When installing additional memory, note the following: • The following HP SIMMs are supported: Type 4 MB SIMM (70 ns) 8 MB SIMM (70 ns) 16 MB SIMM (70 ns) 32 MB SIMM (70 ns) Product Number D2974A D3577A D2297A - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 163
. Increasing the video memory buffer size to 1 MB with a 256 K x 16 (512 KB), 70 ns, 40-pin SOJ package DRAM allows the controller to support 132-column text modes and high resolution graphics. Boot Device Priority If you are installing a SCSI controller board, the priority of the controllers (where - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 164
Duplex, non-disk array model with internal controller (standard model) External terminator T built into cable IDE C1 Flexible Disk Drive CD-ROM SCSI or IDE Device System Board Internal terminator I2C built into board SCSI B SCSI A C2 C2 T Hot Swap Subsystem Off On UPPER CAGE 1 SCSI ID - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 165
Non-duplex, disk array model with PCI controller board (standard model) Flexible Disk External terminator T built into cable Drive CD-ROM IDE C1 SCSI or IDE Device 68 to 50 pin adapter A T System Board Internal C2 terminator built into I2C board PCI Board SCSI B SCSI A C3 C2 C2 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 166
to upper eight SCSI addresses. Note: this setting may cause time-out problems with your NOS due to delayed start. Off Sets drives to lower eight Power-on sequence is determined by the disk array controller. Not supported by HP SCSI controller boards. 6 Upper/Lower Cage On Lower cage Identifies - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 167
Hot Swap Subsystem SCSI Address Settings Switches 3, 4, and 6 determine the SCSI address setting for each shelf in the hot swap subsystem. The following table describes the settings and the resulting shelf SCSI address. NOTE For information on changing the SCSI address setting on the CD-ROM drive, - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 168
- HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 169
Notes 161 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 170
162 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 171
163 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 172
164 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 173
Index 1 1740 Host Adapter LM, 126 A altitude LC, 11 LD, 43 B battery LE, 48 boot from a PCI controller board LH, 86 from an EISA controller board LH, 86 from an ISA controller board LH, 86 BOOT BLOCK DISABLE LC, 4 LD, 31 LF, 61 LH, 83 LS, 153 boot device priority LC 3, 16 LD, 34 LH, 86 LH3, 94 LH4, - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 174
subsystem switch settings LS, 158 HP C2260A Storage System, 127 HP Disk Array 2 GB disk LM, 127 HP NetRAID Card LPr, 135 HP NetServer LC exploded view, 8 HP NetServer LD exploded view parts HP NetServer LE exploded view, 47 HP NetServer LF exploded view, 55 HP NetServer LH Plus exploded view, 71 - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 175
J J22 LH, 82 J25 LH Plus/LH Pro, 82 jumpers LC J7, 4 LF CPU Type, 58 LF CPU voltage select, 58 LF Intel 486 processor board LF, 58 LF J6, 60 LM default settings, 123 LM location, 123 jumpers and connectors LC system board, 2 LD system board, 29 LE, 50 LF, 60 LH system board, 80 jumpers LM Clear - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 176
LS, 159 P parallel port LM connector location, 117 part numbers LC, 8 LC keyboards, 10 LC power cord, 10 LD, 41 LD keyboards, 43 LD power cord, 43 LE, 47 LE keyboards, 48 LE power cords, 49 LF, 57 LF keyboards, 58 LF power cords, 58 LH, 69 LH keyboards, 79 LH Plus, 73 LH power cord, 79 LH Pro, 76 LM - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 177
LH4, 105 Remote Control Card LPr, 134 Reset Button LS, 144 S SCSI HP C2260A Storage System, 127 LM BIOS address, 126 LM external port location, 117 LM Host Adapter Configuration, 126 LM installing four or more disk drives , - HP D5970A | HP Netserver Service Handbook, Volume 2 - Mid - Page 178
LD, 43 LF operating, 62 LH, 90 LH3, 102 LH4, 115 LM operating, 128 operating LE, 52 Temperature LPr, 142 V video LC installing DRAM, 7 LE type of DRAM needed, 51 LF installing DRAM, 62 LM connector location, 117 LM installing DRAM, 124 video controller LS, 155 VIDEO Enable switch LC, 5 LD, 32 LF,
![](/manual_guide/products/hewlettpackard-lh3000r-hp-netserver-service-handbook-volume-2-mid-c2e969e/1.png)
HP NetServer Product Line
Service Reference Guide
Volume 2
Mid-Range
Version 2
Last Updated: