- HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 1
HP NetServer LPr Installation Guide for Compaq® 4000/7000 Racks HP Part Number 5967-6635 Printed in October 1998 - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 2
USA © Copyright 1998, Hewlett-Packard Company. Audience Assumptions The user guide is for the person who installs, administers, and troubleshoots network servers. Hewlett-Packard Company assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 3
...3 HP NetServer LPr - Compaq Rack Precautions 5 2 Overview ...7 3 Installation ...7 Preparation ...7 Marking the Installation Holes 7 Installing the Rack Nuts 8 Mounting the Rails 9 Installing the NetServer 11 Installing the Bezel 13 4 Warranty and Support 17 HP Repair and Telephone Support - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 4
- HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 5
or 7000-series rack enclosure. Refer to the HP NetServer LPr Installation Guide that came with the NetServer for instructions on adding accessories to and configuring the NetServer. The HP NetServer LPr is shown in Figure 1-1. Figure 1-1. HP NetServer LPr WARNING To prevent the rack from tipping - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 6
Introduction at the front of the base of the enclosure and, if you are installing this NetServer in a single rack enclosure, two "feet" each on the left and right sides of the enclosure (see Figure 1-2). Side Stabilizing "Feet" (Both Sides) Front Stabilizing " - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 7
not installed according to these instructions, damage to the NetServer or accessories may result. Damage due to improper installation is not covered by the HP Warranty. Observe the precautions listed in this section to maintain the NetServer's reliability. When the HP NetServer LPr is installed in - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 8
- HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 9
Introduction 2 Overview The steps required to install the NetServer in the rack are summarized below: NOTE This is only a summary; detailed instructions are provided on the following pages. • Measure and mark the appropriate holes on all four rack columns. • Install three rack nuts on each of - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 10
Installation - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 11
section contains detailed instructions for installing an HP NetServer LPr in certain models of Compaq rack enclosures. Preparation Before beginning the installation of the NetServer into the rack, you must prepare the rack and the NetServer. Determine the location at which the NetServer is to be - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 12
Rear Of Column) 5th 3rd 2nd 5th 3rd 2nd Template (optional) Unit Below Intended Installation Location Figure 3-1. Marking Holes For Installation To mark the NetServer mounting holes on the front columns (refer to Figure 3-1), count up from the top of the unit below, marking the 2nd and 5th holes - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 13
Rack Column Installation Rack Nut Figure 3-2. Installing Rack Nuts Mounting the Rails 1. Slide the two halves of each rail together (see Figure 3-3). Use either rail in either location; they are identical. 9 - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 14
Installation Figure 3-3. Rail Assembly 2. Position a rail so that the mounting flanges align with the installed rack nuts (see Figure 3-4). Do this at the front and rear columns. 3. Insert a screw in the second hole from the bottom of each flange and tighten the screw. 4. Repeat for the other rail. - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 15
Figure 1-2). 1. Remove the hot-swap disk modules from the NetServer before lifting it into the rack enclosure. WARNING Use two people when moving the NetServer or lifting it into the rack. 2. Using two people, lift the NetServer and move the NetServer in between the rails. Slide it all the way - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 16
Installation Figure 3-5. Lifting the Server Onto the Rail Members 12 - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 17
the rack nuts in the columns (previously installed). Figure 3-6. Securing the NetServer to the Rack Columns 4. Replace the hot-swap disk modules into the NetServer. Installing the Bezel This NetServer ships with bezel anchors for use with an HP-rack bezel. In order to install the bezel for use with - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 18
Installation Figure 3-7. Removing the Bezel Anchors from the NetServer 2. Attach the bezel anchors to each side of the NetServer front panel using two screws (see Figure 3-8). Figure 3-8. Attaching the Compaq-Rack Bezel Anchors to the NetServer 14 - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 19
Installation 3. Attach the bezel for use with the Compaq rack to the NetServer (see Figure 3-9). Figure 3-9. Attaching the Compaq Bezel to the NetServer 15 - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 20
- HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 21
that the NetServer has adequate cooling airflow and proper temperature control to maintain system reliability. HP Repair and Telephone Support Refer to the Service and Support chapter of your HP NetServer system documentation for instructions on how to obtain HP repair and telephone support. 17 - HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 22
- HP D5970A | Installation Guide for Compaq 4000/7000 Racks - Page 23
Index C Compaq, 1 D door, rack enclosure, 3 E EIA, 5 L lifting server into rack, 11 P precautions, 3 R rack, 5 rack enclosure, 5 rack nut, 5 rail, 5 location, 7 mounting flange, 5 T template, 7 19
HP NetServer LPr
Installation Guide
for
Compaq
®
4000/7000 Racks
HP Part Number 5967-6635
Printed in October 1998