    HP NetServer LH 3r, LH 4r, LH 3000r, and LH 6000r Installation Guide for Compaq® 4000/7000 Racks HP Part Number 5969-5924 Printed in November 1999
  • HP D5970A | Installation Guide for Compaq Racks - Page 2
    USA © Copyright 1999, Hewlett-Packard Company. Audience Assumptions The user guide is for the person who installs, administers, and troubleshoots network servers. Hewlett-Packard Company assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products
  • HP D5970A | Installation Guide for Compaq Racks - Page 3
    10 Installing the NetServer 12 Mounting the NetServer to the Slides 12 Optional for HP NetServer LH 3000r and LH 6000r, Install Cable Management Arm 16 Installing the Recessed Mounting Brackets 18 Relocating the Control Panel 19 Installing the Bezel 22 4 Warranty and Support 23 Hardware
  • HP D5970A | Installation Guide for Compaq Racks - Page 4
  • HP D5970A | Installation Guide for Compaq Racks - Page 5
    4r, LH3000r, or LH 6000r into a Compaq® model 4000- or 7000-series rack enclosure. Refer to the documentation that came with the HP NetServer for instructions on adding accessories to, and configuring the NetServer. The HP NetServer LH 3r, LH 4r, LH3000r, or LH 6000r (the pedestal versions of this
  • HP D5970A | Installation Guide for Compaq Racks - Page 6
    front of the rack enclosure. Be sure that the stabilizing, anti-tip feature is installed on the rack enclosure in which you are installing the HP NetServer. This option consists of two "feet" at the front of the base of the enclosure and, if you are installing this
  • HP D5970A | Installation Guide for Compaq Racks - Page 7
    Chapter 1 Introduction Figure 1-2. Single Rack Enclosure with the Anti-Tip Stabilizing Feature Installed 3
  • HP D5970A | Installation Guide for Compaq Racks - Page 8
    according to these instructions, damage to the NetServer or accessories may result. Damage due to improper installation is not covered by the HP Warranty. Observe the precautions listed in this section to maintain the NetServer's reliability. When installing this HP NetServer in a Compaq rack
  • HP D5970A | Installation Guide for Compaq Racks - Page 9
    swap drives from the NetServer. • Lift the NetServer onto the slides. • Secure the NetServer to the slides. • Remove the lifting handles from the NetServer. • Reinstall the power supply modules and hot-swap drives. • Push the NetServer back into the rack enclosure. • For HP NetServer LH 3000r and LH
  • HP D5970A | Installation Guide for Compaq Racks - Page 10
    individual nuts to mate with slide mounting screws. Removable plastic fascia panel that covers entire front of the NetServer. This NetServer includes two bezels: one for installation in HP rack enclosures, and one for installation in Compaq 4000/7000 series rack enclosures. Display and buttons used
  • HP D5970A | Installation Guide for Compaq Racks - Page 11
    3 Installation This section contains detailed instructions for installing an HP NetServer NetServer LH 3r, LH 4r, LH 3000r, or LH 6000r in the model 4000/7000 series of Compaq rack enclosures. Preparation Before beginning the installation of the NetServer into the rack, you must prepare the rack
  • HP D5970A | Installation Guide for Compaq Racks - Page 12
    columns to use for rack nuts where the two recessed mounting brackets attach to the columns. When the installation is complete, these brackets secure the NetServer in the rack enclosure. To mark the bracket mounting holes refer to Figure 3-1: 1. On the left front column, count up from the top of the
  • HP D5970A | Installation Guide for Compaq Racks - Page 13
    Chapter 3 Installation Installing the Bar Nuts, Screws, and Cage Nuts Once you have marked the appropriate holes, install the bar nuts and screws on the columns: 1. Position one bar nut behind holes 20 and 22 (previously marked). 2. Insert the two screws, with flat washers, through the two holes
  • HP D5970A | Installation Guide for Compaq Racks - Page 14
    Chapter 3 Installation Mounting the Slides 1. Orient each slide so that the front of the slide attaches to the front column and the rear attaches to the rear column. This ensures that once installed, the slides will extend correctly, toward the front of the rack see Figure 3-3. NOTE The slides
  • HP D5970A | Installation Guide for Compaq Racks - Page 15
    the screws. Tightening the screws without lifting up on the slides will result in interference between the HP NetServer and other equipment in the rack; you may not be able to slide the HP NetServer into the rack enclosure after completing the installation. 6. Repeat for the other slide. 11
  • HP D5970A | Installation Guide for Compaq Racks - Page 16
    66 kg) after the hard disk drives and power supply modules are removed. The HP NetServer LH 3000r weighs approximately 118 pounds (54 kg) after the hard disk drives and power supply modules are removed. The HP NetServer LH 6000r weighs approximately 148 pounds (67 kg) after the hard disk drives and
  • HP D5970A | Installation Guide for Compaq Racks - Page 17
    Chapter 3 Installation 3. Using two people, lift the NetServer using the handles on each side. Move the NetServer in between the extended slide members and position the it so that the handles are resting on the slide members see Figure 3-5 and Figure 3-6. Figure 3-5.
  • HP D5970A | Installation Guide for Compaq Racks - Page 18
    Chapter 3 Installation 4. Line up the mounting holes in the slide members with the holes in the NetServer chassis, insert three screws on each side, and tighten them see Figure 3-6. Figure 3-6. Attaching the Slides to the Server Chassis 14
  • HP D5970A | Installation Guide for Compaq Racks - Page 19
    each of the four handles and remove handles see Figure 3-7. Keep these handles and screws for later use, in case you need to remove the NetServer and ship it. Figure 3-7. Remove Mounting Handles 6. Reinstall power supply modules and hard disk modules removed earlier. 15
  • HP D5970A | Installation Guide for Compaq Racks - Page 20
    you install the cable management arm, remove and discard the rear door from the Compaq rack. 1. Ensure that the HP NetServer is pushed all the way into the rack. 2. At the rear of the NetServer, place cage nuts on the left column in the 17th and 18th holes above the baseline of the
  • HP D5970A | Installation Guide for Compaq Racks - Page 21
    up with the rack nuts previously mounted on the rack columns. 10. Plug the HP NetServer's power cable and all available data cables into the back of the HP NetServer. Refer to the rack assembly and cabling reference guide for your HP NetServer, for information about cable dressing and routing. 17
  • HP D5970A | Installation Guide for Compaq Racks - Page 22
    brackets. These are attached to the face of the NetServer chassis and the two front rack columns. To install these brackets: 1. On both slide members, simultaneously depress the lockout releases and push the NetServer completely into the rack enclosure see Figure 3-9. Lockout Release Figure
  • HP D5970A | Installation Guide for Compaq Racks - Page 23
    and to the rack column see Figure 3-10. 3. Install the four screws that hold the short, right-hand bracket to the face of the NetServer chassis and to the rack column see Figure 3-10. Recessed Brackets Figure 3-10. Installing the Recessed Mounting Brackets Relocating the Control Panel The control
  • HP D5970A | Installation Guide for Compaq Racks - Page 24
    damaging the ribbon cable, verify that the ribbon cable goes completely back inside the NetServer before mounting the control panel. NOTE There are two possible locations for the control racks (on left) Mounting Slots for HP racks (on right) Control Panel Figure 3-11. Relocate the Control Panel 20
  • HP D5970A | Installation Guide for Compaq Racks - Page 25
    Chapter 3 Installation 6. Mount the control panel bezel over the control panel see Figure 3-12. Install the bezel tabs into the leftmost slots. Mounting Slots for Compaq racks (on left) Mounting Slots for HP rack (on right) Figure 3-12. Reinstall the Control Panel Bezel 21
  • HP D5970A | Installation Guide for Compaq Racks - Page 26
    Chapter 3 Installation Installing the Bezel Align the locating tabs on the Compaq rack-compatible bezel with the holes in the NetServer front panel, and clip the bezel onto the front of the NetServer see Figure 3-13. Figure 3-13. Installing the Compaq Rack-Compatible Bezel 22
  • HP D5970A | Installation Guide for Compaq Racks - Page 27
    to components purchased as accessories. If your component was factory installed as part of a HP NetServer model, refer to the HP NetServer Warranty and Service/Support Booklet for the warranty limitations, customer responsibilities, and other terms and conditions. Hardware Accessories Limited
  • HP D5970A | Installation Guide for Compaq Racks - Page 28
    system processor unit (such as LAN cabling)-are subject to standard per-incident travel and labor charges. HP Repair and Telephone Support Refer to the Warranty and Service/Support Booklet supplied with your HP NetServer system documentation for instructions on how to obtain HP repair and telephone
  • HP D5970A | Installation Guide for Compaq Racks - Page 29
    server into rack, 13 Lockout releases, 18 M Mounting Brackets, 18 Mounting, NetServer, 12 N NetServer, installing, 12 R Recessed brackets, attaching, 19 S Slide location, 7 Support, 24 V Version of NetServer, 1 W Warning reduce lifting weight, 12 Warranty hardware accessories limited, 23 25
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29

HP NetServer LH 3r, LH 4r,
LH 3000r, and LH 6000r
Installation Guide for
Compaq
®
4000/7000 Racks
HP Part Number 5969-5924
Printed in November 1999