HP EVA P6000 HP Controller Enclosure Cache DIMM Replacement Instructions (5930
HP EVA P6000 Manual
View all HP EVA P6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP EVA P6000 manual content summary:
- HP EVA P6000 | HP Controller Enclosure Cache DIMM Replacement Instructions (5930 - Page 1
(gray)-colored latches on components like the controller means the component is warm-swappable. Halt the I/O of a controller being serviced with HP P6000 Command View before removing this component. • There are two controllers at the rear of the controller enclosure. See Figure 1 for the locations - HP EVA P6000 | HP Controller Enclosure Cache DIMM Replacement Instructions (5930 - Page 2
to verify component failure: • Analyze any failure messages received. HP Insight Remote Support Software provides a recommended fault monitoring solution. • Check status using HP P6000 Command View: 1. In the navigation pane, select Storage system > Hardware > Controller enclosure and then select - HP EVA P6000 | HP Controller Enclosure Cache DIMM Replacement Instructions (5930 - Page 3
the DIMM socket (1, Figure 7). Figure 4 Removing the controller cover . 5. Figure 5 shows the location of the two DIMMs on the controller. Figure 7 Installing a DIMM . 2. Press the retaining clips inward to lock the DIMM into the socket (2, Figure 7). 3. Place the cover on the controller module - HP EVA P6000 | HP Controller Enclosure Cache DIMM Replacement Instructions (5930 - Page 4
b. Attach the Fibre Channel and/or SAS (if applicable) cables to the controller. c. Fully insert the controller. Move the mounting If not, try reseating the controller in the enclosure. • From HP P6000 Command View, navigate to the component as described in the Verifying component failure section
HP Controller Enclosure Cache
DIMM Replacement Instructions
© Copyright 2009 Hewlett-Packard Development Company, L.P.
Second edition: May 2011
The information in this document is subject to change without notice.
Printed in Puerto Rico
www.hp.com
*593091-001*
About this document
For the latest documentation, go to
h
t
tp://w
w
w
.hp
.co
m/su
ppo
r
t/
man
uals
, and select your product.
The information contained herein is subject to change without notice.
The only warranties for HP products and services are set forth in the
express warranty statements accompanying such products and services.
Nothing herein should be construed as constituting an additional
warranty. HP shall not be liable for technical or editorial errors or
omissions contained herein.
WARRANTY STATEMENT:
To obtain a copy of the warranty for this product, see the warranty
information website:
h
t
tp://w
w
w
.hp
.co
m/go/s
t
o
r
age
w
ar
r
an
t
y
Before you begin
Observe the following precautions when replacing the cache DIMMs
on a controller.
CAUTION:
HP recommends that you perform the replacement procedure
within seven minutes. Ensure all necessary parts are available
so the procedure can be completed without interruption.
Removing a controller module significantly changes the air flow
within the enclosure. Both controllers must be installed for the
enclosure to cool properly. If a controller fails, leave it in place
in the enclosure until a new module is available to install. The
enclosure could shut down due to overheating unless the
controller is replaced within the recommended seven minutes.
Parts can be damaged by electrostatic discharge. Use proper
anti-static protection. Refer to the documentation that shipped
with your system for additional information.
•
Alloy (gray)-colored latches on components like the controller means
the component is warm-swappable. Halt the I/O of a controller being
serviced with HP P6000 Command View before removing this com-
ponent.
•
There are two controllers at the rear of the controller enclosure. See
Figure 1
for the locations.
•
Your controller enclosure model may vary slightly from what is illus-
trated in this document.
2. Controller 2
1. Controller 1
Figure 1 Controller locations
.
Page 1