HP Indigo WS6000 Rewinder Calibration

HP Indigo WS6000 Manual

HP Indigo WS6000 manual content summary:

  • HP Indigo WS6000 | Rewinder Calibration - Page 1
    how to calibrate the rewinder for high-sensitivity film substrates. Scope HP Indigo WS6000p Digital Press, HP Indigo WS6600 Digital Press, HP Indigo WS6800 Digital Press, HP Indigo WS6000p Digital Press, HP Indigo WS6600p Digital Press Document number CA393-09450 Revision number Rev00 Date 11
  • HP Indigo WS6000 | Rewinder Calibration - Page 2
    Table of contents 1 Overview ...1 2 Procedure ...2 Appendix A Revision history and confidentiality notice ...8 Revision History ...8 Confidentiality notice...8 ii
  • HP Indigo WS6000 | Rewinder Calibration - Page 3
    the rewinder may not be appropriate for high-sensitivity film substrates. When encountering problems with blocking or ink back-transfer on the finishing line, it is necessary to calibrate the rewinder for the specific substrate. The procedure below describes how to calibrate the rewinder. Overview 1
  • HP Indigo WS6000 | Rewinder Calibration - Page 4
    2 Procedure Follow these steps to calibrate the rewinder for high-sensitivity film substrates. 1. Open the rear door of the rewinder. 2. Access the pressure regulator for the substrate tension. 2 Chapter 2 Procedure
  • HP Indigo WS6000 | Rewinder Calibration - Page 5
    3. From the press software, go to: Main Menu > Substrate > Substrate List. 4. Select the substrate and go to: Properties > Edit > Advanced. 5. Select the Rewinder tension box and enter 0.5 in the Range window. 6. Select OK in the Range window and OK in the Advanced window. Procedure 3
  • HP Indigo WS6000 | Rewinder Calibration - Page 6
    7. Run the substrate for a few meters by pressing on the green button on the rewinder operation screen. 4 Chapter 2 Procedure
  • HP Indigo WS6000 | Rewinder Calibration - Page 7
    8. After running the substrate, read regulator display from the pressure regulator at the rear of the rewinder. Open the attached Excel file and record the regulator display in the orange column for 0.5 kg tension. Table 2-1 Regulator Pressure (Table 1) UI - RW tension [kg] Desired Regulator
  • HP Indigo WS6000 | Rewinder Calibration - Page 8
    sheet. The blue line represents the desired values and the orange line represents the current Regulator pressure vs. rewinder tension. 11. Unlock the pressure regulator: press the leftmost button and hold it for 3 seconds (the display will show unL) and then
  • HP Indigo WS6000 | Rewinder Calibration - Page 9
    in Excel Table 1 for 3 kg. 18. Repeat Steps 13-18 until the blue and orange lines meet at the 3 kg line. 19. Return to the press UI and set the tension for 0.5 kg. 20. Repeat Steps 11-17 for F1 and P1, until the blue and orange lines meet at the
  • HP Indigo WS6000 | Rewinder Calibration - Page 10
    a table of revisions, printing instructions, and a notice of document confidentiality. Revision History Below is the history of the document revisions and a list of authors. Revision CA393-09450 Rev00 Description Initial document Responsible Engineer (TS) Press
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

Rewinder Calibration
Document details
Purpose
To describe how to calibrate the rewinder for high-sensitivity film substrates.
Scope
HP Indigo WS6000p Digital Press, HP Indigo WS6600 Digital Press, HP Indigo WS6800 Digital
Press, HP Indigo WS6000p Digital Press, HP Indigo WS6600p Digital Press
Document number
CA393-09450
Revision number
Rev00
Date
11 February 2015
Security level
HP Confidential
The information contained in this document is accurate at the date of release.
Check CE Suitcase for the most recent version of this document.
i