- HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 1
Rack to Tower and Tower to Rack System Conversion Guide HP Integrity rx2620 Manufacturing Part Number : AB359-90003 First Edition June 2005 © Copyright 2005 Hewlett-Packard Development Company, L.P. - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 3
a Tower System to a Rack System Process for Converting Your Tower System to a Rack System 21 Removing the Tower System's Access Panels 21 Removing the System's Pedestal 23 Installing the System's Rack Latches 24 Installing the System's Right Front Access Panel 26 Installing the System in its - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 4
Contents 4 - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 5
Screws 16 Figure 3-8. Locate the Top Access Panel's Retaining Snaps and Slots 17 Figure 3-9. Slide the Top Access Panel onto the System's Chassis 18 Figure 3-10. Install the Left-side and Right-side Access Panels 18 Figure 3-11. Install the Front Panel 19 Figure 4-1. Removing the Left-side and - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 6
Figures 6 - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 7
to the appropriate product support service. See your HP sales representative for details. The latest version of this document can be found online at http://docs.hp.com. What's in This Document The Rack to Tower and Tower to Rack System Conversion Guide - HP Integrity rx2620, contains these chapters - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 8
to Collect Before You Contact Support Before you contact HP support, you should: Step 1. Check information on troubleshooting and attempt to solve the problem. Refer to "Troubleshooting" in the Operation and Maintenance Guide for your system, available at http://docs.hp.com. • Note failure symptoms - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 9
of processor, memory, and PCI cards are used and where are they installed? • What accessories are installed? Step 4. Determine the following: • Which firmware versions are in use? • When did the problem start? • Have recent changes been made to the system? • Which operating system and version is - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 10
About This Document Where to Get Help 10 Chapter 1 - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 11
, never remove the system cover without first disconnecting the power cord from the power outlet and removing any connection to a telecommunications network. Always replace the cover before switching the system on again. CAUTION The HP Integrity rx2620 server depends on the system cover for proper - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 12
electricity, rest the accessory bag on top of the system while you are removing the accessory from the bag. Handle bottom of some raised floor tiles. Although this problem is relatively rare, it may be an issue installation of electronic equipment. Tools Required You will need a T-15 Torx driver - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 13
enclosure, reverse the instructions in the document Installation Guide for Midweight Slide Kit that was shipped with your rack installation kit. Removing the System's Front Access Panel To remove the rack system's front access panel, press in on the front access panel's retaining clips (located - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 14
's rack latch brackets: Step 1. Unscrew the left-side rack latch bracket's screws from the system's chassis. See Figure 3-2. Figure 3-2 Unscrew the Left-side Rack Latch Bracket's Screws Left Front Panel Rack Latch Bracket Mounting Screws Step 2. Rotate the rack latch bracket assembly away from - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 15
latch bracket assembly away from the chassis and remove the right-side rack latch bracket's retaining tab from its retaining slot on the system's chassis. See Figure 3-5. Figure 3-5 Remove the Right-side Rack Latch Bracket's Retaining Tab from Its Slot Rack Latch Bracket Bracket's Retaining Tab - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 16
Converting a Rack System to a Tower System Process for Converting Your Rack System to a Tower System Installing the System's Pedestal Here are the steps required to install the tower system's pedestal: Step 1. Place the pedestal's retaining slots on their retaining posts. See Figure 3-6. Figure - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 17
for Converting Your Rack System to a Tower System Installing the System's Access Panels Here are the steps required to install the access panels on the tower system: Step 1. Locate of the top access panel retaining hooks and their associated retaining slots on the system's chassis. You must align - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 18
that all hooks are in place. Figure 3-9 Slide the Top Access Panel onto the System's Chassis Top Panel Front of System Step 3. Position the left-side access panel at an approximate 45 degree angle with the left side of the system and insert its retaining slots on their retaining tabs, which are - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 19
retaining tabs located on the system's chassis. See Figure 3-11. Rotate the front access panel inward until it snaps in place. Figure 3-11 Install the Front Panel Front Access Panel Front of System Retaining Tabs Retaining Slots Step 5. Connect all of the system's power and external cables and - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 20
Converting a Rack System to a Tower System Process for Converting Your Rack System to a Tower System 20 Chapter 3 - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 21
to convert your HP Integrity rx2620 tower system to a rack system. For information on installing your system in a rack enclosure, read the document Installation Guide for Midweight Slide Kit (HP Part Number: 5064-9640). Process for Converting Your Tower System to a Rack System This section covers - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 22
to un-snap and rotate it away from the system. See Figure 4-3. After an approximate 45 degree rotation, lift the front access panel upwards and off of the two lower retaining tabs. Figure 4-3 Removing the Front Access Panel Front Access Panel Retaining Slots Retaining Tabs Step 5. Press in on - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 23
have to press in to release the Top Access Panel Back of system's chassis Step 6. Lift the top panel off of the system's chassis. See Figure 4-5. Figure 4-5 Lift the Top Access Panel off of the System's Chassis Top Access Panel Removing the System's Pedestal Here are the steps required to remove - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 24
two rack latch brackets for the purpose of securing the system in the rack enclosure. The left bracket has the left front panel attached to it and the right bracket does not. Here are the required steps for installing the rack system's rack latches: Step 1. Insert the left-side rack latch bracket - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 25
Inserting the Left-side Rack Latch Bracket's Retaining Tab into Its Slot Left Front Panel Bracket's Retaining Tab and Slot Rack Latch Bracket Step 2. Connect the left-side rack latch bracket to the system's chassis by screwing in its mounting screws. See Figure 4-9. Figure 4-9 Connecting the Left - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 26
's Chassis Mounting Screws Rack Latch Bracket Installing the System's Right Front Access Panel To install the rack system's right front access panel, position the panel at approximately 45 degrees to the front of the system and place the panel's retaining slots onto the chassis retaining tabs - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 27
Rack System Installing the Right Front Access Panel Retaining Tabs Retaining Slots Front Access Panel Retaining Clips Installing the System in its Rack Enclosure To complete the installation of the rack system in the rack enclosure, follow the instructions in the document Installation Guide for - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 28
Converting a Tower System to a Rack System Process for Converting Your Tower System to a Rack System 28 Chapter 4 - HP Integrity rx2620 | Rack to Tower and Tower to Rack System Conversion Guide (J - Page 29
HP-UX patches, 8 I install pedestal, 16 rack system into rack enclosure, 27 rack system's rack latch brackets, 24 rack system's right front access panel, 26 system access panels, 17 R regulatory model number, 7 remove pedestal, 23 rack system from rack enclosure, 13 rack system's front access panel
Rack to Tower and Tower to Rack System