HP Integrity rx2800 HP Insight Management WBEM Providers on Integrity Servers
HP Integrity rx2800 - i2 Manual
View all HP Integrity rx2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Integrity rx2800 manual content summary:
- HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 1
HP Insight Management WBEM Providers on Integrity Servers User's Guide HP Part Number: T2369-96016 Published: September 2010 Edition: 4 - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 2
such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. UNIX is a registered trademark of The Open Group. Microsoft, Windows, Vista, and Windows Server are - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 3
Provider Security for a User Account via the Windows® Command Line........11 3 Microsoft Windows Server™ 2008 Firewall configuration 13 Configuration...13 4 Insight Providers architecture 15 Data model...16 Insight Provider usage...18 HP Insight Management Services...19 Additional documentation - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 4
List of Figures 4-1 Insight Providers Architecture...15 4 List of Figures - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 5
List of Tables 4-1 DMTF profiles included in the data model 16 4-2 SMI-S profiles, subprofiles and packages included in the data model 17 4-3 HP profile extensions included in the data model 17 6-1 Supported operating systems...27 5 - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 6
operational status information 22 5-2 Displaying the system firmware version 22 5-3 Displaying computer system chassis model name, serial number, and asset tag 22 5-4 Listing system memory modules and their capacities 23 5-5 Listing system processors, current clock speed, and the number of - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 7
[ERROR NAME] The name of an error, usually returned in the errno variable. User input Commands and other text that you type. Variable The name of a placeholder in a command, function, or other syntax display that you replace with an actual value. [] The contents are optional in syntax. If the - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 8
8 - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 9
and system firmware interfaces. to make Integrity-specific management data and Integrity Support Pack. For information on configuring the WBEM Providers, see the Windows Server™ 2008 R2 on HP Integrity Servers Installation Guide and Windows Server™ 2008 SP2 on HP Integrity Servers Installation Guide - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 10
10 - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 11
, see the Windows Server™ 2008 R2 on HP Integrity Servers Installation Guide and Windows Server™ 2008 SP2 on HP Integrity Servers Installation Guide. WMI namespace security settings govern access to WMI information. Windows user accounts can be allowed or denied specific privileges per WMI namespace - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 12
3. Invoke the EnableRWMI.exe program to configure the account security for remote WMI access: EnableRWMI -a:localuser Or EnableRWMI -a:domain\user 12 Security - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 13
example, when the user is not an Administrator, some privileges might not exist by default. For more information, see the Microsoft® Windows Server™ 2008 R2 on HP Integrity Servers Installation Guide, Microsoft® Windows Server™ 2008 SP2 on HP Integrity Servers Installation Guide, and the Securing - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 14
that are more restrictive, but that allow remote WMI access in specific circumstances (such as restricting which users, computers, and network addresses can remotely access), depending on the details microsoft.com/en-us/library/aa822854.aspx). 14 Microsoft Windows Server™ 2008 Firewall configuration - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 15
servers, storage, network, Blade enclosures) HP added components HP existing components Microsoft WMI Framework Browser WMI Repository HPQ namespaces The Insight Providers extend the industry-standard CIM data model to support information that is specific to Integrity Server providers - Processor - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 16
SAS/SATA information - Fibre Channel HBA information • Other Providers - C-Class blade enclosure provider-Enclosure information for c-Class blades - Management processor provider-Management processor information - Software inventory provider-Installed HP software and firmware Base Server Profile Power - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 17
Name Host Hardware RAID Controller Profile Array Profile Block Services Package Disk Drive Lite Subprofile Multiple Computer System Subprofile HP Management Processor 1.1 Lite Profile P00101_-_HP_Mgmt_Proc_Lite_Profile.pdf P00102 - HP Fan Profile 1.3 P00102_-_HP_Fan_Profile.pdf P00103 - HP Power - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 18
HP Base Server Physical 1.2 Asset Profile P00114_-_HP_Base_Server_Physical_Asset_Profile.pdf P00115 - HP Fan Physical Asset Profile 1.0 P00115_-_HP_Fan_Physical_Asset_Profile.pdf P00116 - HP Power in the Integrity Support Pack (ISP), HP SIM, other client application, or script that supports WMI - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 19
Processor (MP). Automatic Server Recovery Enables a service that verifies if the system is frozen and reboots the system automatically (if frozen). Additional documentation In addition to this User Guide as are HP Integrity-specific extensions. • Event and Indication Reference, HP Management WBEM - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 20
20 - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 21
to obtain data from the Insight Providers using Microsoft Visual Basic Scripting Edition (VBScript) or any other scripting language that supports Microsoft ActiveX. This section shows examples for accessing Insight Provider data using VBScript code. Microsoft Visual Basic Scripting Edition examples - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 22
objComputerSystem.OperationalStatus WScript.Echo "Operational status: " & objOperationalStatus Next Next Example 5-2 Displaying the system firmware version strComputer = "." strNamespace = "\root\hpq" Set objWMIService = GetObject("winmgmts:\\" & strComputer & strNamespace) Set colSystemROMFirmware - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 23
.Echo "Caption: " & objMemoryModule.Caption WScript.Echo "Capacity (bytes): " & objMemoryModule.Capacity Wscript.Echo Next Example 5-5 Listing system processors, current clock speed, and the number of enabled cores strComputer = "." strNamespace = "\root\hpq" Set objWMIService = GetObject("winmgmts - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 24
) and Microsoft Windows PowerShell. The following command is used to display computer system status information using WMIC in noninteractive mode: wmic /namespace:\\root\hpq path hp_wincomputersystem get caption,OperationalStatus,StatusDescriptions The following Windows PowerShell script code can be - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 25
• Windows PowerShell (http://msdn2.microsoft.com/en-us/library/bb905330.aspx) • WMIC (http://msdn2.microsoft.com/en-us/library/aa394531.aspx) Scripting references 25 - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 26
26 - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 27
R2 and Service Pack 2 only Hardware support The following HP Integrity servers are supported: • rx2660 • rx3600 • rx6600 • rx7640 • rx8640 • HP Integrity BL860c • HP Integrity BL870c • HP Integrity BL860c i2 • HP Integrity BL870c i2 • HP Integrity BL890c i2 • HP Integrity Superdome Server sx2000 - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 28
28 - HP Integrity rx2800 | HP Insight Management WBEM Providers on Integrity Servers - Page 29
reseller: In the United States, see the HP US service locator webpage at: http://www.hp.com/service_locator In other locations, see the Contact HP worldwide (in English) webpage at: http://welcome.hp.com/country/us/en/wwcontact.html For HP technical support: In the United States, for contact options
HP Insight Management WBEM Providers
on Integrity Servers
User's Guide
HP Part Number: T2369-96016
Published: September 2010
Edition: 4