HP Integrity rx6600 FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu
HP Integrity rx6600 Manual
View all HP Integrity rx6600 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Integrity rx6600 manual content summary:
- HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 1
HP StorageWorks FC2143 and FC2243 4Gb PCI-X 2.0 host bus adapters for Linux and Windows installation guide Part number: AA-RW8JA-TE First edition: February 2006 - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 2
for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not FC2143 and FC2243 4Gb PCI-X 2.0 host bus adapters for Linux and Windows installation guide - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 3
this guide 7 Intended audience 7 Related documentation 7 Document conventions and symbols 7 HP technical support 8 Subscription service 8 the HP Smart Component 17 4 Installing the Linux driver 19 Prerequisites 19 Installing the Linux driver 19 5 Troubleshooting POST LED - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 4
Index 29 4 - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 5
Figures 1 Removing the bracket 2 LED location 3 Jumper settings 4 Class 1 laser product label 5 BSMI notice 6 Japanese notice 7 Korean notice 14 21 24 26 27 27 27 FC2143 and FC2243 4Gb PCI-X 2.0 host bus adapters for Linux and Windows installation guide 5 - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 6
Tables 1 Document conventions 7 2 Environmental specifications 10 3 Physical specifications 11 4 Media specifications 12 5 POST LED states 22 6 Jumper settings (Port 0 and Port 1 23 6 - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 7
support for additional assistance. Intended audience This guide is intended for system administrators who are experienced with the following: • Linux operating system • Windows operating system • HBAs Related documentation In addition to this guide, see the Emulex host bus adapters for Itanium - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 8
before calling: • Technical support registration number (if applicable) • Product serial numbers • Product model names and numbers • Applicable error messages • Operating system type and revision level • Detailed, specific questions Subscription service HP strongly recommends that customers register - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 9
-path RAM • Architectural support for multiple upper-layer protocols • State-of-the-art circuitry: • All PCI-X and Fibre Channel functionality contained in a single, custom, high-density, fully integrated Fibre Channel controller • Internal ARM 1136J-S processors with instruction and data cache for - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 10
Environmental specifications Table 2 lists the HBA environmental specifications. Table 2 Environmental specifications Feature Operating temperature Minimum 0°C/32°F Storage temperature -20°C/-40°F Relative humidity (noncondensing) 5% Airflow 100 lf/minute Maximum 45°C/113°F 70°C/158°F 95% N/A - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 11
through a single (FC2143 HBA) or dual (FC2243 HBA) optical fiber LC connector. Physical dimensions Power requirements Low-profile MD2 form factor, 6.600 inches by 2.536 inches, and accommodates both the FC2143 and FC2243 4Gb PCI-X 2.0 host bus adapters for Linux and Windows installation guide 11 - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 12
Media specifications Use multimode fiber optic cable (with short-wave lasers) that complies with the specifications listed in Table 4. Table 4 Media specifications Fiber optic cable 62.5/125 μm (multimode) 200 MHz bandwidth cable 50/125 μm (multimode) 500 MHz bandwidth cable Maximum length 300 meters - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 13
See your server documentation for additional installation instructions. WARNING! Disconnect the host from the power source before installing ships with a unique address identifier that is stored in flash memory. Fibre Channel industry standards issue two unique identifiers: worldwide port guide 13 - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 14
into the slot and press firmly until the HBA is seated properly. NOTE: Some HP server models support only PCI-X HBAs inserted in optional PCI-X riser cards or cages. For instructions on installing the riser card or cage, see your server documentation. 6. Secure the HBA to the chassis, following the - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 15
to the LC connector on the HBA. b. Connect the other end of the cable to the Fibre Channel device. NOTE: The HBAs , both products are mulitmode. 9. Turn on the computer and observe the power-on self-test (POST) LED results (see "POST LED states" on page 21). FC2143 and FC2243 4Gb PCI-X 2.0 host bus - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 16
16 Installing the HBAs - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 17
hotfixes that apply to your configuration and operating system. Installing the Windows drivers using the HP Smart Component This section describes how to install the Windows SCSIPORT miniport driver and Storport miniport driver. NOTE: HP does not support Device Manager to update drivers. Using Device - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 18
2. Install the driver: a. Double-click cp00xxxx.exe to open the Smart Component. b. Click Install. c. Click Reboot to complete the installation. NOTE: HP recommends that you install the driver automatically by using Install rather than Extract. Using Extract saves the files to disk, enabling you to - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 19
the HBA is to operate, and ensure that you have access to standard system documentation. NOTE: To install the driver, you must use the hp-lpfc RPM in the driver kit. Installing the Linux driver Before you begin, note the following about the lpfc driver: • HP does not support building the lpfc driver - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 20
.tar.gz file to the servers on which you will deploy the updated driver. b. Enter the following command: tar zxvf hp-lpfc-yyyy-mm-dd.tar.gz Entering this command extracts the files in the driver kit and copies them to the hp-lpfc directory. c. Change directory to the hp-lpfc directory. d. Enter the - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 21
troubleshooting information that you can use in the event of an HBA problem. • POST LED states, page 21 • Using the Event Viewer, page 22 • Windows miniport driver event log codes, page 23 • Linux driver events, page 23 • Setting the jumpers, page 23 POST LED states Table 5 describes the POST LED - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 22
Flashing Slow blink Restricted off-line mode (test active) 4. If a problem occurs, follow the instructions in this chapter to troubleshoot. Using the Event Viewer The SCSIPORT and Storport miniport drivers verify the HBA's POST LED states. If there is a failure or a suspected failure, an error - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 23
discharge (ESD) event. To prevent ESD damage, follow the instructions in "Electrostatic discharge" on page 27. Handle the card carefully HBA. Do not attempt to operate the HBA with the PCI device ID set to 1AE5 unless recommended by the driver installation instructions. FC2143 and FC2243 4Gb PCI-X - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 24
Figure 3 shows the jumper settings. Figure 3 Jumper settings 24 Troubleshooting - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 25
Regulatory compliance and safety Laser device All HP systems equipped with a laser device comply with not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein. • Allow only HP-authorized service for Linux and Windows installation guide 25 - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 26
label in Figure 4 or equivalent may be located on the surface of the HP-supplied laser device. Figure 4 Class 1 laser product label International notices and Electromagnetic Immunity • Power Quality: • EN61000-3-2 (IEC61000-3-2)-Power Line Harmonics • EN61000-3-3 (IEC61000-3-3)-Power Line Flicker • - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 27
To prevent damage to the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge nger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device. FC2143 and - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 28
tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the recommended equipment for proper grounding, have an HP-authorized reseller install the part. NOTE: For more information on static electricity, or assistance with product installation - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 29
, 7 documentation, HP web site, 7 LED states, 21 recording reference numbers, 13 setting jumpers, 23 troubleshooting, 21 HP Subscriber's choice web site, 8 subscription service, 8 hp hp-lpfc RPM, 19 lpfc driver, 19 troubleshooting, 23 log, event, 22 lpfc driver installing, 19 troubleshooting - HP Integrity rx6600 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 30
's choice, HP, 8 subscription service, HP, 8 symbols in text, 7 T text symbols, 7 troubleshooting event log, 22 HBAs, 21 Linux, 23 miniport driver event logs, 23 using POST LED states, 21 Windows Event Viewer, 22 W warnings, lasers radiation, 25 web sites HP documentation, 7 HP Subscriber's choice
HP
StorageWorks
FC2143
and
FC2243
4Gb
PCI-X
2.0
host
bus
adapters
for
Linux
and
Windows
installation
guide
Part
number:
AA-RW8JA-TE
First
edition:
February
2006