HP LH4r HP Netserver LC 2000 NetRAID-3Si and RS/12 Windows 2000 Advanced Serv
HP LH4r - NetServer - 256 MB RAM Manual
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
HP LH4r manual content summary:
- HP LH4r | HP Netserver LC 2000 NetRAID-3Si and RS/12 Windows 2000 Advanced Serv - Page 1
HP NetServer LC 2000 with NetRAID-3Si (HP Rack Storage/12) Windows 2000 Advanced Server Cluster Configuration Guide 29 January 2001 (see Versions at the end of this document) Introduction This document defines the configuration that Hewlett-Packard supports for the HP NetServer LC 2000, HP Rack - HP LH4r | HP Netserver LC 2000 NetRAID-3Si and RS/12 Windows 2000 Advanced Serv - Page 2
later). SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP (hot swap or fixed) Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared Controller Model No. of controllers Firmware BIOS Driver HP NetRAID-3Si Adapter D5955A - HP LH4r | HP Netserver LC 2000 NetRAID-3Si and RS/12 Windows 2000 Advanced Serv - Page 3
per NetRAID-3Si adapter LANs LAN connection 1 - 3 Rack Storage/12 D5989B or D5989C plus two D6025B or C's for each Rack Storage/12 Be sure cards in clustered RS/12 are either both'B' or both 'C' versions. 5 (fixed) 0 - 3, 8 - 15 (fixed) Any HP drive supported by storage enclosure including: HP - HP LH4r | HP Netserver LC 2000 NetRAID-3Si and RS/12 Windows 2000 Advanced Serv - Page 4
supported driver NOTE If the NIC used is the same type as the embedded NIC (D5013A/B), then the Client LAN NIC must use the same driver as the Intra-cluster NIC. 1 minimum Shared Storage Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer - HP LH4r | HP Netserver LC 2000 NetRAID-3Si and RS/12 Windows 2000 Advanced Serv - Page 5
using slot P5 for the shared storage NetRAID-3Si. 3. Cables between the servers and shared storage cabinets can be any HP LVD SCSI (offset) cable up to 10 meters. See "Cables" for Rack Storage/12 in the guide for a list of cables that can be used. HP Microsoft Cluster Server with Rack Storage/12 - HP LH4r | HP Netserver LC 2000 NetRAID-3Si and RS/12 Windows 2000 Advanced Serv - Page 6
Power Cabling to Separate Power Sources - HP LH4r | HP Netserver LC 2000 NetRAID-3Si and RS/12 Windows 2000 Advanced Serv - Page 7
Versions 29 January 2001 3 November 2000 5 September 2000 25 August 2000 20 August 2000 Added 1000 MHz with D5989C card. sym_hi.sys 5.00.2134.1 "or later" Listed nav. or Win2K cd as driver sources. Added redundant pdu comment. Initial release.
HP NetServer LC 2000
with
NetRAID-3Si (HP Rack Storage/12)
Windows 2000 Advanced Server
Cluster Configuration Guide
29 January 2001
(see
Versions
at the end of this document)
Introduction
This document defines the configuration that Hewlett-Packard supports for the HP NetServer LC 2000, HP
Rack Storage/12 and Microsoft Cluster Server.
These configurations minimize single points of failure
(SPOF) and provide extended availability.
The specific configuration certified and supported by both
Hewlett-Packard and Microsoft is defined, as are other guidelines to assist you in configuring your
clustered NetServers.
This guide is prescriptive; it describes the configurations supported by HP.
Any
deviance to these configurations can result in an inoperative cluster or an operating cluster with degraded
performance, hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LC 2000
Each node must be the same model SPU, but may have different sizes of
main memory, cache, and different CPU clock speeds.
Installation
Pedestal or racked
Number of nodes
2
Shared Storage
HP Rack Storage /12 with HP NetRAID-3Si controller and HP disks.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft approved.
See
Client LAN
below.