HP NetServer LH 4 with NetRAID-3Si (HP Rack Storage/12 Cluster Configuration Guide 22 February 2001 (see Versions at the end of this document) Introduction This document defines the supported HP NetServer LH 4 configurations with HP Rack Storage/12's and Microsoft Cluster Server. These - HP LH4r | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows NT4.0 Clusters - Page 2
UPS) using any power conditioner or UPS. Redundant power distribution units (PDU's) are strongly recommended. L.16.05 or later Microsoft Windows NT Server 4.0, Enterprise Edition SP6a or later HP NetServer LH 4 400, 450, 500, 550, 700 MHz. 2 - 4 4.06.13 PS or later (400, 450 MHz) 4.06.22 PS or later - HP LH4r | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows NT4.0 Clusters - Page 3
8 maximum per NetRAID-3Si adapter Configuration drives: Any HP drive supported by storage enclosure Cables Any 2 HP LVD SCSI cables from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A LANs LAN connection NIC: Model Driver Intra-cluster (Heartbeat) LAN HP - HP LH4r | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows NT4.0 Clusters - Page 4
1 Client LAN must use the same driver as the Intra-cluster LAN. 1 minimum Shared Storage Cabling This part of the guide defines the allowable cabling configuration for clusters using the HP NetServer LH 4 and HP Rack Storage/12's. Only this cabling configuration and these cables are supported. 4 - HP LH4r | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows NT4.0 Clusters - Page 5
HP Microsoft Cluster Server with Rack Storage/12's 5 - HP LH4r | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows NT4.0 Clusters - Page 6
Power Cabling to Separate Power Source 6 - HP LH4r | HP Netserver LH 4 NetRAID-3Si Config Guide for Windows NT4.0 Clusters - Page 7
MHz. Revised ac power cabling diagram to depict connecting power to each HP NetServer from separate power circuits and revised the No. of Power Supplies specification from "2 - 4" to "3 required, 4 for redundancy." Added two 18.2 GB disk drives for use with the Rack Storage/12. These are the D7031A
HP NetServer LH 4
with
NetRAID-3Si (HP Rack Storage/12
Cluster Configuration Guide
22 February 2001
(see
Versions
at the end of this document)
Introduction
This document defines the supported HP NetServer LH 4 configurations with HP Rack Storage/12’s and
Microsoft Cluster Server.
These configurations minimize single points of failure (SPOF) and provide
extended availability.
The specific configuration certified and supported by both Hewlett-Packard and
Microsoft is defined, as are other guidelines to assist you in configuring your clustered NetServers.
This
guide is prescriptive; it describes the configurations supported by HP.
Any deviance to these
configurations can result in an inoperative cluster or an operating cluster with degraded performance,
hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LH 4
Each node must be the same model SPU, but may have different sizes of
main memory and cache, and different CPU clock speeds.
Installation
Pedestal or racked
Number of nodes
2
Shared Storage
HP Rack Storage/12 with HP NetRAID-3Si controller and HP disks.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
HP D5013A/B with crossover cable. See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power