HP LH4r HP Netserver LH 6000 NetRAID-3Si Config Guide for Windows 2000 Advanc
HP LH4r - NetServer - 256 MB RAM Manual
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
HP LH4r manual content summary:
- HP LH4r | HP Netserver LH 6000 NetRAID-3Si Config Guide for Windows 2000 Advanc - Page 1
HP NetServer LH 6000 with NetRAID-3Si (HP Rack Storage/12) Windows 2000 Advanced Server Cluster Configuration Guide 1 February 2001 (see Versions at the end of this document) Introduction This document defines the configurations that Hewlett-Packard supports for the HP NetServer LH 6000, HP Rack - HP LH4r | HP Netserver LH 6000 NetRAID-3Si Config Guide for Windows 2000 Advanc - Page 2
later). SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP (hot swap or fixed) Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared Controller Model No. of controllers Firmware BIOS Driver HP NetRAID-3Si Adapter D5955A - HP LH4r | HP Netserver LH 6000 NetRAID-3Si Config Guide for Windows 2000 Advanc - Page 3
1 per RAID array 8 maximum per NetRAID-3Si adapter Cluster mode on Cache write- drives: Cables LANs LAN connection 1 - 3 Rack Storage/12 D5989B or C plus two D6025B's or two D6025C's for each Rack Storage/12 5 (fixed) 0 - 3, 8 - 15 (fixed) Any HP drive supported by storage enclosure including: HP - HP LH4r | HP Netserver LH 6000 NetRAID-3Si Config Guide for Windows 2000 Advanc - Page 4
the Client LAN NIC must use the same driver as the Intra-cluster NIC. 1 minimum Shared Storage Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer LH 6000 and HP Rack Storage/12. Only these cabling configurations and cables are supported. - HP LH4r | HP Netserver LH 6000 NetRAID-3Si Config Guide for Windows 2000 Advanc - Page 5
HP Microsoft Cluster Server with Rack Storage/12 - HP LH4r | HP Netserver LH 6000 NetRAID-3Si Config Guide for Windows 2000 Advanc - Page 6
Power Cabling to Separate Power Sources - HP LH4r | HP Netserver LH 6000 NetRAID-3Si Config Guide for Windows 2000 Advanc - Page 7
Versions 1 February 2001 3 November 2000 5 September 2000 Added D6025C. sym_hi.sys 5.00.2134.1 or later Initial release
HP NetServer LH 6000
with
NetRAID-3Si (HP Rack Storage/12)
Windows 2000 Advanced Server
Cluster Configuration Guide
1 February 2001
(see
Versions
at the end of this document)
Introduction
This document defines the configurations that Hewlett-Packard supports for the HP NetServer LH 6000,
HP Rack Storage/12 and Microsoft Cluster Server.
These configurations minimize single points of failure
(SPOF) and provide extended availability.
The specific configuration certified and supported by both
Hewlett-Packard and Microsoft is defined, as are other guidelines to assist you in configuring your
clustered NetServers.
This guide is prescriptive; it describes the configurations supported by HP.
Any
deviance to these configurations can result in an inoperative cluster or an operating cluster with degraded
performance, hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LH 6000
Each node must be the same model SPU, but may have different sizes of
main memory, cache, and different CPU clock speeds.
Installation
Pedestal or racked
Number of nodes
2
Shared Storage
HP Rack Storage /12 with HP NetRAID-3Si controller and HP disks.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft approved.
See
Client LAN
below.