HP LH4r HP Netserver LH Pro AutoRAID Install Guide

HP LH4r - NetServer - 256 MB RAM Manual

HP LH4r manual content summary:

  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 1
    cluster supported HP NetServers and the cluster software, and references the Shared Storage Supplement for installation and setup of the shared storage. • Shared Storage Supplement - This supplement is specific to the shared storage device you are using and must be used with the installation guide
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 2
    1 August 1998 Version History Updated the pdf to include the latest version of the HP NetServer Microsoft Cluster Installation Guide. This later version incorporates technical, grammatical and format changes along with adding installation instructions for additional HP NetServers. Package released
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 3
    HP NetServer LH Pro with A3700AB HP AutoRAID Disk Array Model 12H Cluster Configuration Guide August 1, 1998 Introduction This document defines the supported HP NetServer LH Pro and A3700AB HP AutoRAID Disk Array Model 12H (LH Pro/AutoRAID 12H) configurations for Microsoft Cluster Server. These
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 4
    CPU cache RAM No. of power supplies Hot swap cages Local storage I/O slots: LANs LAN connection NIC: Model Driver No. of NICs SPU I\O slot Local Storage Physical drive location Disk drives Controller SCSI bus HP NetServer LH Pro 6/200 Model 1 200 MHz. 2 (at least two are required) 4.05.14 or
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 5
    Terminator. Shared Storage Cabling This part of the guide defines the allowable cabling configurations for HP LH Pro NetServer clusters using the HP AutoRAID Disk Array Model 12H. Only these cabling configurations and cables are supported. These diagrams show single and daisy-chained configurations
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 6
    HP Microsoft Cluster Server with a single HP AutoRAID Disk Array Model 12H 4
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 7
    HP Microsoft Cluster Server and two daisy-chained HP AutoRAID Disk Array Model 12H 5
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 8
    This page intentionally left blank. 6
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 9
    HP NetServer Microsoft Cluster Installation Guide with Shared Storage System Supplement NetRAID (Storage System/6, Rack Storage/8 and Rack Storage/12) HP AutoRAID Disk Array Model 12H or HP A3661B Model 30/FC High Availability Disk Array 8 March 1999
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 10
    for errors contained of its software on equipment that reviewed for familiarization with safety markings and instructions used in this manual: • Microsoft and Server Division 10955 Tantau Avenue Cupertino, CA 95014-0770, USA © Copyright 1999, Hewlett-Packard Company HP NetServer Installation Guide
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 11
    (WITH NETRAID LOCAL AND SHARED STORAGE 22 LX/LXR PRO ...24 LXR 8000 ...25 INSTALL SERVICE PACK FOR ALL HP NETSERVERS 27 6 SHARED STORAGE SOFTWARE SETUP 28 SHARED STORAGE SETUP ...28 CREATE THE ARRAY FILE SYSTEMS...28 MATCH DRIVE LETTER ASSIGNMENTS ...33 7 MICROSOFT CLUSTER SERVER SOFTWARE SETUP
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 12
    HP NetServers, set up, assemble and cable the cluster, and install server and cluster software. NOTE This installation guide is incomplete without the supplement specific to your shared storage system. When directed by this guide, turn to the supplement to get the necessary instructions. Version
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 13
    A Graphical Overview to Setting Up the Cluster CAUTION Departing from the sequence shown here may cause unnecessary work and unpredictable results. HP NetServer Installation Guide 5
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 14
    Windows NT, version 4.0 and Service Pack (SP). See the Configuration Guide for your cluster solution for the applicable Windows NT and SP versions and Microsoft Cluster Server installation software. NOTE Some HP NetServers, as stated in part "5 NetServer Software Setup," require installing Windows
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 15
    the Configuration Guide for your cluster. • Cluster Installation Test. Downloaded from the Certified Installer Corner of the HP NetServer Clustering Solutions web site at: at: http://www.hp.com/netserver/products/cluster. • NIC drivers. Download HP drivers from the HP NetServer Clustering Solutions
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 16
    to the Shared Storage Systems and must be installed in specific PCI slots. See the Configuration Guide for your cluster configuration for the HP NetServer PCI slots to use. See instructions supplied with the component or see part "2 NetServer Hardware Setup" of the Shared Storage Supplement for
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 17
    3 Shared Storage Hardware Setup part "3 Shared Storage Hardware Setup" in the Shared Storage Supplement HP NetServer Installation Guide 9
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 18
    the system and instructions in the shared storage supplement. In addition you should have rack layouts of your system printed from the HP NetServers Rack Assistant program. If not, see HP NetServers web site to download this program at: http://www.hp.com/netserver. Connect the LAN Adapters Two sets
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 19
    specific to your HP NetServer as listed below. Secondly, you will install the applicable Service Pack on the NetServer. Select your procedure from the following list: You will... First Second Go to procedure for... LCII LC3 LH Pro LH 3 LH 3 (with NetRAID local storage) LH 4 LPr LPr (with NetRAID
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 20
    addresses and Intra-cluster LAN IP addresses must be on different subnets. LC3 Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server. The server boots from the
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 21
    time. NOTE The Client LAN IP addresses and Intra-cluster LAN IP addresses must be on different subnets. LH Pro 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server. The server boots from the CD
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 22
    sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. During reboot enter the Setup Utility by pressing F2. 4. Select User Preferences and then the LH4 Integrated NetRAID setting you want to use. If you are using
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 23
    1. Remove the HP NetServer Navigator CD, insert the boot floppy for Windows NT4.0, and exit Navigator to reboot the server. 2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: • The drivers are loaded from the NT 4.0 Drivers floppy disk
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 24
    complete, the D5013A NIC drivers must be manually set to the correct LAN speed. Log on and HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. During reboot enter the Setup Utility by pressing F2. 4. Using the Setup Utility disable the LH3 Integrated NetRAID. Integrated NetRAID
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 25
    detection and manually specify the mass storage drivers: 3. Load drivers using the NT 4.0 Drivers floppy disk you created in step 13 above (page 17). • Load the driver for the device you want to boot from. This will be the HP NetRAID Adapter Driver. • Load the IDE driver, since the CD drive is on
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 26
    is complete, the D5013A NIC drivers must be manually set to the correct LAN speed. Log on and from the HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. During reboot enter the Setup Utility by pressing F2. 4. Select User Preferences and then the LH4 Integrated NetRAID
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 27
    in the LH 4 internal bays this will normally be the embedded SCSI Symbios driver. • Secondly, load the IDE driver, since the CD drive is on the IDE bus. • Finally, load any other mass storage drivers you need. If you are using NetRAID for shared storage do not load the HP NetRAID driver at this
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 28
    procedure, LPr (with NetRAID Local and Shared Storage) on page 22. Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. If you have special NetServer local SCSI bus
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 29
    Symbios driver on the drivers disk. Select "SCSI Symbios driver for the HP NetServer LPr." • Secondly, load the IDE driver, since the CD drive is on the IDE bus. • Finally, load any other mass storage drivers you need. If you are using NetRAID for shared storage do not load the HP NetRAID driver at
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 30
    for both. To use NetRAID adapters for both shared and local storage, you must use two adapters. Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. If you have special
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 31
    its IP address and subnet mask. This will be the LAN adapter for the intra-cluster LAN. Select adapter [1] and specify its IP address and subnet mask. This will be the LAN adapter for the client LAN. Set TCP/IP Properties for DNS, WINS Address, etc. at this time. HP NetServer Installation Guide 23
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 32
    intra-cluster LAN should be set to 100 Mbps. Do not use the Auto setting. LX/LXr Pro Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server. The server boots from
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 33
    These procedures provide instructions for servers using NetRAID, AutoRAID Model 12H, and Model 30/FC shared storage solutions Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 34
    , select Properties then Settings and set the network speed to the appropriate setting (either 10 Mbps or 100 Mbps) for your network. The intra-cluster LAN should be set to 100 Mbps. Do not use the Auto setting. HP NetServer Installation Guide 26
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 35
    Service Pack for All HP NetServers Refer to the Configuration Guide for your cluster configuration and install the applicable Microsoft Service Pack (SP3 or SP4). Do not install the Hot Fix associated with Service Pack 3 at this time. NOTE Do not install the Microsoft Cluster Server Software
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 36
    Software Setup" in the Shared Storage Supplement Create the Array File Systems Use the instructions below and Windows NT Disk Administrator to partition, assign drive letters, and format the shared logical drives -shared) disks followed by the shared disk arrays. HP NetServer Installation Guide 28
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 37
    the capacity would be one-half the capacity of the two drives. 3. Click OK to include the full disk in the partition (the default). In the following example, Disk 1 has been partitioned and Disk Administrator assigned a temporary drive letter to the disk array. HP NetServer Installation Guide 29
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 38
    Disk Administrator, Partitioned Disk Array NOTE Do not partition a disk into separate drives. Microsoft Cluster Server Software will only manage one partition per disk. 4. Repeat steps 1 through 3 assigned the next sequential letter to the disk array. HP NetServer Installation Guide 30
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 39
    Drive Letter. Disk Administrator displays the Assign Drive Letter dialog. 3. In the dialog, select a drive letter, and click OK. To avoid confusion later, HP recommends that you choose sequential drive letters. The example in this guide uses drive letters X and Y. HP NetServer Installation Guide
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 40
    the Format dialog make sure that File System is set for NTFS. 4. In the Volume Label field type a label (name) for the drive. Choosing a descriptive label such as "Shared Drive X" will be helpful later when you need to match drive letter assignments at System B. HP NetServer Installation Guide 32
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 41
    you need to shut down System A (but leave it powered on), reboot System B, then assign the same drive letters used on System B as were assigned to System A. Shut Down System A 1. From the Windows NT the computer powered on. The computer is powered on but idle. HP NetServer Installation Guide 33
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 42
    permanent drive letter assignments for each array initialized with System A. 6. When done, Disk Administrator will show matched drive letter assignments as in the opposite node. Exit Disk Administrator. The arrays are now fully configured for use by the cluster. HP NetServer Installation Guide 34
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 43
    CD of Microsoft Windows NT Server, Enterprise Edition in the CD-ROM drive of System B. 2. Run the Microsoft Cluster Server setup program. Setup.exe Cluster Server software setup of System A. Click Next. Microsoft Cluster Administrator, Assigning a Cluster Name HP NetServer Installation Guide 35
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 44
    the LAN adapter according to use (for example, intra-cluster LAN). When you enable cluster use setup gives you three options: • Use for all communications Choose this option if you are configuring a client LAN adapter, and System A and B reside on the same IP subnet. HP NetServer Installation Guide
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 45
    configured all LAN adapters, click Next. 11. Setup lists your LAN adapters and asks you to prioritize them for internal communications between nodes. Move the Intra-cluster LAN to the top of the list so it has the highest priority. See the example dialog below. HP NetServer Installation Guide 37
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 46
    specifications and starts the cluster service. 15. Microsoft Cluster Server is now fully installed on System B. Reboot System B. 16. To finish installation of the Microsoft Cluster Server, leave System B running, go to the next procedure and install MSCS on System A. HP NetServer Installation Guide
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 47
    not already downloaded clusfixi.exe, see "Software" in part "1 What's Needed." 2. Install the Microsoft hotfix clusfixi.exe on System A and System B. NOTE When downloading the file, refer to the Microsoft readme file for instructions on installing the hotfix. HP NetServer Installation Guide 39
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 48
    Hardware Verification and Labeling Utility scans the system and checks system integrity before you perform system configuration. It helps you simplify the contains detailed information on the utility and instructions for setting up and running the utility. HP NetServer Installation Guide 40
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 49
    to download this program. Run CIT Follow the instructions in the CIT program. If additional information is needed refer to CIT on-line help. CIT help is context sensitive and has been expanded to provide detailed instructions for each step of the program. HP NetServer Installation Guide 41
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 50
    HP AutoRAID Disk Array Model 12H Supplement to HP NetServer Microsoft Cluster Installation Guide June 1, 1998
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 51
    the warranty for this product, contact your reseller and/or your HP representative. Safety Considerations The product and related documentation must be reviewed for familiarization with safety markings and instructions before installation and operation. Safety Symbols WARNING A WARNING denotes
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 52
    1 WHAT'S NEEDED ...5 SOFTWARE...5 NEED MORE HELP?...5 2 NETSERVER HARDWARE SETUP...6 INSTALLING THE HP A5252A SCSI HOST BUS ADAPTER SHARED STORAGE SOFTWARE SETUP 18 POWER UP THE DISK ARRAY ...18 INSTALL AUTORAID MANAGER SOFTWARE ...18 SET UP AUTORAID MANAGER ...19 CREATE LOGICAL DRIVES...20 Figures
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 53
    Disk Array Model 12H as shared storage in an HP NetServer cluster. This supplement is incomplete without the HP NetServer Cluster Installation Guide. When prompted in this supplement, return to the HP NetServer Cluster Installation Guide for more information on installing the other components of
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 54
    installing the HP AutoRAID Disk Array Model 12H. These documents are included with the disk array. • HP AutoRAID Disk Array Model 12H User's And Service Manual • HP AutoRAID Disk Array Model 12H System Administrator's Guide for HP-UX and Windows® NT To part 1 of the HP NetServer Microsoft Cluster
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 55
    SPU I/O slot to use. NOTE The A5252A uses the standard Windows NT SCSI driver included with NT 4.0 Service Pack 3, so it is not necessary to install an additional driver. Refer to the Cluster Configuration Guide for more information. To part 2 of the HP NetServer Microsoft Cluster Installation
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 56
    AutoRAID Disk Array Model 12H for use as shared storage on your NT cluster. NOTE Refer to the HP AutoRAID Disk Array Model 12H User's And Service Manual for instructions on rack mounting the disk array. Identify Controls and Connectors The various controls and connectors used during installation
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 57
    Figure 2. Disk Array Rear Panel 1 - Power Module Status Light 5 - Control Panel Display 2 - Disk Module Status Light 3 - Fan Module Status Light 4 - Power/Standby Switch 6 - Control Panel Status Light 7 - Controller Module Status Light Figure 3. Disk Array Controls and Indicators (cover open
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 58
    Install Disk Modules NOTE To improve enclosure cooling and balance the load on the internal SCSI buses, the disk modules should be installed from left to right and from top to bottom. Disk module SCSI addresses are automatically preset by the backplane inside the disk array enclosure upon
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 59
    Install Controller Batteries The two battery packs included with the controller module must be installed before the controller module is installed in the disk array. 1. Remove the battery cover latch and then remove the RFI shield (if necessary, you can use a flat-bladed screwdriver to remove the
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 60
    Install Controller Modules CAUTION Before installing a controller module, ensure that all of the pins on the controller connector are straight. Bent pins will cause the controller module to fail, and the array will not function properly. Also, do not attempt to install the controller module
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 61
    Connecting Disk Array Power Cords 1. Connect a power cord to each of the three power receptacles on the rear of the disk array. 2. Plug the other end of the power cords into the cabinet power strips as shown in Figure 7. NOTE The disk array cannot operate on a single power supply; consequently,
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 62
    History 3 - Scroll Text Left 4 - Cancel Selection 5 - Display Main Menu 6 - Scroll Menus/Items 7 - Select Menu/Items 8 - Scroll Text Right 9 - Control Panel Status Light 10 - Controller Indicator (x or y) 11 - Menu/Item Scroll Indicator Figure 8. Control Panel Display and Function Keys 13
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 63
    the default drive number 0, then press Enter. 5. Set the capacity size to the default of 100 MB (megabytes), then press Enter. 6. When prompted to Confirm, press Enter. NOTE Make sure you leave the disk array power on after completing these steps. To part 3 of the HP NetServer Microsoft Cluster
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 64
    be made in a specific manner so that the appropriate redundancy and, therefore, high availability requirements are met. Use the diagrams included in this supplement or the diagrams in the Cluster Configuration Guide for your cluster configuration. To part 4 of the HP NetServer Microsoft Cluster
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 65
    Figure 9. SCSI Bus Cabling for Connecting One Disk Array 16
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 66
    Figure 10. SCSI Bus Cabling for Connecting Multiple Disk Arrays 17
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 67
    Software The AutoRAID Manager software should be installed on both servers. 1. Insert the HP AutoRAID on Windows NT CD into the CD-ROM drive is installed on the disk array, download HP26 to the disk array. The HP26 firmware is included with the software. CAUTION Firmware version HP26 or later
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 68
    Set Up AutoRAID Manager After installing the software, a few steps must be performed before you is properly connected to the servers. This includes proper termination of the SCSI bus. • Make sure there is at least one logical drive created on the disk array. A logical drive should have been created
  • HP LH4r | HP Netserver LH Pro AutoRAID Install Guide - Page 69
    configuration of the disk array hardware, logical drive 0 was created on the disk array. This logical drive is reserved for exclusive access by the AutoRAID Manager software and should not be formatted or used for data storage. To part 6 of the HP NetServer Microsoft Cluster Installation Guide 20
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

Microsoft Cluster Installation
Documentation
To assist you in installing your HP NetServer Microsoft Cluster, this file contains three
separate documents combined into one pdf file.
Configuration Guide
- This guide provides configuration information specific to your
cluster configuration that you will need during the installation of your cluster.
HP NetServer Microsoft Cluster Installation Guide
- This is the first of two
documents used to install the cluster.
It covers the installation of all cluster supported
HP NetServers and the cluster software, and references the Shared Storage Supplement
for installation and setup of the shared storage.
Shared Storage Supplement
- This supplement is specific to the shared storage device
you are using and must be used with the installation guide.
It provides instructions for
installing and setting up your shared storage devices.
17 March 1999
(See next page)